• Title/Summary/Keyword: 기밀 성능

Search Result 214, Processing Time 0.034 seconds

자료

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.8 s.221
    • /
    • pp.89-93
    • /
    • 1987
  • PDF

Performance Evaluation of Cryptographic Algorithms for the 6LoWPAN with Packet Fragmentations (6LoWPAN 단편화 패킷 재전송에 따른 암호화 알고리즘 성능 분석)

  • Kim, Hyun-Gon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.8
    • /
    • pp.77-84
    • /
    • 2011
  • In this paper we implement a 6LoWPAN protocol on the MICAz sensor platform, which could minimize packet re-transmission, and support security primitives for packet integrity and confidentiality. And we also present a performance evaluation of the implemented protocol calculated according to the cryptographic algorithms. In the re-transmission method, time stamp, nonce, and checksum are considered to protect replay attacks. As cryptographic algorithms, AES, 3DES, SHA2, and SHA1 are implemented. If transmission errors (thus, packet losses) and the number of hops are increase then, packet re-transmissions are increase exponentially from the experimental results. Also, the result shows that cryptographic operations take more time than packet re-transmission time.

Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea (국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발)

  • Bae, Minjung;Choi, Gyeongseok
    • Land and Housing Review
    • /
    • v.11 no.3
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

A Study of Influence on System Performance due to Access Control Mechanism in UNIX System (접근제어 방식이 유닉스시스템 성능에 미치는 영향에 대한 연구)

  • Jung Chang-Sung;Lee Kwang-Hyun;Lee Hoi-Sun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.967-970
    • /
    • 2006
  • 정보 보호의 목표는 정보자산의 기밀성, 무결성, 가용성을 보장함으로써 정보시스템의 신뢰성과 안전성을 확보하고 이를 통하여 기관이나 조직에서 추구하는 사업에 대한 영속성 보장의 기반을 제공하는 것이다. 접근 제어는 정보 보호의 목표인 기밀성, 무결성을 하기 위한 수단으로 많이 사용된다. 즉, 인가받지 않은 주체에게는 접근을 허용하지 않고, 인가된 주체에 대해서는 신뢰성 있는 정보를 제공하기 위해 정보에 대한 접근 제어를 한다. 그러나 가용성 측면을 무시하고 기밀성과 무결성만을 지나치게 강조할 경우 사용자에게 제공되는 정보는 이미 과거의 정보가 되어 아무런 가치가 없을 수도 있다. 이에 본 논문에서는 정보 보호의 3대 목표를 모두 만족하는 접근제어 시스템을 구축하는데 있어서 바람직한 방향을 제시하고자 한다.

  • PDF

The Solenoid Valve Development Tests for Propellant Tank Pressurization System (추진제 탱크 가압용 솔레노이드 밸브 개발 시험)

  • Kim, Byung-Hun;Koh, Hyeon-Seok;Kwon, Oh-Sung;Han, Sang-Yeop
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.813-816
    • /
    • 2011
  • The actuation and leakage tests of solenoid valve for propellant tank pressurization system have been conducted. The response time of solenoid valve manufactured is satisfactory to perform requirement. However, leakage was found at the upper part seat of relief valve inside solenoid valve. Solenoid valve was disassembled in order to discover leakage causes. We found out that the upper seat of relief valve was damaged. Through this study, the development possibility of propellant tank pressurization solenoid valve was confirmed.

  • PDF

A Study on Industrial Security Outflow Prevention System Based on Network Biometric Authentication (네트워크 바이오 인증 기반 산업기술 유출방지 시스템에 관한 연구)

  • Lee, Dae-Sung
    • Convergence Security Journal
    • /
    • v.11 no.4
    • /
    • pp.31-36
    • /
    • 2011
  • Enterprise which has a core technology or organization which manages a core information will be walking into a critical situation like a ruins when organization's confidential information is outflowed. In the past confidential information that was leaked to the off-line, recently the outflow made possible through a variety of equipment at any time via the network based on the ubiquitous communication environment. In this paper, we propose to authenticate and block all packets transmitted via the network at real-time in order to prevent confidentials outflow. Especially in or der to differentiate between users who attempt to disclose confidentials, we propose to insert user's biometric informaion transparently at per-packet basis, and also verify a performance by simulation.

Design and Implementation of Stream Cipher based on SHACAL-2 Superior in the Confidentiality and Integrity (기밀성과 무결성이 우수한 SHACAL-2 기반 스트림 암호 설계 및 구현)

  • Kim, Gil Ho;Cho, Gyeong Yeon
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1427-1438
    • /
    • 2013
  • We have developed a 128-bit stream cipher algorithm composed of the 5-stage pipeline, capable of real-time processing, confidentiality and integrity. The developed stream cipher is a stream cipher algorithm that makes the final 128-bit ciphers through a whitening process after making the ASR 277 bit and SHACAL-2 and applying them to the CFB mode. We have verified the hardware performance of the proposed stream cipher algorithm with Modelsim 6.5d and Quartus II 12.0, and the result shows that the hardware runs at 33.34Mhz(4.27Gbps) at worst case. According to the result, the new cipher algorithm has fully satisfied the speed requirement of wireless Internet and sensor networks, and DRM environment. Therefore, the proposed algorithm with satisfaction of both confidentiality and integrity provides a very useful ideas.

Field Measurement of Infiltration in New Apartments using De-pressurization Method (신축 공동주택에서 감압법을 이용한 기밀성능 실측 연구)

  • Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2013
  • Infiltration is air flow that occurs through cracks in buildings. According to level and kind of infiltration, the cooling load and heating load in buildings may increase. In this study I conducted field measurements to evaluate air tightness in 27 new apartment units. Field measurements for new apartments was the focus. For the de-pressurization method, the equipment utilized to gauge airtightness included KNS-5000C and KNS-4000 which were installed on the window in order to measure indoor air leakage. The results are summarized as follows. The average ACH50 of a $59m^2$ APT was 3.98, 3.82 for a $84m^2$ APT, and 2.73 for a $114m^2$ APT. The total average ACH50 of 27units was 3.51.

Security consideration of DLC on Internet (Internet을 이용한 DLC 시스템의 보안)

  • 이재인;배두현;송오영;박세현
    • Proceedings of the Korea Institutes of Information Security and Cryptology Conference
    • /
    • 2003.12a
    • /
    • pp.376-385
    • /
    • 2003
  • 본 논문에서는 인터넷을 이용한 DLC 시스템의 보안 방안에 대한 연구와 제안된 시스템의 성능평가 내용을 기술한다. 이 논문에서는 DLC 시스템만이 아닌 다양한 제어 시스템에서의 보안 시스템 구성이 가능한 방법을 제안하였다. DLC 시스템의 보안 요소는 데이터 기밀성과 무결성, 부인 방지, 제어장치와 서버간의 상호인증이다. 데이터 기밀성과 무결성은 SSL을 통해서 해결하고 제어장치와 서버간의 상호인증은 PKI 서명을 통해서 해결하였다. 또한, DLC 시스템과 같은 close system에서 사설 PKI의 사용을 통한 시스템 성능향상에 대해 살펴본다.

  • PDF

A Study on the Correlation between Air-tightness and Sound Insulation in the Apartment Housing (공동주택에서 기밀성능과 차음성능과의 상관성 연구)

  • Park, Cheol Yong;Hong, Gu Pyo;Choi, Ji Hye;Lee, Yong Dae;Choi, Jun Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.296-297
    • /
    • 2013
  • We have investigated correlation between airtightness measured by blower door and airborne sound insulation measured in the upper and lower units. We consist of two cases : all windows sealed(CASE 1) and not sealed(CASE 2). As a result, CASE 1 is tighter than CASE 2 in airtightness, but CASE 1 is lower than CASE 2 in sound level difference. This is because of big wind on measuring CASE 1. Thus we are going to measure them at another fields considering this factor. Finally we ought to find out the correlation between airtightness and sound insulation.

  • PDF