• Title/Summary/Keyword: 기체분석

Search Result 1,240, Processing Time 0.027 seconds

Oxidation Kinetics of $UO_2$ Pellets in Defective Fuel Rods and Its Effect on Fission Gas Release (노내 손상 핵연료의 산화거동 및 핵연료 산화가 핵분열기체 방출에 미치는 효과)

  • Koo, Yang-Hyun;Sohn, Dong-Seong;Yoon, Young-Ku
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.90-99
    • /
    • 1994
  • One of the major phenomena occurring in defective fuel rods is the oxidation of UO$_2$ fuel pellets from UO$_2$ to UO$_{2+}$x/ by the oxygen Produced from the dissociation of the steam in the Pellet-to-clad gap, which leads to the enhancement of fission gas release. In this paper, the oxidation kinetics of defective fuel rods was analyzed on the basis of operating conditions of the reactor and defective fuel rod itself. Oxidation kinetics of the fuel pellet was determined under the assumption that the gap is filled with the saturated steam of 150 atm and an enhancement factor for fission gas release was introduced to take into account the effect of fuel oxidation on fission gas release. Comparison with experimental data shows that the enhancement factor predicts well the increased fission gas release due to the oxidation of UO$_2$fuel pellets.

  • PDF

Comparative Analysis and Improvement of the Preparation of Chlorine gas in the Revised High School Chemistry II Textbooks (개정된 고등학교 화학 ll 교과서 실험 중에서 염소의 제법과 성질 실험의 비교 분석 및 개선)

  • Lee, Kwang-Pill;Seo, Hyun-Kyung;Lee, Mu-Sang
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.1
    • /
    • pp.74-80
    • /
    • 2000
  • The purpose of this study is to analyze comparatively and improve the preparation of chlorine gas in the high school chemistry II textbooks on the basis of the revised curriculum. From the results of the preparation experiment of chlorine gas which is commonly dealing with 9 kinds of textbook in the nation, we have found some problems and have suggested the solution of these problems. The problem is the students may inhale the chlorine gas that is to be injurious on the human body, so the research is focused on safe experimental method without inhalation of chlorine gas. The simple conviction method of character in laboratory is to propose at 5 kinds.

  • PDF

Development of Direct Analysis of Metal and Non-metal Ions in Aqueous Samples with the Moderate Power Helium Microwave Induced Plasma (중급 출력 마이크로파 유도 플라즈마를 이용한 금속 및 비금속 수용액시료의 직접 분석법의 개발)

  • Park, Yong-Nam
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.6
    • /
    • pp.699-706
    • /
    • 1991
  • The moderate power (500 W) Microwave Induced Plasma was generated with helium gas and was used for the direct analysis of aqueous samples. Usually, the helium plasma obtained with a modified Beenakker type cavity forms a cylindrical one. Though, by the careful controls of gas flows, a "toroidal" shape plasma could be made but its analytical performances were found to be worse. Using the glass frit nebuliser, the detection limits for metal ions obtained were around 10~100 ppb and that for chloride was about 50ppm.

  • PDF

$SF_6-N_2$ mixture gas hydrates equilibrium and kinetic characteristics ($SF_6-N_2$ 혼합기체에서의 하이드레이트 상평형 조건 및 속도론에 대한 연구)

  • Lee, Eun-Kyung;Lee, Hyun-Ju;Lee, Yoon-Seok;Kim, Soo-Min;Lee, Ju-Dong;Kim, Yang-Do
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.710-710
    • /
    • 2009
  • $SF_6$ 가스는 높은 절연 특성으로 인해 산업공정에서 순수 또는 $N_2$$CO_2$ 가스를 혼합시켜 광범위하게 사용되고 있다. 그러나 $SF_6$ 가스의 지구온난화지수는 $CO_2$ 대비 23,900배로 환경에 치명적인 영향을 줄 수 있으므로, $SF_6$ 가스에 대한 분리 및 처리에 관한 연구가 필요하다. 본 연구에서는 조성에 따른 $SF_6-N_2$ 혼합기체의 3상평형(물-하이드레이트-기체)점을 측정하였다. 측정결과 $N_2$가 더 많이 첨가된 혼합기체일수록 순수 $SF_6$의 상평형 조건보다 더 높은 압력, 더 낮은 온도에서 형성됨을 알 수 있었고 라만분석으로 실제 만들어진 하이드레이트 내에 혼합기체를 확인하였다. 또한 하이드레이트 형성속도 및 회수기체의 조성을 측정하여 분리 및 회수의 효율을 살펴보았다. 본 실험에서 얻어진 결과는 $SF_6$ 혼합기체의 분리 및 처리에 관한 연구의 중요한 기초 자료가 될 것이다.

  • PDF

Enhancement of Gas Transfer Efficiency in an Intravascular Lung Assist Device using Blood Substitutes (혈관내의 폐보조장치에서 혈액대용물질을 사용한 기체전달 효율향상)

  • 김기범;박재관;권대규;정경락;이삼철
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.391-399
    • /
    • 2003
  • Intravascular oxygenation represents an attractive. alternative support modality for therapy originated with acute respiratory distress syndrome(ARDS). However. the clinical study concluded that more gas exchange was needed for intravascular oxygenation to be clinically effective in ARDS treatment. In this study, we tried to enhance gas exchange on the VIVLAD using microencapsulation of hemoglobin and perfluorocarbon emulsion(PFC emulsion). Blood gas measurements were performed by collecting blood samples from the arterial and venous sides of the circuit, and processing them in a blood/gas analyzer. The function of hemosome. blood/hemosome mixed solution. and blood/PFC emulsion mixed solution were tested by an oxygen dissociation curve using a blood/gas analyzer. As a result, it was shown that the oxygen transfer of hemosome and blood/hemosome mixed solution were higher than that of whole blood. Also. it showed that the carbon dioxide transfer of whole blood/PFC emulsion mixed solution was higher than that of others. Therefore, we determined that hemosome and PFC emulsion could increase oxygen transfer and carbon dioxide transfer. respectively.

Synthesis of Highly Selective Polyimide Material and Comparison of Gas Permeability by Molecular Dynamics Study (고선택성 폴리이미드 소재의 합성 및 분자동력학 연구를 통한 기체투과도의 비교)

  • Lee, Jung Moo;Kim, Deuk Ju;Jeong, Moon Ki;Lee, Myung Gun;Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.162-170
    • /
    • 2015
  • In this study, gas permeability of polyimide materials having a various amine group was measured and molecular dynamics was used to analyze the dynamic characteristics of the gas molecules in the polyimide by calculating the position and velocity of the gas molecules with change of the time. The gas permeability of polyimide membrane having substitution site which increase free volume in the polymer was increased. However, polyimide with rigid structure showed decreased gas permeability. As a result of analyzing the change in the gas permeation behavior using molecular dynamics simulations, we confirmed that the results show the same tendency with actual measurements of the gas permeability.

Gas desorption species and quantity from the hot cathode ionization gauges (열음극 전리 진공게이지의 기체이탈 특성)

  • ;;;I. Arakawa
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.201-206
    • /
    • 2003
  • A residual gas analyzer was used to study the outgassing behavior of stainless steel 304 chamber as a function of bake-out temperature up to $235 ^{\circ}C$ and to identify the gas species evolved during turn on and degassing of the three different types of hot cathode ionization gauges. It was found that $H_2O$, CO, and $H_2O$ were the dominent outgassing species in the vacuum chamber during bake-out but finally $H_2$ and CO(mass 28) persisted at room temperature. Dominant outgassing species were also $H_2$ and $H_2O$ while fuming on the ionizations and then $H_2$,$H_2O$ and CO were found to be the main species degassed gauges. It was appeared that the outgassing species and quantity were not agreed to the three different types of hot cathode ionization gauges.

저온 대기압 아크젯의 플라즈마 발생부 물질에 따른 플라즈마 온도 변화 연구

  • Jeong, Hui-Su;Choe, Won-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.339-339
    • /
    • 2011
  • 진공 플라즈마와 달리 개방된 공간에서 방전되는 대기압 플라즈마는 진공상태에서 수행되는 에칭, 증착 등의 복잡한 플라즈마 공정을 경제적이고 신속하게 수행할 수 있어, 최근 들어 연구가 활발히 진행 중이다. 이와 관련하여 He, Ar, $N_2$, $O_2$, Air 등의 여러 종류의 기체를 50 kHz 고전압에서 방전하여 대기 중에서 저온 플라즈마 공정이 가능한 아크젯 타입의 플라즈마 소스를 개발하였다. 개발된 플라즈마 소스에서는 입력전압, 기체유량, 노즐의 구조와 크기 등의 여러 운전변수에 따라 플라즈마의 방전특성이 변화되었다. 특히 본 연구에서는 아크젯의 플라즈마 발생부의 물질성분(SUS, Aluminum, Cupper)에 따른 플라즈마의 기체온도 및 전자여기 온도의 변화를 광방출분광법(OES)를 이용한 Synthetic spectrum method와 Boltzmann plot method을 통해 살펴보았다. 전압-전류 특성곡선, 시간분해 이미지 촬영법, 기체온도 측정법 등을 이용하여 발생된 플라즈마의 물리적인 특성을 분석하였다. 특히 물질의 성분에 따라 발생되는 플라즈마의 기체 및 전자여기 온도가 이차 전자 방출계수 및 물질의 전도도와의 상관관계가 있는지 연구가 진행 중이다.

  • PDF

Molecular Dynamics (MD) Study of Polymeric Membranes for Gas Separation (기체 분리용 고분자 분리막의 분자동력학 연구)

  • Park, Chi Hoon;Kim, Deuk Ju;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.341-349
    • /
    • 2014
  • Molecular dynamics (MD) computer simulation is a very useful tool to calculate the trajectory and velocity of particles (generally, atoms), and thus to analyze the various structures and kinetic properties of atoms and molecules. For gas separation membranes, MD has been widely used for structure analysis of polymers such as free volume analysis and conformation search, and for the study of gas transport behavior such as permeability and diffusivity. In this paper, general methodology how to apply MD on gas separation membranes will be described and various related researches will be introduced.