• Title/Summary/Keyword: 기둥보강

Search Result 466, Processing Time 0.033 seconds

Dynamic Analysis of Structures with Continuous Transverse Reinforcement Applied (연속 횡방향철근을 적용한 구조물의 동적 해석)

  • Cho, Kyung Hun;Han, Soo Ho;Lee, Jung Bin;Kim, Sung Bo;Kim, Jang Jay Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.277-285
    • /
    • 2023
  • Recently, as the magnitude and frequency of earthquakes increases, research is needed to increase the ductility of the columns in order to prevent the collapse of structures. In this study, to evaluate the performance of columns reinforced with continuous transverse reinforcing bars, the FE model for the dynamic analysis of structures reinforced with continuous transverse reinforcing bars for circular and rectangular columns is to be verified using the results of uniaxial compression experiments in the previous study. As a result, the experimental value of the column reinforced with continuous transverse reinforcement and the result value related to the dynamic analysis showed similar behavior, and the reliability was high. As a result of the analysis, the usability of the rectangular column reinforced with continuous lateral reinforcing bars was confirmed because the dissipated energy performance of the columns reinforced with spiral reinforcing bars was higher than that of the columns reinforced with band reinforcing bars.

Evaluation of Compressive Strength of Assembled Column System Reinforced with Cross-Arms and Stayed Struts (수평재 및 사재로 보강된 조립기둥시스템의 압축강도 평가)

  • Kim, Kyung Sik;Park, Hyun Yong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.6
    • /
    • pp.2169-2179
    • /
    • 2013
  • The compressive strengths of simply supported columns may be significantly increased by reinforcing them with an assemblage of cross-arms and stayed struts connecting both ends of the columns and the cross-arm members. The purpose of the stayed struts and cross-arms is to introduce partial restraints against translation and rotation, thereby decreasing the effective buckling length of the column. In this study, buckling strengths of the assembled column system have been quantitatively evaluated from the theoretical methods based on both the equivalent spring model and the stiffness matrix formulation. And the results were compared with those from elastic/inelastic analysis using a finite element analysis package program, ABAQUS, for verification purpose. Expected compressive strength curves have been proposed for the assembled column system as a function of slenderness ratio of the simply supported column.

Behaviors of Hollow R.C Columns with Internal Steel Tube by Hollow Ratio (강관으로 보강된 중공 R.C 기둥의 중공비에 따른 거동)

  • Choi, Jun-Ho;Yoon, Ki-Yong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.106-110
    • /
    • 2006
  • 중공 R.C 기둥은 중실 R.C 기둥에 비해 자중의 감소나 재료의 절감의 장점을 가지고 있다. 하지만 중공 R.C 기둥은 안쪽면의 취성파괴로 인하여 낮은 연성 거동을 할 가능성이 있다. 이러한 문제점을 해결하기 위해 중공 부재 내의 콘크리트 3축 구속 상태로 존재하게 하는 강관으로 보강된 중공 R.C 기둥이 강영종, 한택희 (2005) 등에 의해 개발되었다. 본 연구는 강관으로 보강된 중공 R.C 기둥에 대하여 중공비를 0.5~0.85까지 변화 시켜 중공비에 따른 작용하중에 대한 안전율, 연성도, 재료비에 대한 거동 특성을 파악하였다.

  • PDF

Strengthening Effects of RC Column using Fiber Reinforced Polymer (섬유보강재를 이용한 RC 기둥의 보강 효과)

  • Lee, Hyun-Ho;Kim, Jin-Ho;Rho, Kwamg-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.4
    • /
    • pp.473-480
    • /
    • 2012
  • In order to develop an effecive seismic strengthening metghod for existing concrete structure, structural tests of aramid FRP reinforced RC columns are performed. The test variables were strengthening methods of aramid sheet and strip. The test results were evaluated by comparing strength and energy dissipation capacities of non-reinforced and reinforced specimens. The test result comparison showed that aramid sheet reinforcement on RC column was evaluated as the most efficient way to increase strength and energy dissipation capacity.

An Experimental Study on the Flexural Behavior of Reinforced Concrete Columns Strengthened with Wire Rope and T-Shape Steel Plate units (와이어로프와 T형 플레이트에 의해 보강된 RC 기둥의 휨 거동에 대한 실험적 연구)

  • Sim, Jae-Il;Yang, Keun-Hyeok;Oh, Sung-Jin;Byun, Hang-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.153-156
    • /
    • 2008
  • The objective of the present study is to evaluate the flexural behavior of reinforced concrete columns externally strengthened with wire rope and T-shape steel plate units. Three strengened columns and a control unstrengthened column were tested under cyclic lateral load simultaneously subjected to a constant axial load. All columns had same section size, and the arrangement of longitudinal reinforcement and internal hoop. The spacing of wire rope range from 40 ${\sim}$ 80mm, which corresponds from 1.0 ${\sim}$ 0.5, respectively, times the minium amount of hoop specified in seismic design of ACI 318-05. Test results showed that the proposed unbonded-type strengthening procedure is very effective for improving the flexural ductility of reinforced concrete columns.

  • PDF

Axial Behavior of Reinforced Concrete Columns Externally Strengthened with Unbonded Wire Rope and T-Shaped Steel Plate (와이어로프와 T 강판으로 비부착 보강된 철근콘크리트 기둥의 중심 축하중 거동)

  • Yang, Keun-Hyeok;Sim, Jae-Il;Byun, Hang-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.221-229
    • /
    • 2008
  • An improved unbonded-type column strengthening procedure using wire rope and T-shaped steel plate units was proposed. Eight strengthened columns and an unstrengthened control column were tested under concentric axial load. The main variables considered were the volume ratio of wire rope and the flange width and configuration of T-shaped steel plates. Axial load capacity and ductility ratio of columns tested were compared with predictions obtained from the equation specified in ACI 318-05 and those of conventionally tied columns tested by Chung et al., respectively. In addition, a mathematical model was proposed to evaluate the complete stress-strain relationship of concrete confined by the wire rope and T-plate units. Test results showed that the axial load capacity and ductility of columns increased with the increase of the volume ratio of wire rope and the flange width of T-plates. In particular, at the same lateral reinforcement index, a much higher ductility ratio was observed in the strengthened columns having the volume ratio of wire rope above 0.0039 than in the tied columns. A mathematical model for the stress-strain relationship of confined concrete using the proposed strengthening procedure is developed. The predicted stress-strain curves were in good agreement with test results.

Numerical Study on the Estimation of Surface Constrained Pressure for Ductile Behavior of RC Columns (RC 기둥의 연성거동을 위한 표면구속응력 산정에 관한 해석적 연구)

  • Kim, Kyeong-Min;Lee, Su-Young;Kim, Geon-Woo;Kwon, MinHo;Kim, JinSup
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.3
    • /
    • pp.48-56
    • /
    • 2021
  • Due to the recent earthquake that has occurred worldwide, interest in seismic reinforcement of structures is increasing. In order to improve the seismic performance of the structure, the seismic reinforcement of the column should be made. Various seismic retrofit methods are being developed to improve the seismic performance of columns. In this study, in order to improve the seismic performance of RC columns, an numerical study was conducted to evaluate the seismic performance of the columns by applying a surface constrained pressure. For the numerical study, the experimental study on the column was used, and the failure shape and behavior characteristics of the experimental results and the numerical results were compared. As a result of the numerical study, the ductile behavior of the RC columns occurred according to the strength of the surface constraining stress. In addition, ductile behavior occurred almost constant above a certain surface constrained pressure. Compared with the numerical results and the experimental results, he reinforcing effect of the used seismic reinforcement of the column in experimental study was compared with the value of the surface constrained pressure for the RC column, and the seismic reinforcing effect was examined as the surface constrained pressure value for the RC column. In conclusion, in this work, surface constrained stress and constrained strength for ductile behavior of RC columns are derived. Based on the results derived, it is believed that it can be used as basic data on the review of seismic design methods and seismic performance complementary effects using ductile behavior induction of RC columns.

Numerical Evaluation of Geosynthetic Reinforced Column Supported Embankments (개량체 기둥지지 성토공법의 지오그리드 보강효과에 대한 수치해석)

  • Jung, Duhwoe;Jeong, Sidong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.2
    • /
    • pp.13-22
    • /
    • 2021
  • Pile or column supported embankments have been increasingly employed to construct highway or railway embankments over soft soils. Piles or columns of stiffer material installed in the soft ground can provide the necessary support by transferring the embankment load to a firm stratum using a soil arching. However, there has been reported to occur a relatively large differential settlement between the piles and the untreated soils. Geosynthetic reinforced pile or column supported embankment (GRPS) is often used to minimize the differential settlement. Two dimensional finite element anlyses have been performed on both the column supported embankments and the geogrid reinforced column supported embankments by using a PLAXIS 2D to evaluate the soil arching effect. Based on the results obtained from finite element analyses, the stress reduction ratio decreases as the area replacement ratio increases in the column supported embankments. For the geogrid reinforced column supported embankments, the geogrid reinforcemnt can reduce differential settlements effectively. In additon, the use of stiffer geogrid is appeared to be more effective in reducing the differential settlements.

Study on Reinforcement Effect of Circular RC Columns by Helical Bar Under Cyclic Lateral Load (반복 횡하중을 받는 원형 철근콘크리트 기둥의 Helical Bar 보강효과에 대한 연구)

  • Kim, Seong-Kyum;Park, Jong-Kwon;Han, Sang-Hee;Kim, Byung-Cheol;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.1
    • /
    • pp.48-58
    • /
    • 2014
  • In this study, quasi-static according to the displacement-controlled (strain control) method tests on RC columns for seismic reinforcement performance in accordance with the provisions of the seismic design and construction before 1992 design code for highway bridges in korea. Used reinforcement that improves the performance of Inorganic Helical Bar, a kind of alloy steel, circular columns were tested outside the seismic reinforcing. In the experiment, fracture behavior, lateral load-displacement relation, ductility and energy assessment evaluation was performed through tests. The variables in experimental are section force of reinforcement, spiral reinforcement spacing, reinforcement method. Improved seismic performance and effect were confirmed through quasi-static test experiments. The results of study confirmed determination the appropriate size of reinforcement, reinforcement forces, spacing and selection of the type required, furthermore, not only mechanical reinforcement but also substitution of high-strength concrete reinforced with concrete cover improved seismic performance.

Tensile Behavior of Concrete-Filled Square Steel Tubular Column-Beam Flange Connections with Stiffeners (강관 보강형 충전 각형강관 기둥-보 플랜지 접합부의 인장거동에 관한 실험적 연구)

  • Yoo, Yeong Chan;Kang, Hyun Sik;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2001
  • The purpose of this study is to examine the utility of concretefilled steel tubular column to H-beam connections with tubular stiffener. As a preliminary step. a tensile experiment was undertaken to scrutinize characteristics of the structural behavior that take place between beam flanges and column with tubular stiffener. A total of 4 types of experimental settings were developed as tabular stiffeners are made up 9, 18, and 27 mm of thickness and 50 and 80 mm of height respetively Along with the overall load subsequently the degree of displacement and strain were recorded. Based on the yield line theory results of this of this study were evaluated and further critically reviewed the applicability of the strength formula. This study found that collapse mechanism was emerged on the beam flange as reinforcing tabular stiffeners Complementary studies of this sort, including numerical analyses should be undertaken in order to develope specific design critera.

  • PDF