• Title/Summary/Keyword: 근접방사선치료

Search Result 168, Processing Time 0.022 seconds

Radiation Dose Calculation using MIRD TYPE PHANTOM in the Surrounding Organs during Brachytherapy of Breast Cancer (유방암의 근접치료 시 수학적 모의피폭체를 이용한 인접장기의 선량평가)

  • Park, Eun-tae;Kim, Jung-hoon;Im, In-chul
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.271-278
    • /
    • 2016
  • This study was fulfilled to evaluate the absorbed dose of breast and adjacent organs using MIRD type phantom in brachytherapy of breast cancer. The absorbed dose was analyzed assuming left or right breast is source organ which is $^{103}Pd$ or $^{192}Ir$. As a result, $^{192}Ir$ dose is higher than $^{103}Pd$ in source organ and also in contralateral breast. Particularly, significant adjacent organs are lung, liver, heart and contralateral breast in brachytherapy of breast cancer.

Evaluation of Fabricated Semiconductor Sensor for Verification of γ-ray Distribution in Brachytherapy (근접치료용 방사성 동위원소의 선량분포 확인을 위한 디지털 반도체 센서의 제작 및 평가)

  • Park, Jeong-Eun;Kim, Kyo-Tae;Choi, Won-Hoon;Lee, Ho;Cho, Sam-Joo;Ahn, So-Hyun;Kim, Jin-Young;Song, Yong-Keun;Kim, Keum-bae;Huh, Hyun-Do;Park, Sung-Kwang
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.280-285
    • /
    • 2015
  • In radiation therapy fields, a brachytherapy is a treatment that kills lesion of cells by inserting a radioisotope that keeps emitting radiation into the body. We currently verify the consistency of radiation treatment plan and dose distribution through film/screen system (F/S system), provide therapy after checking dose. When we check dose distribution, F/S systems have radiation signal distortion because there is low resolution by penumbra depending on the condition of film developed. In this study, We fabricated a $HgI_2$ Semiconductor radiation sensor for base study in order that we verify the real dose distribution weather it's same as plans or not in brachytherapy. Also, we attempt to evaluate the feasibility of QA system by utilizing and evaluating the sensor to brachytherapy source. As shown in the result of detected signal with various source-to-detector distance (SDD), we quantitatively verified the real range of treatment which is also equivalent to treatment plans because only the low signal estimated as scatters was measured beyond the range of treatment. And the result of experiment that we access reproducibility on the same condition of ${\gamma}$-ray, we have made sure that the CV (coefficient of variation) is within 1.5 percent so we consider that the $HgI_2$ sensor is available at QA of brachytherapy based on the result.

Endobronchial Brachytherapy for Malignant Airway Obstruction: Low Dose Rate Versus High Dose Rate (악성 종양에 의한 기도폐쇄시 내기관지 근접치료 : 저선량 치료 대 고선량 치료의 비교)

  • Cho, Young-Kap
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.123-128
    • /
    • 1996
  • Purpose : This is a retrospective study to compare the Palliation rates, survival rates and complications of low dose rate and high dose rate endobronchial brachytherapy in the management of malignant airway obstruction. Materials and methods : Forty three consecutive patients with malignant airway compromise from primary or metastatic lung tumors were treated with low dose rate(LDR) endobronchial Iridium-192 insertion(21 patients) between October 1988 and June 1992, and high dose rate(HDR) endobronchial brachytherapy(22 patients) between August 1992 and April 1994 with palliative aim Flexible fiberoptic bronchoscopy under fluoroscopic control was utilized in all 91 procedures. Twenty seven LDR Procedures delivered a dose of 5-7.5 Gy to a 1.0 cm radius respectively. Results : Subjective and objective responses to treatments were evaluated on follow-up examinations by clinical examination, chest x-rays and CT scan of the chest on some patients. Fifteen of 21 LDR patients and 19 of 22 HDR Patients showed subjective improvement in terms of better breathing and less Productive cough as well as complete disappearance of hemoptysis. Objective improvement on chest x-rays and CT scan of the chest had been demonstrated on 8 LDR Patients and 10 HDR patients. Conclusion : The technique of LDR and HDR endobronchial brachytherapy is simple and well tolerated procedure with minimal morbidity It Provides excellent palliation by keeping airway Patent in these short life-spanned patients.

  • PDF

The Role of Radiotherapy in the Treatment of Extrahepatic Bile Duct Carcinoma (간외담도종양에서 방사선치료의 역할)

  • Shin Hyun Soo;Kim Gwi Eon;Lee Hyung Sik;Suh Chang Ok;Loh John JK;Lee Jong Tae
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.253-263
    • /
    • 1991
  • Twenty-seven patients with unresectable extrahepatic bile duct carcinoma (n=21) or with microscopic evidence of tumor rest after aggressive surgery for extrahepatic bile duct carcinoma (n=6) between 1985 and 1990 were given radiotherapy consisting intentionally external radiotherapy and/or intraluminal therapy using Gamma-Med 12i (192-Ir) high dose rate (HDR) remote control afterloading system following bile drainage procedures and Gianturco stent insertion. The objectives of this study has been to assess the feasibility and effects on survival of a combination of external radiotherapy and brachytherapy with which we hope to achieve optimal loco-regional control for patients with unresectable extrahepatic bile duct tumors. Sixteen patients were men and eleven were women, and the mean age was 58 years (34-70). 10MV X-ray was used for radiation therapy, with the total dose ranging from 45 Gy to 55 Gy, and intraluminal brachytherapy performed after external radiotherapy, with the dose of total 15 Gy. The minimum follow up was 12 months. Failure were predominantly local-regional, without distant failure. Median survival was 10 months; 2-year actuarial survival rates was $21\%$. Median survival for common hepatic duct (CHD) cancer was 9 months; for common bile duct (CBD) cancer, was 16 months. And median survival for incomplete surgery/external radiotherapy group and external/intraluminal radiotherapy group was 10 months; for external radiotherapy alone group, was 6 months. Use of chemotherapy and/or hyperthermia were not affected in survival. Therefore, our result is that the survival rates in the group of external/intraluminal radiotherapy were comparable with ones in the group of incomplete resection/external radiotherapy, and so we believe that the aggressive local and regional radiotherapy can improve the quality of life and the survival length.

  • PDF

Remote Afterloading Hish Dose Rate (HDR) Endobronchia1 Brachytherapy (원격조정 고선량 기관지내 근접 치료)

  • Chang Hyesook;Choi Eun Kyung;Yi Byong Yong;Kim Won Dong;Kim Woo Sung;Koh Youn Suck
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.227-232
    • /
    • 1991
  • Authors described the remote afterloading endobronchial brachytherapy (EBBT technique using the microSelectron HDR Ir-192 and the Asan Medical Center experience. Total 28 EBBT in 9 patients were performed since November 1989 and 24 EBBT in 8 patients were emploiyed for palliation and 3 EBBT in 1 patient was treated curatively. Authors observed a significant relief of obstructive symptom with tumor regression in 7 patients out of 8 who were treated palliatively but one of them died of pulmonary congestion in 3 weeks after EBBT One patient with prior therapy of extensive electrocautery expired within 1 day after 2nd EBBT procedure with massive hemorrhage from the lesion. EBBT procedure has been tolerable and can be performed as an outpatient.

  • PDF

A study of Brachytherapy for Intraocular Tumor (안구내 악성종양에 대한 저준위 방사선요법에 관한 연구)

  • Ji, Gwang-Su;Yu, Dae-Heon;Lee, Seong-Gu;Kim, Jae-Hyu;Ji, Yeong-Hun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.19-27
    • /
    • 1996
  • I. Project Title A Study of Brachytherapy for intraocular tumor II. Objective and Importance of the project The eye enucleation or external-beam radiation therapy that has been commonly used for the treatment of intraocular tumor have demerits of visual loss and in deficiency of effective tumor dose. Recently, brachytherapy using the plaques containing radioisotope-now treatment method that decrease the demerits of the above mentioned treatment methods and increase the treatment effect-is introduced and performed in the countries, Our purpose of this research is to design suitable shape of plaque for the ophthalmic brachytherapy, and to measure absorbed doses of Ir-192 ophthalmic plaque and thereby calculate the exact radiation dose of tumor and it's adjacent normal tissue. III. Scope and Contents of the project In order to brachytherapy for intraocular tumor, 1. to determine the eye model and selected suitable radioisotope 2. to design the suitable shape of plaque 3. to measure transmission factor and dose distribution for custom made plaques 4. to compare with the these data and results of computer dose calculation models IV. Results and Proposal for Applications The result were as followed. 1. Eye model was determined as a 25mm diameter sphere, Ir-192 was considered the most appropriate as radioisotope for brachytherapy, because of the size, half, energy and availability. 2. Considering the biological response with human tissue and protection of exposed dose, we made the plaques with gold, of which size were 15mm, 17mm and 20mm in diameter, and 1.5mm in thickness. 3. Transmission factor of plaques are all 0.71 with TLD and film dosimetry at the surface of plaques and 0.45, 0.49 at 1.5mm distance of surface, respectively. 4. As compared the measured data for the plaque with Ir-192 seeds to results of computer dose calculation model by Gary Luxton et al. and CAP-PLAN (Radiation Treatment Planning System), absorbed doses are within ${\pm}10\%$ and distance deviations are within 0.4mm Maximum error is $-11.3\%$ and 0.8mm, respectively. As a result of it, we can treat the intraocular tumor more effectively by using custom made gold plaque and Ir-192 seeds.

  • PDF

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

고 선량율 근접 및 온열치료 병용 삽입관의 제작과 특성

  • 추성실;김성규
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.52-52
    • /
    • 2003
  • 악성종양을 치료하는 방법중 방사선과 온열요법은 가장 강력한 치료방법으로 연구되어왔으며 이를 병용함으로 서 상승효과를 얻을 수 있다. 인체조직에 41$^{\circ}C$ 이상의 열을 가하면 세포질의 단백질변성으로 세포에 손상을 주어 세포가 사멸하게 되며 세포의 생존율은 가열시간 즉 열량에 따라 지수적으로 감소한다. 온열은 세포주기중 방사선 저항성이 매우 큰 DNA 합성시기와 산도가 높을 때 감수성이 매우 크기 때문에 방사선과 병용요법은 상호 상승효과를 가져온다. 이와 같이 온열을 이용한 악성종양의 치료가능성은 생물학적 기초연구와 임상시험에서 경이적인 효과를 얻을 수 있었으나 아직 까지 가열방법과 온도분포측정이 큰 과제로 남아있으며 주위건강조직의 가열을 피하면서 인체 깊은 곳에 존재하는 종양에만 집중 가열하는 방법인 삽입형 온열치료방법에 대한 연구가 집중되었다. 한편 방사선 치료방법은 주위 건강조직의 피폭을 최소로 줄이고 종양에만 집중 조사가 요구되며 자궁암, 유방암, 뇌암등 부피가 작고 집중적 치료를 요하는 종양은 방사성동위원소를 이용한 근접 삽입치료 (Brachyradiotherapy)가 큰 효과를 나타내고 있다 방사선과 온열의 병행 치료를 위하여 방사선 삽입 치료에 사용한 선원 삽입관을 그대로 두고 삽입관 속에 방사성 동위원소 대신 온열 전극을 넣어 열을 가하는 방사선 온열 병용치료방법을 고안하였으며 방사선과 온열병용에 사용할 최적 삽입관의 제작과 이에 따른 온도분포의 측정과 최적삽입방법을 결정하였다. 방사선 삽입치료용 폴리에찌렌 삽입관의 외부에 금박을 입혀 라디오파 첨극을 삽입할 때 서로 연결되도록 고안 제작함으로서 방사선 삽입치료와 자입식 온열치료를 동시에 만족하게 수행할 수 있는 병용삽입관 (Flexible thermoradiotherapy probes)을 제작하였다. 전도율이 큰 금박부위가 직접 조직에 접촉됨으로 라디오파의 전달이 용이하며 금박의 길이를 2 cm 에서 5 cm 로 구분제작 함으로서 종양의 크기와 모양에 따라 선택할 수 있도록 하였다. 라디오파를 이용한 온열분포의 측정은 인체조직과 전기적 특성이 비슷한 물질인 한천 팬텀 제작하여 사용하였으며 온도분포 측정은 열전대와 서머그람으로 시행하였다. 생체조직 내에서의 온도분포와 온열효과를 관찰하기 위하여 직접 개의 뇌를 이용하여 시행하였으며 4 개의 전극을 이용하여 43$^{\circ}C$로 50분간 가열하고 일주일후 개를 회생시켜 개 뇌에 대한 조직학적 검사를 시행하였다. 한편 팬텀 표면에서 중앙부로 안테나 길이가 2 cm 인 4 개의 전극을 1 cm 간격으로 정사각형이 되도록 삽입하여 가열하였을 때 90% 등온곡선이 반경 1.25의 원형으로 균일하게 분포되었고 종단면상 삽입관의 길이에 따라 균일한 온도분포가 이루어졌다. 전극을 2 cm 간격으로 삽일 하였을 때 90% 등온곡선이 1.75 반경으로 거의 4 각형의 균일한 분포를 얻었으나 전극의 간격이 증가하면 전도율이 떨어져서 전극 중심부에 불균일한 온도분포를 형성하였다. 동물실험에서 정상 개의 뇌 실질에 자입하여 직접 정방형의 중심을 43$^{\circ}C$로 유지하며 50분간 온열 요법을 시행한 후 관찰한 조직병리학적 소견은 liquefactive necrosis, pyknosis of neuronal element 및 polymorphonuclear leukocytes들의 회백질에서 급성기에 관찰되었고 liquefactive necrosis 주위에 lipid-laden macrophage들이 관찰됨이 공통적인 특정이었으며 후기변화로 괴사조직 주위로 신경교세포의 증식이 관찰되었다.

  • PDF

Real Time On-line Quality Assurance System for HDR Brachytherapy (고선량률 근접 방사선 치료를 위한 실시간 온-라인 정도 관리(QA) 시스템 개발)

  • Lee Su Jin;Lee Re Na;Yi Byang Yang;Lim Sang Waak;Choi Jin Ho
    • Progress in Medical Physics
    • /
    • v.15 no.3
    • /
    • pp.156-160
    • /
    • 2004
  • An essential quality assurance (QA) procedure in high dose rate (HDR) remote after-loading brachytherapy is that of the verification of the Ir-192 HDR source positioning accuracy. A number of methods using mechanical rulers or autoradiograph and video cameras have been reported to check the positional error of the Ir-192 source. In this study, the feasibility of a CMOS (Complementary Metal Oxide Semiconductor) PC camera, with a fluorescent screen, was investigated. The agreement between the planned and measured dwell position was better than 1 mm and dwell times better than 0.4 sec. Our results indicate that the CMOS PC camera system could be used as a QA tool for the on-line determination of the source position and dwell time.

  • PDF