• Title/Summary/Keyword: 기밀 성능

Search Result 214, Processing Time 0.025 seconds

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: I. Analytical Modeling and Material Test (초고속 튜브철도 시스템을 위한 튜브 구조물의 기밀성 평가 : I. 해석모델 수립 및 재료 기밀성)

  • Park, Joo-Nam;Nam, Seong-Won;Kim, Lee-Hyeon;Yeo, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • This paper presents a preliminary study for air-tightness evaluation of vacuum tube structures for super-speed tube railway systems. The formula for flow rate of the air caused by the pressure difference of the inside and outside of the tube structure is derived based on Darcy's law. A test is then performed to measure the air-permeability of concrete with various compressive strengths, the result of which is used for analytical simulation of the air intrusion for a tube structure with a preliminarily defined section. It has been shown that concrete with the compressive strength of at least more than 50MPa is recommended for effective operation and maintenance of the vacuum pump systems, as the air-permeability of concrete is inversely proportional to the exponent of its compressive strength.

A Performance Analysis of Secure Communication Method between Terminals in Satellite Communication Environments (위성통신환경에서의 단말간 기밀통신 방안에 대한 성능 분석)

  • 손태식;임진수;이상하;김동규
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 2001.11a
    • /
    • pp.51-55
    • /
    • 2001
  • 늘어가는 정보통신 서비스에 대한 수요를 만족시키기 위하여 현재 유·무선망을 통합하며 지상망과 위성통신망을 연동하는 방안이 사용되고 있다. 위성통신망은 여러 단말들로 구성되어 있으며, 무선 환경에 노출되어 있어 위성통신망 단말들 사이의 보안이 필수적인 요구된다. 따라서 본 논문에서는 Pull과 Push 형태의 두 가지 키 분배 모델과 대칭키, 비대칭키 암호화 알고리즘을 사용하여 위성통신망에서 적합한 단말간 키 분배 모델을 제안하며 그 성능을 분석함으로써 위성통신환경에서의 적합성을 검증하였다.

  • PDF

The ventilation performance of a vertical exhaust duct in a high-rise building (초고층 건물의 입상배기관을 통한 환기성능)

  • 김신도;김경분;황의현;김형수
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.375-376
    • /
    • 2001
  • 건축 기술의 발달과 도시토지 이용의 효율성을 강화하기 위하여 최근에는 초고층 건물이 많이 건설되고 있다. 이러한 초고층 건물은 에너지 절약적인 설계로 높은 기밀성을 가질 뿐 아니라, 외주부 또한 개폐할 수 없는 유리벽에 의하여 구획되므로 자연 환기에 열악한 특성을 지니고 있다. 초고층 건물의 경우 배기시스템으로 중앙집중배기방식을 채택하고 있으며, 중앙배기시스템은 배기입상덕트의 형상 및 규격, 흡출기의 성능, 그리고 기상조건 등 여러 변수들에 의해 영향을 받는다. (중략)

  • PDF

Design and Performance Test of Ventilation Sliencer for PWR Nuclear Power Plant (원자력 발전소용 덕트형 소음기 개발)

  • 김준호;김영찬;유승국;김두훈;이종림;전규식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.488-492
    • /
    • 1997
  • 원자력 발전소의 공조 시스템에 설치되는 덕트형 소음기를 설계.제작하여 감음성능 시험, 내진해석, 내진시험, 난연시험 및 기밀시험 등을 수행하여 각각의 요구조건에 적합한 소음기를 설계.제작한 결과 원자력 발전소에 기 설치된 소음기와 동등한 성능을 갖는 것으로 나타났다. 소음기를 설계, 제작, 시험하는 과정에서의 노-하우를 바탕으로 어떠한 요구조건에도 만족하는 제품을 국내에서 설계.생산할 수 있는 기술 확보에 있다.

  • PDF

Airtightness performance evaluation of ultra-high performance concrete using polymer coating materials (그래핀을 활용한 폴리머 도막재료의 물리적 특성 평가)

  • Lee, Hyun Seung;Kim, Kang Min;Yoon, Seob;Seo, Tae Suk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.257-258
    • /
    • 2023
  • In this study, it was conducted to improve the physical properties of VAE polymer matrix used as a coating material. A nanocomposite was manufactured using graphene as a reinforcing agent based on a VAE matrix. As a result, improvements in tensile strength, adhesion strength, and porosity were confirmed.

  • PDF

Compliant Mechanism Topology Optimization of Metal O-Ring (금속오링씰의 컴플라이언트 메커니즘 위상최적설계)

  • Kim, Geun-Hong;Lee, Young-Shin;Yang, Hyung-Lyeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.537-545
    • /
    • 2013
  • The elastic recovery of a metal seal is a factor that can be used to assess its sealing performance. In this study, a compliant mechanism topology optimization has been performed to find a structure of a metal O-ring seal that can maintain excellent sealing performance with a maximized elastic recovery over extended operation. An evolutionary structural optimization (ESO) was used as a topology optimization algorithm with two different types of objective functions considering both flexibility and stiffness. In particular, a circular design domain was adopted to consider the outer shape of the metal O-ring seal. The elastic recovery of the optimal topology was calculated and compared to that of a commercial product.

An evaluation on sealing performance of elastomeric O-ring compressed and highly pressurized (압축 및 내압을 받는 고무 오링의 기밀 성능 평가)

  • Park, Sung-Han;Kim, Jae-Hoon;Kim, Won-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.86-93
    • /
    • 2009
  • Elastomeric O-rings have been the most common seals due to their excellent sealing capacity, and availability in costs and sizes. One of the critical applications of O-ring seals is solid rocket motor joint seal where the operating hot gas must be sealed during the combustion. This has long been a design issue to avoid the system failure. For laterally constrained, squeezed and pressurized condition, deformed shape of O-ring was measured by computed tomography method and CCD laser sensor, compared with numerical calculations. As clearance gap changes, sealing performance had been evaluated on peak contact stresses at top, bottom and side contact surfaces. As clearance gap increases, peak contact stresses and contact widths in top and side contact surfaces increase, and the asymmetry of stress distributions is promoted due to pressure increase. It is suggested that peak stress of bottom contact surface can be approximated by simple superposition of peak ones due to squeeze and pressure. Under pressurized condition, sealing performance is dependent on not peak stresses of bottom and side contact surfaces but that of top.

Study on the Establishment of Large Building Airtightness Measurement Standards (대규모 건물의 기밀성능 측정기준 수립에 관한 연구)

  • Lee, Dong-Seok;Ji, Kyung-Hwan;Jo, Jae-Hun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.117-124
    • /
    • 2014
  • Airtightness standards using fan pressurization method are normally used for measuring small buildings, detached houses, and apartment units. And, it is easy to conduct airtightness measurement through this fan pressurization method. However, it can be difficult to achieve accurate measurement results for the large buildings as the height and volume of the buildings have been increased. In this paper, we studied the principle of airtightness method by fan pressurization. And, we reviewed the measurement process described in ISO 9972, EN 13829, ASTM E779, ATTMA TS 1, CAN/CGSB 149.15, and JIS A 2201. Then, we categorized the methods' items according by air flow rate (Q) and pressure difference(${\Delta}P$). As a result, we made a comparison analysis on the measurement methods appeared in each standards. And, we achieved 5 test conditions about air flow rate and pressure difference to state requirements for large buildings airtightness measurement.

A Study on the Airtightness Performance of New Han-ok Bedrooms (신한옥 침실 공간의 기밀성능 평가 연구)

  • Lee, Ju-Yeob;Jang, Hyeon-Chung;Lee, Tai-Gang;Song, Min-Jeong;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

Seasonal Contribution of Indoor generated- and Outdoor Originating PM2.5 to Indoor Concentration Depending on Airtightness of Apartment Units (공동주택의 기밀성능에 따른 실외 유입 및 실내 발생 PM2.5의 계절별 실내농도 기여도 분석)

  • Park, Bo Ram;Choi, Dong Hee;Kang, Dong Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.2
    • /
    • pp.155-163
    • /
    • 2020
  • Indoor airborne particles are consisted of outdoor- and indoor-generated particles, which can be characterized by their compositions, generation features and toxicity. The identification of source contribution of indoor and outdoor origin to indoor particles is important to understand PM2.5 transport in a building as well as its impact on occupant health. The objective of this study is to investigate seasonal source contribution to indoor PM2.5 concentration depending on airtightness of apartment units. To evaluate the source contribution, particle transport including penetration, generation, exfiltration in an apartment housing unit was simulated by using CONTAM with particle and airflow simulation parameters obtained from field measurements. The result showed that the outdoor source contribution to indoor air was relatively dominant in the leaky housing unit during spring (77.2%) and winter (73.9%), and the indoor source was dominant in the airtight housing unit during summer (60.3%) and fall (60.7%). These results indicate the seasonal health risk of indoor PM2.5 can be varied according to airtightness of apartment units.