• Title/Summary/Keyword: 국소최적해

Search Result 132, Processing Time 0.028 seconds

Detection Schemes Based on Local Optimality and Sequential Criterion: 2. Performance Analysis (국소 최적성과 순차 기준을 바탕으로 한 검파 기법: 2. 성능 분석)

  • Choi Sang Won;Kang Hyun Gu;Lee Jumi;Park So Ryoung;Kim Sun Yong;Song Iickho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.1027-1035
    • /
    • 2005
  • In this paper, the performance of the sequential detection scheme proposed in Part 1 is compared with that of the fixed sample size (FSS) test, sequential probability ratio test (SPRT), and truncated sequential probability ratio test (TSPRT). The proposed sequential detection scheme requires less complexity and, in most cases, smaller sample size than the SPRT. It is also observed that the proposed sequential detection scheme has always lower complexity and smaller sample size than the FSS test and TSPRT.

Design of Unlike Split Triplet Impinging Element for Jet Mixing (혼합성능 개선을 위한 분리 삼중충돌 요소의 설계)

  • 조용호;김경호;윤웅섭
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.225-232
    • /
    • 2003
  • With an aim placed on its exploitation on practical injector design, liquid phase mixing due to unlike split triplet impinging element is experimentally investigated by a series of cold tests. Non-reacting kerosene/water spray simulates the kerosene/LOX propellant combination. Measurements of local mixture ratio distribution were made for different injection configurations and different momentum ratios. Mixing and mixing controlled characteristic velocity efficiencies are measured in terms of oxidizer/fuel jet momentum ratio from 0.5 to 8. Extent of mixing and its influence on hot performance are estimated in terms of mixing efficiency and mixing controlled characteristic velocity. Envelope of design locus for optimum mixing quality and corresponding maximum hot performance are proposed. Effects of momentum ratio, orifice diameter ratio and jet velocity ratios are also presented and discussed.

  • PDF

Performance Testing of Medical US Equipment Using US Phantom(ATS-539) (Focusing on Daegu Region) (초음파팬텀(ATS-539)을 이용한 의료용 초음파장비의 성능검사(대구지역을 중심으로))

  • Kim, Do-Hyung;Kwon, Deok-Moon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.295-305
    • /
    • 2014
  • This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

Fabrication and estimation of the plastic detector for measuring the contamination for beta-ray level of the kind of duct waste (배관류 폐기물의 베타선 오염도 측정용 플라스틱 검출기 제작 및 특성평가)

  • Kim Gye-Hong;Oh Won-Zin;Lee Kune-Woo;Seo Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.159-165
    • /
    • 2005
  • The characterization of radiological contamination inside pipes generated during the decommission of a nuclear facility is necessary before pipes can be recycled or disposed. But, existing direct measurements of radioactive contamination level using the survey-meter can not estimate the characteristic of contamination on a local area such as the pipe inside. Moreover, the measurement of surface contamination level using the indirect methods has many problems of an application because of the difficulty of collecting sample and contamination possibility of a worker when collecting sample. In this work, plastic scintillator was simulated by using Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. In addition, the problem of scintillator processing and transferring the detector into the pipe inside was considered when fabricating the plastic detector on the basis of simulation results. The characteristic of detector fabricated was also estimated. As a result, it was confirmed that detector capability was suitable for the measurement of contamination level. Also, the development of a detector for estimating the radiological characteristic of contamination on a local area such as the pipe inside was proven to be feasible.

  • PDF

An efficient 2.5D inversion of loop-loop electromagnetic data (루프-루프 전자탐사자료의 효과적인 2.5차원 역산)

  • Song, Yoon-Ho;Kim, Jung-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.68-77
    • /
    • 2008
  • We have developed an inversion algorithm for loop-loop electromagnetic (EM) data, based on the localised non-linear or extended Born approximation to the solution of the 2.5D integral equation describing an EM scattering problem. Source and receiver configuration may be horizontal co-planar (HCP) or vertical co-planar (VCP). Both multi-frequency and multi-separation data can be incorporated. Our inversion code runs on a PC platform without heavy computational load. For the sake of stable and high-resolution performance of the inversion, we implemented an algorithm determining an optimum spatially varying Lagrangian multiplier as a function of sensitivity distribution, through parameter resolution matrix and Backus-Gilbert spread function analysis. Considering that the different source-receiver orientation characteristics cause inconsistent sensitivities to the resistivity structure in simultaneous inversion of HCP and VCP data, which affects the stability and resolution of the inversion result, we adapted a weighting scheme based on the variances of misfits between the measured and calculated datasets. The accuracy of the modelling code that we have developed has been proven over the frequency, conductivity, and geometric ranges typically used in a loop-loop EM system through comparison with 2.5D finite-element modelling results. We first applied the inversion to synthetic data, from a model with resistive as well as conductive inhomogeneities embedded in a homogeneous half-space, to validate its performance. Applying the inversion to field data and comparing the result with that of dc resistivity data, we conclude that the newly developed algorithm provides a reasonable image of the subsurface.

Optimal Design Method for a Plasmonic Color Filter by Using Individual Phenomenon in a Plasmonic Hybrid Structure (복합 플라즈몬 구조에서의 개별 모드 동작을 이용한 플라즈모닉 컬러 필터 최적의 설계 방법)

  • Lee, Yong Ho;Do, Yun Seon
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.6
    • /
    • pp.275-284
    • /
    • 2018
  • In this study we propose a hybrid color-filter design method in which a nanohole array and a nanodisk array are separated by nanopillars of the material AZ 1500. We propose a design method for an RGB color filter, using the tendency of transmitted light according to each design variable. Especially we analyzed the intensity distribution of the electric field in the cross section, and set the height of the nanopillars so that the local surface-plasmon resonances generated in the two different arrays do not affect each other. The optical characteristics of the optimized color filter are as follows: In the case of the red filter, the ratio of the wavelength band expressing red in the visible broadband is 55.01%, and the maximum transmittance is 41.53%. In the case of the green filter, the ratio of the wavelength band expressing green is 40.20%, and the maximum transmittance is 42.41%. In the case of the blue filter, the ratio of the wavelength band expressing blue is 32.78%, and the maximum transmittance is 30.27%. We expect to improve the characteristics of color filters integrated in industrial devices by this study.

Usefulness of Low Dose Oral Contrast Media in $^{18}F-FDG$ PET/CT ($^{18}F-FDG$ PET/CT에서 저용량 경구용 조영제의 유용성)

  • An Young-Sil;Yoon Joon-Kee;Hong Seon Pyo;Joh Chul-Woo;Yoon Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.257-262
    • /
    • 2006
  • Purpose: The standard protocol using large volume of oral contrast media may cause gastrointestinal discomfort and contrast-related artifacts in PET/CT. The aim of this study was to evaluate the usefulness of low dose oral contrast in $^{18}F-FDG$ PET/CT. Materials and Methods: We retrospectively reviewed the whole-body PET/CT images in a total of 435 patients. About 200 ml of oval contrast agent (barium sulfate) was administered immediately before injection of $^{18}F-FDG$. The FDG uptake of intestines was analyzed by visual and semi- quantitative method on transaxial, coronal and saggital planes. Results: Seventy (16%, 113 sites) of 435 images showed high FDG uptake (peak SUV > 4); 50 (74%, 84 sites) with diffuse and 20 (15%, 29 sites) with focal uptake. The most commonly delivered site of oral contrast media was small bowel (n=27, 39%). On PET/CT images, FDG uptake coexisted with oral contrast media in 26 patients (54%, 38 sites) with diffuse pattern and 9 (45%, 9 sites) with focal pattern, and by sites, those were 38 (45%) and 9 (31%), respectively. In small bowel regions, the proportion of coexistence reached as high as 61% (29/47 sites). A visual analysis of available non-attenuation corrected PET images of 27 matched regions revealed no contrast-related artifact. Conclusion: We concluded that the application of low dose contrast media could be helpful in the evaluation of abdominal uptake in the FDG PET/CT image.

Role of Radiation Therapy for Stage III Thymoma (제 3기 흉선종에서 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.16-20
    • /
    • 2001
  • Purpose : To evaluate the effectiveness and tolerance of the postoperative radiation therapy for patients with Stage III thymoma and to define the optimal radiotherapeutic regimen Materials and Methods : We retrospectively analyzed the records of 24 patients with Stage III thymoma who were referred for postoperative radiation therapy in our institution from June, 1987 to May, 1999. Surgical therapy consisted of total resection in one patient, subtotal resection in seventeen, and biopsy alone in six patients. Age of the patients was ranged from 20 to 62 years with mean age of 47 years. Male to female ratio was 14 to 10. Radiation therapy was delivered with linear accelerator producing either 6 MeV or 10 MeV photons. The irradiated volume included anterior mediastinum and known residual disease. The supraclavicular fossae were not irradiated. The delivered total dose was ranged from 30 to 56 Gy. One patient received 30 Gy and eighteen patients received minimum of 50 Gy. Follow up period was ranged from 12 months to 8 years with median follow up of 40 months. Results : The overall local control rate for entire group of patients was $67\%$ at 5 years. The cumulative local failure rates at one, three and five year were $18\%,\;28\%\;and\;33\%$, respectively. In patients treated with subtotal resection and biopsy alone, local control rate was $76\%\;and\;33\%$, respectively. The actuarial observed survival rate at 5 years was $57\%$, and actuarial adjusted survival at 5 years was $72\%$. The difference between 5 year survival rates for patients treated with subtotal resection and biopsy alone was not statistically significant $(62\%\;vs\;30\%)$. Conclusion : We might conclude that postoperative radiation therapy was safe and effective treatment for patients with Stage III thymoma. Postoperative radiation therapy is recommended in cases where tumor margin is close or incomplete resection is accomplished.

  • PDF

Combined Transcatheter Arterial Chemoembolization and Local Radiotherapy for Unresectable Hepatocellular Carcinoma (절제불가능 원발성 간암에서 경간동맥 항암 색전술과 국소 방사선의 병용요법)

  • Seong Jinsil;Keum Ki Chang;Han Kwang Hyub;Lee Do Yun;Lee Jong Tae;Chon Chae Yoon;Moon Young Myoung;Kim Gwi Eon;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.159-165
    • /
    • 1998
  • Purpose : The best prognosis for hepatocellular carcinoma can be achieved with surgical resection. However, the number of resected cases is limited due to the advanced lesion or associated liver disease. A trial of combined transcatheter arterial chemoembolization(TACE) and local radiotherapy(RT) for unresectable hepatocellular carcinoma(HCC) was prospectively conducted and its efficacy and toxicity were investigated. Materials and Methods : From 1992 to 1994, 30 Patients with unresectable HCC due either to advanced lesion or to associated cirrhosis were entered in the study Exclusion criteria included the presence of extrahepatic metastasis, liver cirrhosis of Child's class C, tumors occupying more than two-thirds of the whole liver, and an ECOG scale of more than 3. Patient cHaracteristics were : mean tumor size $8.95\pm3.4cm$, serum AFP+ in all patients, portal vein thrombosis in all patients, liver cirrhosis in 22 patients, and UICC stage III and IVA in 10 and 20 patients, respectively. TACE was performed with the mixture of Lipiodol(5ml) and Adriamycin(50mg) and Gelfoam embolizatin. RT(mean dose $44.0\pm9.3Gy$) 10 days with conventional fractionation. Results : An objective response was observed in 19 patients($63.3\%$). Survival rates at 1 2, and 3 years were $67\%,\;33.3\%$ and $22.2\%$, respectively. Median survival was 17 months. There were 6 patients surviving more than 3 years. Distant metastasis occurred in 10 patients, with 8 in the lung only and 2 in both lung and bone, Toxicity included transient elevation of liver function test in all patients, fever in 20, thrombocytopenia in 4, and nausea and vomiting in 1. There was no treatment-related death. Conclusion : Combined TACE and RT appear to produce a favorable response and survival results with minimal toxicity.

  • PDF

Mixing Performance of Unlike Doublet Impinging Liquid Jets (이중 충돌제트의 혼합 성능 연구)

  • Jo, Yong Ho;Lee, Seong Ung;Yun, Ung Seop
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.82-91
    • /
    • 2003
  • Experiments to investigate the mixing performance of unlike doublet impinging jets are conducted. Reynolds number of simulants used in this study rages from 1.0 to 1.5 Cold flow test is performed to investigate the hydrodynamic effect and spray of the impinging jets are collected locally and calculated by using Rupe's mixing efficiency equation. Momentum exchanges and relative velocity ratio between two jets are taken as the main parameter to represent the effect of enlargement of the orifice diameter. As diameter ratio increases, the corresponding momentum ratio where maximum mixing efficiency occurs and relative velocity at the maximum mixing efficiency ranges 0.6 to 0.7, respectively. Penetration depth can be taken as a prominent parameter to estimate the mixing efficiency.