• Title/Summary/Keyword: 기체 헬륨

Search Result 80, Processing Time 0.035 seconds

Performance Test and Calculation of Recirculation Line in Propellant Feeding System (기체공급계 재순환배관의 성능시험 및 계산)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Chung, Yong-Gahp;Han, Sang-Yeop;Kim, Young-Mog
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.2
    • /
    • pp.9-17
    • /
    • 2007
  • The performance test of recirculation line in propellant feeding system was carried out. Liquid oxygen was used as cryogenic propellant and helium was used as recirculation promotion gas. Tests were done in cases at atmospheric pressure and at pressure of 4 barg in the ullage space of propellant tank. Liquid oxygen recirculation flowrate with helium injection flowrate and temperature distribution along the line were measured. There was appropriate helium injection flowrate for gas-lift recirculation system. Test data were used to make calculation program by test data correlation method. In this paper the procedure of calculation was presented and the results were compared to test data.

Thermal Losses Due to Non-ideal Gas Behavior of Helium in VM Heat Pumps (헬륨의 비이상기체 거동에 따른 VM열펌프의 손실)

  • Baik, J.H.;Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.279-287
    • /
    • 1996
  • A cycle analysis is performed to investigate how the non-ideal gas behavior of helium reduces the heating capacity of VM heat pumps. Since the operating pressures of VM heat pumps are as high as 1 to 20 MPa, the compressibility factor of helium becomes clearly greater than 1 and the non-ideal behavior always represents a thermal loss in heating. To calculate the amount of the losses, an adiabatic cycle analysis is performed with the real properties of helium and the net enthaply flows through the two regenerators are numerically obtained. It is shown that the non-ideal gas losses could be as much as 8% in the heating capacity when the operating pressures are greater than 10MPa. The effects of the operating temperatures and the dead volumes on the loss are presented.

  • PDF

대기압 유전격벽방전의 구동주파수 변화에 따른 전자가열 양상 변환에 대한 시뮬레이션 연구

  • Lee, Jeong-Yeol;Bae, Hyo-Won;Sim, Seung-Bo;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.251.2-251.2
    • /
    • 2014
  • 현재 의료 및 표면처리 분야에 많이 이용되고 있는 상온 대기압 플라즈마 중에서 유전체 격벽 방전(DBD) 장치는 비교적 간단한 구조를 가지며 sub-millimeters 사이즈에서도 매우 높은 플라즈마 밀도의 발생 및 유지가 가능하다. 그러나, 현재로선 이러한 Micro DBD의 특성을 실험적으로 분석하는 것은 장비의 한계가 있으므로, Particle-In-Cell 시뮬레이션을 이용하여 중요 플라즈마 변수들을 관찰하였다. 여기서 사용된 중요변수로는 13.56 MHz~600 MHz사이의 인가 주파수를 두었으며, 유전체 표면에서 양이온에 대한 이차전자 방출계수를 고려하였다, 또한 중성기체는 헬륨가스와 아르곤가스의 2가지 중성기체인 경우를 살펴보았다. 이러한 시뮬레이션을 통해 인가전압의 주기 대비 Ion transit time의 비율이 달라짐에 따라 플라즈마 쉬스의 특성변화와 함께 전자 에너지 확률함수(EEPF)의 특성이 달라진다는 것을 확인하고, 이러한 전자 가열 양상의 변화 원리에 대해서 분석하였다. 또한 주파수 비율 조정을 통한 전자온도, 파워, 효율 등을 조절하는 방법의 공학적 가치에 대해 의견을 제시하였다.

  • PDF

Development of a Residual Gas Analyzer Calibration System (잔류기체 분석기 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Kim, J.T.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.91-98
    • /
    • 2007
  • The Korea Research Institute of Standards and Science (KRISS) has developed a residual gas analyzer (RGA) calibration system and measured gas sensitivities for two different types QMSs using nitrogen, argon, and helium. Different gas sensitivities were identified according to mass and pressure, so it was revealed that the gas sensitivity correction is necessary for proper use of mass spectrometers.

Consideration on the helium leak detection in a large vacuum chamber (대형 진공용기의 헬륨 누설검사 방법에 대한 고찰)

  • In, S.R.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.235-243
    • /
    • 2007
  • Nowadays, in our country, large vacuum chambers for huge experimental facilities such as the tokamak fusion device, high power neural beam test stand, and space simulator have been constructed. In such a vacuum chamber of very large size, it is quite complicate to check on leakage quantitatively, while the probability of a leak is relatively high. To investigate the feasibility of applying reliably a helium leak detection to the huge vacuum chambers, and to find a reasonable methodology of choosing an optimum set-up for leak detection, several virtual constructions of the leak detection system have been analyzed by calculating the pressure distribution in the system and the helium level in the sensor part.

Investigation of the Cryogenic Oxidizer Tank Inner Phenomena of Pump-fed Liquid Rocket Engine Propulsion System (터보펌프식 액체추진기관에서의 극저온 산화제 탱크 내부 현상 고찰)

  • 조남경;권오성;정용갑;조인현;김영목;조기주;정영석
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.238-241
    • /
    • 2003
  • In case of liquid rocket using turbopump, the inner pressure of liquid oxygen tank is maintained low, so vaporization of LOX is generally occurred. This vaporization tendency increases as the inlet helium gas temperature is higher. For estimating the amount of helium in the rocket system, the LOX vaporization phenomena should be carefully considered. In this paper, Inner process of LOX tank is analyzed by two phase flow modeling. the vaporization rate and required Helium mass is investigated with varying inlet helium temperature and heat transfer coefficient.

  • PDF

기체 흐름 기술을 이용한 원거리 대기압 질량분석 이미징 기술

  • Kim, Jae-Yeong;Seo, Eun-Seok;Lee, Seon-Yeong;Sin, Mi-Hyang;Jeong, Gang-Won;Mun, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.381.1-381.1
    • /
    • 2016
  • 분석 방법의 간편함과 용이함의 장점은 물론, 시료 전처리 과정이 적어 시료물질의 임의 파괴나 훼손을 방지한다는 이유에서 최근 10년 간 많은 연구가 이루어지고 있는 대기압 질량분석 기술은 기압차이가 없는 대기압 분위기에서 질량분석이 이루어지기 때문에 시료를 질량분석기 입구 바로 앞에 스테이지를 설치하고서 시료를 이온화하는 경우가 대부분이다. 이 때문에 균질하지 않은 시료의 관심 영역을 모니터링하면서 질량분석을 하기에는 어려움이 있으며, 공간 정보를 추가한 질량분석 이미징에 한계가 있었다. 이에 본 연구팀은 질량분석기 입구에 챔버와 보조 펌프를 장착하여 강제로 기체 흐름 일으켜 시료로부터 발생한 이온을 질량분석기 입구로 유도하여, 원거리에서 시료를 이온화해도 질량분석기 입구까지 이온을 성공적으로 전달시키는 방법을 제안한다. 이를 이용하면 분석하고자 하는 시료를 현미경 스테이지 위에 위치시켜 분석하고자하는 부분을 현미경으로 확인하면서 질량분석을 할 수 있으며, 나아가 대기압 질량 분석 이미징 기술을 구현할 수 있다. 대기압 탈착/이온화원은시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 헬륨 플라즈마 젯과 펨토초 레이저를 결합하여 대기압 이온화원을 제작하였다. 이온 전달관은 1/4" (6.35 mm) 외경의 60 cm 길이의 스테인리스 스틸관을 사용하여 질량분석기에서 약 60 cm 떨어진 현미경 위의 시료의 질량분석이 가능하게 했다. 보조 펌프의 계기압과 저온 대기압 헬륨 플라즈마 젯의 헬륨 기체의 유속을 변화시키면서 시료인 PDMS (polydimethylsiloxane) 의 질량 스펙트럼 (m/z 270.314) 세기를 관찰하여 최적의 이온 전달 조건을 찾았다. 추가로 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다.

  • PDF

KSTAR NBI 이온원의 수소 및 헬륨 개스에서의 방전특성

  • 김계령;박선기;오병훈;최병호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.224-224
    • /
    • 1999
  • KSTAR 토카막의 플라즈마 가열을 위한 NBI 장치의 대전류 이온원 방전 특성을 수소와 헬륨 개스를 사용하여 조사하였다. NBI 이온원은 빔 방향과 반대로 가속되는 전자들을 저지하는 전자덤프(electron dump), 병렬로 연결된 32개의 텅스텐 필라멘트(직경 1.5nn0, 영구자석(Nd-Fe)에 의해 만들어지는 강한 cusp 자장으로 둘러싸인 플라즈마 방전실 및 120kV의 에너지를 인가하는 가속부로 이루어지는데, 최대 빔 전류 65A에서 300초의 장시간 운전을 목표로 하고 있다. 수소와 헬륨 개스 분위기에서 안정된 플라즈마를 얻을 수 있는 필라멘트 전류의 파형을 각각 구하고, 기체압력(0.01~0.4 mbar) 및 아크 전류(100~1200A에)에 따른 플라즈마 파라메타 값들을 직경 1mm의 Langmuir probe를 이용하여 측정하였다. 또한 이온원 운전에 중요한 파라메타인 방전실 내의 플라즈마 밀도 분포와 장시간 운전 가능성에 대한 조사도 수행하였다.

  • PDF

기체 크로마토그래피법을 이용한 수소동위원소 분리기술

  • 김광락;구제휴;나정원;정흥석;성기웅;김용익
    • Nuclear Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.93-101
    • /
    • 1996
  • 수소동위원소의 실험과 취급 및 삼중수소 제거시설의 운용이나 더 나아가서 핵융합소재의 관리기술을 위해서는 수소동위원소분만 아니라 그들의 이성질체들에 대한 정성 및 정량분석이 필수적이며 이를 위해 기체크로마토그래피 분리법이 중요한 분석수단으로 활용되어오고 있다. 본 연구에서는 고순도 $H_2및$ $D_2의$ 수소동위원소 기체를 대상으로 하고 상용의 기체크로마토그래피 분석기를 사용하여 분리컬럼 분위기를 액체질소온도로 유지하고 헬륨 케리어기체를 특별제작된 진공-시료주입장치를 통해 펄스주입하여 크로마토그래피 분리실험을 수행하였다. 10%함량의 염화망간으로 부분 비활성화 시킨 산화알루미늄을 고정상으로 선정하여 이성질체의 분리를 억제할 수 있었으며 흡착후 분리용리시간이 단축된 비교적 좋은 수소동위원소 분리조건을 실증하므로서, 저농도 수소동위원소의 정량분석과 고순도 수소동위원소의 분리 및 농축기술 개발을 위한 기초를 마련하였다.

  • PDF

대기압에서 발생시킨 헬륨 플라즈마에서의 산소함유량 증가에 따른 폐암세포의 세포내 활성 산소 종 및 세포주기 변화

  • Jo, Hye-Min;Kim, Seon-Ja;Jeong, Tae-Hun;Im, Seon-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.261.2-261.2
    • /
    • 2014
  • 저온에서 작동하는 대기압 플라즈마 젯은 생체 조직에의 플라즈마 처리를 가능하게 한다. 이에 이온과 전자, 활성 종, 전기장, UV 등을 발생시키는 플라즈마를 암세포에 처리하여 그에 따른 변화를 관찰하였다. 모세관 타입의 젯에 산소를 반응기체로 흘려주어 헬륨 내 산소 함유량에 따른 활성 산소종의 생성을 확인하였다. 대기압 플라즈마에 의해 생성되는 활성 산소 종(OH, O, electronically excited O (1D), O2 ($1{\Delta}g$) 등)이 세포에 산화 스트레스를 유발할 것이라 예상되어 인체의 폐암 세포[Human lung cancer cell, A549]에 펄스파의 헬륨-산소 플라즈마를 처리한 후, 세포 내 활성 산소 종의 증가량을 비교하였다. 그 결과 적은 양의 산소를 추가하였을 때 세포 내 활성 산소 종의 농도가 증가되었다. 이때 플라즈마에서 발생되는 활성 산소 종(Reactive Oxygen Species, ROS)들은 광 방출 스펙트럼(Optical Emission Spectroscopy)로 확인하였고, 세포내 활성 산소 종은 DCF-DA 염색을 통하여 분석하였다. 이러한 헬륨-산소 플라즈마가 세포 성장의 어떠한 시기에 영향을 미치는지를 알아보기 위하여 세포주기 변화를 분석한 결과, 플라즈마 처리 9시간 후부터 G2/M 주기에 머물러 있음을 확인하였다.

  • PDF