• Title/Summary/Keyword: 구조물-지반 상호거동

Search Result 146, Processing Time 0.027 seconds

Earthquake Response Analysis of an Offshore Wind Turbine Considering Fluid-Structure-Soil Interaction (유체-구조물-지반 상호작용을 고려한 해상풍력발전기의 지진응답해석)

  • Lee, Jin-Ho;Lee, Sang-Bong;Kim, Jae-Kwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.1-12
    • /
    • 2012
  • In this study, an analysis method for the earthquake response of an offshore wind turbine model is developed, considering the effects of the fluid-structure-soil interaction. The turbine is modeled as a tower with a lumped mass at the top of it. The tower is idealized as a tubular cantilever founded on flexible seabed. Substructure and Rayleigh-Ritz methods are used to derive the governing equation of a coupled structure-fluid-soil system incorporating interactions between the tower and sea water and between the foundation and the flexible seabed. The sea water is assumed to be a compressible but non-viscous ideal fluid. The impedance functions of a rigid footing in water-saturated soil strata are obtained from the Thin-Layer Method (TLM) and combined with the superstructure model. The developed method is applied to the earthquake response analysis of an offshore wind turbine model. The method is verified by comparing the results with reference solutions. The effects of several factors, such as the flexibility of the tower, the depth of the sea water, and the stiffness of the soil, are examined and discussed. The relative significance of the fluid-structure interaction over the soil-structure interaction is evaluated and vice versa.

Analysis of Dynamic Behavior of Group Piles in Asymmetric Ground (비대칭지반에 설치된 무리말뚝의 동적거동 분석)

  • Kyungil Cho;Hongsig Kang;Kusic Jeong;Kwangkuk Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.41-49
    • /
    • 2023
  • Structures such as bridge columns installed on the asymmetric ground such as mountain areas and sloping ground are subject to various loads such as wind, temperature, earthquake, and etc. The pile foundation is generally applied to bridge columns on the asymmetric ground in order to stably support structures. The behavior of the pile foundation supporting bridge columns changes due to various load conditions. In particular, ground-pile-structure interactions should be studied to analyze the behavior of the pile foundation that supports bridge columns effected by dynamic loads such as earthquakes. The pile foundation installed on the asymmetric ground effected by the earthquake has the complicated dynamic interaction between the foundation and the ground due to the ground slope, the difference in soil resistance according to the shaking direction, and the ground movements. In this study, the 1g shaking table tests were conducted to confirm the effect of the slope of the sloping ground on the dynamic behavior of group piles supporting the superstructure installed at the berm of the sloping sandy soil which is the asymmetric ground. The result shows that the acceleration of the pile cap and the superstructure decrease as the slope of the sloping ground increase, and the slope of the dynamic p-y curve of the pile decrease.

A Probabilistic Analysis of Soil-Structure Interaction Using Infinite Elements (무한요소를 이용한 지반 구조물 상호작용의 확률론적 해석)

  • 이인모;노한성
    • Geotechnical Engineering
    • /
    • v.5 no.2
    • /
    • pp.33-44
    • /
    • 1989
  • In this paper, uncertainties in dynamic soil structure interaction (SSI) of nuclear poi.or plants subjected to seismic loading are studied considering the random characteristics of soils surround- ing the structure. Firstly sensitivity analysis is performed to study the effect of uncertain dynamic soil properties on the response of the structure. Secondly, to take into account the non-neterministic characteristics in analysis caused by random characteristics of the soil properties, Perturbation method and Rosenblueth's Two point estimates were used for this studu. The procedure is based on the comptex response method which is constituted by a combined usage of conventional finite elements for the near field and infinite elements for the far field. Results of the sensitivity analysis show that dynamic soil properties greatly affect the response of the sol.uc- lure. Results of the probabilistic analysis show that the Two-point estimate method produces good agreements with the Perturbation method.

  • PDF

A Simplified Soil-Structure Interaction Analytical Technique of Embedded Structure and Structure on Layered Soil Sites (매입구조물(埋入構造物)과 층상지반상(層狀地盤上) 구조물(構造物)에 대한 지반(地盤)-구조물(構造物) 상호(相互) 작용(作用)의 단순해석(單純解析))

  • Joe, Yang Hee;Lee, Yong Il;Kim, Jong Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.45-57
    • /
    • 1987
  • The dynamic behavior of a structure by earthquake is considerably affected by the flexibility of the base soil. This phenomenon is called dynamic soil-structure interaction effect. There are two broad categories of soil-structure interaction analytical technique: direct method and substructure method. Substructure method, in contrast to direct method, has many limitations in applying to embedded structures or structures on layered soil sites, while it is relatively simple. In this paper, a simplified soil-structure interaction analytical procedure using substructure method is proposed to eliminate its original limitations. The proposed method is well applicable to embedded structures or structures on layered soil sites with as good results as FLUSH.

  • PDF

Numerical Simulation on the Shaking Table Test considering Soil Structure Interaction (구조물과 지반의 동적 상호작용을 고려한 진동대 시험에 관한 수치 시뮬레이션)

  • Lee, Sung-Kyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.21-28
    • /
    • 2005
  • This paper proposes a shaking table test considering the dynamic soil strcuture interaction (SSI) by using the accelerations measured from superstructure and shaking table. The proposed method based on the substructure method is that only superstructure is used as an experimental model and dynamic soil stiffness is reflected on the controller of shaking table for soil model. At the moment, an experimental superstructure is excited by a shaking table with the motion required to emulate the dynamic behavior of total SSI system. First, the validity of the proposed method is verified by the verification model of numerical simulation, which is derived from the equation of motion of SSI system under consideration. Also, the applicability of the proposed method to shaking table test is numerically verified from the simulation model incorporating the transfer function of shaking table.

Behaviour of a Single Pile in Heaving Ground Due to Ground Excavation (지하터파기로 인해 융기(Heaving)가 발생한 지반에 근입된 단독말뚝의 거동)

  • Lee, Cheolju
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.1
    • /
    • pp.27-34
    • /
    • 2010
  • A finite element analysis has been conducted to clarify the behaviour of a single pile in heaving ground related to ground excavation. The numerical analysis has included soil slip at the pile-soil interface, analysing the interaction between the pile and the clay has been studied. The study includes the upward movement of the pile, the relative shear displacement between the pile and the soil and the shear stresses at the interface and the axial force on the pile. In particular, the shear stress transfer mechanism at the pile-soil interface related to a decrease in the vertical soil stress has been rigorously analysed. Due to the reductions in the vertical soil stress after excavation, the relative shear displacement and the shear stress along the pile have been changed. Upward shear stress developed at most part of the pile (Z/L=0.0-0.8), while downward shear stress is mobilized near the pile tip (Z/L=0.8-1.0) resulting in tensile force on the pile, where Z is the pile location and L is the pile length. Some insights into the pile behaviour in heaving ground analysed from the numerical analyses has been reported.

Dynamic Behavior Characteristics of Group Piles with Relative Density in Sandy Soil (건조 모래지반의 상대밀도에 따른 무리말뚝의 동적거동특성)

  • Heungtae Kim;Hongsig Kang;Kusik Jeong;Kwangkuk Ahn
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.9
    • /
    • pp.33-40
    • /
    • 2023
  • The lateral load which is applied to the pile foundation supporting the superstructure during an earthquake is divided into the inertia force of the upper structure and the kinematic force of the ground. The inertia force and the kinematic force could cause failure to the pile foundation through different complex mechanisms. So it is necessary to predict and evaluate interaction of the ground-pile-structure properly for the seismic design of the foundation. The interaction is affected by the lateral behavior of the structure, the length of the pile, the boundary conditions of the head, and the relative density of the ground. Confining pressure and ground stiffness change accordingly when the relative density changes, and it results that the coefficient of subgrade reaction varies depending on each system. Horizontal bearing behavior and capacity of the pile foundation vary depending on lateral load condition and relative density of the sandy soil. Therefore, the 1g shaking table tests were conducted to confirm the effect of the relative density of the dried sandy soil to dynamic behavior of the group pile supporting the superstructure. The result shows that, as the relative density increases, maximum acceleration of the superstructure and the pile cap increases and decreases respectively, and the slope of the p-y curve of the pile decreases.

Development of an Infinite Element for Non-linear Dynamic Analysis of Structures (구조물의 비선형 동적 해석을 위한 무한요소의 개발)

  • Kwon, Min-Ho;Han, Gil-Woong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1053-1058
    • /
    • 2010
  • Infinite element approach has been widely used to analysis soil-structure interaction, in which the soil domain is treated as infinite domain. However, most of the developed infinite element has been formulated in the frequency domain rather than the time domain to include the frequency contents of the earthquake or vibration wave. Due to that, those approaches have a critical limitation which is restricted to the linear elastic analysis. To main objective of this research is to develop the infinite element in the time domain to cooperate the inelastic soil and structure behavior. Developed infinite element is verified with the results of finite element analysis modeled in large domain. The nonlinear analysis also conducted to demonstrate the application of developed infinite element. Hence, based on above-mentioned statements, it can be concluded that the propose approach would assist for structure-seismic design.

INELASTIC RESPONSE SPECTRA CONSIDERING THE NONLINEARITY OF THE SOFT SOIL DUE TO THE WEAK SEISMIC EXCITATIONS (약진에 의한 연약지반의 비선형성을 고려한 비탄성 응답스펙트럼)

  • Kim, Yong-Seok
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.249-258
    • /
    • 2003
  • 강진을 고려한 지진설계 규준은 약진지역에서는 불필요한 경제적 손실을 가져올 수 있고, 지반-구조물 상호작용을 고려한 성능기준 설계가 합리적인 지진설계를 위해서 중요하다는 것이 인식되었다. 이 연구에서는 연약지반 위에 놓인 단자유도계의 탄성, 비탄성 지진응답 해석을 지반의 비선형성을 고려하여 최대지진가속도를 0.07g와 0.11g로 조정한 11개 중, 약진에 대해 수행하였다. 지진 응답해석은 지반-구조물체계에 대해 유사 3차원 동적해석 프로그램으로 암반에 지진기록을 입력하여 한 단계에 일괄적으로 수행하였다. 연구 결과에 의하면 고정지반이나 선형지반을 가정한 지진응답 스펙트럼은 구조물-지반체계의 실제적인 거동을 보여주지 못하는 것으로 나타났으며, 합리적인 지진설계를 위해서는 지진규준에 정해진 일상적인 설계절차에 따라서 수행하는 것보다 다른 성질을 가진 여러 지반에 대해서 성능기준 지진설계를 수행하는 것이 필요하다. 약진을 받는 연약지반의 비선형성도 입력지진동을 증폭시켜 탄성, 비탄성 지진응답 스펙트럼에 심하게 영향을 미쳤으며, 그 현상은 특히 탄성 응답스펙트럼에서 두드러졌다.

  • PDF

Foundation-soil-foundation Interaction of Shallow Foundations Using Geo Centrifuge: Experimental Approach (원심모형실험을 이용한 얕은 기초의 기초-지반-기초 상호작용: 실험적 접근)

  • Ngo, Linh Van;Kim, Jae-Min;Lim, Jaesung;Lee, Changho
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.1
    • /
    • pp.25-35
    • /
    • 2018
  • Geocentrifuge tests are performed to investigate the structure-soil-structure interaction of shallow foundations that have various sizes. The soil specimen is prepared by using the air-pluviation, and the dynamic responses of the foundation are monitored with separation distances between the two foundations and the embedment. During the centrifugal test, the measured ground acceleration shows a tendency to increase with the increase of the input seismic amplitude, and maximum acceleration is measured at the surface due to the ground amplification. As the separation distance between the two foundations decreases, the ratio of the response spectral acceleration (RRS) increases and the period at the peak RRS decreases due to the structure-soil-structure interaction (SSSI). The RRS of the two foundations tends to decrease when the foundations are buried in the ground at the same separation distance.