• Title/Summary/Keyword: 기둥기울기

Search Result 8, Processing Time 0.028 seconds

Free Vibrations and Buckling Loads of Axially Loaded Cross-Ply Laminated Composite Beam-Columns with Multiple Delaminations (다층간분리된 직교 적층 보-기둥의 자유진동과 좌굴하중)

  • 이성희;김형열;박기태;박대효
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.523-534
    • /
    • 2002
  • Free vibration and buckling analysis of multi-delaminated composite beam-columns subjected to axial compressive load is performed in the present study In order to investigate the effects of multi-delaminations on the natural frequency and the elastic buckling load of multi-delaminated beam-columns, the general kinematic continuity conditions are derived from the assumption of constant slope and curvature at the multi-dclamination tip. The characteristic equation of multi-delaminated beam-column is obtained by dividing the global multi-delauunated beam-columns into segments and by imposing recurrence relation from the continuity conditions on each sub-beam-column. The natural frequency and the elastic buck)ing load of multi-delaminated beam-columns according to the incremental load of axial compression, which is limited to the maximum elastic buckling load of sound laminated beam-column, are obtained. It is found that the sizes, locations and numbers of multi-delaminations have significant effect on natural frequency and elastic buckling load, especially the latter ones.

Numerical Analysis of Four Circular Columns in Square Array and Wave Interaction (파랑과 정사각형 배열의 원형 기둥 구조물의 상호작용 수치해석)

  • Song, Seongjin;Park, Sunho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.558-565
    • /
    • 2017
  • Accurate prediction of wave-structure interactions is important in the safety and design cost effectiveness of fixed and floating offshore structures exposed to extreme environmental conditions. In this study, regular waves and circular column structure interactions for four circular columns in regular waves are analyzed. To simulate 3D two-phase flow, open source computational fluid dynamics libraries, called OpenFOAM, were used. When the four circular columns are arranged in a square array, the interactions according to the incident slopes of the regular waves are analyzed. The wave run-up in the circular column surface was compared according to the slope of the incident wave. It was confirmed that high amplitude waves are generated between the circular columns due to the interaction between the circular column and the incident wave. It is expected that this analytical result will be used as the basic data of the study on the air gap due to the interaction between the structure and incident wave.

Evaluation of the Soil-Structure Interaction of a MDOF Column Type Structure on Group Piles Based on the Large Scale 1g Shaking Table Test and the Numerical Analysis (대형 진동대 실험 및 수치해석을 이용한 다자유도 기둥 구조물과 군말뚝 기초의 지반-구조물 상호작용 평가)

  • Chae, Jonghoon;Yoon, Hyungchul;Ahn, Jaehun;Jung, Jongwon
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.4
    • /
    • pp.47-58
    • /
    • 2022
  • Many 1g shaking table tests with an SDOF structure supported by a single pile were performed to evaluate the soil-structure interaction (SSI) effect. Since most structures supported by group piles are MDOF structures with columns, the SSI effect is simulated using a large 1g shaking table test and numerical analysis. According to the results, the movement in the piles tends to increase with input acceleration and when the input frequency is similar to the natural frequency. Furthermore, the slope of the dynamic p-y curve remains constant regardless of the variation of acceleration and input frequency. According to the results of the dynamic p-y backbone curve and the moment of group piles, a center pile with a leading pile has more soil resistance than side piles with a trailing pile, and the effect of group piles is observed above the 7D center to center pile distance.

Mathematical Model for Acousto-Optical Tomography and Its Numerical Simulation (음향광학 단층촬영(Acousto-Optical Tomography)의 수학적 모델과 수치해석적 시뮬레이션)

  • Nam, Hae-Won;Hur, Jang-Yong;Kim, So-Young;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.42-47
    • /
    • 2012
  • In this paper, Acousto-Optical tomography is modeled by a linear integral equation and an inverse problem involving a diffusion equation in n-spatial dimensions. We make two-step mathematical model. First, we solve a linear integral equation. Assuming the optical energy fluence rate has been recovered from the previous equation, the absorption coefficient ${\mu}$ is then reconstructed by solving an inverse problem. Numerical experiments are presented for the case n=2. The traditional gradient descent method is used for the numerical simulations. The result of the gradient descent method produces the blurring effect. To get rid of the blurring effect, we suggest the total variation regularization for the minimization problem.

Post-Buckling of Shear Deformable Uniform Columns Under a Combined Load (조합하중을 받는 전단변형 기둥의 좌굴 후 거동 해석)

  • Yoo, Yeong Chan;Shin, Young Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.313-320
    • /
    • 2003
  • The governing equation of the post-buckling of shear-deformable uniform columns under a combined load consisting of a uniformly distributed axial load and a concentrated load at a free end was derived and the post-buckling analysis was investigated by using differential transformation. The loads were obtained for various end-slopes. The results obtained by the present method agree well with published results. In this paper, the differential transformation method was illustrated through its application to the non-linear differential equation of the post-buckling. It is expected that applications of the method to more challenging problems will are expected follow in future to ensue.

A Study on the Fatigue Line with Plastic Rotaional Angle for Steel Structure of the Beam-to-Column Joints (기둥-보 연결 강구조물의 소성회전각에 의한 피로곡선 연구)

  • Kong, Byung Seung
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.2 s.35
    • /
    • pp.221-232
    • /
    • 1998
  • This study presents a fatigue line with a plastic rotational angle to a great extent of plastic strain of Low-Cycle-Fatigue period, such as earthquake, etc. This fatigue line with a plastic rotational angle is measured and analysed more simply in practice rather than Woehler's fatigue line which is developed in stress variation of the structure. It shows that the slope of fatigue line with a plastic rotational angle is equal to that with plastic strain through the experiments by proving the correlation that the plastic strain ratio is directly proportional to the plastic rotational angle in plastic hinge. The theory is induced by Manson and Coffin strain fatigue line, and the experiments are tested by ECCS. The location of the plastic hinge is achieved and accurate plastic strain ratio is calculated through FEM.

  • PDF

Effect of the Eave Width and the Vertical Rain Proof Facilities on Ventilation and Air Velocity Distribution in Hanwoo Loose Barn (개방한우사의 처마와 수직 비가림시설이 환기와 풍속 분포에 미치는 영향)

  • Lee, Seung-Joo;Jo, Hyeon-Jun;Kim, Dong-Hoon;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.45 no.4
    • /
    • pp.87-93
    • /
    • 2011
  • This study was carried out to determine more effective way in eave structure between lengthening roof just as standard plan and replacing 3 types of vertical rain roof facility by using computational fluid dynamics (CFD) simulation to reduce the heat stress of Hanwoo, increase the effect of dryness of room floor, rain proof and ventilation efficiency. The simulation which did with mean wind velocity (1.2 m/s) result showed that the case of lengthening of roof just as standard design was more effective than the cases of vertical establishment of rain proof facility.

A Study on the Installation of the Optimized Collapse Risk Detection Monitoring System for Small-Scale Private Buildings (소규모 민간 건축물을 위한 최적의 붕괴 위험 감지 모니터링 시스템 설치 방안 연구)

  • Heejae Kim;Geunyoung Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.147-155
    • /
    • 2024
  • Purpose: The purpose of this study is to analyze the danger signs of buildings and present a plan to install a building monitoring system to develop measurement technology for small private buildings in the blind spot of disaster safety. Method: The cause of building risk behavior, components of monitoring measuring equipment, location of measuring equipment installation, management plan, etc. are presented. Result: Measuring instruments essentially include acceleration sensors, tilt sensors, gyro sensors, GPS, etc. The measuring instrument should take into account the height and cross-sectional area of the pillar. Conclusion: The results of this study can strengthen disaster safety capabilities in preparation for disasters arising from building collapses that may occur in small private buildings.