• Title/Summary/Keyword: 균일입구유속

Search Result 13, Processing Time 0.032 seconds

LAMINAR FLOW IN THE ENTRANCE REGION OF HELICAL TUBES FOR UNIFORM INLET VELOCITY CONDITIONS (균일입구유속 조건의 나선관 입구영역의 층류 유동)

  • Kim, Y.I.;Park, J.H.
    • Journal of computational fluids engineering
    • /
    • v.13 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • A numerical study for laminar flow in the entrance region of helical tubes for uniform inlet velocity conditions is carried out by means of the finite volume method to investigate the effects of Reynolds number, pitch and curvature ratio on the flow development. This results cover a curvature ratio range of 1/10$\sim$1/320, a pitch range of 0.0$\sim$3.2, and a Reynolds number range of 125$\sim$2000. It has been found that the curvature ratio does significantly effect on the angle of flow development, but the pitch and Reynolds number do not. The characteristic angle $\phi_c(=\phi/\sqrt{\delta})$, or the non-dimensional length $\overline{l}(=l\sqrt{\delta}cos(atan\lambda)/d)$ can be used to represent the flow development for uniform inlet velocity conditions. In uniform inlet velocity conditions, the growth of boundary layer delays the flow development attributed to centrifugal force, and in which conditions the amplitude of flow oscillations is smaller than that in parabolic inlet velocity conditions. If the pitch increases or if the curvature ratio or Reynolds number decreases, the minimum friction factor and the fully developed average friction factor normalized with the friction factor of a straight tube and the flow oscillations decrease.

기체 방사성물질 제거용 활성탑 내에서의 유속분포 결정시험

  • 강덕원
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.88-94
    • /
    • 1996
  • 원자력발전소의 공조계통에 설치되어 운영되는 기체 방사성물질 제거용 첨착 활성탄 탑내에서 균일한 공기 유속분포가 유지되고 있는지를 확인하기 위한 실험을 실시하였다. 본 실험에 사용되는 장비(Tester for Flow Distribution, 이하 TFD라 함)는 원자력발전소에서 사용하는 첨착 활성탄 필터(Adsorber)내의 흡착층을 모방하여 자체에서 제작하였으며, 시험조건들은 실제의 값을 기준으로 적용하였다. 각 위치에서의 보정된 용적 유속을 구하기 위해 자체에서 만든 "FLOWD"라는 계산프로그램을 사용하였으며, 입구 및 출구측 공간에 10" 간격으로 각 6개씩 유속 감지기를 설치하여 면속도를 구하였다. 각 지점에서의 면속도는 평균 0.24449m/s로 각 구간에서의 겉보기 면속도의 분포는 매우 균일한 값을 나타내었으며, 약 2% 이내의 편차로 활성탄 탑내에서의 공기의 흐름이 균일하게 통과함을 확인할 수 있었다.통과함을 확인할 수 있었다.

  • PDF

A Study on the Flow Uniformity and Characteristics of Exhaust gas in Diesel Particulate Filter/Diesel Oxidation Catalyst of Ship Diesel Reduction System by Computational Fluid Dynamics (CFD에 의한 선박용 DPF/DOC내 배기가스의 유동 균일도 및 특성 연구)

  • Kim, YunJi;Han, Danbee;Baek, Youngsoon
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.153-160
    • /
    • 2019
  • As air pollution becomes more serious due to the increased number of diesel vessel operations, ship regulations on harmful emissions strengthen. Therefore, the development of a diesel exhaust after-treatment system for ships is required, and the higher the flow uniformity of the exhaust treatment system, the higher the treatment efficiency. With the computer software ANSYS Fluent, pressure drop and flow uniformity were used in this study to simulate flow rate with and without a baffle in both a Diesel Oxidation Catalyst (DOC) and Diesel Particulate Filter (DPF) system. The system pressure drop was found to be 38 to 40 mbar in the existing system condition, and the flow uniformity was approximately 84 to 92% at the inlet and outlet of the DOC. When the baffle was installed inside the system, the pressure increased and the flow uniformity was lowered due to an increase in flow rate. When the exhaust gas flow was reduced by 50% from $7,548kg\;h^{-1}$ to $3,772kg\;h^{-1}$, the flow uniformity at the inlet and outlet of the DOC increased by approximately 1 to 3% due to the low flow rate. In the case of DPF, the flow uniformity of exhaust gas was 98 to 99% because the uneven flow proceeded after uniformly flowing from the DOC.

Comparison of Injection Uniformity as the Dividing Plate Installation in Fuel Manifold (연료 매니폴드내의 분리판 장착에 따른 분사균일성 비교)

  • Yoo Doc-Koon;Cho Won-Kook;Seol Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.130-134
    • /
    • 2006
  • The injection uniformity of the fuel manifold in a liquid rocket engine has been analyzed with dividing plates to improve the cooling performance at the face plate. Three dimensional computational fluid dynamics analysis has been performed to compare the injection uniformity for 5 candidate designs and has been verified to compare with the measured data for the optimal manifold design. For the case I and II, the coolant mass flux increases as the whole working fluid is enforced to flow under the dividing plate. The injection uniformity decreases due to the variation of mass flux at the end of dividing plate and the concentration of mass flow rate at the center of manifold. However case III and IV have uniform injection performance due to reduced mass flux concentration as the coolant can flow along both upper passage and lower passage of the dividing plate. Among the candidate designs, case IV is thought to be the optimal dividing plate with regard to cooling performance and injection uniformity.

  • PDF

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

Numerical study of the influence of inlet shape design of a horizontal MOCVD reactor on the characteristics of epitaxial layer growth (수평 화학기상증착 반응기의 입구형상 설계가 단결정 박막증착률 특성에 미치는 영향에 관한 수치적 연구)

  • 정수진;김소정
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.5
    • /
    • pp.247-253
    • /
    • 2003
  • In this study, a numerical analysis of the deposition of gallium arsenide from TMGa and arsine in a horizontal MOCVD reactor is performed to investigate the effect of inlet diffuser shape of reactor on the flow and deposition characteristics. The effects of two geometric parameters (diffuser angle, diffuser shape) on the growth rate, growth rate uniformity, flow uniformity and pressure loss are presented. As a results, it is found that the optimum linear diffuser angle is in the range of $50^{\circ}$$55^{\circ}$ and parabolic diffuser in the range of $40^{\circ}$$45^{\circ}$ from the viewpoint of growth rate uniformity, flow uniformity and average growth rate. It is also found that variation of diffuser angle has greater impact on growth rate uniformity than average growth rate particularly in parabolic diffuser.

Flow Field Measurement in Catalytic Converter-Comparison with Computational Fluid Dynamics Analyses (촉매 변환기의 내부 유동장 측정-CFD 해석과 비교)

  • Yoo, Seoung-Chool;Jang, Sung-Kuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.3
    • /
    • pp.197-202
    • /
    • 2014
  • The efficiency of a catalytic converter depends on the flow distribution across a system's chemically active substrate. If irregularities or non-uniform flow patterns exist, the system's conversion efficiency decreases, whereas the manufacturing cost increases. Therefore, it is important to analyze the internal flow of a catalytic converter. In this study, flow pattern measurements along the minor axis were recorded at the mid and exit planes of a ceramic honeycomb catalytic converter at flow rates of 37.8 l/s and 94.4 l/s. Flow distributions of the measurement plans were compared with an automotive company's computed velocity profiles. Measurements along the minor axis showed uneven velocity profiles. The ${\upsilon}$-velocity components between the honeycomb bricks were small but somewhat erratic opposite the intake side of the converter, however, they became flatter in measurements recorded near the intake entrance. For almost all velocity values, the computer model suggested velocities greater than the measured values.

Optimization of inlet velocity profile for uniform epitaxial growth (균일한 에피층 성장을 위한 입구 유속분포 최적화)

  • Cho W. K.;Choi D. H.;Kim M.-U.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.11a
    • /
    • pp.121-126
    • /
    • 1998
  • A numerical optimization procedure is developed to find the inlet velocity profile that yields the most uniform epitaxial layer in a vertical MOCVD reactor. It involves the solution of fully elliptic equations of motion, temperature, and concentration; the finite volume method based on SIMPLE algorithm has been adopted to solve the Navier-Stokes equations. The overall optimization process is highly nonlinear and has been efficiently treated by the sequential linear programming technique that breaks the non-linear problem into a series of linear ones. The optimal profile approximated by a 6th-degree Chebyshev polynomial is very successful in reducing the spatial non-uniformity of the growth rate. The optimization is particularly effective to the high Reynolds number flow. It is also found that a properly constructed inlet velocity profile can suppress the buoyancy driven secondary flow and improve the growth-rate uniformity.

  • PDF

Flow Distribution in an Electrostatic Precipitator with a Perforated Plate (타공판에 따른 전기집진기 내의 유동분포)

  • Kim, Dong-uk;Jung, Sang-Hyun;Shim, Sung-Hoon;Kim, Jin Tae;Lee, Sang-Sup
    • Clean Technology
    • /
    • v.25 no.2
    • /
    • pp.147-152
    • /
    • 2019
  • Electrostatic precipitator that shows a good performance for the removal of particulate matter is important for controlling emissions from industrial facilities and power plants. The efficiency of the electrostatic precipitator on the removal of particulate matter is highly affected by the flow pattern inside the electrostatic precipitator. A number of studies have been conducted to obtain uniform flow distribution inside electrostatic precipitators. An electrostatic precipitator (ESP) with a length of 3.5 m and a height of 0.875 m was designed and installed in this study. The ESP included an inlet duct, diffuser, body, and contractor. Three perforated plates were installed in the diffuser of the ESP. Five pitot tubes were installed vertically and used to measure flow distribution in the cross section of the ESP body. Root mean square deviation value (RMS%) was used to examine the flow distribution inside the ESP when the perforated plates were installed in the diffuser. Flow distribution was also investigated in relation to the porosity of the perforated plate. The results showed that the perforated plates improved greatly the flow distribution inside the electrostatic precipitator. In addition, the most uniform flow distribution was found with 40%, 50%, and 50% porous perforated plates located from the inlet of the diffuser.

An Experimental Study on Effect of a Partitioned Electric Heating on Temperature Distribution in a Diesel Particulate Filter (분할형 전기히터 가열이 디젤 차량 배기가스저감장치 필터 내의 온도 분포에 미치는 영향에 관한 실험적 연구)

  • Lee, Choong-Hoon;Park, Sung-Chun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.151-157
    • /
    • 2008
  • The DPF temperature distribution which has a great effect on regenerating the ceramic filter effectively was measured at 30 locations using K-type thermocouples. Five partitioned electric heaters were used for heating the ceramic filter and they are switched ON/OFF in order. Also, the temperature distribution in the ceramic filter was measured with varying the electrical power supply to the heaters and the mass flow rate of the air supply from a blower. The uniform distribution of the air flow velocity at the inlet of the DPF make that of the temperature in the ceramic filter. The difference in heating ability between the partitioned heaters had a great effect on the temperature distribution in the ceramic filter.