• Title/Summary/Keyword: 균질

Search Result 2,094, Processing Time 0.026 seconds

Effects of High Pressure Homogenization on Physicochemical Properties of Starch Films (고압균질처리가 전분필름의 물성에 미치는 영향)

  • Kang, Eun-Jung;Lee, Jae-Kwon
    • Food Engineering Progress
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • The effects of high pressure homogenization (microfluidization) on physicochemical properties of normal maize and oxidized maize starch film were studied. The molecular dispersibility of amlyose and amylopectin and the disintegration of granular structure had a marked effect on the physicochemical properties of starch films. The high pressure homogenized starch films showed increased solubility and transmittance due to the absence of gelatinized starch granules. The tensile strength of starch film increased significantly with decreasing oxygen permeability after high pressure homogenization, indicating that starch molecules were more uniformly and fully dispersed during the film formation. As a result, a clear starch film with improved mechanical properties was obtained after high pressure homogenization due to the increased interactions between the uniformly dispersed starch molecules.

Preparation of Heterogeneous Bipolar Membranes Using Poly (phenylene oxide, PPO) Polyelectrolyte and Their Water Splitting Properties (Poly (phenylene oxide, PPO) 고분자 전해질을 이용한 불균질 바이폴라막 제조 및 물분해 특성)

  • Kim, In Sik;Hwang, Seong Yeon;Kang, Byung Gwan;Hwang, Taek Sung
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • In this study, heterogeneous ion exchange membranes were prepared by casting method with various mixing ratios of PPO ion-selective solution and ion exchange resin. Then heterogeneous bipolar membranes were prepared by using this. The water content of heterogeneous cation and anion exchange membranes were 60~80% respectively, the ion exchange capacity was 2.81~3.26 meq/g, 2.31~2.74 meq/g and electrical resistances were $1.65{\sim}1.45{\Omega}{\cdot}cm^2$ and $1.55{\sim}1.05{\Omega}{\cdot}cm^2$. The tensile strength of heterogeneous bipolar membrane was lower than that of PPO resin before functionalization ($700Kg_f/cm^2$). The tensile strength of heterogeneous bipolar membrane with catalyst layer was lower than that of non-catalytic heterogeneous bipolar membrane. The water splitting voltage of the heterogeneous bipolar membrane with catalyst layer was low and stable at a minimum of 1.7~1.8 V, maximum 3.9~4.0 V, and the water splitting voltage of the non-catalytic heterogeneous bipolar membrane was constant at 3.8~4.0 V.

Effect of Pre-Rolling on the Mechanical Properties of AI-Mg-Mn Alloy (Al-Mg-Mn합금의 기계적(機械的) 성질(性質)에 미친 여비압재(予備圧在)의 영향(影響))

  • Ye, Gil-Chon;Maeng, Sun-Chae
    • Applied Microscopy
    • /
    • v.4 no.1
    • /
    • pp.5-10
    • /
    • 1974
  • In this work the effect of pre-rolling on the homogenization and on the mechanical properties of 4.6% Mg-0.5% Mn-0.18% Cr-Al alloy has been studied. At room temperature tensile strength and elongation have been found to increase in the pre- rolled homogenized sample compared to those of the as cast sample. At $400^{\circ}C$ this pre-rolled homogenized sample has shown a little lower tensile strength and a remarkably higher elongation than the samples as casted or homogenized without pre-rolling. Metallurgical microstructure of the pre-rolled homogenized sample has shown conspicuously less secondary phase such as ${\beta}$-phase at the grain boundaries than the other samples. The difference of magnesium content between grain boundaries and within the grains has been also checked by EPMA. The test results show enhanced homogenizing effect by the pre-rolling before homogenizing heat treatment.

  • PDF

Effect of Inhomogeneity correction for lung volume model in TPS (Lnug Volume을 모델로 한 방사선치료계획 시 불균질 조직 보정에 따른 효과)

  • Chung SeYoung;Lee SangRok;Kim YoungBum;Kwon YoungHo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2004
  • Introduction : The phantom that includes high density materials such as steel was custom-made to fix lung and bone in order to evaluation inhomogeneity correction at the time of conducting radiation therapy to treat lung cancer. Using this, values resulting from the inhomogeneous correction algorithm are compared on the 2 and 3 dimensional radiation therapy planning systems. Moreover, change in dose calculation was evaluated according to inhomogeneous by comparing with the actual measurement. Materials and Methods : As for the image acquisition, inhomogeneous correction phantom(Pig's vertebra, steel(8.21g/cm3), cork(0.23 g/cm3)) that was custom-made and the CT(Volume zoom, Siemens, Germany) were used. As for the radiation therapy planning system, Marks Plan(2D) and XiO(CMS, USA, 3D) were used. To compare with the measurement value, linear accelerator(CL/1800, Varian, USA) and ion chamber were used. Image, obtained from the CT was used to obtain point dose and dose distribution from the region of interest (ROI) while on the radiation therapy planning device. After measurement was conducted under the same conditions, value on the treatment planning device and measured value were subjected to comparison and analysis. And difference between the resulting for the evaluation on the use (or non-use) of inhomogeneity correction algorithm, and diverse inhomogeneity correction algorithm that is included in the radiation therapy planning device was compared as well. Results : As result of comparing the results of measurement value on the region of interest within the inhomogeneity correction phantom and the value that resulted from the homogeneous and inhomogeneous correction, gained from the therapy planning device, margin of error of the measurement value and inhomogeneous correction value at the location 1 of the lung showed $0.8\%$ on 2D and $0.5\%$ on 3D. Margin of error of the measurement value and inhomogeneous correction value at the location 1 of the steel showed $12\%$ on 2D and $5\%$ on 3D, however, it is possible to see that the value that is not correction and the margin of error of the measurement value stand at $16\%$ and $14\%$, respectively. Moreover, values of the 3D showed lower margin of error compared to 2D. Conclusion : Revision according to the density of tissue must be executed during radiation therapy planning. To ensure a more accurate planning, use of 3D planning system is recommended more so than the 2D Planning system to ensure a more accurate revision on the therapy plan. Moreover, 3D Planning system needs to select and use the most accurate and appropriate inhomogeneous correction algorithm through actual measurement. In addition, comparison and analysis through TLD or film dosimetry are needed.

  • PDF

Facies Analysis of the Early Mesozoic Hajo Formation in the Chungnam Basin, Boryeong, Korea (보령지역 충남 분지 중생대 초기 하조층의 퇴적상 분석)

  • Lee, Sin-Woo;Chung, Gong-Soo
    • Journal of the Korean earth science society
    • /
    • v.31 no.1
    • /
    • pp.18-35
    • /
    • 2010
  • Facies analysis of the Late Triassic Hajo Formation, the lowest stratigraphic unit in the Chungnam Basin, shows that the lower part is composed mainly of breccias or conglomerates; the middle part, conglomerates; and the upper part, conglomerates and sandstones. The formation consists of 13 facies, which include horizontally stratified clastsupported conglomerate, clast-supported massive breccia, matrix-supported massive breccia or conglomerate, matrixsupported graded conglomerate, massive pebbly sandstone, horizontally laminated sandstone, massive sandstone, graded sandstone, inversely graded sandstone, planar cross-bedded sandstone, trough cross-bedded sandstone, low angle crossbedded sandstone, and massive mudstone. These are grouped into 4 facies associations (FA). FA I consisted of clastsupported and matrix-supported massive breccias presumably deposited in the talus or upper fan delta environment. FA II consists of matrix-supported massive conglomerate and horizontally stratified clast-supported conglomerate of cobble size and it seems to have been deposited in the upper fan delta environment. FAIII consisted of matrix-supported massive conglomerate of pebble size, horizontally laminated sandstone and massive sandstone may have been deposited in the middle fan delta environment. FAIV consists of massive pebbly sandstone, horizontally laminated sandstone and massive sandstone and presumably was deposited in the lower fan delta environment. In general the Hajo Formation is interpreted to have been deposited at the talus/upper fan delta environment in early stage; it might have been deposited in the alternating environments of upper and middle fan delta in middle stage; and it seems to have been deposited in alternating environments of middle and lower fan delta in late stage.

Prediction of Homogenization Efficiency using Response Surface Methodology (반응표면분석을 활용한 균질 효율 예측)

  • Kang, Ho Jin;Kang, Shin Ho;Shin, Yong Kook
    • Journal of Dairy Science and Biotechnology
    • /
    • v.35 no.3
    • /
    • pp.202-207
    • /
    • 2017
  • The objective of this study was to analyze the effects of homogenization, storage temperature, and storage period on the creaming of milk fat and changes in fat contents in the upper and lower layers and to predict the conditions for optimal homogenization efficiency using response surface methodology (RSM). The homogenization pressure, storage temperature, and storage period were set as independent variables of RSM, and the dependent variables were creaming, US Public Health Service (USPHS) code, and volume weighted mean diameter ($D_{4,3}$) in the upper and lower layers. Based on the results of RSM and regression analysis, the correlation coefficient ($R^2$) between experimental data and predicted values by RSM for homogenized milk was estimated to be more than 0.8. The RSM analysis indicated that optimal homogenization pressures of 14 MPa or more and 17 MPa or more were required to maintain the creaming layer of 3 mm or less during the storage for 15 days at $10^{\circ}C$ and $20^{\circ}C$, respectively. To keep the USPHS code at less than 10% for 15 days at $10^{\circ}C$ and $20^{\circ}C$, milk should be homogenized with a pressure of 16.8 MPa or more and 17 MPa or more, respectively.

A Study of Heterogeneity Corrections for Radiation Treatment Planning (방사선 치료계획 시 불균질 보정에 관한 고찰)

  • Lee, Je-Hee;Kim, Bo-Gyum;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.89-96
    • /
    • 2006
  • Purpose: To study effectiveness of heterogeneity correction of internal-body inhomogeneities and patient positioning immobilizers in dose calculation, using images obtained from CT-Simulator. Materials and Methods: A water phantom($250{\times}250{\times}250mm^3$) was fabricated and, to simulate various inhomogeneity, 1) bone 2) metal 3) contrast media 4) immobilization devices(Head holder/pillow/Vac-lok) were inserted in it. And then, CT scans were peformed. The CT-images were input to Radiation Treatment Planning System(RTPS) and the MUs, to give 100 cGy at 10 cm depth with isocentric standard setup(Field Size=$10{\times}10cm^2$, SAD=100 cm), were calculated for various energies(4, 6, 10 MV X-ray). The calculated MUs based on various CT-images of inhomogeneities were compared and analyzed. Results: Heterogeneity correction factors were compared for different materials. The correction factors were $2.7{\sim}5.3%$ for bone, $2.7{\sim}3.8%$ for metal materials, $0.9{\sim}2.3%$ for contrast media, $0.9{\sim}2.3%$ for Head-holder, $3.5{\sim}6.9%$ for Head holder+pillow, and $0.9{\sim}1.5%$ for Vac-lok. Conclusion: It is revealed that the heterogeneity correction factor calculated from internal-body inhomogeneities have various values and have no consistency. and with increasing number of beam ports, the differences can be reduced to under 1%, so, it can be disregarded. On the other hand, heterogeneity correction from immobilizers must be regarded enough to minimize inaccuracy of dose calculation.

  • PDF

Evaluation of the Secondary Particle Effect in Inhomogeneous Media for Proton Therapy Using Geant4 Based MC Simulation (Geant4 몬테칼로 시뮬레이션을 활용한 불균질 매질에서의 양성자의 이차입자 영향 분석)

  • Park, So-Hyun;Jung, Won-Gyun;Rah, Jeong-Eun;Park, Sung-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.311-322
    • /
    • 2010
  • In proton therapy, the analysis of secondary particles is important due to delivered dose outside the target volume and thus increased potential risk for the development of secondary cancer. The purpose of this study is to analyze the influence of secondary particles from proton beams on fluence and energy deposition in the presence of inhomogeneous material by using Geant4 simulation toolkit. The inhomogeneity was modeled with the condition that the adipose tissue, bone and lung equivalent slab with thickness of 2 cm were inserted at 30% (Plateau region) and 80% (Bragg peak region) dose points of maximum dose in Bragg curve. The energy of proton was varied with 100, 130, 160 and 190 MeV for energy dependency. The results for secondary particles were presented for the fluence and deposited energy of secondary particles at inhomogeneous condition. Our study demonstrates that the fluence of secondary particles is neither influenced insertion of inhomogeneties nor the energy of initial proton, while there is a little effect by material density. The deposited energy of secondary particles has a difference in the position placed inhomogeneous materials. In the Plateau region, deposited energy of secondary particles mostly depends on the density of inserted materials. Deposited energy in the Bragg region, in otherwise, is influenced by both density of inserted material and initial energy of proton beams. Our results suggest a possibility of prediction about the distribution of secondary particles within complex heterogeneity.

Influence of Coating Materials and Emulsifiers on Nanoparticles in Manufacturing Process (코팅물질과 유화제가 나노입자 제조 및 안정성에 미치는 영향)

  • Kim, Byeong-Cheol;Chun, Ji-Yeon;Park, Young-Mi;Hong, Geun-Pyo;Lee, Si-Kyong;Choi, Mi-Jung
    • Food Science of Animal Resources
    • /
    • v.32 no.2
    • /
    • pp.220-227
    • /
    • 2012
  • The objective of this study was to investigate the influence of emulsion processing with various homogenization treatments on the physical properties of nanoparticles. For the manufacturing of nanoparticles, by taking the emulsion-diffusion method, various coating materials, such as gum arabic, hydroxyethyl starch, polycarprolactone, paraffin wax, ${\kappa}$-carrageenan and emulsifiers like Tween$^{(R)}$60, Tween$^{(R)}$80, monoglyceride and Pluronic$^{(R)}$F68, were added into the emulsion system. Furthermore, the various speeds (7,000 rpm to 10,000 rpm), and times (15 s to 60 s) of homogenization were treated during the emulsion- diffusion process. NEO II homomixer was the most effective homogenizer for making nanoparticles as 51 nm ($D_{10}$) and 26 nm ($D_{50}$). To manufacture smaller nanoparticles, by using NEO II homomixer, 10,000 rpm of agitation speed, polycaprolactone as coating material, and Pluronic$^{(R)}$F68 as an emulsifier were the optimum operating conditions and components. For the stability of nanoparticles for 7 days, $20^{\circ}C$ of storage temperature was appropriate to maintain the particle size. From these results, the type of homogenizer, homogenization speed, homogenization time and storage temperature could affect the particle size. Moreover, type of coating materials and emulsifier also influenced the size and stability of the nanoparticles.