• Title/Summary/Keyword: 근관 만곡

Search Result 58, Processing Time 0.024 seconds

A Comparison of the Effectiveness of Stainless-Steel Hand Instrument and Rotary NiTi Retreatment Instrument to Remove Gutta-Percha in Curved Root Canals (만곡된 근관에서 Gutta-Percha 제거 시 스테인리스스틸 수기구와 회전식 NiTi 재치료용 기구의 효과 비교)

  • Nam, Dong-Goo;Kim, Min-Jeong;Cho, Hye-Jin;Lee, Kwang-Won;Yu, Mi-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.99-107
    • /
    • 2011
  • The main objective of nonsurgical retreatment is to disinfect the root canal space for periradicular healing. Thus, efficient removal of the filling material from the root canal system is essential to ensure a favorable outcome. Traditionally, the removal of root canal filling material was performed by stainless steel hand instrument and this procedure is time and effort-consuming. Recently, rotary NiTi retreatment instruments are developed to effective removal of root canal filling material. The aim of this study was to evaluate the effectiveness of stainless-steel hand instrument and rotary NiTi retreatment instrument when removing gutta-percha in curved root canals. For the remaining materials, there were no significant differences between groups. But the rotary NiTi system proved to be faster than hand instruments in removing root filling materials.

A STUDY OF INSERTION DEPTH OF BUCHANAN PLUGGER AFTER SHAPING USING NI-TI ROTARY FILES IN SIMULATED RESIN ROOT CANALS (Simulated resin root canal에서 엔진 구동형 Ni-Ti 파일로 근관성형 후 Buchanan plugger의 근관 내 삽입깊이에 대한 비교 연구)

  • Park, Youn-Sik;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.125-132
    • /
    • 2006
  • This study was conducted to evaluate the insertion depth of Buchanan plugger after shaping by various Ni-Ti rotary files. It was conducted to determine which size of plugger are appropriate, when root canals are shaped with Ni-Ti rotary files and obturated by Continuous wave of condensation technique. Two type of eighty simulated resin blocks were used : J-shaped and straight shaped canal. The simulated canals were instrumented by ProTaper and ProFile. Buchanan pluggers were inserted into the canal, and then the image was recorded to scanner. The distance from the apex of the canal to the plugger tip was measured by image analysis program. Data were analyzed by one-way ANOVA followed by Scheffe's test. The results were as follows 1. In straight canal finished up to ProTaper F2 and F3 file, F and FM pluggers were inserted more than 5 mm short of working length. 2. In J-shaped canal finished up to ProTaper F2 file, F pluggers were inserted more than 5 mm short of working length. Finished up to ProTaper F3 file. F and FM pluggers were inserted more than 5 mm short of working length. 3. In straight and J-shaped canal finished up to ProFile .06/#20 and .06/#25, any of Buchanan plugger could not be inserted more than 5 mm short of working length. These results suggest that canals shaped by ProTaper could be obturated by Continuous wave of condensation technique with F and FM size Buchanan plugger.

EFFECTS OF ANTICURVATURE FILING ON DANGER ZONE WIDTH IN CURVED ROOT CANALS (만곡된 근관 성형시 스테인레스 강 파일과 니켈 티타늄 파일의 anticurvature filing 영향)

  • Kim, Eui-Seong;Kim, Hyun-Jung;Seo, Deog-Gyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.232-239
    • /
    • 2009
  • The aim of this study was to compare the effects of anti curvature filing with stainless steel k-file versus nickel-titanium ProFile in the shaping of mesial root canals of extracted mandibular molars. A total of 60 canals from 30 mesial roots of mandibular molar teeth were randomly assigned to three groups with n=20 each. They were prepared with different instruments and methods: The first group with stainless steel k-file and circumferential filing. the second with precurved stainless steel k-file and anticurvature filing and the third with ProFile C06 taper) and anticurvature filing. Using a micro-computed tomography system (skyscan-1076, SKYSCAN, Antwerpen, Belgium), pre-and post-operative specimens were scanned. Subsequently, canal images were superimposed and changes in root dentin thickness were measured at distal side (danger zone) of the canal. The data was analyzed using a one-way ANOVA and the comparison of means was conducted using a post hoc multiple comparison Tukey test. There were significant differences in the change of root dentin thickness at the $7.5{\sim}8.5\;mm$ level between group 1 and 2, $3.5{\sim}6mm$ level between group 1 and 3 and $3.5{\sim}6mm$ level between group 2 and 3(n=20, P<0.05).

EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION (ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향)

  • Seo, Min-Chul;Jeon, Yoon-Jeong;Kang, In-Chol;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • This study was conducted to evaluate canal configuration after shaping by $ProTaper^{TM}$ with various rotational speed in J-shaped simulated resin canals. Forty simulated root canals were divided into 4 groups, and instrumented using by $ProTaper^{TM}$ at the rotational speed of 250, 300, 350 and 400 rpm. Pre-instrumented and post-instrumented images were taken by a scanner and those were superimposed. Outer canal width, inner canal width, total canal width, and amount of transportation from original axis were measured at 1, 2, 3, 4, 5, 6, 7 and 8 mm from apex. Instrumentation time, instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA followed by Scheffe's test. The results were as follows 1. Regardless of rotational speed, at the $1{\sim}2mm$ from the apex, axis of canal was transported to outer side of a curvature, and at 3~6 mm from the apex, to inner side of a curvature. Amounts of transportation from original axis were not sienifcantly different among experimental groups except at 5 and 6 mm from the apex. 2. Instrumentation time of 350 and 400 rpm was significantly less than that of 250 and 300 rpm (p<0.01). In conclusion the rotational speed of $ProTaper^{TM}$ files in the range of $250{\sim}400rpm$ does not affect the change of canal configuration, and high rotational speed reduces the instrumentation time. However appearance of separation and distortion of Ni-Ti rotary files can occur in high rotational speed.

Comparison of shaping ability using various Nickel-Titanium rotary files and hybrid technique (다양한 전동 니켈 티타늄 파일과 혼합사용법에 의한 근관 성형 효율 비교)

  • Kim, Jung-Won;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.530-541
    • /
    • 2007
  • Currently, various Nickel-Titanium rotary files are used in endodontic treatment, but there is no one perfect system that can be applied to any clinical situation. Therefore, the combined uses of various file systems which can emphasize the advantages of each system are introduced as hybrid instrumentation. The ProTaper system is efficient in body shaping and apical pre-enlargement but is reported to have more possibility of transportation and produce more aberrations and deformation in more or less severe curved canals. Recently, new ProTaper system(ProTaper Universal) with different configuration and cross-sectional design to overcome the week points of ProTaper have been marketed. The purpose of this study was to compare and evaluate the shaping abilities of ProTaper, ProTaper Universal system, and two hybrid methods using S-series of ProTaper Universal and Hero Shaper or ProFile. The time lapses for instrumentation were measured and the used files were inspected for distortion. The pre- and post-instrumented root canals were scanned and superimposed to evaluate the aberrations and reduction of root canal curvature and change of radius of canal curvature. The increased canal width and apical centering ratio were calculated at 1, 2, 3, 4 and 5 mm levels from apical foramen. Under the conditions of this study, the ProTaper Universal seems to have better shaping ability than ProTaper in terms of instrumented width and instrumentation time. It may be suggested that the ProTaper Universal system is efficient as much as hybrid instrumentation using ProTaper and other constant-tapered NiTi file systems in highly experienced operators.

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

STRESS DISTRIBUTION FOR NITI FILES OF TRIANGULAR BASED AND RECTANGULAR BASED CROSS-SECTIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS (만곡 근관에서 삼각 혹은 장방형 단면 구조의 니켈-티타늄 파일 응력 분포에 관한 3차원 유한요소 연구)

  • Kim, Hyun-Ju;Lee, Chan-Joo;Kim, Byung-Min;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • The purpose of this study was to compare the stress distributions of NiTi rotary instruments based on their cross-sectional geometries of triangular shape-based cross-sectional design, S-shaped cross-sectional design and modified rectangular shape-based one using 3D FE models. NiTi rotary files of S-shaped and modified rectangular design of cross-section such as Mtwo or NRT showed larger stress change while file rotation during simulated shaping. The stress of files with rectangular cross-section design such as Mtwo, NRT was distributed as an intermittent pattern along the long axis of file. On the other hand, the stress of files with triangular cross-section design was distributed continuously. When the residual stresses which could increase the risk of file fatigue fracture were analyzed after their withdrawal. the NRT and Mtwo model also presented higher residual stresses. From this result, it can be inferred that S-shaped and modified rectangular shape-based files were more susceptible to file fracture than the files having triangular shape-based one.

Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file (GT Rotary Ni-Ti file과 함께 사용한 구동용 Ni-Ti file의 근관 성형력 비교에 대한 연구)

  • Shin, Dong-Ryul;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.196-206
    • /
    • 2002
  • 본 연구는 근관의 치관부는 GT Rotary file을 이용하여 성형하고, 근단부는 K-Flexofile, ProFile .04, Lightspeed, HERO642 file로 성형하여 근관용 file의 근관성형력을 비교하는 것이다. 실험 표본으로는 resin simulated root canal blocks(Dentsply, Swiss)를 이용하였고 4개의 군으로 분류하여 실험을 실시하였다. 모든 resin block을 GT Rotary file(Dentsply, Swiss)을 이용하여 치관부를 형성한 후 근단부는 K-Flexofile(Dentsply, Swiss), ProFile .04 taper file(Denstply. Swiss), Lightspeed file(Lightspeed Tech., USA), HERO642 file(Micromega, France)로 ISO size #35까지 형성하였다. 성형 후 preparation time과 instrument failure를 측정하였고 최종 사용한 file을 resin block 내에 재위치시켜 working length의 변화량을 0.5mm 단위로 측정하였다. Resin debris에 의한 canal blockage를 조사하였으며, 근관 내의 인상을 채득하여 canal form을 평가하였다. 성형 전과 성형 후의 사진을 촬영하고 computer software를 이용하여 중첩시킨 후 canal aberration, canal transportation을 평가하여 다음과 같은 결과를 얻었다. 1. Preparation time, working length의 변화량, canal blockage, canal aberration, canal transportation에 있어서 Ni-Ti file이 stainless steel file에 비하여 우수하였다(p<0.05). 반면에 근관성형력에 있어서 canal form과 canal transportation을 제외하고는 세 Ni-Ti file 사이에는 유의차가 없었다(p>0.05). 2. Canal form 중 taper에 있어서 Lightspeed는 적절하지 못한 taper를 보여주었다(p<0.05). 3. Canal transportation에 있어서 Lightspeed 군과 HER0642 군이 K-Flexofile 군과 ProFile .04 군에 비해 적게 나타났고(p<0.05), 특히 만곡의 끝 부분에서는 Lightspeed 군이 가장 적게 나타났다(p<0.05). 이상과 같은 연구결과로 보아 부적절한 taper를 지니고 있던 Lightspeed fie과 HERO642 file 중 HERO642 file은 GT Rotary file과 함께 사용함으로써 적절한 taper로 형성할 수 있었으나 Lightspeed file은 효과적이지 못하였으므로 적절한 taper를 형성하기 위한 file이 치근의 중간부를 형성하기 위해 필요함이 확인되었다.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

Comparison of apical transportation and change of working length in K3, NRT AND PROFILE rotary instruments using transparent resin block (Transparent resin block을 이용한 K3, NRT, PROFILE의 apical transportation 및 working length 변화양상의 비교)

  • Yoon, Min-Jung;Song, Min-Ju;Shin, Su-Jung;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.59-65
    • /
    • 2011
  • Objectives: The purpose of this study is to compare the apical transportation and working length change in curved root canals created in resin blocks, using 3 geometrically different types of Ni-Ti files, K3, NRT, and Profile. Materials and Methods: The curvature of 30 resin blocks was measured by Schneider technique and each groups of Ni-Ti files were allocated with 10 resin blocks at random. The canals were shaped with Ni-Ti files by Crown-down technique. It was analyzed by Double radiograph superimposition method (Backman CA 1992), and for the accuracy and consistency, specially designed jig, digital X-ray, and CAD/CAM software for measurement of apical transportation were used. The amount of apical transportation was measured at 0, 1, 3, 5 mm from 'apical foramen - 0.5 mm' area, and the alteration of the working length before and after canal shaping was also measured. For statistics, Kruskal-Wallis One Way Analysis was used. Results: There was no significant difference between the groups in the amount of working length change and apical transportation at 0, 1, and 3 mm area (p = 0.027), however, the amount of apical transportation at 5 mm area showed significant difference between K3 and Profile system (p = 0.924). Conclusions: As a result of this study, the 3 geometrically different Ni-Ti files showed no significant difference in apical transportation and working length change and maintained the original root canal shape.