그린 리모델링을 위한, 적정 외피시스템 선정에 관한 연구 (Selection of the Optimal Building Skin-System in Remodeling Projects)

  • 신영수;조규만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.296-297
    • /
    • 2014
  • United Nations Framework Convention on Climate Change(UNFCCC), an international treaty to prevent the regulation and global warming, has passed through the General Assembly for 17 times from 1992 to 2011. To create a performance plan specific, such as the Kyoto Protocol, it is to promote the reduction of energy consumption and greenhouse gases worldwide. In South Korea, Korea Infrastructure Safety and Technology Corporation(KISTEC) is working and supporting for developing method of green remodeling policy. Among several solutions, "Remodeling" ensures to increase the energy efficiency of buildings and to reduce the emissions of greenhouse gases, and consequently it could maintain buildings high efficiency. For remodeling projects, it is most important to determine construction plan including remodeling scopes and methods, while the plan has been determined by the engineer's background and experience. Therefore, this study aims at developing a method for selecting optimal skin system which has remarkable influence to energy performance of the buildings.

  • PDF

지역별 단독주택 에너지 절감 리모델링 전략 민감도 분석 (Sensitivity Analysis of Energy Efficient Refurbishment Strategies for Detached Houses in Three Climate Zones)

  • 이병연
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.518-527
    • /
    • 2020
  • 그린 리모델링 전략 수립이 기술 중심적으로 진행되어 현장 상황을 반영한 맞춤형 전략 수립의 필요성이 제기된다. 본 논문은 리모델링 활성화를 위하여 현장에 적합한 리모델링 전략수립 방법론으로 민감도 분석을 통한 기술전략 평가와 활용가능성 분석을 목적으로 한다. 30평형 규모 단독주택을 대상으로 에너지플러스엔진과 모드프론티어 최적화 기법을 통합하여 활용하여 서울, 대전, 부산지역에 1980년대 이전, 1984년, 2010년 준공기준을 적용한 총 9개 모델 대상 최적화 후 민감도 분석을 통한 리모델링 전략 우선순위를 도출하였다. 1980년 이전 모델의 경우 지붕 단열성능 강화 전략이 민감도 상위 순위를 갖는 것으로 나타났다. 창호 총일사취득율 기준은 전 지역, 전 준공 시기를 막론하고 다음 상위 민감도를 갖으며, 이는 열관류율 중심 기준에서 총일사취득율 기준을 포함하는 성능 기준으로 확대될 필요가 있음을 보여준다. 대규모 철거공사를 수반하는 창면적비의 조정은 민감도가 낮아 형상 유지 리모델링의 효용을 확인하였다. 사례별 상이한 민감도 결과는 리모델링 전략 수립에서 민감도 분석을 경제성, 시공성 등의 기준 등과 함께 종합적인 리모델링 전략 수립의 가능성을 제시한다.

법령과고시 (1) - 에너지 소비절감을 위한 녹색건축물 조성지원법 개정

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • 통권288호
    • /
    • pp.81-82
    • /
    • 2014
  • 국토교통부(장관 서승환)는 그린리모델링 사업지원 및 효율적 건물 에너지 관리 방안 등을 담은 '녹색건축물 조성지원법'을 일부 개정해 지난 5월 28일 공포했다. 이로써 정부는 녹색건축물 시공 전문기업을 지원할 뿐만 아니라, 에너지 절약적이고 친환경적인 건축물의 보급 활성화를 위하여 일정규모 이상의 건축물을 건축하는 경우에는 녹색건축 에너지효율등급 인증을 받도록 하고, 건축물 에너지 소비 절감을 위한 고효율 냉 난방 장치 설치를 의무화했다.

  • PDF

그린 프레임의 기둥접합부 특성 분석 (Comparative Analysis of Column Connection Characteristics of Green Frame)

  • 김근호;이택운;이성호;김선국
    • 한국건축시공학회지
    • /
    • 제12권4호
    • /
    • pp.415-425
    • /
    • 2012
  • 공동주택의 리모델링 수월성, 장수명화, 자원저감, 친환경 구조시스템 구현을 위하여 라멘구조인 그린프레임 공법이 개발되었다 그린프레임의 주요 구조부재인 합성 프리캐스트 콘크리트 기둥과 보는 접합부 철골과 콘크리트에 의한 접합으로 신속하고 정밀하게 설치할 수 있다. 그린프레임의 접합부는 그 형상에 따라 네 종류로 분류할 수 있으며, 각 종류에 따라 각기 접합 특성과 시공방법이 다르다. 현장상황에 적합한 기둥을 선택하기 위해서는 기둥 종류별 접합부 특성 비교 연구가 필요하다. 따라서 본 연구에서는 기둥 종류별 접합부의 공기, 원가, 품질, 안전성능 비교 분석하는 것을 목적으로 한다. 본 연구의 결과는 GF 공법의 설계단계에서 프로젝트 특성을 반영한 적정 합성 프리캐스트 콘크리트 기둥을 선정하는데 활용된다.

학교시설의 그린리모델링을 위한 디자인지표 개발 및 사용자참여설계 활용에 관한 연구 (A Study on the Development of Design Indicator and User Participation Design for Green Remodeling of School Facilitiess)

  • 김은희;류수훈
    • 교육시설 논문지
    • /
    • 제24권3호
    • /
    • pp.3-13
    • /
    • 2017
  • This study has developed a design indicator required to promote green remodeling in school facilities. And, implemented the green remodeling pilot test on the school facilities that are planning actual remodeling. This pilot test suggested user participation design methodology such as verification of the developed design indicator, design goal setting, evaluation and adjustment of design proposal. The Green Remodeling Design Indicators were classified into 3 large categories of architectural performance, usability, and design through analysis of cases related to 'green buildings' and 'remodeling'. We have developed nine middle categories such as architectural and structural performance, facility performance, environmentally-friendly, circulation, space, amenity, harmony with surroundings, form and symbolization. In addition, 42 detailed indicators were developed for each category, including general, functional, and special indicators. For the verification of this study, two green remodeling design workshops were conducted for Gwangju J elementary school. The first design workshop presented the importance of the design indicator and set the goal of the design plan of green remodeling for project. And, the second Workshop presented the evaluation of the satisfaction with the design and the direction of future adjustment for project. The design indicator developed in this study can be utilized as a design indicator of design quality management and decision system for the school green remodeling in the future. In addition, by accumulating information on the Green Remodeling Project, it is necessary to spread green remodeling and construct a sustainable building environment.

그린리모델링 기숙사의 물리적환경 변화와 거주자평가 (Physical Environment Change and Occupancy Evaluation on Green-Remodeled University Dormitory)

  • 최윤정;이호연;이현정;김원배
    • 한국주거학회논문집
    • /
    • 제28권1호
    • /
    • pp.37-44
    • /
    • 2017
  • This study focuses on the university dormitory remodeled toward energy efficiency. The study has its purpose on deriving the aspects to be concerned for later green remodeling and enhancing the effects of green remodeling, by analyzing the changes of physical environment, changes of energy consumption amount, and needs of the residents. For this purpose, the study went through the review of project report from government office for green remodeling, field investigation of remodeling elements, and the occupancy evaluation by Focus Group Interview. FGI means interviewing small group of the residents who lived in the subjected dormitories both before and after the remodeling. As results, the elements of green remodeling in targeted dormitories were inner wall insulation, top-floor ceiling insulation, replacement of windows, installment of automatic entrance door and making transfer space connected the entrance door. As the parts of equipment system, EHP high-efficiency cooler, highly efficient radiator, upgraded LED lightings with covers, and automatic control system (only one building) were installed. Energy consumption was declined, and the satisfaction of residents was increased after the green remodeling. However, the aspects which were not improved or unsatisfying also have been detected. Therefore, the study states the suggestions each for the administrators, designers and planners, and residents to concern for enhancing the effects of green remodeling or construction of new dormitories.

공동주택의 그린 리모델링을 위한 외피시스템 환경영향 DB 구축에 관한 연구 (A Study on the Establish Environmental Impact of Database of the Envelope System for Green Remodeling of Apartment Housing)

  • 이종건;태성호;채창우;김낙현
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.73-79
    • /
    • 2016
  • Purpose: In order to improve the energy performance of existing buildings, so actively promoted green remodeling business. Also, improvement of the performance of envelope system of apartment housing is an absolute. The purpose of implementation of the data base and application plan of the envelope system for green remodeling of apartment housing. Method: For this study, It proposed a classification system of green remodeling envelope system constructed actual to select the applicable representative method and input material of apartment housing for green remodeling. In this study, divided into construction waste processing stage and production phase of the material for the boundary of the system, and implementation the classification system of the envelope system for applicable green remodeling. For this, established 6 environmental impact categories database. Result: As a result of various suggestions were available for case study research, alternative combinations of existing combinations than six kinds of environmental impact insulation system with superior input materials combining 96 kinds, window system, 12 kinds for determining the applicability of the established database. Depending on the account for a large proportion if compared to the detailed analysis of the environmental impact resulting from the production phase and disposal phase was analyzed that the operating management of the necessary input materials. Is considered that the economic performance and integrated energy performance required by the applicable public housing green remodeling evaluation techniques considered for future improvements insulation sheath.

그린리모델링 건축물을 위한 녹색건축인증기준 개선방향에 대한 기초 연구 (A Fundamental Study on the Revision Direction of G-SEED for Green Remodeling Building)

  • 현은미;안광호;김용식
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.51-58
    • /
    • 2017
  • Purpose: G-SEED's evaluation of existing buildings in Korea is an important point because the energy consumption and CO2 emissions of existing buildings are continuously increasing due to the aging of buildings over time. In 2016, the government has set up a 'Green Remodeling Certification Standard' in G-SEED in order to revitalize the green remodeling business of existing buildings. As a result, G-SEED is distinguished between buildings with green remodeling and buildings with general remodeling. Therefore, this study analyzed the system of the certification of the green remodeling building which is aimed at improving the performance of the building. Method: First, we analyze characteristics of the existing building certification standards of G-SEED(Korea), LEED(USA), and BREEAM(UK). Second, the evaluation criteria are based on the G-SEED Green Remodeling Certification, 2016, LEED for BD + C: New construction and major renovation v.4, BREEAM UK Non-Domestic Refurbishment and Fit-out 2014. Based on the analysis results, we propose the improvement direction of G-SEED Green Remodeling Certification Standard. Result: Existing buildings should be classified into 'existing building certification' for re-certification and 'green remodeling certification' accompanied by building performance improvement. In addition, building green buildings through performance improvement should include not only energy performance, but also creating a pleasant indoor environment and minimizing environmental impact. Finally, existing buildings have accumulated information on energy and resource use, and a performance improvement plan should be established based on this information.

2050년 국내 건물 부문의 온실가스 감축을 위한 탄소중립 시나리오 연구 (2050 Carbon-neutrality scenario to reduce greenhouse gas emissions in domestic building sector)

  • 최지우;정학근;김형준
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.396-396
    • /
    • 2023
  • 기후 위기에 대한 대응으로 현재 많은 국가에서 2050년 탄소중립을 목표로 하고 있으며, 우리나라도 2050년까지 탄소중립을 선언하고 다양한 부문의 배출 절감 계획을 내세웠다. 현재 건물 부문에서는 2050년의 목표배출량을 6.2 백만톤 CO2eq으로 설정하고 관련 정책적 수단을 검토 중이지만 달성 방안 등에 대해서는 구체적으로 제시하지 못하고 있다. 본 연구에서는 국내 건물 부문의 이산화탄소의 배출량 산정 모델을 개발하여, 2050년까지 이산화탄소 배출 저감 시나리오를 시뮬레이션하였다. 이를 토대로 국내의 건물 부문 탄소중립 가능성을 검토한 통합 시나리오를 제시하고, 향후 정책 및 기술 개발의 방향성을 제시한다. 탄소배출량 산정모델은 연면적 예측 및 사용 에너지의 원단위 환산, 탄소배출계수 등을 고려해 개발하였고, 이를 활용하여 4가지 탄소배출 시나리오를 분석하였다. 먼저 현재 정책 기반 탄소 배출 시나리오는 탄소중립에 이르지 못하여 더 강화된 시나리오의 필요성을 보여준다. 신규 건물을 대상으로 한 제로 에너지화 제도 기반 시나리오는 전체 탄소배출량에 큰 기여를 하지 못하며, 기존 건물 대상의 그린 리모델링 제도 기반 시나리오에서는 10년 이상 건물에 50% 이상의 높은 에너지 효율 개선을 시행해야 한다는 결과를 도출하였다. 또한 전기화 시나리오에서는 화석연료와 전력의 탄소배출계수를 비교하여 적절한 에너지 전환 시점을 계산하였다. 그 결과, 건물 부문에서 2050년까지 탄소배출량 감축 목표 달성을 위해 신축 건물의 에너지 자립율 100%, 에너지 전환 계획과 연동한 건물의 전기화, 그리고 그린리모델링을 통한 효율 개선 기준을 47% 이상 달성하는 조건을 만족해야 한다는 결과를 얻었다. 이 연구는 도전적인 온실가스 감축 마련의 필요성을 제시하였으며, 탄소중립 가능성을 제시하여 실질적인 감축정책에 기여할 것으로 기대한다.

  • PDF

노후 보건소의 그린리모델링을 통한 에너지 및 탄소배출 저감효과 분석 (Analysis on the Energy and GHG Emissions Reduction Effect of Old Public Health Centers through Green-remodeling)

  • 조정흠;오진환;강연주;남유진
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.18-26
    • /
    • 2023
  • Green-remodeling is to improve the energy performance of existing buildings that have been aged for more than 15 years since completion. In order to achieve the national greenhouse gas emission reduction plan in the building sector, it is necessary to analyze the carbon reduction effect by considering the internal carbon emissions that may occur during green-remodeling of old buildings. This study analyzed the effects of energy reduction and carbon emission reduction when green-remodeling was applied to old health centers constructed in 1992. When applying green-remodeling, the carbon emission reduction effect considered the embodied carbon emission of the improvement items and the carbon emission at the building operation stage. When applying green-remodeling to existing buildings, energy consumption was reduced by 39.3%, and carbon emissions were reduced by 48.9% after 27 years of green-remodeling. In order to reduce carbon emissions, it was important to apply a renewable system as an item to improve the performance of green-remodeling. In particular, it was confirmed that it is very important to consider the photovoltaic system as a top priority for the carbon emission reduction.