• Title/Summary/Keyword: 김봉훈

Search Result 194, Processing Time 0.043 seconds

The Performance Evaluation of E-PON System for TPS (FTTH E-PON 시스템의 TPS 성능 평가)

  • Kwon, Jeong-Gook;You, Jae-Hoon;Kim, Bong-Tae;Lee, Sang-Ho
    • Journal of KIISE:Information Networking
    • /
    • v.36 no.4
    • /
    • pp.360-368
    • /
    • 2009
  • Recently, broadband access networks have been competitively deployed all over the world with the development of various multimedia services for such a network. ETRI(Electronics and Telecommunications Research Institute) built the FTTH(Fiber-To-the-Home) service center to develop a next-generation equipment and a high-quality service/platform as well as to promote domestic industry in the field of optical communication. The FTTH service center has a variety of test equipments such as FTTH standard testbed for a BMT(bench mark test), a network operation center, and IPTV service equipments. Also, ETRI deployed a new type of commercial optical access networks cooperating with ISP(Internet Service Provider). This paper presents the performance evaluation of FTTH E-PON(Ethernet Passive Optical Network) system as a platform for TPS(Triple Play Service) based on QoS(Quality of Service) and QoE(Quality of Expericence) issues. This FTTH E-PON system is successfully demonstrated as an optical access network system by commercial network service provider and the FTTH service center of ETRI.

Generation of Inflow using Physical based Distributed Model for Establishing Water Supply Standard of New Dam (신규댐 용수공급 조정기준 수립을 위한 물리적 기반 분포형 모형 적용 댐 유입량 생산)

  • Son, Chan-Young;Kim, Bong-Jae;Lim, Dong-Jin;Lee, Dong-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.40-40
    • /
    • 2018
  • 현실화된 기후변화로 인하여 강수패턴 및 강수량의 변화가 발생함에 따라 물 관리의 불확실성이 증가하고 있는 실정이며 또한 2014년부터 시작된 극심한 가뭄은 안정적인 용수공급에 많은 어려움을 주고 있다. 예로 보령댐의 경우 저수율이 2015년 19%, 2017년 8.3%로 역대 최저를 기록한 바 있고 2018년 3월 기준 운문댐과 밀양댐의 경우 저수율이 각각 11%(심각), 26.2%(경계)로 극심한 물부족에 시달리고 있다. 이러한 극심한 가뭄에 대응하기 위해서는 시설간 연계 운영, 급수체계 조정, 도수로 가동 등과 같은 구조적 대책과 더불어 저수용량에 따라 용수공급량을 감축하는 형태의 비구조적 대책의 일환인 용수공급 조정기준이 동시에 이루어져야 한다. 용수공급 조정기준은 국토교통부에서 주기적으로 발생하고 있는 가뭄에 대하여 대응하기 위해 만들어진 기준으로 다목적댐의 저수량을 기준으로 단계별(관심, 주의, 경계, 심각) 공급량을 감축하여 장기간 공급함으로써 국가재난을 사전에 예방하는 것을 목표로 하고 있다. 이러한 용수공급 조정기준을 수립하기 위해서는 최소 20년 이상의 과거 관측된 유입량 자료를 모의 발생하여 이수안전도 95%이상을 만족하는 단계별 용수공급 조정 기준선을 작성하게 된다. 하지만 신규 댐의 경우 관측된 유입량 자료가 전무함에 따라 용수공급 조정 기준을 수립하는데 어려움이 있다. 따라서 본 연구에서는 신뢰할 수 있는 유입량 자료를 생산하기 위해 첫 번째로 물리적 기반인 분포형 강우-유출 모형을 구축하고 검보정을 수행하였으며 이처럼 구축된 강우-유출모형을 이용하여 다수의 유입량 자료를 생산하였다. 두 번째로 SAMS 2007을 이용하여 유입량 자료를 모의 발생시켰으며 이를 저수지 운영에 활용하여 이수안전도 95%를 만족하는 용수공급 조정기준을 수립하였다. 본 연구의 결과는 극심한 가뭄에 대비하여 안정적인 용수공급 및 수자원 확보 등 이수적인 측면에서 크게 활용 가능할 것으로 판단된다.

  • PDF

Methodology for estimating the damage rate of equipment mounted on the warship (해상 플랫폼 탑재장비 손실률 산정 방법 - 워게임모델 적용을 중심으로 -)

  • Jeong Kwan, Yang;Bong Seok, Kim;Ji Hoon, Kyung;Hyun Shik, Oh
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.18 no.2
    • /
    • pp.108-116
    • /
    • 2022
  • Accurately predicting wartime resources requirements and preparing war supplies in peacetime is an important task that can determine the outcome of the war by guaranteeing the duration of the operation. The wartime warship damage rate is a measure of estimating the battle damage of our warships in the process of performing battles to achieve the war goal. In the previously studied wartime warship damage rate estimation method, when damage occurs, long-term repair is required due to the complexity and specificity of the ship structure. Only the case of a complete defeat at the level of sinking was defined as a damage, and even if it was impossible to perform a maritime operation mission, it was not estimated as a damage if the level of sinking was not reached. Therefore, in order to improve the reliability of the wartime warship damage rate, the equipment damage assessment level can be estimated based on the warhead weight of the threat weapon system, the vulnerability rate of the warship's equipment, and the warship's hull. In the future, it is expected that the estimation methodology proposed in this study will be used as a simulation logic when developing a model for analyzing the wartime resources requirements for the warship's equipment and hull.

The Effect of Nitrogen Fertilization on Vascular Bundles and Air Space Development in the Internodes of Several Rice Varieties, and the Relationship between the Histological Structure and Panicle Characteristics (질소시용이 수도품종의 절간조직구조에 미치는 영향 및 조직구조와 수상특성과의 관계)

  • Lee, Dong-Jin;Kim, Ki-Joon;Lee, Jong-Hoon;Kim, Bong-Ku;Chae, Je-Cheon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.30 no.1
    • /
    • pp.107-115
    • /
    • 1985
  • Experiments were carried out to find out varietal differences in vascular bundles and air spaces in the internodes, in relation to ear characteristics using plant samples from various N levels. The number and size of large vascular bundles in the internodes increased by increasing N fertilization, especially in the 1st internodes for the numbers, and 3rd, 4th, and 5th internodes for the size. Comparing the varieties, indica/japonica cross-bred varieties had more and larger vascular bundles than japonica varieties. The number of air spaces also increased by the increase of N fertilization. Comparing the varieties, Pungsanbyeo and Chucheongbyeo had more air spaces than Yushin and Jinheung in 3rd or upper internodes. The number and size of vascular bundles and the thickness of internodes had significant correlation with the panicle length, number of primary and secondary branches and number of spikelets per panicle.

  • PDF

A Review of the Physical Performance of Lightweight Aerated Concrete for Use as an Interior Core Material in Fire Doors (방화문 내부 심재로 적용하기 위한 경량기포콘크리트의 물리적 성능 검토)

  • Hong, Sang-Hun;Kim, Bong-Joo;Jung, Ui-In;Kim, Hae-Nah;Park, Jun-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.111-112
    • /
    • 2023
  • With the development of cities, the density of the population is continuously increasing as buildings become larger and more high-rise, but since the Haeundae residential complex fire in Busan in 2010, there has been a growing need to meet the fire protection performance of buildings as large-scale fires continue to occur every year. On the other hand, fire doors, which are one of the fire protection performance of buildings, have been judged unqualified in 82% of cases when fire doors constructed on the actual site were inspected after completion. The reason for this is that paper honeycomb and glasswool, which are used as core materials for fire doors, absorb moisture, reducing thermal insulation performance, and sagging due to increased weight, leading to performance degradation due to warping in empty spaces. To overcome these problems, research is underway to apply lightweight aerated concrete, an inorganic material, as a core material. Therefore, in order to select a blowing agent that produces stable bubbles prior to the production of lightweight bubble concrete for application as a fire door inner core, this study examined the physical performance according to the type of blowing agent and dilution concentration, and the following conclusions were drawn. Compared to vegetable bubbles and independent bubbles, synthetic bubbles have 3~8% higher thermal conductivity than independent bubbles, but 3~6% lower slurry density than vegetable bubbles, and 2~13% higher compressive strength, which is thought to be an improvement of synthetic bubbles.

  • PDF

Reviewing the fireproofing of lightweight aerataed concrete for fire door interior cores (방화문 내부 심재용 경량기포콘크리트의 방화성 검토)

  • Hong, Sang-Hun;Kim, Bong-Joo;Jung, Ui-In;Kim, Hae-Nah;Park, Jun-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.43-44
    • /
    • 2023
  • Fire doors installed to prevent the spread of fire in buildings are made of paper honeycomb, glass wool, and other materials. Due to their high water absorption rate, they absorb ambient moisture and degrade, and their increased weight causes them to sag internally, creating voids that can warp in the event of a fire and allow flames to pass through. To overcome these issues, research is being conducted on the physical performance of lightweight aerated concrete. However, there is a lack of research on how to ensure fire resistance. Therefore, in this study, the backside temperature of lightweight aerated concrete formulations was measured and compared and analyzied with the physical performance. Since it is difficult to achieve low density by saturation alone, aerated concrete with EPS was produced, which resulted in a density reduction of 24'26%, but the strength increase per unit cement increase was 5'25%, which tended to be lower than the formulation without EPS. The results showed that the lightweight aerated concrete with EPS was 130~140℃ lower than the lightweight aerated concrete with EPS, which is believed to be due to the melting point of EPS delayed the heat diffusion. In the future, wo plan to conduct research to identify the optimal formulation for fire door core materials by varying the amount of EPS added and using industrial by-products to increase long-term strength.

  • PDF

Effect of Compatibilizers on the Mechanical Properties of Waste Polypropylene/Waste Ground Rubber Tire Composites (상용화제의 첨가에 따른 재생 폴리프로필렌/폐타이어 분말 복합체의 기계적 특성 분석)

  • Park, Ki-Hun;Kim, Dong-Hak;Jung, Jong-Ki;Kim, Seong-Gil;Bang, Daesuk;Oh, Myung-Hoon;Kim, Bong-Suk
    • Resources Recycling
    • /
    • v.23 no.1
    • /
    • pp.70-79
    • /
    • 2014
  • In this study, waste polypropylene and waste ground rubber tire(WGRT) composites were prepared by using a modular intermeshing co-rotating twin screw extruder. The effect of three main factors such as WGRT contents, particle size, compatibilizers on the properties of waste PP/WGRT composites was extensively investigated. Tensile strength of the composites was decreased with an increase in WGRT contents, whereas elongation at break and impact strength were increased. The tensile strength, elongation at break and impact strength of the composites with the smaller size of the WGRT were more enhanced. Addition of PP-g-MA into waste PP/WGRT composites exhibited better tensile strength. However, elongation at break and impact strength were slightly decreased with increasing of PP-g-MA. On the other hand, tensile strength, impact strength and elongation at break of the composites were increased by adding the EPDM-g-MA and SEBS-g-MA. Especially, elongation at break was significantly increased compared to the composite with PP-g-MA.

Cure Behavior and Tensile Properties of Ethylidene Norbornene/endo-Dicyclopentadiene Blends (Ethylidene Norbornene/endo-Dicyclopentadiene 블렌드의 경화 거동 및 인장 특성)

  • Jung, Jong Ki;Choi, Jung Hwa;Yang, Guang;Park, Jongmoon;Kim, Donghak;Kim, Seonggil;Lee, Jong Keun;Oh, Myung-Hoon;Kim, Bongsuk;Bang, Daesuk
    • Polymer(Korea)
    • /
    • v.39 no.3
    • /
    • pp.506-513
    • /
    • 2015
  • Ethylidene norbornene (ENB) and its blends with endo-dicyclopentadiene (endo-DCPD) were prepared and reacted via the ring-opening metathesis polymerization (ROMP) reaction with the $1^{st}$ and $2^{nd}$ generation Grubbs' catalysts. Dynamic exothermic behaviors during ROMP and tensile properties after ROMP were evaluated using a differential scanning calorimeter (DSC) and a universal testing machine (UTM) for the samples, respectively. It revealed that the ROMP rate was accelerated with the less contents of endo-DCPD and under the $2^{nd}$ generation catalyst. Also, the addition of endo-DCPD and the $1^{st}$ generation catalyst resulted in higher tensile modulus and strength but lower toughness. Gel fraction measurement and fracture surface observation were made to understand the tensile properties.

A Study on the Effective Display Method of Optician's Shop (안경원의 효율적인 디스플레이 방법에 관한 연구)

  • Han, Sun-Hee;Kim, Bong-Hwan;Han, Myung-Hee;Kim, Chung-Mi;Lee, Seung-Hyun;Jin, Kang-Hun;Lee, Hae-Jin;Jeong, Hyo-Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Purpose: The purpose of this study was to research the display of optician's shop through questionnaire to suggest the direction for more effective display method. Methods: The study visited 50 optician's shops located in main area of Ulsan (university street, downtown and residential street), performed questionnaire and researched optician's display preference. Results: The displays preferred by opticians were as follows. They displayed contact lens in entrance of shop, displayed sunglasses in the wall rather than displayed them in the center of shop and displayed medium or low price products in the center so that consumers could access them conveniently. In addition, they prepared resting place for customer's convenience by locating it in entrance or inside of shop. Conclusions: It seems that effective display of optician's shop can attract consumer's mind and improve purchase, resulting in significant change of optician's shop sales. Therefore, it is necessary to perform the study to use systematic, discriminated display strategy so that shop image can be controlled consistently and continuously.

Chemical Devulcanization for the Recycling of Rubber Powder of Waste Tires and Mechanical Properties (폐타이어 고무분말 재활용을 위한 화학적 탈황과 기계적 물성 평가)

  • An, Ju-Young;Park, Jong-Moon;Bang, Daesuk;Kim, Bong-seok;Oh, Myung-Hoon
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.59-65
    • /
    • 2015
  • Recycling of vulcanized rubber products is a serious problem in the world. A quantity of generated waste tires becomes much more and more because of increasing demands on automobiles, resulted in the cause of serious secondary pollution by sulfur component that is crosslinked to incineration or landfill. In addition, crosslinked surfur is used to interfere with the binding of the raw material rubber. In this study, we analyzed the degree of devulcanization by the chemical devulcanization. Devulcanization ratio of the samples were systematically analysed by variables such as time and temperature. In addition, the effect of swelling method as a pre-treatment process was also measured. A rubber specimen was deepened in a organic 2-buthanol solutions during various times of 1 ~ 5 hrs at 100, 150, $200^{\circ}C$ respectively, then to calculate the crosslink density and the number average molecular weight by using a parallel expansion process, which showed devulcanization degree of analyzed samples quantitatively. Also, the mechanical properties were measured with the samples prepared by using a hot press.