• Title/Summary/Keyword: 금속 접착

Search Result 196, Processing Time 0.025 seconds

Effect of 3-Isocaynatopropyl Triethoxy Silane on PU Adhesive (3-Isocaynatopropyl Triethoxy Silane이 PU 접착제에 미치는 영향)

  • Ju, Honghee;Jang, Euisub;Park, Chan Young;Lee, Won-Ki;Kim, Taekyun;Chun, Jae-Hwan
    • Journal of Adhesion and Interface
    • /
    • v.14 no.1
    • /
    • pp.36-42
    • /
    • 2013
  • To improve hydrolytic stability of polyurethane (PU) adhesives, a silane coupling agent (SCA) was added. 3-Isocyanatopropyl triethoxy silane (ITS) as a SCA has two functional groups in the main chain and it is used to improve an interfacial interaction between polymer and inorganic material or metal. In this study, PU adhesives with different amounts of ITS from 0 to 1 wt% were synthesized. Pot time, modulus, thermal stablilty, and adhesive force of the obtained samples were measured. The results showed that the adhesives with ITS showed better properties than that of pure one.

Effect of cavity shape, bond quality and volume on dentin bond strength (와동의 형태, 접착층의 성숙도, 및 와동의 부피가 상아질 접착력에 미치는 영향)

  • Lee, Hyo-Jin;Kim, Jong-Soon;Lee, Shin-Jae;Lim, Bum-Soon;Baek, Seung-Ho;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.450-460
    • /
    • 2005
  • The aim of this study was to evaluate the effect of cavity shape, bond quality of bonding agent and volume of resin composite on shrinkage stress developed at the cavity floor. This was done by measuring the shear bond strength with respect to iris materials (cavity shape , adhesive-coated dentin as a high C-factor and Teflon-coated metal as a low C-factor), bonding agents (bond quality: $Scotchbond^{TM}$ Multi-purpose and Xeno III) and iris hole diameters (volume; 1mm or 3mm in $diameter{\times}1.5mm$ in thickness). Ninety-six molars were randomly divided into 8 groups ($2{\times}2{\times}2$ experimental setup). In order to simulate a Class I cavity, shear bond strength was measured on the flat occlusal dentin surface with irises. The iris hole was filled with Z250 restorative resin composite in a bulk-filling manner. The data was analyzed using three-way ANOVA and the Tukey test. Fracture mode analysis was also done When the cavity had high C-factor, good bond quality and large volume, the bond strength decreased significantly The volume of resin composite restricted within the well-bonded cavity walls is also be suggested to be included in the concept of C-factor, as well as the cavity shape and bond quality. Since the bond quality and volume can exaggerate the effect of cavity shape on the shrinkage stress developed at the resin-dentin bond, resin composites must be filled in a method, which minimizes the volume that can increase the C-factor.

Comparison of shearbond strength between metal and indirect resin according to the different conditionings (표면처리에 따른 금속과 간접복합레진간의 전단결합강도 비교연구)

  • Choi, Su-Young;Choi, Hyunmin;Moon, Hong-Seok;Shim, June-Sung;Park, Young-Bum;Lee, Geun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.264-271
    • /
    • 2017
  • Purpose: The purpose of this study is to investigate the differences in bond strength of four different indirect composites to the gold alloy and Ni-Cr alloy according to type of metal surface treatment after water storage. Materials and methods: Type IV gold alloy and Ni-Cr alloy were used for casting alloy while four types of indirect composite resins (Gradia, Tescera Sinfony and in;joy) were used in this study. Metal specimens were produced by casting and total of 240 specimens (60 specimens per one indirect composite group) were prepared. After bonding indirect composite resin and undergoing 24 hours of polymerization, customized jig was attached to the metal specimen and shear bond strength were measured using universal testing machine. Also, differences in shear bond strength before and after water storage for 240 hours were also measured. Results: In the measurement of shear bond strength according to the metal surface treatments, bead group showed high strength followed by loop and flatting group (P<.05). After being stored in water bath for 240 hours, Gradia showed statistically significant high bond strength compared to other indirect composite resins in all groups (P<.05). Conclusion: Shearbond strength was found to be different according to type of metal surface treatment and type of metal used after storage in water. Further studies need to be developed for clinical practices as three are still problems of microleakage, stain or wear.

Improving the Wettability of Polymeric Surfaces and Surface Modification of Ceramic by Ion Beam in Reactive gases Environments (반응성 가스 분위기하에서 이온빔을 이용한 폴리머 표면의 친수성 증대 및 세라믹표 면개질)

  • 손용배
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.3 no.1
    • /
    • pp.11-24
    • /
    • 1996
  • 부분압이 다른 여러 가지 반응성 가스분위기하에서 이른곤 이온을 이용하여 PC, PET PMMA 그리고 PTFE 폴리머 표면의 삼차 증류수에대한 진수성을 증대하였다. 폴리머 표면의 친수성의 변화는 여러 가지 반응성 가스 분위기하에서 아르곤 이온의 조사량을 1014 부터 1x1017cm2까지 변화하면서 조사하였다. 접촉감은 아르곤 이온이 조사되는 폴리머 표면 근처에 유입된 가스의 방응성(O2>N2>H2)에 따라 많이 감소하였다, 폴리머 표면에 형성된 친수성기는 XPS Cls, Ols, 그리고 Nls 스펙트럼을 분석하여 확인하였다. 표면 개질된 PC와 PTFE에 대한 Al 금속의 접착력 증대를 Scotch tape와 인장실험을 통하여 확인하였다. 접착 력 증가는 표면 에너지 중 polar force의 증가에 의한 것으로 입증되었다. 에너지를 가진 아 르곤 입자 폴리머 체인 그리고 반응성 가스 사이의 반응기구는 2단계 모델로 설명가능하였 는데 그 기구는 첫 번째 이온의 조사에 의한 불안정한 폴리머 체인의 형성과 두 번째 단계 로 이렇게 형성된 폴리머 체인과 반응성 가스들 사이의 화학반응으로 이루어진다. 질화아루 미늄의 표면을 산소분위기하에서 아르곤 빔을 조사하여 표면개질한후 AlON층이 새롭게 형 성된 것을 XPS를 이용하여 확인할수 있었다. 개질된 질화알루미늄과 구리금속 박막간의 접 착력을 scratch 실험을 통하여 조사하였다.

진공 부품용 플라즈마 전해산화 피막 제조 및 특성 평가

  • Min, Gwan-Sik;Lee, Seung-Su;Yun, Ju-Yeong;Sin, Yong-Hyeon;Cha, Deok-Jun;Gang, Du-Hong;Seong, Gi-Hun;Kim, Seong-Cheol;O, Eun-Sun;Kim, Jin-Tae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.122.2-122.2
    • /
    • 2013
  • 플라즈마 전해산화(plasma electrolytic oxidation) 기술을 이용하여 제작한 산화 피막은 피막의 하층부(기지 금속과 접해 있는 부분)는 ${\alpha}$-phase의 산화물이 대부분을 이루고 있으며, 기지 금속과의 접착성도 뛰어나다. 하지만 피막의 표면이 거칠고, 다공성을 띄는 특징을 보인다. 본 연구에서는 피막의 거칠기와 다공성을 제어하기 위한 방법으로 전해액에 포함된 불순물(Si, P 등) 조성비의 변화에 초점을 맞췄으며, 불순물(Si, P 등)의 조성비를 변화시켜 가면서 실험을 진행하였다. 실험에는 60 Hz, 35 kW(700 V, 50 A)의 power supply가 사용되었다. 또한, 실험의 결과로 제작된 시편의 내전압(10 V/s), 내플라즈마(200 W, 10 min, Ar 5 sccm, 200 mTorr), 내화학성(HCl 36.46 wt%, 120 min) 테스트를 진행하였으며, 실험 결과를 바탕으로 ${\phi}300$ 대면적 시편의 제작도 완료하였다.

  • PDF

Effect of Adhesion layer on the Optical Scattering Properties of Plasmonic Au Nanodisc (접착층을 고려한 플라즈모닉 금 나노 디스크의 광산란 특성)

  • Kim, Jooyoung;Cho, Kyuman;Lee, Kyeong-Seok
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.7
    • /
    • pp.464-470
    • /
    • 2008
  • Metallic nanostructures have great potential for bio-chemical sensor applications due to the excitation of localized surface plasmon and its sensitive response to environmental change. Unlike the commonly explored absorption-based sensing, the optical scattering provides single particle detection scheme. For the localized surface plasmon resonance spectroscopy, the metallic nanostructures with controlled shape and size have been usually fabricated on adhesion-layer pre-coated transparent glass substrates. In this study, we calculated the optical scattering properties of plasmonic Au nanodisc using a discrete dipole approximation method and analyzed the effect of adhesion layer on them. Our result also indicates that there is a trade-off between the surface plasmon damping and the capability of supporting nanostructures in determining the optimal thickness of adhesion layer. Marginal thickness of Ti adhesion layer for supporting Au nanostructures fabricated on a silica glass substrate was experimentally analyzed by an adhesion strength test using a nano-indentation technique.

THE EXPRESSION OF OSTEONECTIN AND OSTEOCALCIN IN THE EXPERIMENTAL TOOTH MOVEMENT IN RAT (백서의 실험적 치아이동시 osteonectin 및 osteocalcin의 발현)

  • Bae, Sung-Real;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.699-716
    • /
    • 1998
  • This study was designed to evaluate the expression of non-collagenous protein in periodontal tissue during the experimental movement of rat incisors, by LSAB(labelled streptavidine biotin) immunohistochemical staining for osteonectin and osteocalcin. Twenty seven Sprague-Dawley rats were divided into a control group(3 rats) and 6 experimental groups(24 rats) where 75g of force was applied from helical springs across the maxillary incisors. Rats of experimental groups were sacrificed at 12 hours, 1, 4, 7, 14 and 28 days after force application, respectively. And the tissues of a control group and experimental groups were studied immunohistochemically and histologically. The results were as follows : 1. Until 28 days after force application, periodontal fibers had been strectched on tension side and compressed in pressure side of all the experimental groups, and the arrangement of periodontal fibers had not been recovered yet. 2. The expression of osteonectin in control group was rare in dentin, cementum and osteocyte, and was mild in odontoblasts and matrix of alveolar bone. 3. The expression of osteocalcin in control group was negative in gingiva, osteoblasts, osteocyte and cementum, and was rare in predentin, capillaries in pulp and periodontal ligament and the matrix of alveolar bone. 4. There was no difference in the expression of osteocalcin or osteonectin in dentin, cementum, pulp, odontoblasts, between of control and of experimental groups. 5. The expression of osteonectin in intermaxillary suture got the peak in 7-day and was declined after 14-day. The expression of osteocalcin remained in a same degree since it became mild in 14-day. 6. The expression of osteonectin in pressure side of periodontal ligament of experimental group was rare, which was similar to control group. But in tension side, it was increased until 14-day aftrer which it was declined. 7. The expression of osteocalcin in periodntal ligament was rare in 12-hour to 14-day, but became severe in 28-day, which was greater in tension side than in pressure side, and in the periodontal fiber next to alveolar bone than to tooth surface. 8. The expression of osteocalcin in alveolar bone was rare until 14-day in pressure side, but became moderate in 28-day. The expression of osteonectin was increased from 7-day by time dependency, which was greater in tension side than in pressure side.

  • PDF

Shear bond strength of Universal bonding systems to Ni-Cr alloy (니켈-크롬 합금에 대한 다용도 접착 시스템의 전단결합강도)

  • Song, So-Yeon;Son, Byung-Wha;Kim, Jong-Yeob;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the shear bond strength between Ni-Cr alloy and composite resin using universal adhesive systems coMPared to conventional method using metal primers. Materials and methods: For this study, a total of 120 cast commercial Ni-Cr alloy (Vera Bond 2V) disks were embedded in acrylic resin, and their surfaces were smoothed with silicon carbide papers and airborne-particle abrasion. Specimens of each metal were divided into 6 groups based on the combination of metal primers (Metal primer II, Alloy primer, Metal & Zirconia primer, MKZ primer) and universal adhesive systems (Single Bond Universal, All Bond Universal). All specimens were stored in distilled water at $37^{\circ}C$ for 24 hours. Shear bond strength testing was performed with a universal testing machine at a cross head speed of 1 m/min. Data (MPa) were analyzed using one-way ANOVA and the post hoc Tukey's multiple comparison test (${\alpha}$=.05). Results: There were significant differences between Single Bond Universal, All Bond Universal, Metal Primer II and Alloy Primer, MKZ Primer, Metal & Zirconia Primer (P<.001). Conclusion: Universal Adhesive system groups indicated high shear bond strength value bonded to Ni-Cr alloy than that of conventional system groups using primers except Metal Primer II. Within the limitations of this study, improvement of universal adhesive systems which can be applied to all types of restorations is recommended especially non-precious metal alloy. More research is needed to evaluate the effect of silane inclusion or exclusion in universal adhesive systems.

Effect of Adhesive Shear Strength of CFRP/Ni-Cr Alloy Under Severe Environmental Condition (가혹 환경이 복합재/Ni-Cr 합금 접착전단강도에 미치는 영향 연구)

  • Cho, Hyeon-Tae;Park, Seong-Min;Kim, Min-Jun;Hoang, Van-Tho;Kim, Hak-Inn;Son, Myung-Sook;Ahn, Jong-Kee;An, Ji-Min;Choi, Jin-Ho;Nam, Young-Woo;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.33 no.5
    • /
    • pp.275-281
    • /
    • 2020
  • The mechanical property related to lap shear strength of the joint structure between carbon fiber reinforced polymer (CFRP) composite and metal (Ni-Cr Alloy) under varying environmental conditions (temperature and humidity) was studied in order to apply to the aircraft fan blade. Room temperature dry (RTD), elevated temperature wet (ETW), and cold temperature dry (CTD) environmental conditions were chosen for investigation based on the flight conditions of aircraft. Lap shear strength tests were conducted according to ASTM Standard D3528 to evaluate the shear strength. The microstructure characteristic of failure zone was analyzed by SEM images to check the adhesive shear strength with the three environmental conditions. In comparison with shear strength for the RTD condition, the shear strength in the ETW condition was reduced by 72.8% while those for the CTD condition increased by 56.5%. The moisture absorption and high temperature in ETW condition strongly had an affect on mechanical property of adhesive, while cold temperature could enhance the adhesive shear strength due to the higher brittleness.

Clinical performance of esthetic ceramic partial-coverage restorations with supra-gingival margin using minimally invasive tooth preparation method according to the concept of adhesive dentistry (접착치의학 개념에 따른 최소 침습적 치아 삭제법을 적용한 심미적인 치은 연상 변연 도재 부분피개관 수복 증례)

  • Hong, Myung-Sik;Choi, Yu-Sung;Lee, Jong-Hyuk;Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.319-332
    • /
    • 2021
  • With the rapid development of aesthetic ceramic materials and resin adhesives, the transition from metal ceramic crown to all-ceramic restoration is being actively carried out. When making porcelain restorations, the advantages can be maximized only when appropriate forms and techniques are used. Recently, an esthetic partial-coverage restoration method with supra-gingival margins was introduced by applying a minimally invasive tooth removal method that preserves enamel as much as possible and enhances adhesion efficiency. Through this, various advantages such as minimization of tooth structure removal and ease of excess cement removal can be obtained. In addition, since this manufacturing method does not require cord packing, it is possible to save time for impression taking and reduce patient discomfort. Furthermore, the margins can be clearly obtained without the intervention of gingival fluid or blood, making it possible to manufacture more accurate restorations. In the following cases of patients with partial tooth defects, esthetic ceramic partial-coverage restorations with supra-gingival margin was applied using minimally invasive tooth preparation method according to the concept of adhesive dentistry. Therefore, unnecessary tooth abutment preparation was prevented and residual tooth structure could be preserved as much as possible. After delivery of the ceramic partial-coverage restorations, favorable outcome was obtained.