• Title/Summary/Keyword: 기대비가동시간

Search Result 5, Processing Time 0.018 seconds

교체정책에 대향 베이지안 접근법

  • Jeong, Gi-Mun
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.319-326
    • /
    • 2006
  • 본 논문에서는 최소수리를 갖는 수리가 가능한 시스템의 최적의 교체정책에 대한 베이즈 접급방법을 제안하였다. 특히, 시스템을 운용하는데 필연적으로 발생하는 비용과 비가동시간을 함께 고려하여 기존의 비용에 근거한 연구결과를 확장하고자 하였다. 이를 위해서 단위시간당 기대비용과 단위시간당 기대비가동시간을 구하고, 이 두 기준을 동시에 고려한 최적의 교체주기를 결정하는 방법을 제시하였다. 또한, 순응적 교체정책에 대해서도 살펴보았다.

  • PDF

A Bayesian approach to replacement policy following the expiration of non-renewing combination warranty based on cost and downtime (비재생혼합보증이 종료된 이후의 비용과 비가동시간에 근거한 교체정책에 대한 베이지안 접근)

  • Jung, Ki-Mun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.21 no.5
    • /
    • pp.873-882
    • /
    • 2010
  • This paper considers a Bayesian approach to replacement policy following the expiration of non-renewing combination warranty. The non-renewing combination warranty is the combination of the non-renewing free replacement warranty and the non-renewing pro-rata replacement warranty. We use the criterion based on the expected cost and the expected downtime to determine the optimal replacement period. To do so, we obtain the expected cost rate per unit time and the expected downtime per unit time, respectively. When the failure times are assumed to follow a Weibull distribution with uncertain parameters, we propose the optimal replacement policy based on the Bayesian approach. The overall value function suggested by Jiang and Ji (2002) is utilized to determine the optimal replacement period. Also, the numerical examples are presented for illustrative purpose.

Maintenance Policy Based on Cost and Downtime Following the Expiration of Combination Warranty (혼합보증이 종료된 이후의 비용과 비가동시간에 근거한 보전정책)

  • Jung, Ki-Mun
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.6
    • /
    • pp.909-923
    • /
    • 2008
  • This paper considers the replacement model and the preventive maintenance model following the expiration of combination warranty for a repairable system. If the system fails after the combination warranty is expired, then it is minimally repaired at each failure. The criterion used to determine the optimal replacement policy and the optimal preventive maintenance policy is the overall value function based on the expected cost rate per unit time and the expected downtime per unit time. The numerical examples are presented for illustrative purpose when the failure time follows a Weibull distribution.

Development of BNR(Biological Nutrient Removal) Process Using Expanded Polystylene(EPS) Media (Expanded Polystylene(EPS) 여재를 이용한 BNR(Biological Nutrient Removal) 공정 개발)

  • Ryu, Hong-Duck;Min, Kyung-Kook;Lee, Jeong-Hun;Choi, Kyoung-Young;Lim, Heun-Eun;Kim, Chul-Hwan;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Biological nutrient removal(BNR) process used in this study, which was packed with EPS(expanded polystylene) media, has more many advantages in aspect of reducing hydraulic retention time(HRT) of the process and having less effect of temperature in the winter season than commercial process in the present. Bench-scale study was performed using domestic wastewater. In the results, it was observed that the T-N removal efficiencies in HRT 6 hr and HRT 4 hr were 55% and 51%, respectively, showing the small reduction (about 4%) of T-N removal efficiency according to shortening of HRT. In comparison of T-N removal characteristic in summer and winter seasons, it showed that T-N removal efficiencies in summer and winter seasons were 65% and 54%, respectively, showing the 11% lower T-N removal efficiency in winter season than in summer season due to deterioration of nitrification in winter season. In the studies of influent loading rate and C/N ratio, the process showed stable effluent quality under the condition of broad influent loading rate and C/N ratio. Therefore, it is anticipated that the developed process in this study could be applicable to small wastewater treatment plant in nutrient removal.

Printable Time Temperature Integrator Consisting of Oxygen Indicator and Cover Film with Various Oxygen Permeability (다양한 산소 투과도를 가진 커버필름과 산소지시물질로 제작된 인쇄형 TTI)

  • Kim, Do Hyeon;Jang, Han Dong;Han, Seo Hyeon;Ahn, Myung Hyun;Lee, Seung Ju
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.24 no.2
    • /
    • pp.41-48
    • /
    • 2018
  • A printable time temperature integrator (TTI) consisting of oxygen indicator and cover films with various oxygen permeability was developed. The printing ink contained methylene blue (oxygen indicator) which changed in color during storage. $TiO_2$ and glycerol for UV-activation of TTI and zein and ethanol for printing performance were also contained in the printing ink. The cover film on the ink was employed to control the color change rate and temperature dependency (Arrhenius activation energy, $E_a$) by using the different films (PE, PET, OPP, and LLDPE). The film properties were varied by annealing. TTI was produced by silk screen printing. As a result, the color change rates were different for the cover films, being the highest in TTI with LLDPE, followed by OPP, PE, and PET. The rate decreased with increase in the cover film thickness. The $E_a$ was the highest in TTI with LLDPE, followed by OPP, PE, and PET. The $E_a$ did not change with the cover film thickness. The annealed PVC and PET film were lower in oxygen permeability than the unannealed ones, indicating the lower color change rate.