• 제목/요약/키워드: 굴뚝

검색결과 163건 처리시간 0.02초

모세관 전지영동법에 의한 굴뚝에서 포집된 NaOH 용액속의 염소이온의 측정 (Determinaton of Chloride Ion Captured into Strong NaOH Solution from Chimney by Capillary Electrophoresis)

  • 임인덕;성용익;김양선;임흥빈
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.327-333
    • /
    • 1999
  • Determination of chloride ion in concentrated NaOH solution by capillary electrophoresis has been studied. The analysis was performed by indirect UV absorption detection using chromate buffer at 254nm. The matrix effect of the sample has been observed so that the sensitivity in strong NaOH solutaion has decreased up to 10% of that in distilled water. The pH effect of the sample on the sensitivity of CE peaks has been investigated. The method for increasing the sensitivity have been investigated and the optimum pH and concentration of the buffer were 7.5 and 10mM, respectively. A cationic surfactant cetyltrimethylammonium bromide(CTAB), was added to a buffer solution in order to reverse the electroosmotic flow(EOF) in the capillary. This results in a short analysis time and better peak shapes. Using this optimum condition, the determination of chloride ion in real environmental sample has been performed, which is captured in strong NaOH absorbent prepared for absorbing gas from chimney. The standard addition method has been applied for the quantitative analysis, and it was obtained the good reproducibility.

  • PDF

TMS용 실시간 영상 모니터링 시스템의 개발 (Development of Real-time TMS Video Monitoring System)

  • 곽두성;김온;조기량
    • 한국정보통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1072-1076
    • /
    • 2009
  • 본 논문에서는 환경 사고에 대해 사전 예방 조치에 주안점을 둔 TMS(굴뚝배출가스 감시시스템)용 실시간 영상 모니터링 시스템을 제안하였다. 기존 시스템의 문제점을 보완하기 위하여, 제안한 시스템에서는 실시간 대기오염 물질의 분석 수치와 영상 신호를 동시에 모니터 상에 나타내며 이를 통하여 대기오염물질의 실시간 감시가 가능하도록 하였다. 또한, 본 논문에서 제안한 시스템에서는 대기오염물질의 실시간 추이를 산업체의 환경부서 담당자나 운전원이 아니라도 확인이 가능하다.

전원주택의 벽난로와 관련된 화재사례의 분석 (A Case Study on Fire Investigation for a Wood-Burning Stove in an Idyllic House)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.119-128
    • /
    • 2015
  • 이 논문에서는 신축 후 약 2년이 경과한 전원주택에서 벽난로 가동 중에 벽난로로 인한 화재가 발생하여 전소된 사례에 대해 법원을 통해 소방서, 경찰서, 화재보험관련 조사기관, 주택을 시공한 건설회사와 벽난로를 시공한 벽난로제조업체로부터 제공받은 자료들을 분석하여 벽난로 옆 벽체의 목재기둥에 남아 있는 저온장기발화의 화재패턴을 근거로 벽난로 옆 벽체의 목재기둥에 벽난로 화실(火室)의 열이 전도되어 화재가 발생하였음을 입증하였다. 그리고 벽난로 옆의 목재기둥이 저온장기발화를 한 이유는 굴뚝에 환기를 위한 공기창을 설치하지 않았기 때문임을 화재시뮬레이션을 통해 입증하였다.

복합적층 원뿔형 쉘의 자유진동에 관한 기하학적 형상의 영향 (Effects of Geometrical Shape on the Free Vibration of Laminated Composite Conical Shells)

  • 손병직;지효선;장석윤
    • 한국강구조학회 논문집
    • /
    • 제14권4호
    • /
    • pp.519-527
    • /
    • 2002
  • 쉘 구조물은 지붕 구조물, 굴뚝 구조물, 압력구조물, 선박구조물, 항공구조물 등에 널리 사용되는 구조물이다. 본 논문은 전단변형 효과를 고려한 비등방성 복합성층 원뿔형 쉘의 자유진동에 관하여 연구하였다. 복합재료는 2개 또는 이상의 재료들로 구성되어 구조적인 효율성을 증진시키도록 구성된 재료이다. 이러한 복합재료로 구성된 구조물의 거동은 매우 복잡하기 때문에 해석해를 구하기가 거의 불가능하다. 따라서 본 연구에서는 이러한 복합재료로 구성된 원뿔형 쉘의 자유진동을 해결하는데 유한차분법을 사용하였다. 중심각, 정점각 및 다른 기하학적 파라미터의 진동에 대한 효과를 연구하였고, 진동모드 형상을 예시함으로서 진동모드에 관한 물리적 및 공학적인 이해를 증진시키고자 하였다.

발전소 굴뚝에서의 입자 분산에 대한 수치해석 (Numerical study of particle dispersion from a power plant chimney)

  • 심정보;유동현
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.173-182
    • /
    • 2017
  • An Eulerian-Lagrangin approach is used to compute particle dispersion from a power plant chimney. For air flow, three-dimensional incompressible filtered Navier-Stokes equations are solved with a subgrid-scale model by integrating the Newton's equation, while the dispersed phase is solved in a Lagrangian framework. The velocity ratios between crossflow and a jet of 0.455 and 0.727 are considered. Flow fields and particle distribution of both cases are evaluated and compared. When the velocity ratio is 0.455, it demonstrates a Kelvin-Helmholtz vortex structure above the chimney caused by the interaction between crossflow and a jet, whereas the other case shows flow structures at the top of the chimney collapsed by fast crossflow. Also, complex wake structures cause different particle distributions behind the chimney. The case with the velocity ratio of 0.727 demonstrates strong particle concentration at the vortical region, whereas the case with the velocity ratio of 0.455 shows more dispersive particle distribution. The simulation result shows similar tendency to the experimental result.

공동주택의 국소배기용 루프팬 성능개선에 관한 연구 (Study on the Performance Improvement of Roof Fan Used for Local Exhaust System Installed in Apartment)

  • 권용일;정열화;안정헌
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.136-141
    • /
    • 2012
  • Performance improvement of local exhaust system used in toilet and cooking place are main concern in a field of ventilation. In Korea, There are many high riser residential apartments in recent years. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depends on stack effect. This study investigates on the performance improvement of terminal device, roof fan, of vertical spiral duct used in high riser residential apartments. This paper focuses mainly on the effect of accessories, number or shape of blades, composed of roof fan with function of exhaust air volume of toilet and cooking place. Roof fan with 10 blades is observed at optimum exhaust performance in this study.

수치해석을 이용한 초고층 주거건물에서 외풍영향에 의한 외벽 압력 분포 분석 (A Numerical Analysis on the Outside Pressure Distribution by Outdoor Wind Effect in a High-rise Residential Building)

  • 김치완;양순창;안영철
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.639-645
    • /
    • 2011
  • The object of this study is to analyze and evaluate outdoor wind pressure effect in a high-rise residential building when seasonal wind blow on coast area. The target building consists of 3 tower buildings over 250m in height. For the evaluation of the outdoor wind effect, CFD simulation was performed. The results of the simulations are as follows : 1) In that case of high-rise building, horizontal stream is more affected than vertical stream. 2) In case of summer season northeasterly wind, building pressure distributions are unstable and surface pressures of outside are effected respectively. 3) In case of winter season westerly wind, building preassure differentiations are not so much because of screening effects of the B, and the C buildings. 4) In case of winter season northwesterly wind, front wind affects on the A building directly because of no obstacles.

초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가 (Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses)

  • 김영배;김재홍;성재용;이명호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

산업보건역학 연구사례 - 직업병 연구에서의 원인.결과 규명의 문제

  • 이원철;박정일;맹광호
    • 월간산업보건
    • /
    • 통권58호
    • /
    • pp.22-29
    • /
    • 1993
  • 직업과 질병, 이 문제는 산업의학의 출발점인 동시에 가장 중요한 내용중의 하나일 것이다. 그 한 예로 직업성 일을 살펴 본다면 1775년 Percuval Pott이 굴뚝청소부 소년들에게서 음낭암(scrotal cancer)이 과다하게 발생하는 것을 보고한 이래 많은 암종과 이에 관련된 폭로물질들의 관련성이 밝혀져 왔다. 이러한 문제들은 주로 일정한 암이 과다하게 발생함(epidemic; excessive prevalence)으로서 제기되기 시작하며, 원인-결과의 관련성을 밝혀내는 유용한 도구들 중의 하나인 역학적 방법은 그 해답을 찾는데에 큰 기여를 하고 있다. 그렇다면 어떠한 이론들을 근거로 하여 A가 B의 원인이라던가, A와 B는 관련이 없었던가 하는 겨론에 도달하게 되는가? 본란은 지금까지 그 관련성이 밝혀진 직업과 질병들을 소재로 하여 이들이 역학적으로 어떠한 과정을 통하여 원인-결과의 결론에 도달하게 되었는지를(또는 의심이 가기는 하나 왜 아직도 확실한 결론에 도달하지 못하였는지를) 설명하고자 한다. 본란의 내용을 이해하기 위하여는 기본적인 역학지식이 요구되기는 하나, 필요한 부분마다 이해를 돕기 위하여 설명을 첨가하였다. 다행히도 현재 '산업보건'에 연재되고 있는 '직업병의 역학적 연구방법'과 '한국의 산업의학' 1993년 Vol. 31, No. 2-4에 걸쳐 연재된 '산업보건역학'에 역학의 개념과 방법론에 대한 기본적인 내용이 서술되어 있으므로 이 분야를 처음 대하는 독자에게는 큰 도움이 될 것이다. 이번호에서는 '서론'의 형식을 빌어서 원인-결과관계를 판단하는데 있어서 가장 기본적으로 요구되는 조건들을 우선적으로 설명하고자 하였다. 여기에 설명한 개념들은 앞으로 계속 반복적으로 사용될 것이다.

  • PDF

적응형 TMS 면적식 유량계 (Adaptive TMS Variable Area Flow Meters)

  • 곽두성;김온;조기량
    • 한국정보통신학회논문지
    • /
    • 제12권3호
    • /
    • pp.590-595
    • /
    • 2008
  • 본 논문에서는 적응형 TMS(굴뚝배출가스 감시시스템) 면적식 유량계를 제안하였다. 이 유량계는 투명한 재질의 유리 테이퍼관 내부에 흐르는 유량의 증감에 따라 상하로 움직이는 플로트의 위치를 테이퍼관을 따라 일직선상으로 배열된 광센서로 검지하고, 설정한 값에 대응한 가스 유량이 가스 분석기에 인입되도록 실시간으로 서보모터 구동회로를 최적 제어하는 방법을 채택하였다. 제안한 유량계는 테이퍼 관에 흐르는 유량을 단계별로 검지할 수 있을 뿐만 아니라 연속적으로 유량을 제어하기 때문에 튜브라인의 막힘 현상이 발생할 가능성을 미연에 방지할 수 있다.