• Title/Summary/Keyword: 굴절 경로

Search Result 140, Processing Time 0.033 seconds

Refinement of Interpretation Method for Reliable Vs Profiling in Downhole Seismic Method (다운홀 시험에서 신뢰성 있는 전단파 속도 주상도 도출을 위한 해석 기법의 개선)

  • Bang, Eun-Seok;Kim, Dong-Soo;Yoon, Jong-Ku
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.3C
    • /
    • pp.157-170
    • /
    • 2006
  • Downhole method is considered as giving a little unreliable Vs profile when the signal to noise ratio(S/N) is low and the travel time information is erroneous although it is economical and ease of operation. Direct method has been applied for obtaining adequate result in this case. But it is difficult to determine optimum result by using direct method which is subjective and considering straight ray path. Therefore, in this paper, Mean Refracted Ray Path Method(MRM) was proposed, which is automated and considering refracted ray path. Artificial travel time data adding some travel time error was generated by forward modeling based on Snell's Law and travel time data was also obtained from numerical signal traces using FEM modelling. Using these travel time data, reliability of MRM was verified in the manner of comparing the results determined by MRM with the model. Finally, proposed method was applied to the real field data and it was considered as improved method for obtaining the optimum result in downhole seismic method.

Analysis of Correlation by Myopic Refractive Errors and Intraocular Pressure (근시성 굴절이상과 안압의 상관관계 분석)

  • Kim, Bo-Yun;Lee, Eun-Hee;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.8
    • /
    • pp.317-321
    • /
    • 2020
  • This study researched the correlation between myopic refractive errors and intraocular pressure. The study population comprised 39 adults(17 of males, 22 of females). We measured the intraocular pressure using a Non-Contact Tonometer(NCT) and the correlation between myopic refractive errors was analyzed by dividing into three groups: mild, moderate, high myopia. The gender of subjects showed no statistically difference between the intraocular pressure and refractive errors, but as the refractive errors increased, the intraocular pressure incereased, which showed a statistically significant difference. In addition, the higher intraocular pressure in moderate and high myopia than mild myopia can cause glaucoma, that can develop at a young age. it is need to sufficient recognition and understanding correlation between intraocular pressure and myopic refractive errors in the middle-aged high myopia.

A Study About N.P.C, Heterophoria and Near Convergence and Divergence by Amount of the Refractive Errors (굴절이상도에 따른 폭주근점과 근거리 수평사위, 폭주 및 개산 여력의 연구)

  • Choi, Sun-Mi
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.53-57
    • /
    • 2009
  • Purpose: To study the relationship of N.P.C, heterophoria and near convergence and divergence by amount of the refractive error. Methods: All subjects have no ocular disease and their mean age is 22.7. All 39 subjects examined about refractive error, near point of convergence (NPC), heterophoria, near convergence and divergence. Results: Classified by low refractive state, middle refractive state, and high refractive state compared with the expected value of Morgan. NPC had been measured within low and middle refractive state eight all the 8cm. However, high refractive state measured 9.64 cm. Low and middle refractive state for the classification by near phoria. Near esophoria groups was smallest by near divergence and exophoria groups was smallest by near convergence. Conclusions: Near convergence were largest with esophoria while near divergence were largest with exophoria.

  • PDF

KVN 단일경을 이용한 대기 난굴절(Anomalous Refraction) 측정

  • Lee, Jeong-Ae;Byeon, Do-Yeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.220.2-220.2
    • /
    • 2012
  • 대기 중 수증기의 불규칙한 분포와 운동은 대기의 굴절율을 시간에 따라 불규칙하게 변화시킨다. 전파 관측 중 대기의 굴절율이 짧은 시간 동안에 크게 변하면 천체가 안테나 주빔의 중앙에서 벗어나는 것처럼 관측되고, 이는 마치 안테나 지향 오차가 커지는 것과 같은 효과를 준다. 이러한 현상을 대기 난굴절(Anomalous Refraction)이라고 한다. KVN 안테나 성능 시험 관측 중 심할 경우 수십초의 시간 규모에서 수십 각초 이상 안테나 지향 오차가 커지는 현상이 관측되어 각 사이트의 대기 난굴절 특성에 대하여 모니터링을 시행하였다. 22GHz와 43GHz에서 KVN 사이트의 대기 난굴절 특성을 파악하기 위하여 2010년 4월부터 2011년 4월까지 각 계절마다 세 사이트에서 시험 관측을 진행하였다. 관측 결과로부터 계절별, 낮과 밤등을 기준삼아 KVN 사이트의 대기 난굴절의 특성을 소개한다.

  • PDF

Estimation of Refractive Index in MIR range from the Reflectance Measurements for IR Optics Materials (반사율 측정에 의한 적외선 광학재료의 중적외선 굴절률 추정)

  • Jin, Doo-han;Jeong, Kyung-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.411-416
    • /
    • 2020
  • An optical arrangement has been set inside a photo-spectrometer to measure the reflectance of IR optics materials in mid IR range. The optical arrangement consists of equally spaced 4 gold coated full reflecting mirrors with the incidence angle of 45°. Baseline beam intensity IB has been measured while the beam proceeds through the 4 mirrors. Reflectance of a mirror has been estimated from the IB. And the beam intensity IS with the specimen in the optical path has been measured with the 4th mirror replaced with the specimen. Reflectance of the specimen has been estimated from the value of IS/IB. Then the estimated reflectance has been put in Fresnel equation relating reflectance and refractive index(RI) to estimate the RI of the material. Measurement has been made for sapphire, germanium, magnesium fluoride, and zinc sulfide. The estimated RI of the materials are closely matching with reference data and the maximum difference less than 2% over the wavelength range 3-5㎛ for all materials tested. As an FT-IR photo-spectrometer with a broadband wavelength infrared light source is used, this method has the advantage of measuring the refractive index at multiple wavelengths in a single measurement.

Refraction angle of the transverse wave near the longitudinal critical angle in angle beam transducer (종파 임계각 근처에서 사각 탐촉자의 횡파굴절각)

  • Lee Jeong-Ki;Lim Seong-Jin
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.303-306
    • /
    • 2000
  • 복잡한 형상을 지닌 터빈 블래이드의 결함을 검사하기 위해 현재 $35^\circ,\; 38^\circ,\; 40^\circ$의 횡파 굴절각을 지닌 탐촉자를 사용하고 있다. 이와 같은 굴절각은 초음파 빔의 경로를 Snell의 법칙에 의해 설정하고 있다. 그러나 터빈 블래이드 검사용 초음파 탐촉자를 제작하는 과정에서 $35^\circ$의 횡파 굴절각을 갖는 경사각 탐촉자는 제작이 어려움을 알았다. 이러한 원인은 철강재료의 종파임계각이 $33.2^\circ$의 횡과굴절각에 대응되며, 종파임계각 근처에서는 전반사 현상 때문에 에너지 투과율이 매우 작아 실제 시험대상체에 입사되는 에너지가 거의 없으며 또한 횡파굴절각이 약 $37.5^\circ$ 일때에 휭파의 에너지 투과율이 최대가 되어 wedge를 $37.5^\circ$ 이하의 횡파굴절각을 갖도록 설계하더라도 측정을 하면 $37.5^\circ$ 근처의 횡파굴 절각을 갖게된다. 즉, 종파임계각 근처에서는 전반사 현상에 의해 경계면에서의 에너지 투과가 매우 작아 횡파 굴절각은 Snell의 법칙이 아닌 초음파 에너지의 투과 정도를 나타내는 echo transmittance의 크기에 의해 결정된다.

  • PDF

Absolute Measurement of the Refractive Index of Air Using the Heterodyne Interferometer (Heterodyne 간섭계를 이용한 공기굴절율의 절대측정)

  • 엄태봉;엄천일;정명세;양준묵
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.37-43
    • /
    • 1996
  • Two type interference air refractometers have been developed by using a frequency stabilized He-Ne laser in a transverse magnetic field. The refractometers were based on symmetric multiple pass interferometer. In this system, One part of the beams passed through air whose refractivity is to be measured and the other part of the beams passed through a vacuum champer to be used as a reference. Several measurements were performed under normal air condition. Maximum difference between two interference refractometers was ${\pm}2{\times}10^{-8}$.

  • PDF

The Study of Corrected Lens and Dominant Eye in Elementary School (초등학교 아동의 우위안과 교정굴절력에 대한 연구)

  • Lee, Hak-Jun;Kim, Chang-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.53-56
    • /
    • 2003
  • After we compared the corrected len3 and the dominant eye who were wearing eyeglasses, elementary school in Iksan, we could get conclusions like these. 51 persons of the whole number, 65.4%, have the dominant eye of right. The refractive correlation to the spherical lens and astigmatic lens are the high non-dominant eye.

  • PDF

A study on the brilliance by critical angle of gem and measurement theory of refractive index using refractometer (보석의 임계각에 따른 휘광성 및 굴절계를 이용한 굴절률 측정 이론에 관한 연구)

  • Moon, So-I;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.105-109
    • /
    • 2011
  • Critical angle of quartz (R.I. ${\fallingdotseq}$ 1.553) and diamond (R.I. = 2.417) are $40.09^{\circ}$ and $24.26^{\circ}$ that calculated by $sin{\theta}=r_2/r_1$ (r = refractive index, $r_1$ > $r_2$). Brilliance of quartz and diamond are 20.33% and 55.07%. The brilliance data are result of study on the incident light internal round brilliant cut quartz and diamond by the critical angle. Cause of bow-tie phenomenon can be studied by application of critical angle theory and light path inside fancy shape brilliant cut. When refractormetry with typical gem refractometer, critical angle of quartz and corundum are $59.1^{\circ}$ and $77.9^{\circ}$.

The Change of Corneal Refractive Power by Everted Silicone Hydrogel Contact Lens Wear (역방향 실리콘 하이드로겔 렌즈 착용에 따른 각막 굴절력 변화)

  • Kim, Soo-Hyun;Shin, Dong-Min;Jeong, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.271-277
    • /
    • 2013
  • Purpose: The purpose was to study the corneal refractive power changes associated with the wearing of everted silicone hydrogel soft lenses. Methods: The corneal refractive power and corneal astigmatism were measured using corneal topographer (CT-1000, Shin-nippon Co., Japan) for checking change of corneal refractive power and objective refractive error was measured by auto-refractometer (Natural vision-K 5001, Shin-nippon Co., Japan). We measured at baseline and 1 week after lens wearing. Results: The correcting of corneal refractive power could be effective in low myopia. It's more effective to the higher power of greatest meridian of cornea and the more corneal astigmatism. 73% of subjects' refractive error was decrease less than 1 D and 17% of the subjects had an reverse effect (increase) occurs. The reduction of objective refractive error was more effective when cornea refractive power was great or corneal astigmatism was much. Conclusions: Pressure which the everted silicone hydrogel lens to the cornea could be caused. It occurred as the degrees of corneal power, corneal astigmatism and objective refractive error differences. Selection of an appropriate subject is important considering difficulty of changing the parameters of the lens.