• Title/Summary/Keyword: 기준 계수

Search Result 2,553, Processing Time 0.031 seconds

Experimental Investigation of the Drag Coefficient of Porous Road Signs (유공형 도로표지의 항력계수에 대한 실험적 연구)

  • Sung, Hongki;Chong, Kyusoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.71-76
    • /
    • 2018
  • Recently, various technologies have been developed for road facilities to reduce the load, some of which use technologies employing perforated plates for wind load reduction. Currently, there are no regulations concerning the drag coefficient of perforated plates for domestic road facilities. In the United States, the regulations regarding the drag coefficient of perforated plates in the 'Minimum design loads for buildings and other structures' were revised based on the studies of Letchford (2001) and Giannoulis (2012). In this study, a wind tunnel test was carried out to analyze the feasibility of applying regulations involving the perforated plates' drag coefficient. The results of the wind tunnel test and the drag coefficient used in the regulation were compared and analyzed. In addition, the reduction effect of the cross area of road signs calculated by applying the drag coefficient was analyzed. The results of the wind tunnel test and the value of the drag coefficient used in the regulation in the US were found to be very similar. Therefore, it was found that it is possible to apply the formula involving the drag coefficient of the perforated plate to the regulation and that the cross area of the perforated plate used for the post of the road sign is reduced by about 9.45% and that of the horizontal post by about 6.45%.

A Study on the Derivation and Sensitivity Analysis of the Adjustment Factor in the Software Cost Estimation Guidelines (소프트웨어 사업대가기준 보정계수의 유도 및 민감도 분석)

  • Byun, Boon-Hee;Kwon, Ki-Tae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.1
    • /
    • pp.61-72
    • /
    • 2008
  • One of the most significant tasks of software development project is to know how much it will be the software development cost in the early stage of software development cycle. The software development environment and technology are changing very rapidly. For accuracy, we should apply those to the software cost estimation. And it is important that we select the suitable adjustment factor and the value of a suitable adjustment factor. For that, this paper have applied the method of AHP. And we have also analyzed the sensitivity of the adjustment factor which is influenced by decision metrics. In conclusion, the value of the application type adjustment factor is responded more sensitively to the data complexity and the control complexity than processing complexity. And the value of the language adjustment factor is responded more sensitively to the supplying manpower and the time of the coding than the time of the debugging. In the future, we will research the selection of an additional adjustment factor and a suitable value of the adjustment factor which are influenced by the environment and the technology of the domestic software development. And then, in the language adjustment factor, we will try to calculate the value about the individual programming language.

Analysis of the Characteristics of Wind Pressure Coefficient Working on Monosloped Roof Surface (편지붕형 지붕면에 작용하는 풍압계수 특성분석)

  • You, Ki-Pyo;Cho, Seul-Gi;Kim, Young-Moon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.4
    • /
    • pp.81-88
    • /
    • 2009
  • Damage on low?rise buildings caused by typhoons and storms is increasing every year. Thus, this study examined the distribution of wind pressure coefficient at each position according to the height of monosloped roof, and measured wind pressure coefficient according to tributary area and compared it with the current wind load standard. We analyzed six areas in order to analyze characteristics at each position of a half span roof, and found that the wind pressure coefficient was around 25% higher at the high comer (HC) than at the low corner (LC). The distribution pattern of peak pressure coefficient at each position was the same as the AIK load standard, but in the results of our experiment, wind pressure was around 40% lower than the load standard at HC and around 37% higher than the load standard at LC.

  • PDF

Analysis of Hydraulic Similarity at Surcharged Square Manhole (과부하 사각형 맨홀에서의 수리학적 상사성 분석)

  • Kim, Jung-Soo;Yoon, Young-Noah;Han, Chyung-Such;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.510-514
    • /
    • 2008
  • 우수 관거 시스템에서 맨홀의 설치 시 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 수두손실의 발생이 필연적일 수밖에 없다. 현재 계획 또는 설계단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 고려하여 설계를 수행하고 있으며, 맨홀에서의 수두 손실은 거의 대부분 고려되지 않고 있다. 단지 맨홀에서의 수두손실을 저감하기 위하여 하수도시설기준(환경부, 2005)상의 단차 및 인버트 규정만 있을 뿐, 우수 관거 설계에 직접적으로 필요한 적절한 맨홀의 손실계수가 제시되지 않고 있는 실정이다. 국외에서는 축소 수리 모형을 이용한 실험과 수치해석 기법 등을 이용하여 맨홀에서의 손실계수를 산정하는 연구가 꾸준히 진행되어 왔으나 국내에서는 맨홀의 손실계수 산정에 관한 연구가 미흡한 실정이며, 더욱이 맨홀에서의 손실계수 산정을 위한 상사성 적용에 관한 연구는 전무한 실정이다. 그러므로 본 연구에서는 맨홀의 축척 변화에 따른 손실계수의 변화를 분석하기 위하여 하수도시설기준(환경부, 2005)의 특 1호(사각형) 맨홀을 각각 1/2과 1/5로 축소 제작하고, 수리실험 장치를 제작하였다. Froude 상사 법칙을 적용하여 1/2의 축소 모형의 실험 조건을 1/5 축소 모형의 값으로 환산하였으며, 각 축소 모형에 대한 수리 실험을 실시하였다. 과부하된 맨홀의 손실계수를 예측하는데 Froude 상사법칙의 사용 가능성을 확인 하였으며, 1/2 축소 모형과 1/5 축소 모형에서 산정된 손실계수 값이 0.45로 일치하고 있으므로 우수 관거 시스템의 맨홀 설계 시, 축소 수리 모형실험에서 산정된 손실계수의 직접적인 적용이 가능하다고 판단된다.

  • PDF

Development of the Damping Coefficients for Weak and Moderate Earthquake Ground Motions

  • Kim, Myeong-Han
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • Most of seismic design code provisions provide the design response spectra for defining design earthquake ground motions. The design spectra in the code provisions generally come under the 5% of critical damping value, which corresponds to the responses of common structure under the design earthquake. Energy dissipation devices and seismic isolation systems became more popular and the design response spectra at higher damping levels are required. Damping coefficients can be effectively used in conversion of 5%-damped design spectra into other damping levels. These coefficients in the current seismic design code provisions are based on the strong ground motion records. Since the weak and moderate earthquake data have different characteristics from those of strong earthquake data, the application of these coefficients should be investigated in the weak and moderate earthquakes zones. In this study, damping coefficients based on the weak and moderate ground motions were developed and compared to those of current seismic design code provisions.

A Study on the Static Eccentricities of Buildings Designed by Different Design Eccentricities (설계편심의 크기에 따른 비틀림 비정형 건물의 최종 정적편심 크기의 비교에 관한 연구)

  • Lee, Kwang-Ho;Jeong, Seoung-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.33-40
    • /
    • 2012
  • To reduce the vulnerability of torsional irregular buildings caused by seismic loads, the torsional amplification factor was introduced by the seismic code. This factor has been applied differently in a variety of seismic codes. In this study, the final static eccentricity, and the lateral and torsional stiffness ratios of buildings designed with different design eccentricities were compared. The increment of the torsional amplification factor resulted in a decrement of the final static eccentricity of the building. However, after reaching the maximum value of this factor, the final static eccentricity of the building increased again. The final static eccentricity of the building designed by multiplying the sum of the inherent and accidental eccentricity by the torsional amplification factor was zero or had a minus value, depending to the position of the vertical element.

Limits of Fully Anechoic Room for Radiated Disturbance Using Correlation Factor (야외시험장과 전자파 완전 무반사실과의 상관계수를 이용한 완전 무반사실의 허용 기준 제안)

  • Lee, Soon-Yong;Chung, Yeon-Choon;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1401-1411
    • /
    • 2010
  • In this paper, we suggested the tolerance limits of FAR(Fully Anechoic Room) using correlation factor between OATS(Open area Test Site) to measure EMI(Electromagnetic Interference) and FAR to measure EMS(Electromagnetic Susceptibility). FAR Project(SMT4-CT96-2133), CISPR/A/665/DTR, and CISPR A/665/DTR documents are analyzed and theoretical correlation factor based on the documents and theoretical equations is drawn. To obtain the experimental correlation factor, EUT(Equipment Under Test) is fabricated as well as measured at the 10 m distance OATS and in the 3 m distance FAR. Also, to suggest the tolerance limits of EUT with multi sources, radiation theory for electric and magnetic dipoles is programmed. We drew the correlation factor for EUT with multi sources through the programs. As the tolerance limits of FAR is newly defined, It can be used alternative test site for OATS to measure EMI, efficiently.

Calibration of Hargreaves Equation Coefficient for Estimating Reference Evapotranspiration in Korea (우리나라 기준증발산량 추정을 위한 Hargreaves 공식의 계수 보정)

  • Hwang, Seon-ah;Han, Kyung-hwa;Zhang, Yong-seon;Cho, Hee-rae;Ok, Jung-hun;Kim, Dong-Jin;Kim, Gi-sun;Jung, Kang-ho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.4
    • /
    • pp.238-249
    • /
    • 2019
  • The evapotranspiration is estimated based on weather factors such as temperature, wind speed and humidity, and the Hargreaves equation is a simple equation for calculating evapotranspiration using temperature data. However, the Hargreaves equation tends to be underestimated in areas with wind speeds above 3 m s-1 and overestimated in areas with high relative humidity. The study was conducted to determine Hargreaves equation coefficient in 82 regions in Korea by comparing evapotranspiration determined by modified Hargreaves equation and the Penman-Monteith equation for the time period of 2008~2018. The modified Hargreaves coefficients for 50 inland areas were estimated to be 0.00173~0.00232(average 0.00196), which is similar to or lower than the default value 0.0023. On the other hand, there are 32 coastal areas, and the modified coefficients ranged from 0.00185 to 0.00303(average 0.00234). The east coastal area was estimated to be similar to or higher than the default value, while the west and south coastal areas showed large deviations by area. As results of estimating the evapotranspiration by the modified Hargreaves coefficient, root mean square error(RMSE) is reduced from 0.634~1.394(average 0.857) to 0.466~1.328(average 0.701), and Nash-Sutcliffe Coefficient(NSC) increased from -0.159~0.837(average 0.647) to -0.053~0.910(average 0.755) compared with original Hargreaves equation. Therefore, we confirmed that the Hargreaves equation can be overestimated or underestimated compared to the Penman-Monteith equation, and expected that it will be able to calculate the high accuracy evapotranspiration using the modified Hargreaves equation. This study will contribute to water resources planning, irrigation schedule, and environmental management.

Evaluation of Acceleration Amplification Factors Based on the Structural Type of Substation for the Seismic Design of Power Facilities (전력설비의 내진설계를 위한 변전소 구조형식에 따른 가속도 증폭계수의 평가)

  • Park, Seong-Jae;Chun, Nakhyun;Hwang, Kyeong-Min;Moon, Jiho;Song, Jong-Keol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.3
    • /
    • pp.159-169
    • /
    • 2020
  • Acceleration amplification factors, which are variables used in the seismic design of power facilities installed inside substation structures, are presented in the seismic design standards of the United States (US), Japan, and Korea. Unlike the coefficients presented in the design standards of the US and Japan, those presented in domestic design standards can be obtained only by performing dynamic analysis when the substation structure has more than four floors. Because most substation structures in Korea have 4-5 stories, the existing acceleration amplification factor is insufficient to be applied to actual substation structures. To suggest an acceleration amplification factor suitable for domestic substation structure types, the acceleration amplification factor was evaluated for seven representative substation structures. The acceleration amplification factors were evaluated by constructing in-structure response spectra based on a study of far-field and near-fault earthquakes. In general, the acceleration amplification coefficients αJ and αA according to the US and Japan seismic design criteria tend to be overestimated compared with the acceleration amplification factors obtained through dynamic analysis based on the study of near-fault and far-field earthquakes.

An Analysis on Correlations between Journal Impact Factor and Research Performance Evaluation Weight (학술지 영향계수와 연구업적 평가비중의 상관성 분석)

  • Yoon, Hee-Yoon;Kim, Sin-Young
    • Journal of Information Management
    • /
    • v.36 no.3
    • /
    • pp.1-25
    • /
    • 2005
  • Journal impact factor(JIF) of the ISI has many limitations and exceptions notwithstanding its great publicity. The purpose of this study is to identify the characteristics and limitations of IF, and to investigate and analyse research performance evaluation weight of academic faculty in Korea, and to make recommendations for the efficient evaluation criteria for Korean academic journal.