• Title/Summary/Keyword: 구조성능

Search Result 14,869, Processing Time 0.036 seconds

Seismic Capacity Evaluation of Bridge Structure using Capacity Spectrum Method (역량스펙트럼법에 의한 교량 구조물의 내진성능평가)

  • 박연수;오백만;박철웅;서병철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.5
    • /
    • pp.67-73
    • /
    • 2003
  • The present seismic analysis of Road-Bridge Design Standard is on a basis of load-based analysis which lets structures have the strength over load. In this study, the capacity spectrum method, a kind of displacement based method, which is evaluated by displacement of structure, is presented as an alternative to the analysis method based on load. Seismic capacity is performed about the existing reinforced concrete pier which has already secured seismic design by capacity spectrum method. As a result. capacity spectrum method could realistically evaluate the non-elastic behavior of structures easily and quickly and the displacement of structures for variable ground motion level. And it could efficiently apply to an evaluation of seismic capacity about the existing structure and a verification of design for capacity target of the new structure.

Experimental Study on the Active Controller of Structures Considering Modeling Uncertainty (구조물의 모델링 불확실성을 고려한 능동 제어기의 실험연구)

  • 민경원;김성춘
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.53-61
    • /
    • 2000
  • 능동 제어기를 설계하기 위해서는 제어대상 구조물의 수학모델의 구해야한다. 그러나, 무한차원의 구조물에 대하여 정확한 모델을 구하는 것은 불가능하므로 유한차원인 저차원화된 모델을 사용하여 제어기를 설계한다. 그러나, 실제 구조물과 저차원화된 모델사이의 오차에 의하여 제어기의 성능이 저하가 되면 제어기와 구조물의 상호작용, 지진과 같은 오란 등의 불확실성, 지진시 구조물의 동적 특성 변화로 인하여 제어기의 성능이 더욱 저하가 된다. 이러한 저하 요인은 제어기 설계시 요구되는 구조물의 수학모델에 대한 불확실한 요소로 작용하기 때문에 제어성능의 저하를 일으키며 응답의 불안정을 유발하기로 한다. 본 연구에서는 질량형 능동제어기(AMD)가 설치된 3층 건물 모형의 모델 오차에 관한 불확실성을 반영한 강인제어기법을 적용하여 제어성능과 안정성을 실험을 통하여 분석하였다. 강인제어 기법인 $\mu$ 합성법에 요구되는 여러 가지 가중함수인 주파수필터는 건물과 AMD의 특성, 모델 오차, 제어율과 AMD 성능의 , 측정잡음 및 지진외란의 특성 등을 고려하여 정량적으로 선택되었다. $\mu$합성법에 의하여 제어기를 설계하였으며 강인성을 비교하기 위하여 불확실성이 고려되지 않는 LQG 기법에 의한 제어기를 선택하였다. $\mu$합성법은 규정된 불확성에 대하여 제어의 강인성을 가지므로 동적특성이 바뀐 건물모형에 관한 강인성을 LQG 기법에 의한 제어성능과 비교하였다. 그 결과 동적특성이 변화된 건물에 대하여 $\mu$합성법만이 제어의 효율성이 유지되는 강인성을 나타내었다.

  • PDF

Structural Performance of Mortar-filled Sleeve Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading (반복하중을 받는 SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음의 구조성능)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.6
    • /
    • pp.180-192
    • /
    • 2008
  • The purpose of this research is to evaluate the structural performance of mortar-filled ductile cast iron sleeve splice developed for SD500 high-strength reinforcing bar under cyclic loading. The test variables adopted in this study are the development length of bar, compressive strength of mortar, bar size, sleeve types and others. In this research, it is showed that the mortar-filled sleeve splice for SD500 high-strength bar satisfied the structural performance required in ACI, AIJ code as well as domestic code. Also the results of experimental research presented in this paper provided basic engineering data for developing a reasonable design method of mortar-filled sleeve splice for SD500 high-strength reinforcing bar.

Fatigue Capacity Evaluation of Hinge Type Connection System for a Hybrid Truss Bridge (복합 트러스교 힌지형 격점 구조의 피로 성능 평가)

  • Jung, Kwang-Hoe;Yi, Jong-Won;Lee, Sang-Hyu;Kim, Jay Jang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.303-310
    • /
    • 2011
  • To replace a steel box bridge for constructions of medium span bridges in Korea, the Hybrid Truss Bridge (HTB) is being considered as an alternative bridge type. The core technology of HTB is the connection joint that links the concrete slabs and steel truss pipes. Various construction companies in Japan have developed unique connection systems and applied to the real bridge constructions after verifying their performances through the experimental evaluation. In this study, the fatigue test of a hybrid truss girder has been performed in order to verify the newly proposed hinge type connection joint`s static and fatigue capacities. Through this fatigue test results, it is founded that the structural detail to improve the fatigue capacity should be developed. The hinge connection system with circular ribs has been proposed by means of structural finite element analyses. And then the fatigue test for this connection joint has been performed and it is proved that this connection joint has enough fatigue capacity. Finally, it is expected that the hinge connection system with circular ribs developed by in this study can be easily applied to the real bridge.

The Study of Protein Structure Visualization and Rendering Speed Using the Geometry Instancing (기하 인스턴싱 기법을 이용한 단백질 구조 가시화 및 속도 향상에 관한 연구)

  • Park, Chan-Yong;Hwang, Chi-Jung
    • The KIPS Transactions:PartA
    • /
    • v.16A no.3
    • /
    • pp.153-158
    • /
    • 2009
  • Analysis of 3-dimensional (3D) protein structure plays an important role of structural bioinformatics. The protein structure visualization is the one of the structural bioinformatics and the most fundamental problem. As the number of known protein structure increases rapidly and the study of protein-protein interaction is prevalent, the fast visualization of large scale protein structure becomes essential. The fast protein structure visualization system we proposed is sophisticated and well designed visualization system using geometry instancing technique. Because this system is optimized for recent 3D graphics hardware using geometry instancing technique, its rendering speed is faster than other visualization tools.

Seismic Capacity Evaluation of Existing Structures Incorporating Damage Assessment (구조손상을 고려한 기설구조물의 내진성능평가)

  • Song, Jong Keol;Yi, Jin Hak;Lee, Dong Guen
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.543-553
    • /
    • 2004
  • This paper covered two related subjects: the use of the inverse modal perturbation technique to assess structural damage in existing structures; and the use of a seismic capacity evaluation to assess damaged structures, with the aid of the identified structural damage. The substructural identification and the Tikhonov regularization algorithm were incorporated for efficient damage assessment of complex and large frame structures. The seismic capacity of a damaged structure was evaluated by comparing the structure's seismic responses and seismic damage indices. The effectiveness of the proposed method has been investigated through the numerical simulation study for a twenty-story frame structure with undamaged and damaged cases, and also different earthquake excitations.

Performance Evaluation of Softwood Plywood as Structural and Concrete-Form Panels (침엽수 합판의 구조용 및 콘크리트 거푸집용으로서의 성능 평가)

  • Lee, Jun-Jae;Kim, Gwang-Chul;Lee, Guk-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.14-24
    • /
    • 2000
  • In present research, the plywoods made of radiata pine or Japanese larch, the potential softwood species in mass supply, were discussed to examine their feasibility as the structural and concrete form panels through the basic properties test. First, plywood qualities and its nail performance were tested. The performance test for concrete form or structural panel by concentrated and uniformly distributed load were conducted to investigate the possibility as structural material for light frame and concrete constructions. Test results of basic quality such as specific gravity, cupping, bowing, and twisting appeared to satisfy the criteria for structural use. Also, nail performance test results, for roof and wall sheathing panels, nail lateral resistance, nail withdrawal resistance, and nail push head resistance proved to meet the required standard for structural use. The test results on performance as structural panel by concentrated and uniformly distributed load and as concrete form panel showed that these two species could be used for structural sheathing, subfloor, and concrete form panels.

  • PDF

Relation Extraction based on Neural-Symbolic Structure (뉴럴-심볼릭 구조 기반의 관계 추출)

  • Oh, Jinyoung;Cha, Jeong-Won
    • Annual Conference on Human and Language Technology
    • /
    • 2020.10a
    • /
    • pp.115-118
    • /
    • 2020
  • 딥러닝은 자연어처리 분야에서 우수한 성능을 보이고 있다. 하지만 우수한 성능을 달성하려면 많은 학습 데이터와 오랜 학습 시간이 필요하다. 우리는 딥러닝과 기호 규칙을 함께 사용하는 뉴럴-심볼릭 방법을 이용하여 딥러닝만으로 학습한 모델의 성능을 능가하는 방법을 제안한다. 딥러닝의 한계를 극복하기 위해서 관계추출에서 규칙 결과와 딥러닝 결과와의 불일치도를 추가한 구조를 설계하였다. 제안한 구조는 한국어 데이터에 대해서 우수한 성능을 보였으며, 빠른 성능 수렴이 이루어지는 것을 확인하였다.

  • PDF

The Preliminary Seismic Performance Evaluation of Cut-and-Cover Tunnels through the Case Studies (적용사례 분석을 통한 개착식 구조물의 내진성능 예비평가)

  • Park, Beom-Ho;Tian, Minnu;Lee, Tae-Hyung;Kim, Kee-Dong;Lim, Nam-Hyoung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05b
    • /
    • pp.653-656
    • /
    • 2010
  • 개착식 구조물의 내진성능 예비평가는 설계자료나 현장조사를 토대로 지진도 그룹, 취약도 지수, 영향도 지수를 산정하여 내진성능 상세평가의 시행여부를 판단하는 근거가 되어왔다. 내진성능 예비평가를 적용했던 사례를 분석한 결과 평가항목 산정 시 근거가 미약하고, 내진성능 상세평가 대상으로 분류되지 않은 그룹에 대해 구조적 내진성능 확보가 불확실하여 내진성능 예비평가를 개정하였다. 개정한 내진성능 예비평가는 지진도 그룹, 취약도 지수, 영향도 지수를 적용하는 기존의 틀은 유지하면서 평가항목을 산정하는 근거를 명확하게 하였으며, 내진성능 상세평가를 실시하지 않는 그룹에 대해서도 간략하게 구조적 내진성능 확보여부를 검토할 수 있는 전단변형각을 도입하였다. 본 연구에서는 개정한 내진성능 예비평가를 기존 사례에 적용하여 결과를 도출하였으며, 기존의 적용 사례와 비교 분석하였다.

  • PDF

The Structural Performance of PSC Frame System with GerberCs beam (게르버 보 형식의 PSC 골조시스템의 구조성능)

  • Kim, Sang-Sik;Choi, Kwang-Ho;Lee, Jong-Gyu;Song, Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.341-346
    • /
    • 2002
  • 이 연구는 게르버 보 형식의 포스트텐션 PC 골조 구조 시스템의 실용화를 위해 골조 전체의 구조 성능 시험을 수행하며, 여기서 보-기둥 접합부 및 내민 보-단순 보 접합부의 구조 성능과 골조의 안전성을 확인한다. 시험은 400 mm$\times$800 mm 단면의 경간 3 m 보와 500 mm$\times$600 mm 단면을 갖는 높이 3 m 기둥의 실물 크기 시험체를 제작하여, 기둥에 80 톤의 축 하중을 준 상태에서 단순 보 중앙에 하중을 가력하여 기둥-보 접합부와 단순 보-내민 보 단면 축소 연결부의 구조성능을 파악한다. 시험 결과, 보 - 기둥 접합부는 예상 설계 하중 40톤 이상에서도 강 접합에 가깝게 거동하였고, 단순 보- 내민 보의 단면 축소 연결부는 경사철근의 사용으로 초기 균열 및 균열 확산에 대한 억제 효과가 있었으며, 예상 설계 전단력 40톤에서 안전하다는 것이 확인되었다.

  • PDF