• Title/Summary/Keyword: 김남석

Search Result 158, Processing Time 0.031 seconds

관능성 단량체 종류에 따른 4원 용액형 아크릴계 점착제의 합성과 물성에 관한 연구 (The Effects of Functional Monomers on the Synthesis andPhysical Properties of Solution Type Quaternary Polymer Acrylic Pressure-Sensitive Adhesives)

  • 김남석;김성훈
    • 한국응용과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.525-532
    • /
    • 2008
  • To prepare a solution type acrylic pressure-sensitive adhesive, quarter polymers were synthesized from butyl acrylate(BA), 2-ethylhexylacrylate(2-EHA) as a base monomer, methyl methacrylate(MMA) as a comonomer, each of methacrylic acid(MAA), acrylic acid(AA) as a functional monomer. Acrylic solution type pressure-sensitive adhesives(PSA's) of isocyanate derivative crosslinking PSA's were prepared by crosslinking of BEMM, BEMA with toluene-2,4-diisocyanate. The structure of adhesive was identified by FT-IR. The viscosity was measured by using Brookfield DV-III and molecular weight was measured by using gel permeation chromatography. The physical properties of polyethylene film coated with BEMMT, BEMAT were measured as a function of the concentration. As the result, BEMMT(0.6, 0.8), BEMAT(0.6) showed peel adhesion of $160{\sim}180\;g_f$/25 mm width and shear adhesion of more than 24 hours, and tackiness of $4/32{\sim}6/32$ which was relevant to commercial usage.

한국 대학도서관의 학위논문 관리 및 이용에 관한 연구 (Study on the management & utilization of these and dissertation in university libraries of Korea)

  • 김남석;조도희
    • 한국도서관정보학회지
    • /
    • 제23권
    • /
    • pp.109-145
    • /
    • 1995
  • This study is to find out general problems a n.0, ppeared in the management and utilization of these and dissertation and to suggest some recommendations, through the survey and analysis on the Korean university libraries. Questionnaires were sent to 109 university libraries which offer master's and doctoral degrees, during the period between March 7 and March 27, 1995. Responded questionnaires of 91 libraries (about 83%) were processed using SAS. The results of this survey can be summarized as follows: 1. Most of Korean university libraries have the collections of theses and dissertations ranging from less than 10,000 volumes (27 libraries ; 32.1%) ; 10,000 to 30,000 volumes (20 libraries ; 25.0%) ; to more than 80,000 volumes (16 libraries ; 19.0%). The largest collection was around 200,000 volumes. 2. In the management of them, 35 libraries (38.5%) were active in collecting them, but 56 libraries (61.5%) were not active, mainly for the shortage of manpower and the space problems. In 62.6% of libraries, they are arranged with the books. And 51.3% of libraries process them in less than one month. 46 libraries (52.9%) computerize their system, and among them 40 libraries (87%) establish their own databases. 3. The collections of theses and dissertations are called by various name, including periodical room, theses room, reference reading room etc. reaching to 15 kinds. 71 libraries (78.0%) adopt open system, and 17 libraries closed system ; and 2 libraries (3.2%) partial open system. 62 libraries (68.1%) arrange them in the order of call number, while 20 libraries (31.9%) by other criteria.

  • PDF

백금 합금의 고온산화휘발특성

  • 김남석;현승균;김목순;홍길수;양승호;윤원규
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2010년도 춘계학술발표대회
    • /
    • pp.50.1-50.1
    • /
    • 2010
  • 내열성과 내부식성, 촉매능력등이 뛰어난 백금은 자동차 배출가스 정화촉매, 유/무기화학반응의 공정 촉매, 석유화학산업에서의 촉매 등 촉매 뿐만 아니라 용융유리용 도가니, 유리 섬유용 부싱 등의 유리산업, 백금 열전대 외에도 전기/전자기기, 치과용 합금, 장신구, 항공우주,등의 많은 분야에서 폭넓게 쓰인다. 한편 낮은 기계적 특성을 개선하기 위하여 로듐 등의 백금족 원소를 첨가한 합금을 제조하여 이용하고 있지만 로듐의 공금 부족과 이에 따른 가격 상승으로 인한 대체조성의 설계가 요구되고 있다. 또한 고온의 산화분위기에 노출이 되면 산화물이 형성되고 이것이 휘발하여 중량의 손실이 생긴다고 알려져 있다. 본 연구에서는 백금 합금의 이러한 문제점의 해결방안을 제시하고자 백금족 원소를 첨가하고 첨가 원소별 산화휘발의 정도를 측정하였다. 시편은 plasma arc melting법으로 각각 Pt, Pt-20%Rh, Pt-11%Ir, Pt-10%Rh-10%Ir의 조성을 가지는 합금을 만든 후 압연을 하여 판상으로 만들었고, 이를 각각 $1000^{\circ}C$, $1200^{\circ}C$, $1400^{\circ}C$ 등에서 각각 96시간 까지 산화휘발시켜 중량손실량을 측정하였고 이를 XPS를 이용한 표면분석을 하여 산화휘발거동을 규명하였다. 그 결과 Pt-20%Rh가 가장 우수한 고온산화휘발특성을 보였으며 상대적으로 고온산화휘발특성이 좋지 않은 Pt-Ir 2원계 합금에 Rh를 첨가한 Pt-10%Rh-10%Ir 3원계 합금을 만들어 약 60% 향상된 결과를 얻을 수 있었고 이 결과를 증기압 관점에서 고찰하였다.

  • PDF

환기가 제한된 세 개 격실에서 Pool Fire에 대한 FDS 검증분석 (Validation of FDS for Pool Fire in Three Rooms Connected to Ventilation Network)

  • 배용범;이상규;신병수;김남석;금오현;박종석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.9-15
    • /
    • 2011
  • This study aims to validate predictive capabilities of FDS for the pool fire in three rooms connected to ventilation network. The three rooms in real scale fire test facility are configured to be similar to that of nuclear power plant in size, ventilation condition, construction material, etc. Basically three rooms are confined to the other area except two open doors and two ventilation duct in each room. The real scale fire test was conducted with these conditions and the predictive capabilities of FDS will be validated by comparing FDS simulation results with experimental data from the temperature, heat flux, and concentration point of view. This study concludes that temperature from FDS is about 25 % lower deviation from the experiment, and heat flux from FDS is about 5% deviation.

  • PDF

와송의 HL60백혈병세포의 Apoptosis유도 효과 (Effect of Orostachys japonicus A. Berger on Apoptosis Induction of Human Leukemia HL60 Cells)

  • 오찬호;배진범;김남석;전훈;한광수;이문준;권진
    • 생약학회지
    • /
    • 제40권2호
    • /
    • pp.118-122
    • /
    • 2009
  • Methanol extracts of Orostachys japonicus A. Berger (OAB) were found to exhibit apoptosis induction of HL60 human acute promyelocytic leukemia cells. Treatment of OAB exerted strong cytotoxicity against HL60 cells. OAB induced DNA fragmentation of HL60 cells in a dose dependent manner. Nitric oxide production were also increased in OAB-treated RAW264.7 macrophage cell lines. Treatment of OAB increased the expression of p53 and iNOS gene and the expression of p53, $NF-{\kappa}B$ and iNOS protein in cultured HL60 and RAW264.7 cells. These results suggest that OAB are effective on strong anti-cancer properties and can be useful as a chemo-preventive agents.

TAB 테이프 제조를 위한 구리 도금 및 에칭에 관한 연구 (Cu Electroplating on Patterned Substrate and Etching Properties of Cu-Cr Film for Manufacturing TAB Tape)

  • 김남석;강탁;윤일표;박용수
    • 한국표면공학회지
    • /
    • 제27권3호
    • /
    • pp.158-165
    • /
    • 1994
  • Cu-Cr alloy thin film requires good quality of etching be used for TAB technology. The etched cross sec-tion was clean enough when the etching was performed in 0.1M $FeCl_3$ solution at $50^{\circ}C$. The etching rate was increased with the amount of $KMnO_4$. For enhanced profile of cross section and rate, the spray etchning was found to be superior compared to the immersion etching. A series of experiments were performed to improve the uniformity of the current distribution in electrodeposition onto the substrate with lithographic patterns. Copper was electrodeposited from quiescent-solution, paddle-agitated-solution, and air-bubbled-solution to in-vestigate the effect of the fluid flow. The thickness profile of the specimen measured by profilmetry has the non uniformity at feature scale in quiescent-solution, because of the longitudinal vortex roll caused by the natural convection. However, uniform thickness profile was achieved in paddle-agitated or air bubbled solu-tion.

  • PDF

선형가속기를 이용한 뇌정위 방사선수술시 Isocentric sub system의 기하학적 오차

  • 이석춘;오종영;김남석
    • 대한방사선치료학회지
    • /
    • 제7권1호
    • /
    • pp.45-53
    • /
    • 1995
  • 목적 : 뇌정위 방사선수술은 AVM(ateriovenous malformation)이나 작은 크기의 종양에 1회에 고선량의 방사선을 조사하는 기술이다. 선형가속기를 이용한 방사선 수술을 하기 위하여 최근 본원에 설치한 Philips SL 75-5 선형가속기와 isocentric sub system(ISS)에 의한 뇌정위 방사선 수술에 있어서 표적의 위치선정과, gantry와 couch의 회전시 기하학적 오차가 중요시 되는데 isocentric sub system의 오차를 분석 하였다. 대상 및 방법 : 방사선원으로는 Philips SL 75-5 선형가속기의 5MV 광자선을 사용하였고, 원형의 작은 광자선속을 위하여 isocenter에서의 직경이 26mm인 secondary cone을 gimbal baaring에 삽입하여 사용하였다. 표적의 크기와 좌표를 정하기 위하여 CT나 angio localizer를 이용하고, 표적좌표 선정을 위하여 BRW phantom base와 target pointer를 이용하여 임의의 BRW-coordinator를 바꾸어 가면서 gantry angle와 ISS head 각도를 임의로 바꾸어 가면서 film에 방사선을 조사하였다. 흑화된 film을 view box 위에 놓고 광학판독기구로 film 가장자리의 오차를 scale 확대경으로 측정하여 오차를 분석하였다. 결과 : 표적좌표 선정의 정확도를 확인하기 위하여 임의의 표적좌표에 gantry의 10개각도 ISShead의 10개각도에서 각각 광자선을 조사시켜 film을 이용하여 오차를 측정한 결과 collimator cone의 직경이 26mm일때 전체 평균오차가 0.219+-0.03mm이었다. 결론 : Isocentric sub system은 gantry head와 ISS arm 사이에 gimbal bearing이 있어서 이 부위를 flexible하게 연결함으로 gantry의 회전에 무관하게 정확한 isocenter를 유지시켜 주고 ISS head는 couch와 독립되어 움직이므로 isocentric sub system isocenter의 오차를 최대한 줄일수 있음을 알았다.

  • PDF

정전기 방전에너지에 따른 LPG/공기 혼합물의 폭발특성에 관한 실험적 연구 (Experimental Investigations on Explosion Characteristics of LPG/Air Mixture by Electrostatic Discharge Energies)

  • 김남석;박달재
    • 한국안전학회지
    • /
    • 제26권6호
    • /
    • pp.26-30
    • /
    • 2011
  • Experimental investigations were performed to examine the effects of different electrostatic discharge ignition energies on LPG/air mixture explosions in an explosion chamber. The chamber consisted of 500 mm in length, with a $100{\times}100mm^2$ cross section. Three different ignition energies were used: 0.30 mJ, 46 mJ and 98 mJ. Flame propagations were recorded by a high speed video camera. The results of flame speed and pressure obtained from the different ignition energies were discussed. It was found that as the energy increased, different flame initiations occurred. This caused the time interval in both the flame and pressure developments. It was also found that the flame speed and the pressure were less sensitive to both 0.30 mJ and 46 mJ, except for the ignition energy of 98 mJ.

몰드 변압기에 사용된 절연물의 연면손상 특성에 관한 연구 (A study on the Surface Characteristics of Dielectric for Mold Transformer)

  • 김남석;방영근;송우창;이경호;박하용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.184-185
    • /
    • 2006
  • 환경오염 등으로 최근 자주 발생하는 국지성 집중호우로 인해 건물 중에서 지하 변전실은 가장 먼저 침수가 발생하게 된다. 따라서 본 논문은 지하에 시설된 전기 설비 중 몰드 변압기의 표면이 수분과 같은 불순물에 의해 오염될 경우 절연물에 미치는 영향과 위험성을 알아보기 위한 것으로 건조 시와 수용액 분무 후에 대한 연면손상에 대해 연구하였다. 실험 장치는 고전압 발생장치, 전극, 촬영장치 등으로 구성되었으며, 실험 결과 불꽃의 형상은 건조 시에는 가늘고 강한 빛으로 거의 직선적이고, 수용액 분 후는 산발적으로 광범위하게 나타난다. 방전에 의한 연면손상 특성을 보면 건조 시와 수용액 분무 후 모두 전극 간격이 증가할수록 탄화의 흔적이나 손상의 정도가 감소함을 알 수 있었으며 전반적으로 수용액 분무 후는 건조 시 보다 탄화 및 손상의 정도가 낮은 반면 부위는 광범위한 것으로 나타났다.

  • PDF

지하구내에 설치된 변압기의 연면방전 특성 (The Surface flashover properties of Molded Transformer in Underground Premises)

  • 김남석;송우창;이경호;이명원;방영근;정진수;박하용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2129-2131
    • /
    • 2005
  • 최근 건축물의 대형화로 인해 대용량의 전기설비가 건물의 지하에 설치되고 있지만 전기설비에 대한 특별한 안전 대책 마련이 미비한 실정이다. 본 논문은 지하 구내에 설치된 몰드 변압기가 침수되었을 경우 발생될 수 있는 1차 재해와 2차 재해에 대한 피해를 최소화하기 위한 연구의 기초 단계로 실제 지하구내에 설치된 몰드 변압기를 실험 시편으로 선택하여 거리에 따른 연면 파괴 전압과 전류파형 등을 분석하였다. 분석결과 전극간 간격이 커질수록 연면방전전압이 증가하는 것으로 나타났으며, 방전전류의 피크치도 높아짐을 알 수 있다. 또한, 전극간의 간격이 커질수록 방전시간이 증가하였으며 방전시간의 증가로 인해 절연물의 손상도 증대되었을 것으로 생각된다.

  • PDF