• Title/Summary/Keyword: 기밀성시험

Search Result 64, Processing Time 0.037 seconds

Air-tightness Evaluation of Tube Structures for Super-speed Tube Railway Systems: II. System Test and Parametric Analysis (초고속 열차 시스템을 위한 튜브 구조물의 기밀성 평가 : II. 시스템 실험 및 파라메터 해석)

  • Park, Joo-Nam;Kim, Lee-Hyeon;Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.2
    • /
    • pp.151-159
    • /
    • 2011
  • This study performed an experimental study for air-tightness performance evaluation of concrete tube structures with joints. The test specimens consist of a continuous concrete tube, a concrete tube with a joint in the middle, and a segmented concrete tube. The test is performed in such a way that the inner pressure of the tube is dropped down to 0.1atm and the increase of the pressure is monitored with time. An equivalent air permeability is then calculated based on the test results. The results show that, as expected, a structure with more joints or bonds tends to be less air-tight. A sensitivity study shows that the system air-tightness performance level becomes higher as either the diameter or the thickness of the tube increases. Moreover, the increase in the diameter or the thickness of the tube makes an effort to enhance the air-tightness more effective.

A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels (수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chuung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.63-70
    • /
    • 2015
  • Crevices between window and window frame cause not only heat losses but also serve path to sound transmission and infiltration of fine dusts that are harmful to humans. There were many efforts in the past to eliminate these crevices but because of the windows' indispensable function of opening and closing, it was an unsolvable problem. In this study, a new type sliding window is developed by applying horizontally rolling wheels to implement a surface sealing which is excellent for enhancing air tightness. To evaluate the feasibility of the newly developed window, forces for opening and closing, durability and air tightness were testet according to Korean Testing Standards. Force for opening a 2000 N window is 30 N. It endured 100,000 cycles of opening and closing. Infiltration was $0.00m^3/(m^2h)$ for a pressure difference of 10 Pa. Since this window has few moving parts, it has favorable features of low cost and few breakdown.

Development of Pressure Correction System for Surface Vessel to Ensure Reliability of Compartment Test Result (수상함 격실기밀시험 결과의 신뢰성 확보를 위한 압력 보정 시스템 개발)

  • Min, Il-Hong;Kim, Jun-Woo;Son, Gi-Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.409-414
    • /
    • 2021
  • Tightness performance that blocks compartments is important for surface ships to achieve superior mission performance and survivability in combat environments. To meet the above requirements, airtightness of the structural elements and the appropriate strength to specific areas are checked during a test run after ship construction. In particular, air tests of compartments adjacent to the water surface are performed. In an air test, air is injected into the compartment up to the test pressure of the test memo. The pressure drop value is checked after 10 minutes to determine if the requirements of the corresponding area are satisfied. In summer, however, when the influence of the outside temperature is large, a phenomenon in which the internal pressure increases during the air test was identified. This phenomenon reduces the reliability of the test result. Therefore, a system was designed to compensate for temperature changes in the compartments through this study. The developed system calculates the amount of pressure change caused by a temperature change in the compartment and outputs a correction value. The pressure change was calculated using the ideal gas equation, reflecting the maintenance, increase, and decrease in temperature during the test process. A comparison of the calculated pressure correction value with the database of NIST REFPROP revealed a difference of 0.126% to a maximum of 0.253%.

Development and Design of Pulse Gun for Combustion Stability Rating Test (연소 안정성 평가 시험을 위한 펄스건 설계 및 개발 시험)

  • Go,Yeong-Seong;Lee,Gwang-Jin;Lee,Su-Yong;Lee,Dae-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.103-109
    • /
    • 2003
  • The development of a pulse gun used for the combustion stability rating test(SRT) has been domestically tried out since the SRT should be accompanied in the process of the development of LREs. At the beginning of the development, a rupture problem of the pulse gun body had been solved by changing its material and increasing its thickness. Also, the sealing test was undertaken for a pulse gun equipped with a membrane before conducting a explosion test and by using a specially designed jig after a explosion test. Since it is appropriate to reuse the holder of a pulse gun cavity for an actual SRT, a series of experiments for several variants has been taken to make it reusable. After all, the solution for a reusable holder of a pulse gun has been found and applied for complementing its specification.

자동차용 방열기의 수명분포 추정

  • Hong, Yeon-Ung;Gwon, Yong-Man
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.177-180
    • /
    • 2003
  • 본 연구에서는 자동차용 방열기의 수명분포를 일반적으로 기계류에 적용하는 와이블분포라 가정하고 실험실 데이터를 이용하여 추정한다. 방열기 수명시험시 고려해야할 요소를 방열량, 기밀성, 내압 성능, 압력캡 시험 등 11가지로 정하고 이에 대한 신뢰성 관점에서의 해석 및 MINITAB을 이용한 추정을 주요내용으로한다.

  • PDF

Conformance Testing Tool Implementation for XML Encryption Products (XML 암호화 제품을 위한 표준적합성 시험도구 구현)

  • Chae Han-Na;Rhee Gwang-Soo
    • The KIPS Transactions:PartC
    • /
    • v.13C no.4 s.107
    • /
    • pp.435-440
    • /
    • 2006
  • XML encryption is to provide confidentiality service, though not limited to, for web contents. XML encryption can be applied to entire data files as opaque objects, or more frequently to various parts of XML documents, supporting various encryption granularity. It is this characteristic that makes XML encryption a more efficient alternative for data confidentiality in various web applications than is possible with SSL/TLS, IPsec, PGP, or S/MIME. It is essential for successful deployment of XML encryption to achieve interoperability among the products implementing this technology, which requires the products to implement the XML encryption standards correctly. Conformance testing is to test if products implement the relevant standard correctly. In this paper we present a conformance testing method for XML encryption products and implement it. We will first look at XML encryption standards developed by W3C, and extract test criteria. Then we propose a testing method in which the encryption capability and the decryption capability of a product are tested separately. The proposed methody is actually implemented as a GUI-based testing tool and some test results are presented.

Evaluation of Micro-defects and Air Tightness of Al Die-casting by Impregnation of Organic Solvent (유기용제 함침법을 통한 알루미늄 다이캐스팅의 미세결함 및 기밀성 평가)

  • Lee, Jin-Wook;Cho, Chang-hyun;Kim, Sung-Gye;Ko, Young-Gun;Kim, Dong-Ju
    • Journal of Korea Foundry Society
    • /
    • v.42 no.4
    • /
    • pp.218-225
    • /
    • 2022
  • For hydrogen-vehicle applications (air pressure control valve housing, APCVH), an investigation was conducted to determine how micro-defects in a high- pressure die-casted Al alloy (industrial code: ALDC12) could be controlled by means of a post-treatment using an organic-based impregnation solution in order to improve the air- tightness of the die-casted Al sample. Two different impregnation solutions were proposed and its test results were compared to a imported product from Japan with respect to the processing variables used. A structural investigation of the components under study was conducted by means of computer tomography and 3D X-ray micro-CT. These observations revealed that the use of the impregnation treatment to seal micro-defects led to highly significant and beneficial changes which were attributed mainly to interconnections among inherent micro-pores. A leak test after impregnation revealed that the performance improvement rate of the die-casted Al sample was ~70% for INNO-01. Therefore, the developed impregnation solutions offer an effective strategy to control the micro-defects found in various vehicle parts via die-casting.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

Reliability Assessment of Medium Voltage Gas Insulated Switchgear (배전용 가스개폐기 신뢰성 평가 연구)

  • Kwon, Tae-Ho;Kim, Dong-Myung;Lee, Do-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2089_2090
    • /
    • 2009
  • 본 논문은 한전에서 사용되는 25.8kV 가스 절연 부하개폐기(이하 개폐기)에 대해 장기과통전시험, 부하전류 개폐 및 접점마모시험, 가스 기밀재 가속열화시험을 통해 신뢰성을 평가하였다. 국내 개폐기의 신뢰성 및 수명에 대한 척도를 평가한 결과, 모든 시료가 $B_{10}$ 수명 20년 이상을 보증할 수 있는 것으로 나타났다.

  • PDF