• Title/Summary/Keyword: 기둥부재

Search Result 498, Processing Time 0.02 seconds

Species Identification of Wooden Elements Used for Daewungbojeon Hall in the Magoksa Temple, Gongju (공주 마곡사 대웅보전 목부재의 수종분석)

  • Kim, Soo-Chul;Jang, Jin-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.3
    • /
    • pp.295-303
    • /
    • 2015
  • Daewungbojeon hall of Magoksa temple is a korean traditional wood building well representing Joseon Dynasty architecture in the 17th century. The purpose of this study was to identify the wood species of 42 wooden elements collected from Pillar (Gidung), Head-penetrating tie (Changbang), Pyeongbang, Angle rafter (Chunyeo), End-angle rafter (Sarae) and Hwalju. According to the microscopical investigation, Pillar, Head-penetrating tie, Pyeongbang and Hwalju were identified as domestic hard pine species. However, Chunyeo were identified as either Zelkova serrata Makino or Gingko biloba L. and Sarae as exotic hard pine species. It might be related to the high replace rate of wood elements for the roof. Especially, exotic hard pine species seem to be replaced in recent years when Daewungbojeon hall was repaired.

Nonlinear Finite Element Analysis of Reinforced Concrete Planar Members Using Rotating Orthotropic Axes Model (이방향성 회전 직교축 모델을 이용한 철근콘크리트 면부재의 비선형 유한요소해석)

  • 박홍근
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.117-127
    • /
    • 1995
  • The objective of this research is to investigate the effectiveness of rotating orthotropic axes model in analyzing reinforced concrete planar members under cyclic as well as monotonic loading. The structural members to be addressed are moderately reinforced beams, columns, beam-column joints, and shear walls, whose failure occurs due to compressive crushing after extensive crack propagation, The rotating orthotropic axes model which is usually used for monotonic loading is developed for cyclic loading. With the existing cyclic material models of reinforcing steel and bond-slip, this material model is used for the finite element analysis. For monotonic loading, the analytical results of the rotating orthotropic axes model are compared with reinforced concrete beams which have brittle failure. For Shear wall members under cyclic loading, the analyses are compared with the experiments for the ultimate load capacity, nonlinear deformation, and pinching effect due to crack opening and closing.

  • PDF

Species Identification of Wooden Elements Used for Daewungjeon Hall in the Woonsoosa Temple, Busan (부산 운수사 대웅전 목부재의 수종 식별)

  • Kim, Ji-Yeong;Lee, Mi-Ok;Park, Won-Kyu
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.244-250
    • /
    • 2014
  • This study was conducted to identify wood species of 72 wooden parts (pillar, beam, jangyeo, purlin, judu, soro, bracket, deagong, ceiling panel, etc.) used for Daewungjeon Hall in the Woonsoosa Temple, Busan in Korea. Identified wood species were 67 Pinus spp. (Kesiya group), 4 Carpinus spp. and 1 Quercus spp. (Cerris group). In pillars, 14 red pines and 4 Carpinus and in purlins, 4 red pines and 1 Cerris were found. Other elements were red pines. Carpinus woods, which were used for the lower portions of three pillars (Dongbari), seemed repaired parts. A carved wood used for the stand of Buddhist statues was identified as Alnus spp. This study showed that Daewungjeon Hall of the Woonsoosa Temple was made mostly of red pines.

Difference of Deterioration According to Exposed Condition of Column in Wooden Traditional Building (노출 환경에 따른 목조 고건축물 기둥의 열화 차이)

  • Kim, Gwang-Chul;Bae, Mun-Sung;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.58-68
    • /
    • 2003
  • Capacity assessment of structural member must be ahead of the safety assessment of wooden traditional building. Capacity assessment of structural member has been dependent on empirical method with visual inspection even now. Safety assessment of building, however, can be more correct and reasonable provided non-destructive evaluation technique that scientific and logic would be used to evaluate the capacity of structural member. For that purpose, non-destructive evaluation technique was applied to column among many structural members of wooden traditional building to examine the possibility of capacity assessment of structural member. And then, those data will be used as a basic data for capacity assessment of structural member in a following study. Specially, deterioration progress levels of column according to exposed condition were measured. Similar results were obtained as compared with results of visual inspection, so there was a good possibility of application for non-destructive evaluation technique.

Design of Fire-Resistance in RC Structure Buildings (콘크리트 구조물의 내화설계)

  • 김화중
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.2
    • /
    • pp.30-36
    • /
    • 2002
  • 콘크리트가 화재에 노출될 경우 가열에 의한 재질의 노화 및 열팽창에 의한 열응력의 발생에 따라 주요구조부인 기둥 및 보에 큰 손상이 생기게 되어 그 내력은 크게 저하하게 된다. 철근 콘크리트 구조물의 화재 상황을 조사해 보면 (그림 1)과 같이 열응력에 의한 기둥의 전단파괴, 보의 휨파괴 및 부재의 폭열 등이 보여진다.(중략)

A Study on the Prediction of the Strength and Axial Strain of High-Strength Concrete Columns Confined by Tie Reinforcement (띠근 보강 고강도 콘크리트 기둥의 강도 및 축변형 특성 산정에 관한 연구)

  • Park, Hoon-Gyu;Jang, Il-Young
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.197-208
    • /
    • 1999
  • The use of high-strength concrete which permits smaller cross sections, reduced dead loads, and longer spans has been getting more popular in tall buildings. However, there has been little research on behavior of high-strength concrete columns laterally reinforced with square ties and subjected to compressive loading. With the addition of transverse reinforcement which lead to triaxial compressive state, ductility behavior of high-strength column member shall be increased. In this study, rational quality and quantity evaluations were made to investigate the ultimate strength and strain ductility by confinement effect of tie reinforced high-strength concrete columns subject to uniaxial loads. Concrete failure theory at the triaxial compressive state and statistical results based on conventional experimental data were applied for this propose. Up to 185 columns, tested under monotonically increasing concentric loading, were evaluated in terms of strength and strain ductility. Analytical results show that confinement stress, maximum compressive strength, and increase of strain equations were developed with the consideration of concrete strength, yield strength, spacing, volumetric ratio, and configurations of tie reinforcement.

Behaviour of the Reinforced Concrete Columns with Shear Reinforcement (전단보강량에 따른 철근콘크리트 기둥의 거동)

  • Nam, Sang-Uk;Song, Han-Beom;Tae, Kyung-Hoon;Yi, Waon-Ho;Oh, Sang-Hoon;Yang, Won-Jik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.45-48
    • /
    • 2008
  • Under earthquake loads, the columns on the lower stories carry large axial forces and horizontal forces as the earthquake loads are acting horizontally and vertically on the building. To distribute the energy entered into the building under earthquakes according to the plastic deformation of the members, it is safer and more economic to persuade plastic hinge to occur in the beams rather than on the columns. However, it is unavoidable to have plastic hinge occurring on the columns when it is applied on both of the main axes of the building, which results in high shear force on the column end, and reinforced concrete column may result in sudden brittle failure due to bending moment and shear force. To increase restriction of the reinforced concrete column on the horizontal forces, this study uses repetitive loading experiments with different amount of shear reinforcement, and analyzes and compares the structural safety and behaviour of the reinforced test materials.

  • PDF

An Experimental Study on the Behaviours of Hollow CFT Column Subjected to Axial Load (중공 콘크리트충전 각형강관 기둥의 거동에 관한 연구 (I. 중심 압축실험))

  • Kim, Cheol-Hwan;Kim, Jong-Kil
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.69-76
    • /
    • 2006
  • Concrete Filled Steel Tube (CFT) system is advantageous because it increases the load-carrying capacity without increasing the size of column. However CFT system has many benefits, it is not applied to field generally because of its heavyweight and difficulty of concrete filling method. As a solution to these problems, we proposed concrete filled steel tube column with hollow made by factory-manufactured PC method. The hollow concrete filled steel tube system is expected to obtain the high strength and high capacity of deformation despite it is a lightweight. This study deals with mechanical properties, strength and deformation, of hollow concrete filled steel tube subjected to axial load. 9 specimens were tested to examine mechanical properties closely, and the following results were obtained: All specimens basically showed higher initial rigidity and maximum strength with increased concrete filling rate. And most specimens showed almost linear behavior until around 80% of maximum strength regardless of filling rate, it is estimated that the elastic range is up to a half of the maximum strength which is the yield strength level.

  • PDF