• Title/Summary/Keyword: 굴절차

Search Result 208, Processing Time 0.036 seconds

Individual Difference in the Decrease of Visual Acuity and the Change in Contrast Threshold According to the Level of Optically Induced Retinal Defocus (광학적으로 유발된 망막흐림의 정도에 따른 시력감소의 개인차와 인식 대비도의 변화)

  • Kim, Sang-Yeob;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.93-98
    • /
    • 2014
  • Purpose: We were aim to investigate individual difference of visual acuity (VA) decrease and the change of contrast threshold (CT) according to the level of optically induced retinal defocus. Methods: A total of 69 eyes were examined using consist of ten-graded decimal vision chart (Landolt's ring). After conducted full correction of subject's refractive error, a monocular VA and CT were measured according to sequential increase by 0.25 D each time. Results: VA gradually decreased according to the increase of retinal defocus level. Individual difference of VA decrease was range from 1.2 to 0.6 in retinal defocus induced by +0.25 D. When retinal defocus was induced as much as +0.50 D and +0.75 D, it was in the range of 1.0 to 0.3 and 0.9 to 0.1 respectively. With +1.00 D, some participants didn't even recognize the 0.1 in the chart. With +1.75 D, whole participant did not recognize the 0.1. Also, CT was gradually decreased with increase of the retinal defocus level. Conclusions: Examiners should consider individual difference in the decrease of VA according to the level of residual refractive error when determining final prescription of a patient.

Refractive Error Induced by Combined Phacotrabeculectomy (섬유주절제술과 백내장 병합수술 후 굴절력 오차의 분석)

  • Lee, Jun Seok;Lee, Chong Eun;Park, Ji Hae;Seo, Sam;Lee, Kyoo Won
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1173-1180
    • /
    • 2018
  • Purpose: We evaluated the postoperative accuracy of intraocular lens power prediction for patients undergoing phacotrabeculectomy and identified preoperative factors associated with refractive outcome in those with primary open-angle glaucoma (POAG). Methods: We retrospectively reviewed the medical records of 27 patients who underwent phacotrabeculectomy to treat POAG. We recorded all discrepancies between predicted and actual postoperative refractions. We compared the data to those of an age- and sex-matched control group that underwent uncomplicated cataract surgery during the same time period. Preoperative factors associated with the mean absolute error (MAE) were identified via multivariate regression analyses. Results: The mean refractive error of the 27 eyes that underwent phacotrabeculectomy was comparable to that of the 27 eyes treated via phacoemulsification (+0.02 vs. -0.01 D, p = 0.802). The phacotrabeculectomy group exhibited a significantly higher MAE (0.65 vs. 0.35 D, p = 0.035) and more postoperative astigmatism (-1.07 vs. -0.66 D, p = 0.020) than the phacoemulsification group. The preoperative anterior chamber depth (ACD) and the changes in the postoperative intraocular pressure (IOP) were significantly associated with a greater MAE after phacotrabeculectomy. Conclusions: POAG treatment via combined phacoemulsification/trabeculectomy was associated with greater error in terms of final refraction prediction, and more postoperative astigmatism. As both a shallow preoperative ACD and a greater postoperative change in IOP appear to increase the predictive error, these two factors should be considered when planning phacotrabeculectomy.

Analysis of Harmonic Wave Generation in Nonlinear Oblique Crack Surface (비선형 경사 균열면에서의 고조파 발생 특성 해석)

  • Kim, Noh-Yu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.376-387
    • /
    • 2012
  • Based on the nonlinear spring model coupled with perturbation method, 2nd harmonic waves generated by oblique incident ultrasound on nonlinear crack interface were calculated and investigated. Reflected and transmitted waves from the interface were determined and analyzed at various angle of incidence for the cracks with different interfacial stiffness in order to estimate the 2nd harmonic generation of incident ultrasound. It was shown in computer simulation that the 2nd harmonic components changed much with the increase of incidence angle in both reflected and transmitted wave, but became very small when the incident angle approached toward 90 degree. It can be concluded that the 2nd harmonic component of reflected wave has a meaningful amplitude as much as the transmitted 2nd harmonic wave from partly closed crack.

A Study of the Epidemiology of Refractive Error in Adult Korean (한국 성인의 굴절이상에 관한 역학조사)

  • Choi, Hae-Jung;Chen, Ko-Hsien;Cha, Jung-Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.2 no.1
    • /
    • pp.133-143
    • /
    • 1997
  • A population-based study of people aged above 20 years showed that 32% had emmetropia and 68% had ammetropia(myopia 56.6%. hyperopia 11.4%) city in Korea. The percentage of ammetropia in population based study is higher than that of clinic(O.P.D.) based. A 83.3% of the ammetropia had myopia. which is higher than 76.3% of 1968 and 76.9% of 1975 years. A 16.7% of the ammetropia had hyperopia. which is lower than 19.4% of 1968 and 17.3% of 1975 years. In the kind of refractive error. 32.1% of 985 eyes examined had compound myopic astigmatism. 18.2% had simple myopic astigmatism. 14.2% had simple myopia. 6.8% had simple hyperopic astigmatism, 5.0% had mixed astigmatism, 4.7% had compound hyperopic astigmatism and 3.6% had simple hyperopia. In the difference of binocular refractive error, 29% had 0.50~2.00 Dptr difference and 3.6% had difference above 2.00 Dptr. In age related myopic refractive error, 76.7% of people aged 20~29 years and 74.0% of 30~39 years had myopia. It is due to overstudy for entrance into a university that the percentage of myopia is higher than that of abroad. In age related hyperopic refractive error, 2.9% of people aged 20~29 years, 0.6% of 30~39 years. 6.3% of 40~49 years, 16.0% of 50~59 years and 63.9% of 60~69 years had hyperopia. It shows that the age related hyperopic refractive error was significantly increased at aged 40~49 years. The right eye had more myopic refractive error than left eye.

  • PDF

Identification of high-dip faults utilizing the GRM technique of seismic refraction method(Ⅰ) - Computer modeling - (굴절파 GRM 해석방법을 응용한 고경사 단층 인지(Ⅰ) - 컴퓨터 모델링 연구 -)

  • Kim, Gi Yeong
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.1
    • /
    • pp.57-64
    • /
    • 1999
  • To effectively identify near-surface faults with vertical slips from seismic refraction data, the GRM interpretation technique is tested and investigated in terms of various parameters through computer modeling. A characteristic change in shape of the velocity-analysis function near faults is noticed, and a new strategy of `Slope Variation Indicator (SVI)' is developed and tested in this study. The SVI is defined as a first horizontal derivative of the difference of velocity analysis functions for a large XY value and a small one, respectively. As the dip of refractor decreases and as the difference in XY value increases, the peak value of SVI increases and its duration decreases. Consequently, the SVI indicates accurately the location of buried fault in the test models. The SVI is believed to be an efficient tool in seismic refraction method to investigate location and distribution of shallowly buried faults.

  • PDF

Removal of Super-Refraction Echoes using X-band Dual-Polarization Radar Parameters (X-밴드 이중편파 레이더 변수를 이용한 과대굴절에코 제거)

  • Seo, Eun-Kyoung;Kim, Dong Young
    • Journal of the Korean earth science society
    • /
    • v.40 no.1
    • /
    • pp.9-23
    • /
    • 2019
  • Super-refraction of radar beams tends to occur primarily under a particular vertical structure of temperature and water vapor pressure profiles. A quality control process for the removal of anomalous propagation (AP) ehcoes are required because APs are easily misidentified as precipitation echoes. For this purpose, we collected X-band polarimetric radar parameters (differential reflectivity, cross-correlation coefficient, and differential phase) only including non-precipitation echoes (super-refraction and clear-sky ground echoes) and precipitation echoes, and compared the echo types regarding the relationships among radar reflectivities, polarimetric parameters, and the membership functions. We developed a removal algorithm for the non-precipitation echoes using the texture approach for the polarimetric parameters. The presented algorithm is qualitatively validated using the S-band Jindo radar in Jeollanam-do. Our algorithm shows the successful identification and removal of AP echoes.

Corneal Asphericity and Optical Performance after Myopic Laser Refractive Surgery (굴절교정수술을 받은 근시안의 각막 비구면도와 광학적 특성 평가)

  • Kim, Jeong-Mee;Lee, A-Young;Lee, Koon-Ja
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.179-186
    • /
    • 2013
  • Purpose: To compare corneal asphericity, visual acuity (VA), and ocular and corneal higher-order aberrations (HOAs) between myopic refractive surgery and emmetropia groups. Methods: Twenty three subjects ($23.0{\pm}2.5$ years) who underwent myopic refractive surgery and twenty emmetropia ($21.0{\pm}206$ years) were enrolled. The subjects'criteria were best unaided monocular VA of 20/20 or better in both two groups. High and low contrast log MAR visual acuities were measured under photopic and mesopic conditions. Corneal and ocular HOAs were measured using Wavefront Analyzer (KR-1W, Topcon) for 4 mm and 6 mm pupils. Corneal asphericity was taken by topography in KR-1W. Results: There was no significant difference in VA between two groups under either photopic or mesopic conditions. In ocular aberrations, there were significant differences in total HOAs, fourthorder and spherical aberration (SA) for a 6 mm between two groups (p=0.045, p<0.001, and p<0.001, respectively). In corneal aberrations, there was a significant difference in SA for 4 mm (p=0.001) and 6 mm (p<0.001) pupils between two groups and there were statistically significant differences in total HOAs (p<0.001) and fourth-order aberrations (p<0.001) between two groups for a 6 mm pupil. There was a significant correlation in emmetropia between Q-value and SA in ocular aberrations for 4 mm and 6 mm pupils (r=0.442, p=0.004, and r=0.519, p<0.001) and in corneal aberrations for 4 mm and 6 mm pupils (r=0.358, p=0.023, and r=0.646, p<0.001). No significant correlations were found between Q-value and SA in refractive surgery group. Conclusions: VA in myopic refractive surgery is better than or similar to emmetropia. Nevertheless, the more increasing pupil size is, the more increasing aberrations are. Thus, it could have an influence on the quality of vision at night.

Bending Characteristics Change of Long-Period fiber Grating due to Co-doping of Boron for Optical fiber Sensors (광섬유 센서 구성을 위한 보론 첨가에 따른 장주기 광섬유 격자의 구부림 특성 변화)

  • Moon, Dae-Seung;Chung, Young-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.339-342
    • /
    • 2005
  • In long-period fiber grating (LPFG) to be made up optical fiber sensors, resonance coupling occurs between the forward-propagating core mode and cladding modes at the wavelength that satisfy the Phase matching condition. The resonance wavelength and the coupling strength depends strongly on the external environment like temperature, strain, and ambient index. These characteristics can be utilized for various applications as optical fiber sensors. fabrication of optical fiber gratings is typically based on the photosensitivity effect, i.e. the permanent change of the refractive index upon irradiation of the UV beam, and therefore, fabrication of the optical fiber with high phososensitivity is an important part of the research on optical fiber gratings. In this work, we measured the effort of to-doping of boron on the index difference between the core and cladding of the optical fiber and the sensitivity of the LPFC to the temperature and bending changes. We observed that the index difference between the core and the cladding decreased by $(1.69{\times}10^{-4}/SCCM)$ and the temperature sensitivity of the resonance wavelength shirt decreased by $(0.01145nm/^{\circ}C/SCCM)$. The dependence or the bending-induced changes or the transmission characteristics of LPFG on the tore-cladding index difference was investigated experimentally. The measurement results indicate that the bending sensitivity increases as the index difference decreases.

Relationship of Visual Acuity and Refractive Error in Elementary School Students (초등학생들의 굴절이상과 시력과의 관계)

  • Park, Eun-Kyu
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.4
    • /
    • pp.141-143
    • /
    • 2008
  • Purpose: This study investigated visual acuity and refractive error in elementary schoolchildren and examined relationship between visual acuity and refractive error. Methods: Naked visual acuity and refractive error for selected 200 schoolchildren (400 eyes) of 1st, 3rd and 6th grades. Results: The refractive error in hyperopia was gradually decreased and visual acuity was increased as higher grade. The regression line of Y=2.1471X-3.1484 (F=313.9377, P<0.001) and closed inter-relationship were found between visual acuity and refractive error in myopia. The regression line equation of Y=-0.6854X+1.1764 (F=7.054, P<0.01) and closed inter-relationship were found between visual acuity and refractive error in hyperopia. The relationship between visual acuity and refractive error in astigmatism was Y=2.2509X-2.8738 (F=21.7952, P<0.001) and closed inter-relationship was found. Conclusions: Myopia, hyperopia and astigmatism showed closed inter-relationship with visual acuity.

  • PDF

Evaluation for dispersive refractive indices in IR regions of amorphous and crystalline $Ge_2Sb_2Te_5$ thin films (비정질 $Ge_2Sb_2Te_5$ 박막의 IR 영역에서의 복소굴절률 평가)

  • Kim, Jin-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.334-345
    • /
    • 2008
  • 컴퓨터의 발달과 더불어 현대사회는 기록하고 보존해야할 정보의 양이 점점 방대해 지고 있다. 그로 인해 자기기록매체처럼 정보를 사용자의 편의에 따라 반복적으로 기록하고 재생할 수 있는 광기록매체에 대한 관심이 증가되고 있다. $Ge_2Sb_2Te_5$(GST)는 기존의 CD-RW나 Floppy Disk(FD)를 대체할 차세대 기록매체로 주목받고 있다. 따라서 본 연구에서는 비정질상과 결정상으로 변하는 성질을 가지고 있는 GST롤 상변화 기록매체로서 이용하기 위해 굴절률을 평가하였다. 시료는 5N의 순도를 갖는 Ge, Sb, Te 물질을 준비하고 조성비에 맞추어서 석영관에 진공 봉입한 후 용융-냉각법으로 벌크를 제작하였고 열증착 방법으로 Si 및 유리 기판위에 1000nm 두께로 박막을 제작하였다. UV-Vis-IR spectrophotometer를 사용하여 반사도와 투과도를 측정하였고 측정한 스펙트럼을 이용하여 Swanepoel method로 굴절률을 계산하였다. 본 연구진이 자체 개발한 계산툴에 실험값을 대입하였고 실험에 의해 얻은 투과도와 계산툴에 의해 얻은 투과도 스펙트럼을 비교하였다.

  • PDF