• Title/Summary/Keyword: 국소영역

Search Result 309, Processing Time 0.03 seconds

Effect of Improved Forelimb Sensorimotor Function on the Transcranial Direct Current Stimulation in a Focal Ischemic Brain Injury Rat Model (국소 허혈성 뇌손상 흰쥐 모델에서 경두개직류전기자극이 앞다리 운동감각 기능 증진에 미치는 효과)

  • Kim, Gi-Do;Sim, Ki-Cheol;Kim, Kyung-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.273-282
    • /
    • 2011
  • This study was to investigate the effect of improve forelimb sensorimotor function and neurotrophic factor(GAP-43) expression when differing an application time of tDCS in ischemic brain injury rat model(pre, $1^{st}$, $7^{th}$, $14^{th}$). Focal ischemic brain injury was induced in 80 Sprague-Dawley rats through middle cerebral artery occlusion(MCAO) by 'Longa' method. And then experimental groups were randomly divided into four groups; GroupI: MCAO induction, GroupII: application of tDCS(10 min) after MCAO induction, GroupIII: application of tDCS(20 min) after MCAO induction, GroupIV: application of tDCS(30 min) after MCAO induction. Modified limb placing test and single pellet reaching test were performed to test forelimb sensorimotor function. And the histological examination was also observed through the immunohistochemistric response of GAP-43(growth-associated protein-43) in the cerebral cortex. In modified limb placing test, groupIII(p<0.05) showed significantly improve than the other groups on $14^{th}$). day. In single pellet reaching test, groupIII(p<0.01) and groupIV(p<0.05) significantly improved on $14^{th}$) day. And in immunohistochemistric response of GAP-43, group III showed significantly positive response than the other groups on $14^{th}$ day. These results suggest that the intensity(0.1 mA)/time(20 min) condition of tDCS application has a significant impact on the sensorimotor functional recovery in focal ischemic brain injury rat models.

Metabolic impairment pattern analysis of the Alzheimer's disease (Alzheimer's Disease의 대사영상패턴 분석)

  • Juh, Ra-Hyeong;Lee, Chang-Uk;Chung, Yong-An;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.91-95
    • /
    • 2004
  • Several MRI studies have reported reductions in temporal lobe volumes in Alzheimer's disease (AD). Measures have been usually obtained with regions-of-interest (ROI) drawn manually on selected medial and lateral portions of the temporal lobes, with variable choices of anatomical borders across different studies. We used the automated voxel-based morphometry (VBM) approach to investigate gray matter abnormalities over the entire extension of the temporal lobe in 10AD patients (MM5E 22)and 22 healthy controls. Foci of significantly reduced gray matter volume in AD patients were detected in both medial and lateral temporal regions, most significantly in the right and left posterior parahippocarmpal gyri. At a more flexible statistical threshold (P<0.01, uncorrected for multiple comparisons), circumscribed foci of significant gray matter reduction were also detected in the right amygdala/enthorinal cortex, the anterior and posterior borders of the superior temporal gyrus bilaterally, and the anterior portion of the left middle temporal gyrus. These VBM results confirm previous findings of temporal lobe atrophic changes in AD, and suggest that these abnormalities may be confined to specific sites within that lobe, rather than showing a widespread distribution.

  • PDF

PRELIMINARY STUDY OF BRAIN SPECT IN CHILDREN WITH PERVASIVE DEVELOPMENTAL DISORDER OR DEVELOPMENTAL LANGUAGE DISORDER (전반적발달장애 아동 및 발달성언어장애 아동의 뇌 단일광자방출전산화단층촬영 소견에 대한 예비연구)

  • Shin, Yee-Jin;Ryu, Young-Hoon;Yook, Ki-Hwan;Noh, Kyung S;Song, Dong-Ho;Lee, Ho-Bun
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.256-265
    • /
    • 1997
  • Objectives:The purpose of this study was to investigate the characteristics and differences of brain function in pervasive developmental disorder and developmental language disorder. Method:The subjects were composed of 14 cases of pervasive developmental disorder and 13 cases developmental language disorder. They were investigated by technitium-99m-EDC SPECT. All SPECT were visually assessed by two nuclear medicine specialists, and then quantified by region of interest including temporal, parietal cortex, thalamus, basal ganglia and cerebellum. Result:In both groups, cerebral blood flow was decreased in the temporal, parietal cortex, basal ganglia, thalamus, cerebellum by visual assessment. There was no significant difference between the 2 groups by quantitative and qualitative assessment. Conclusion:These results suggest that pervasive developmental disorder and developmental language disorder are caused by defects in the interneural connection and that both disorders are spectrum disorders.

  • PDF

Evaluation of Clinical Usefulness of EIS(Electro Interstitial Scan) (EIS(Electro Interstitial Scan) 방법의 임상적 유효성 연구)

  • Kim, Soochan;Bae, Jang-Han;Jun, Min-Ho;Kim, Jaeuk U.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.124-133
    • /
    • 2015
  • Electro interstitial scan shows potential as a non-invasive screening method. It can discriminate some diseases based on electric current response to induce low intensity direct current to limbs or local area of body. DDFAO was invented in France and it is claimed that multi-channel EIS(Electro Interstitial Scan) is useful for various diseases, especially, diagnoses of endocrine system such as diabetics are very effective. In this study, we verified the repeatability and sensitivity of DDFAO by using a RC phantom model and its clinical usefulness using data obtained from normal and diabetes subject groups. As a result, it showed the repeatability and the output change according to change of phantom characteristic, but it was hard to distinguish normal and patient groups non-invasively with just six surface electrodes of DDFAO. The repeatability and the clinical accuracy was not sufficient for screening or diagnostic purposes, as well. In spite of the results with low repeatability and accuracy conducted in this study, we still need further investigations to improve the EIS-based measurement method; EIS is very convenient and simple and it shows potential as a screening tool of the whole body health conditions rather than localized disease diagnosis.

Time-series Mapping and Uncertainty Modeling of Environmental Variables: A Case Study of PM10 Concentration Mapping (시계열 환경변수 분포도 작성 및 불확실성 모델링: 미세먼지(PM10) 농도 분포도 작성 사례연구)

  • Park, No-Wook
    • Journal of the Korean earth science society
    • /
    • v.32 no.3
    • /
    • pp.249-264
    • /
    • 2011
  • A multi-Gaussian kriging approach extended to space-time domain is presented for uncertainty modeling as well as time-series mapping of environmental variables. Within a multi-Gaussian framework, normal score transformed environmental variables are first decomposed into deterministic trend and stochastic residual components. After local temporal trend models are constructed, the parameters of the models are estimated and interpolated in space. Space-time correlation structures of stationary residual components are quantified using a product-sum space-time variogram model. The ccdf is modeled at all grid locations using this space-time variogram model and space-time kriging. Finally, e-type estimates and conditional variances are computed from the ccdf models for spatial mapping and uncertainty analysis, respectively. The proposed approach is illustrated through a case of time-series Particulate Matter 10 ($PM_{10}$) concentration mapping in Incheon Metropolitan city using monthly $PM_{10}$ concentrations at 13 stations for 3 years. It is shown that the proposed approach would generate reliable time-series $PM_{10}$ concentration maps with less mean bias and better prediction capability, compared to conventional spatial-only ordinary kriging. It is also demonstrated that the conditional variances and the probability exceeding a certain thresholding value would be useful information sources for interpretation.

Stylized Specular Reflections Using Projective Textures based on Principal Curvature Analysis (주곡률 해석 기반의 투영 텍스처를 이용한 스타일 반사 효과)

  • Lee, Hwan-Jik;Choi, Jung-Ju
    • Journal of the HCI Society of Korea
    • /
    • v.1 no.1
    • /
    • pp.37-44
    • /
    • 2006
  • Specular reflections provide the visual feedback that describes the material type of an object, its local shape, and lighting environment. In photorealistic rendering, there have been a number of research available to render specular reflections effectively based on a local reflection model. In traditional cel animations and cartoons, specular reflections plays important role in representing artistic intentions for an object and its related environment reflections, so the shapes of highlights are quite stylistic. In this paper, we present a method to render and control stylized specular reflections using projective textures based on principal curvature analysis. Specifying a texture as a pattern of a highlight and projecting the texture on the specular region of a given 3D model, we can obtain a stylized representation of specular reflections. For a given polygonal model, a view point, and a light source, we first find the maximum specular intensity point, and then locate the texture projector along the line parallel to the normal vector and passing through the point. The orientation of the projector is determined by the principal directions at the point. Finally, the size of the projection frustum is determined by the principal curvatures corresponding to the principal directions. The proposed method can control the position, orientation, and size of the specular reflection efficiently by translating the projector along the principal directions, rotating the projector about the normal vector, and scaling the principal curvatures, respectively. The method is be applicable to real-time applications such as cartoon style 3D games. We implement the method by Microsoft DirectX 9.0c SDK and programmable vertex/pixel shaders on Nvidia GeForce FX 7800 graphics subsystems. According to our experimental results, we can render and control the stylized specular reflections for a 3D model of several ten thousands of triangles in real-time.

  • PDF

Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated Tc-99m-MIBI Myocardial SPECT (게이트 Tc-99m-MIBI SPECT에서 국소 심근운동과 수축기 심근두꺼워짐 자동정량화법의 재현성)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Cheon, Gi-Jeong;Kim, Yu-Kyeong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.487-496
    • /
    • 2000
  • Purpose: The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Materials and Methods: Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction $51{\pm}14%$) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using $AutoQUANT^{TM}$ software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Results: Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Conclusion: Segmental wall motion and systolic thickening quantified using $AutoeUANT^{TM}$ software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening.

  • PDF

Optical and Hydrophobic Properties of Ag Deposited ZnO Nanorods on ITO/PET (ITO/PET 기판 위에 성장된 산화아연 나노로드에 형성된 은 입자의 광학적 특성 및 소수성 표면 연구)

  • Ko, Yeong-Hwan;Kim, Myung-Sub;Yu, Jae-Su
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.4
    • /
    • pp.205-211
    • /
    • 2012
  • We investigated the optical and hydrophobic properties of the deposited silver (Ag) zinc oxide (ZnO) nanorods (NRs) on flexible indium tin oxide (ITO) coated polyethylene terephthalate (PET) substrates (i.e., ITO/PET). The ZnO NRs were grown by an electrochemical deposition using a sputtered ZnO seed layer and the Ag was deposited by using a thermal evaporator. For comparison, the same fabrication process was carried out on the bare ITO/PET without ZnO NRAs. Due to the discrete surface of ZnO NRs, the deposited Ag was formed as nano-scale particles, while the Ag became film-like for bare ITO/PET. In order to control the size and amount of Ag particles, the Ag deposition time was changed from 100 to 600 s. When the deposition time was increased, the Ag particles became larger and denser, and the absorptance was increased. This enhanced absorptance may be due to the localized surface plasmon resonance of Ag particles. Furthermore, the relatively high hydrophobicity was observed for the deposited Ag on the ZnO NRs/ITO/PET. These improved optical and surface properties are expected to be useful for flexible photovoltaic and optoelectronic devices.

Comparing Quantitative EEG and Low Resolution Electromagnetic Tomography Imaging between Deficit Syndrome and Non-Deficit Syndrome of Schizophrenia (정신분열병의 결핍증후군과 비결핍증후군에서 QEEG와 sLORETA를 이용한 비교연구)

  • Lee, Sang-Eun;Yim, Seon-Jin;Lee, Mi-Gyung;Lee, Jae-Won;Han, Kyu-Hee;Lee, Jong-Il;Sim, Min-Young;Yoon, Hai-Joo;Shin, Byoung-Hak
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 2010
  • Objectives: Deficit schizophrenia (DS) constitutes a disease separate from non-deficit schizophrenia (NDS). The aim of the current study was to compare the quantitative EEG and low resolution electromagnetic tomography (LORETA) imaging between DS and NDS. Methods: This study was performed by 32 channels EEG for 42 schizophrenia patients who we categorized into DS and NDS using proxy instrument deficit syndrome (PDS). We performed the absolute power spectral analyses for delta, theta, alpha, low beta and high beta activities. We compared power spectrum between two groups using Independent t-test. Partial correlation test was performed with clinical parameters. Standardized LORETA (sLORETA) was used for comparison of cortical activity, and statistical nonparametric mapping (SnPM) was applied for the statistical analysis. Results: DS showed significantly increased delta and theta absolute power in fontal and parietal region compared with NDS (p<0.05). Power spectrum showed significant correlation with 'anergia' and 'hostility/suspiciousness' subscale of brief psychiatric rating scale (BPRS)(p<0.05). sLORETA found out the source region (anterior cingulate cortex/limbic part) that delta activity was significantly increased in DS (p=0.042). Conclusions: DS showed different cortical activity compared with NDS. Our results may suggest QEEG and LORETA could be the marker in differentiating between DS and NDS.

  • PDF

Classification of a Volumetric MRI Using Gibbs Distributions and a Line Model (깁스분포와 라인모델을 이용한 3차원 자기공명영상의 분류)

  • Junchul Chun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.58-66
    • /
    • 1998
  • Purpose : This paper introduces a new three dimensional magnetic Resonance Image classification which is based on Mar kov Random Field-Gibbs Random Field with a line model. Material and Methods : The performance of the Gibbs Classifier over a statistically heterogeneous image can be improved if the local stationary regions in the image are disassociated from each other through the mechanism of the interaction parameters defined at the local neighborhood level. This usually involves the construction of a line model for the image. In this paper we construct a line model for multisignature images based on the differential of the image which can provide an a priori estimate of the unobservable line field, which may lie in regions with significantly different statistics. the line model estimated from the original image data can in turn be used to alter the values of the interaction parameters of the Gibbs Classifier. Results : MRF-Gibbs classifier for volumetric MR images is developed under the condition that the domain of the image classification is $E^{3}$ space rather thatn the conventional $E^{2}$ space. Compared to context free classification, MRF-Gibbs classifier performed better in homogeneous and along boundaries since contextual information is used during the classification. Conclusion : We construct a line model for multisignature, multidimensional image and derive the interaction parameter for determining the energy function of MRF-Gibbs classifier.

  • PDF