• Title/Summary/Keyword: 기하학적 거리

Search Result 262, Processing Time 0.037 seconds

Wu 불변거리 연구에 관하여

  • 김강태
    • Communications of the Korean Mathematical Society
    • /
    • v.14 no.2
    • /
    • pp.233-286
    • /
    • 1999
  • Berkeley의 H. Wu 교수에 의하여 1993년에 제창된 Wu 거리는 다변수 복소함수론의 기하학적 연구에 중심적인 역할을 하는 여러 불변거리 중 가장 최근에 발견되었다. 짧은 역사에도 불구하고 이 개념의 유용성이 두드러지는 점을 감안하여, 이 연구의 내용과 전망 그리고 여러 관련 문제 등을 소개하려는 것이 이 논문의 목표이다.

  • PDF

A geometric analysis of range measurement error (거리 영상 측정 오차의 기하학적 분석)

  • 윤강식;이병욱;박래홍
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1259-1265
    • /
    • 1997
  • We investigate depth measurement error of a range finder based on triangulation method. Geometric analysis resulted in intuitive understanding of the error sensitivity. We show that the depth error is propostional to the distance between the object andthe camera. The measurement value has the highest accuracy when the line connecting the focal point of the camera and the object is perpendicular to the line joining the object and the light source of herange finder. Also we analyze the error using a perturbation method and verify that the results are identical through an experiment.

  • PDF

Mesh Simplification Algorithm Using Differential Error Metric (미분 오차 척도를 이용한 메쉬 간략화 알고리즘)

  • 김수균;김선정;김창헌
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.5_6
    • /
    • pp.288-296
    • /
    • 2004
  • This paper proposes a new mesh simplification algorithm using differential error metric. Many simplification algorithms make use of a distance error metric, but it is hard to measure an accurate geometric error for the high-curvature region even though it has a small distance error measured in distance error metric. This paper proposes a new differential error metric that results in unifying a distance metric and its first and second order differentials, which become tangent vector and curvature metric. Since discrete surfaces may be considered as piecewise linear approximation of unknown smooth surfaces, theses differentials can be estimated and we can construct new concept of differential error metric for discrete surfaces with them. For our simplification algorithm based on iterative edge collapses, this differential error metric can assign the new vertex position maintaining the geometry of an original appearance. In this paper, we clearly show that our simplified results have better quality and smaller geometry error than others.

Predictions of Rotor and Fan noise in the Frequency Domain (주파수 영역에서 로터 및 팬의 소음 예측)

  • 정춘면;박승철;이덕주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.111-116
    • /
    • 1991
  • 주파수 영역에서 로터의 thickness noise는 블레이드의 여러가지 기하학적인 조건, 즉 블레이드 수, 블레이드의 사잇각, 에어포일의 모양 그리고 반경방향의 블레이드 끝모양에 따라서 해석되어진다. 본 논문은 비 등간격 로터의 기하학적 조건에 따른 음신호의 위상간섭 영향을 고찰하기 위해서 등간격을 이루는 로터에 대해서 해석된 Hanson의 방법을 확장하였다. thickness noise를 6개의 블레이드를 가진 로터에 대하여 15.deg., 30.deg., 45.deg., 비 등간격을 이루는 경우와 각각에 45 tip angle로 sweepback되었을 때 먼 거리의 음향학적 음신호와 그 스펙트럼을 계산하였다.

  • PDF

Measurement of Geometric Errors of an Ultra Precision mMT Using PSDs (PSD를 이용한 초정밀소형공작기계의 기하학적 오차 측정)

  • Kwon, Seol-Ryung;Kweon, Sung-Hwan;Yang, Seung-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Ultra-precision miniaturized machine tools essential for manufacturing accurate machine components in micro/meso-scale have been developed. To realize high accuracy using mMTs, geometric errors, which are considered as the main sources of inaccuracy should be identified and compensated. The conventional systems for measuring geometric errors, such as a laser interferometer, can measure only one geometric error in a single setup and they involve complicated measurement procedures. A measurement system using PSDs is a promising alternative but the measurable range of such systems is limited to the active range of the PSDs. The proposed measurement system using PSDs can overcome the limit of small measurable range. Further, the mounting errors that could occur during set-up process can be avoided. In this paper, an algorithm corresponding to the system was analyzed and experiments were carried out.

Dose Reduction According to Geometric Parameters of Digital Cerebral Angiography (두개부 혈관 조영검사 시 기하학적 특성에 따른 선량 감소 방안)

  • Park, Chan Woo;Cho, Pyong Kon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.399-406
    • /
    • 2019
  • This study aims to find geometric parameters that the radiologist can change from time to time to reduce dose in angiography examinations. Depending on the geometric characteristics, the values calculated by effective dose were compared, while filming in fluoroscopy mode and Digital subtraction angiography, respectively. The study found that the lower the dose was in FPS mode, the lower the dose was reduced to 30-40%. Doses according to the X-ray angle were measured highest in AP View and lower as the angle went in the head direction. The greater the FOV, the higher the dose was 1.2-1.6 times, and the closer the distance between the X-ray tube and the table, the greater the dose was about 10%. Source-image intensifier distance (SID) get longer to 100 mm, dose of each fluoroscopy and Digital subtraction angiography increase up to 25-30%. In conclusion, various geometric characteristics in angiography examinations are parameters that can be applied by radiographers as frequently as possible, and appropriate geometric properties can be considered and applied in various situations, resulting in appropriate dose reduction.

The Analysis of Geomorphologic Instantaneous Unit Hydrougraph by the Channel Network (하도망의 기하학적 특성을 이용한 지형학적 순간단위도 해석)

  • 조홍제;이상배
    • Water for future
    • /
    • v.23 no.1
    • /
    • pp.89-98
    • /
    • 1990
  • This study is developed the runoff analysis method that is used the geomorphologic instantaneous unit hydrograph to the relative role of network geometry in a basin. The quantitative expressions for the geomorphologic characteristics of a basin are used Shreve's link sepration and width function method. The network geometry are used Weibull's distribution as probability model of the width function, the structural characteristics of channel networks and the other geomorphologic parameters for the gaged basin.

  • PDF

Medial Surface Computation of Polyhedra (다면체의 중립면 계산)

  • 이용구;이건우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.833-840
    • /
    • 1996
  • 중립면은 셸 (솔리드 모델) 유한 요소 생성, 로보트 이동 경로 계산, 특징 형상 판별 등에서 사용될 수 있다. 그러나 기존 중립면 계산 알고리즘들은 연립 방정식을 수렴성이 보장되지 않는 수치 해법으로 풀어야 했기 때문에 발전이 미비했다. 본 논문은 복셀-이등분 면의 교자성을 이용한 중립면 계산 알고리즘을 제시한다. 교차성은 보로노이 영역을 사용, 단순한 기하학적 요소간의 거리 비교로 판별한다. 이런 기하학적인 접근 방법은 기본적으로 수렴성 문제가 배제된다.

  • PDF

MCNP코드를 이용한 수분 측정계기의 기하학적 배치

  • 최원철;이석근;황주호;전홍배;양세학;권정광
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.139-146
    • /
    • 1996
  • 도로건설시 다짐조절은 안정성과 내구성 향상에 중요한 의미를 가지며 이러한 다짐조절에 있어서 수분함량의 측정은 매우 중요하다. 이전에는 흙의 수분함량을 측정하기 위한 계기를 설계하기 위하여 주로 실험에 의한 방법을 사용하였으나 본 연구에서는 3차원 모델링이 가능한 MCNP코드$^{(1)}$ 를 이용하여 계측기 설계에 있어서 중요한 설계변수인 방사선원의 위치와 측정계기 사이의 거리 그리고 계기구성요소인 검출기의 위치, 개수, 흡수재, 감속재의 기하학적 구조 등을 계산하여 설정하였다.

  • PDF

Evaluation of image Quality for Radiographic positioning using IEC Radiation Quality & Clinical condition (IEC 선질과 임상조건을 이용한 방사선영상의 품질평가)

  • An, Hyeon;Kim, Changsoo;Kim, Jung-Hoon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.177-178
    • /
    • 2015
  • 디지털방사선영상시스템의 영상 품질을 비교하기 위해 영상의 정량적인 분해능을 나타내는 변조전달함수(MTF), 노이즈 특성을 나타내는 잡음력 스펙트럼(NPS)을 이용하여 영상 품질평가를 하였다. IEC61267 선질을 사용하여 IEC62220-1에서 제시하는 기하학적인 조건과 실제 임상에서 사용되어지는 기하학적인 조건을 사용하여 그리드 및 부가필터, 임상선량을 이용하여 edge 팬텀을 사용하여 MTF, NPS값을 측정하였다. 그리드사용 유 무, 부가필터사용 유 무, kV, 임상선량(mAs), 영상검출기까지의 거리에 따른 MTF 결과는 임상조건 100cm, 180cm과 IEC62220-1 기하학적인 조건 150cm에서 MTF 공간주파수 측정값은 비슷하게 나타났으며, 오히려 임상조건 100cm에서 공간주파수가 높게 나타나는 경우도 있었다. NPS 결과는 선량(mAs)이 증가함에 따라 감소함을 나타내었다. IEC61267 선질을 이용한 영상품질평가에서는 IEC62220-1기하학적인 조건을 이용한 품질평가보다 임상조건 기하학적인 조건을 사용한 영상의 품질이 좋았다. 본 논문의 영상특성 평가 연구 결과들을 바탕으로 향후 IEC 표준의 영상평가에서 제시하는 평가방법보다는 임상 조건을 적용한 영상특성 평가방법을 적용한다면 실제 임상의 디지털방사선영상시스템의 영상품질을 적절하게 유지할 수 있을 것으로 사료된다.

  • PDF