• Title/Summary/Keyword: 구조 벽체

Search Result 587, Processing Time 0.029 seconds

Seismic Performance of Precast Infill Walls with Strain-Hardening Cement Composite (변형경화형 시멘트 복합체를 사용한 프리캐스트 끼움벽판의 내진성능)

  • Kim, Sun-Woo;Jeon, Esther;Kim, Yun-Su;Ji, Sang-Kyu;Jang, Gwang-Soo;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.89-92
    • /
    • 2008
  • The seismic behavior of the lightly reinforced concrete frames (LRCFs) was controlled by the nonductile behavior of the critical regions. These critical regions require retrofit to improve the seismic behavior of the lightly reinforced concrete frames. Critical column end regions must be retrofit to increase the global ductility capacity. The objective of this research is to evaluate structural strengthening performance of lightly reinforced concrete frame with Strain hardening cement composite(SHCC) experimentally. The experimental investigation consisted of a cyclic load tests on 1/3-scale models of precast infill walls. Reinforcement detail of infill wall was variables in the experiment. The experimental results, as expected, show that the multiple crack pattern, strength, ductility and energy dissipation capacity are superior for specimen with SHCC infill wall due to bridging of fibers and stress redistribution in cement matrix.

  • PDF

Economic Evaluation on Geosynthetic Reinforced Abutment for Railways (특정형상의 인공자갈이 혼합된 도상자갈층의 지지성능과 응력전달특성)

  • Kim, Dae Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.15-20
    • /
    • 2019
  • This paper evaluated the construction costs of 11 design cases to decrease the horizontal forces applied to the abutment. They include two abutment types, which are to improve backfill materials for a reversed T-shaped abutment and geosynthetic Reinforced Abutment for Railways (RAR). The first type of economic analysis was that the internal friction angles of backfill materials were increased from Φ=35° to Φ=40° and 50° for a reversed T-shaped abutment. In addition, the second type was the cases with the design of geosynthetic RAR. When friction angles of 40° or 50° were applied through the improvement of the backfill material, the decrease in construction cost of the abutment was not large (2.0~3.9%), even though the horizontal forces applied to the abutment had decreased to 18~48%. In the case of applying the RAR, however, a maximum 30% cost reduction was evaluated by the decrease in horizontal force to "0" theoretically. The cost reduction resulted from the decrease in wall thickness, base slab size, and number and material change of pile foundation for the abutment.

Cyclic Behavior of Slender Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement (묶음 대각철근을 갖는 세장한 철근콘크리트 연결보의 이력거동)

  • Han, Sang-Whan;Yoo, Kyoung-Hwan;Lee, Ki-Hak;Shin, Myoung-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.6
    • /
    • pp.661-668
    • /
    • 2015
  • Coupled shear walls are effective lateral force resisting system in which coupling beams link individual walls. For improving the energy dissipation capacity of coupling beams, diagonal reinforcement details were developed. However, it is difficult to construct diagonal reinforced coupling beams due to the congestion of reinforcement in the beam. For resolving the problem, this study developed precast coupling beams with bundled diagonal reinforcement. To reduce the reinforcement congestion, bundled diagonal reinforcement were placed in the coupling beam. To evaluate the cyclic performance of coupling beams with bundled diagonal reinforcement, experimental test were conducted. For this purpose, two slender specimens with an aspect ratio of 3.5 were made and tested. It was observed that the cyclic performance of the coupling beam with bundled diagonal reinforcement was similar with that of the coupling beam with normal diagonal reinforcement placed according to design code to ACI 318-11.

Structural Performance of Beam-Middle Column Connection of 12m × 3m Steel Modular System (12m × 3m 스틸 모듈러 시스템의 보-중간기둥 접합부 구조성능)

  • Shim, Sung Chul;Lee, Sang Hyun;Jo, Bong Ho;Woo, Sung Sik;Choi, Mun Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.6
    • /
    • pp.793-805
    • /
    • 2008
  • Recently, steel modular systems are developed and have been applied to the projects requiring fast construction such as military barracks and vertical expansion of school buildings. The existing modular system with standard module of ${6m\times3m}$ has a problem that many columns are duplicated in the module connection and the wall thickness increases. In this study, $12m{\times}3m$ module is proposed to solve this problem. Various types of beam-middle column connection which are essential for realizing the $12m{\times}3m$ module are proposed and their maximum load capacity and failure mode are analytically and experimentally evaluated. The comparison between analytical and experimental results shows that the maximum axial load and failure mode can be accurately estimated by finite element analysis. Some connection types which have higher failure load than the design load of the column, can be used as the beam-middle column connection detail of the $12m{\times}3m$ module.

Development of Nano Ceramic Structures for HEPA Type Breathing Wall (HEPA Filter형 숨쉬는 벽체용 나노세라믹 여재개발)

  • Kim, Jong-Won;Ahn, Young-Chull;Kim, Gil-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.274-279
    • /
    • 2008
  • In the perspective of saving energy in buildings, high performance of insulation and air tightness for improving the heating and the cooling efficiency has brought the positive effect in an economical view. However, these building energy saving technologies cause the lack of ventilation, which is the direct cause of increasing the indoor contaminants, and it is also very harmful to residents because they spend over 90% of their time in the indoor area. Therefore, the ventilation is important to keep indoor environment clean and it can also save energy consumption. In this study, a HEPA type breathing wall is designed as a passive ventilation system to collect airborne particles and to supply fresh outdoor air. To make fine porous structures, polymer nano fibers which were made by electro spinning method are used as a precursor. The nano fibers are coated with SiO2 nano particles and finally the HEPA type breathing wall is made by sintering in the electric furnace at $300\sim500^{\circ}C$. The pressure drops of nano ceramic structure are 8.2, 25.5 and 44.9 mmAq at the face velocity of 2.0, 5.9 and 8.8 cm/s, respectively. Also the water vapor permeability is $3.6g/m^2{\cdot}h{\cdot}mmHg$. In this research, the porous nano ceramic structures are obtained and the possibility for the usage of a material for HEPA type breathing wall can be obtained.

The Experimental Study for Radiant Heat Flux of Non-insulated Glazed Window in Fire (화재시 비차열 유리의 복사열에 관한 실험적 연구)

  • Park, Soo-Young;Seo, Hee-Won;Kim, Dae-Hoi;Wang, Nam-Woong;Yeo, In-Hwan;Choi, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.26-33
    • /
    • 2014
  • Recently in Korea, the interest for using window and window-wall in building picks up due to the beauty and utilization of space. But, interior space of the buildings shall be compartmentalized by fire resistance structures in accordance with the Korean building codes to prevent the spread of flame and damage of human life in fire. In case of installing non-insulated glazed window in compartment wall, the flame spread to adjacent space and the damage of human life by radiant heat can occur in fire. On this study, to confirm the risk of radiant heat for non-insulated glazed window in fire, the fire resistance tests were conducted. The temperature rise and heat flux on unexposed space was measured and analyzed.

ZnO/Ag/ZnO Thin Films With Different Metal Layer Thickness (Metal Layer의 두께 변화에 따른 ZnO/Ag/ZnO 다층 박막의 특성 연구 Properties of Multi Layer)

  • Lee, Seung-Min;Lee, Sang-Ryeol;Kim, Hong-Bae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.352-352
    • /
    • 2013
  • 국내 에너지 소비량의 21.6%가 건물 분야에 소비되고 있다. 창호는 벽체에 비해 8~10배 이상 낮은 단열 특성을 가지기 때문에 열 손실량이 크다. 유리는 창호를 이루는 요소 중 가장 큰 면적을 차지하고 있으며, 창호의 단열성능을 2배로 향상시키면 30% 이상 건물의 에너지 절감 효과를 가질 수 있다. 창호의 단열 성능을 향상시키기 위해서 Low-e(emissivity) 기술 연구가 진행 중이다. 이번 실험에서는 RF 마그네트론 스퍼터링 시스템을 사용하여 XG 유리기판 위에 ZnO박막을 증착하고, evaporator 장비를 사용하여 metal층인 Ag를 증착하였다. 그리고 다시 한번 ZnO박막을 증착하였다. Low-e 연구에 활용할 수 있는지를 확인하기 위해 XRD, AFM, 투과도를 측정하였다. ZnO박막의 증착 조건은 초기압력 $3.0{\times}10^{-6}$ Torr, 공정압력 $2.0{\times}10^{-2}$ Torr, RF파워 30 W, Ar gas는 50 sccm, 증착온도는 상온으로 하였다. Metal층인 Ag를 증착하기 위해 evaporator의 증착 조건은 Rotate rate 2 rpm, voltage 0.3V, 공정압력 $5.0{\times}10^{-6}$ Torr이며, 변수로 Ag두께를 3,5,7,9,11,13,15 nm로 하였다. AFM 측정결과 Ag두께가 증가할수록 RMS roughness값이 높아졌으며, 최소 0.71 nm의 거칠기를 가지는 것을 확인하였다. XRD분석결과 37도 부근의 피크가 발생하여 ZnO 박막이 결정질 구조임을 확인할 수 있었다. 그리고 UV-Visible-NIR 분광 광도계를 이용하여 광학적 투과를 측정한 결과 Ag두께가 13 nm일 때 가시광 영역의 투과도가 최대 75%, 적외선 영역의 투과도가 최소 28%로 좋은 차단 특성을 가지는 것을 확인하였다. 위 결과들로 ZnO 박막이 Low-e 기술에 활용될 수 있음을 확인하였다.

  • PDF

Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots (국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사)

  • Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.496-503
    • /
    • 2016
  • This paper studies the leakage situation of domestic residential building underground parking lots and main leakage areas. 18 complexes were studied and the results showed that 80% of buildings with exterior waterproofing had no leakage, but all buildings with interior waterproofing had leakage. According to a survey among professionals, water leakage problems are considered to be severe in underground parking lots and a preventative measure is required by the government. By comparing the survey and the actual situation at hand, the results showed that the lowest floor slab, wall construction joints, and floor expansion joints were the most prone to leakage. Based on the results, further study to develop a design manual for the appropriate prevention of leakage is deemed necessary.

Variations of Coefficient of Earth Pressure at Rest According to Stress Paths for Compacted Residual Soils (다짐 화강풍화토의 응력이력에 따른 정지상태 토압계수의 변화)

  • Lee Byung-Sik;Park Sung-Kook
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.8
    • /
    • pp.85-93
    • /
    • 2005
  • Earth pressures acting on unmovable rigid walls vary according to loading-unloading conditions due to compaction experienced by backfill soil. Appropriate coefficients of earth pressure at rest with considering this influence need to be determined to estimate earth pressures more reasonably.0 this study, a single cycle hysteretic model simulating soil's loading-unloading-reloading behavior under $K_o-condition$ was reproduced by conducting a series of $K_o-triaxial$ test for compacted residual soils. Based on the results, coefficients of earth pressure at rest at each stage of stress paths such as, virgin loading, unloading and reloading were determined. Also, applicabilities of empirical equations to the estimation of the coefficients were evaluated by comparing the experimental results with those estimated by the equations. As a result, it was concluded that the empirical equations could be applied reasonably to the estimation of the coefficients for compacted residual soils in cases where some amount of error might be acceptable for the reloading stage of the hysteretic model.

A Study on the Behavior of the Retaining Walls with the Improved Top-Down Support System using the Building Structure (건축 구조체를 이용한 개량 역타공법 적용시 흙막이 벽체의 거동 연구)

  • Chun, Byung-Sik;Roh, Bae-Young;Do, Jong-Nam;Rew, Woo-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1666-1672
    • /
    • 2008
  • In this study, it collected and analyzed a construction case of the improved top-down support system application field on a case by case retaining wall method. The behavior of horizontal displacement was analyzed according to retaining wall type after reviewing a design stage and estimated horizontal displacement under the construction. The study results showed that it is judged stable until excavation termination irrelevant to a retaining wall method at the improved top-down support system application. It is judged that the settlement of behind ground can minimize because the retaining wall head displacement also behave stably. It was compared the predicted horizontal displacement in design and the measured horizontal displacement acquired through a measurement by using Elasto-Plastic analysis program. The comparison results showed that a similar horizontal displacement was predicted within stability standard irrelevant to a retaining wall method. So, it is decided that the advanced prediction is reasonable by Elasto-Plastic analysis in design applied the improved top-down support system. In the case of the ground anchor method application under a same condition, it is decided that a horizontal displacement will more increase than the improved top-down support system is applied. If a section condition is same, it was decided that to apply top-down support system is more stable than that.

  • PDF