• 제목/요약/키워드: 급탕량

검색결과 22건 처리시간 0.022초

공동주택의 적정 급수.급탕량 산정 모델 (Estimation model of reasonable amount of domestic cold water and hot water supplies in apartment houses)

  • 김성남;하태웅
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.758-765
    • /
    • 1999
  • The estimation of reasonable amount of domestic cold water and hot water supplies in apartment houses is very important for the economical design of domestic cold water and hot water supply system which include pumps, boilers, heat exchangers, and various water reservoirs. To suggest the model of predicting reasonable amount of domestic cold water and hot water supplies, residents and actual domestic cold water and hot water consumption have been investigated for 740 apartment houses in Seoul and Bun-Dang, Kyunggi-Do. The model is suggested as a function of exclusive area of the apartment house and results of the model show generally good agreement with published data.

  • PDF

기숙사 태양열 급탕시스템의 열성능에 관한 실증연구 (An Experimental Study on the Solar Hot Water Heating System for the Dormitory of University)

  • 신우철;백남춘;곽희열;주현로
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.103-109
    • /
    • 2006
  • The Purpose of this work is to investigate a long-term thermal performance of active solar hot water heating system for the dormitory of university. For this, monitering system including temperature sensors, flow-meters was installed in this system. Measurement was continued for 13 months between April 1st 2004 and May 31th 2005. As results, hot water demand, daily and monthly hot water load distribution which are necessary for the solar system design were suggested. Also thermal stratification in solar buffer tank was observed in the point of increasement of system efficiency. The yearly solar fraction and system efficiency of this system are about 29.5% and 44.9% respectively.

고정식과 방위추적식 태양열 급탕시스템의 집열성능 비교 (Comparison of Heat Collection Performance of Water Heating System Using Fixed and Azimuth-Tracking Solar Collectors)

  • 이종석
    • 대한기계학회논문집B
    • /
    • 제38권2호
    • /
    • pp.191-196
    • /
    • 2014
  • 강릉원주대학교는 캠퍼스 내에 저탄소 녹색기술 아이템들을 설치하였다. 그 중에 태양열 급탕시스템은 태양열 집열판을 고정식과 방위추적식의 두 가지 방식으로 설치하였으며, 기존의 고정식 집열판과 새로운 방위추적식 집열판을 사용하는 급탕시스템의 집열량을 비교하기 위해 모니터링을 실시하였다. 본 논문에서는 태양열 급탕시스템의 구성 및 모니터링 시스템을 소개하고 모니터링 결과를 통해 고정식과 방위추적식 태양열 집열판을 사용한 두 가지 급탕시스템의 집열성능을 비교하였다. 방위추적식의 집열량이 고정식보다 맑은 날에는 19%, 비온 날에는 23%, 평균 21% 만큼 더 크다는 것을 보여준다.

아파트에서의 적정 급수.급탕량 산정법 (Estimating of reasonable amount of cold and hot water supplied in an apartment house)

  • 김석중;김성남
    • 대한설비공학회지:설비저널
    • /
    • 제28권4호
    • /
    • pp.276-289
    • /
    • 1999
  • 최근 들어, 생활수준의 향상과 인구의 증가로 인하여 서울 주변에는 위성도시가 건설되고 이러한 위성도시의 완성으로 공동주거(아파트)의 관심은 날로 높아져 가며, 생활양식의 변화로 인하여 건축물에서 생활용수의 사용량이 급격히 증가하고 있다.

  • PDF

주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구 (A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings)

  • 차민철;제성호;석호태
    • 한국주거학회논문집
    • /
    • 제19권1호
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.

유량제어방식에 따른 태양열 급탕시스템의 열성능 평가 (Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.

나주지역의 태양열 설비의 모니터링에 관한 연구 (The Study of Monitoring Characteristics of a solar heat system with Naju)

  • 신영식;정성찬;최정식;차인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1078_1079
    • /
    • 2009
  • 본 논문에서는 태양열 온수급탕에 관한 모티너링 연구를 해석하고 이론을 바탕으로 실 시스템을 적용 운용시 시스템의 운전특성을 비교 분석하였다. 장기 적인 일사량 측정 데이터 수집을 통하여 그래프화, 모티터링 시스템에 관한 연구를 살펴보았다.

  • PDF

법령과 고시 - 친환경 주택 건설기준 및 성능 고시

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권233호
    • /
    • pp.55-57
    • /
    • 2009
  • 국토해양부는 지난 10월 20일 20가구 이상의 공동주택을 건설할 경우 총에너지를 종전보다 10~15% 이상 절감토록 하는 내용의 '친환경 주택의 건설기준 및 성능'을 고시하고 이날부터 시행에 들어갔다. 국토부는 친환경적인 주택 건설을 위한 제도적 기반을 구축하기 위해 에너지 소비절감 및 탄소배출량 감소를 위한 에너지절약형 친환경 주택의 건설기준 및 성능을 마련한 것이다. 이 고시는 친환경 주택으로 인정받기 위한 필수시설 및 각각의 설치기준 제시와 에너지 사용용도에 따라 난방, 급탕, 전력, 열원 등 4개로 분류하는 친환경주택 성능 평가방법 등을 규정했다.

  • PDF