• Title/Summary/Keyword: 구조물 방호

Search Result 82, Processing Time 0.024 seconds

A Study on Controlled Blasting Design in Construction Field (건설현장에서의 제조 발파 설계에 관한 고찰)

  • 이화창
    • Explosives and Blasting
    • /
    • v.14 no.1
    • /
    • pp.49-63
    • /
    • 1996
  • Blasting is a work that destruct an object by use of explosive. Its use covers a wid range, and it is applicable to blast the rocks, minerals, coal, steel and concrete structures, bridges, etc. To execute the blast plan most effectively, the properties of the object and the explosives should be well understood, and all the other conditions must ve incorporated in its design and plan. A safe blasting pattern and procedure should be selected considering the envirinmental effects and dther conditions. At the same time, a protective protective pricedures should be utilized to prevent the safety hazards such as the excessive blast vubration, air pressure, and the flying fragments. This study reviews the controlled blasting techniques in these regards.

  • PDF

Development of damage assesment of concrete compression member subjected to impact load using Bayesian probabilistic method (Bayesian 통계방법을 이용한 충격하중을 받는 콘크리트 압축부재의 손상평가의 개발)

  • Kim, Seung-Pyo;Yi, Jong-Gil;Yi, Na-Hyun;Kim, Jang-Ho;Lee, Kang-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.161-162
    • /
    • 2010
  • In this study, the impact load on concrete compression member was considered to assess the quantitative damage index. The case study was carried out using the LS-DYNA, on explicit finite element analysis program. The parameters for the case study were impact load angle, slenderness ratio, etc. Using the analysis results, the performance based design method for impact load was developed using Bayesian probabilistic method, which can be applied to reinforced concrete column design for impact loads.

  • PDF

Design Safety Analysis of $9\%$ Nickel Steel Structure in Inner Tank Storage System (내부탱크 저장 시스템에서 $9\%$ 니켈강재 구조물의 설계 안전성에 관한 연구)

  • Kim Chung Kyun;Choi Dong Yul
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.49-55
    • /
    • 2001
  • This paper presents the design safety analysis of the inner tank structure, which is manufactured by 9 percent nickel steel sheets in the full containment type LNG storage tank. The FEM computed results indicate that top girder and several stiffener rings of the inner tank play an important role for controlling the deformation and stress intensity of the inner tank structure. The hydrostatic pressure due to cryogenic fluids gave more influential to the deformation of the inner tank wall compared with that of a cryogenic temperature of $-162^{\circ}C$. But, the deformation and stress of the inner tank. which is produced by the buckling loads, are very small because the external load is not applied to the top of the inner tank. This indicates the role of top girder and stiffener rings of the inner tank model is not important in full containment LNG storage tank.

  • PDF

A Study on the Leak-Proof of Full Containment Type Prestressed Concrete Structure (완전 밀폐형 PC 구조물의 누설 안전성에 관한 연구)

  • Kim Chung Kyun;Cho Seung Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.85-91
    • /
    • 2001
  • This paper presents safety analysis of LNG leakage in a prestressed concrete outer tank, which is strongly related on the leak checking effects of the PC structure with and without a residual compression zone based on the BS 7777 codes. The full containment type outer tank which is constructed by a prestressed concrete may be destroyed by leaked cryogenic fluids. The FE calculated results show that the total leak checking time of the PC structure with $10\%$ residual compression zone is about 9 days for $-162^{\circ}C$ liquids. But, three primary pumps in an inner tank may operate to send cryogenic fluids for 6 days, which are stored in an inner tank of $140,000m^3$ capacity This means that the prestressed concrete outer tank may be safe for $-162^{\circ}C$ cryogenic fluids leaked from the demolished inner tank.

  • PDF

Experimental Study on Blast Resistance Improvement of RC Panels by FRP Retrofitting (철근콘크리트 패널의 FRP 보강에 의한 방폭 성능 향상에 관한 실험 연구)

  • Ha, Ju-Hyung;Yi, Na-Hyun;Kim, Sung-Bae;Choi, Jong-Kwon;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.93-102
    • /
    • 2010
  • Recently, FRP usage for strengthening RC structures in civil engineering has been increasing. Especially, the use of FRP to strengthen structures against blast loading is growing rapidly. To estimate FRP retrofitting effect under blast loading, blast tests with nine $1,000{\times}1,000{\times}150\;mm$ RC panel specimens, which were retrofitted with carbon fiber reinforced polymer (CFRP), Polyurea, CFRP with Poly-urea and basalt fiber reinforced polymer (BFRP) have been carried out. The applied blast load was generated by the detonation of 15.88 kg ANFO explosive charge at 1.5 m standoff distance. The data acquisitions not only included blast waves of incident pressure, reflected pressure, and impulse, but also included central deflection and strains at steel, concrete, and FRP surfaces. The failure mode of each specimen was observed and compared with a control specimen. From the test results, the blast resistance of each retrofit material was determined. The test results of each retrofit material will provide the basic information for preliminary selection of retrofit material to achieve the target retrofit performance and protection level.

Development of Embedded Board for Integrated Radiation Exposure Protection Fireman's Life-saving Alarm (일체형 방사선 피폭 방호 소방관 인명구조 경보기의 임베디드 보드 개발)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1461-1464
    • /
    • 2019
  • In this paper, we propose the development of embedded board for integrated radiation exposure protection fireman's life-saving alarm capable of location tracking and radiation measurement. The proposed techniques consist of signal processing unit, communication unit, power unit, main control unit. Signal processing units apply shielding design, noise reduction technology and electromagnetic wave subtraction technology. The communication unit is designed to communicate using the wifi method. In the main control unit, power consumption is reduced to a minimum, and a high performance system is formed through small, high density and low heat generation. The proposed techniques are equipment operated by exposure to poor conditions, such as disaster and fire sites, so they are designed and manufactured for external appearance considering waterproof and thermal endurance. The proposed techniques were tested by an authorized testing agency to determine the effectiveness of embedded board. The waterproof grade has achieved the IP67 rating, which can maintain stable performance even when flooded with water at the disaster site due to the nature of the fireman's equipment. The operating temperature was measured in the range of -10℃ to 50℃ to cope with a wide range of environmental changes at the disaster site. The battery life was measured to be available 144 hours after a single charge to cope with emergency disasters such as a collapse accident. The maximum communication distance, including the PCB, was measured to operate at 54.2 meters, a range wider than the existing 50 meters, at a straight line with the command-and-control vehicle in the event of a disaster. Therefore, the effectiveness of embedded board for embedded board for integrated radiation exposure protection fireman's life-saving alarm has been demonstrated.

Behavior Analysis of Concrete Structure under Blast Loading : (II) Blast Loading Response of Ultra High Strength Concrete and Reactive Powder Concrete Slabs (폭발하중을 받는 콘크리트 구조물의 실험적 거동분석 : (II) 초고강도 콘크리트 및 RPC 슬래브의 실험결과)

  • Yi, Na Hyun;Kim, Sung Bae;Kim, Jang-Ho Jay;Cho, Yun Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.565-575
    • /
    • 2009
  • In recent years, there have been numerous explosion-related accidents due to military and terrorist activities. Such incidents caused not only damages to structures but also human casualties, especially in urban areas. To protect structures and save human lives against explosion accidents, better understanding of the explosion effect on structures is needed. In an explosion, the blast load is applied to concrete structures as an impulsive load of extremely short duration with very high pressure and heat. Generally, concrete is known to have a relatively high blast resistance compared to other construction materials. However, normal strength concrete structures require higher strength to improve their resistance against impact and blast loads. Therefore, a new material with high-energy absorption capacity and high resistance to damage is needed for blast resistance design. Recently, Ultra High Strength Concrete(UHSC) and Reactive Powder Concrete(RPC) have been actively developed to significantly improve concrete strength. UHSC and RPC, can improve concrete strength, reduce member size and weight, and improve workability. High strength concrete are used to improve earthquake resistance and increase height and bridge span. Also, UHSC and RPC, can be implemented for blast resistance design of infrastructure susceptible to terror or impact such as 9.11 terror attack. Therefore, in this study, the blast tests are performed to investigate the behavior of UHSC and RPC slabs under blast loading. Blast wave characteristics including incident and reflected pressures as well as maximum and residual displacements and strains in steel and concrete surface are measured. Also, blast damages and failure modes were recorded for each specimen. From these tests, UHSC and RPC have shown to better blast explosions resistance compare to normal strength concrete.

The Development of Compressive Strength Estimation Equation for LNG Storage Tank using Rebound Hardness Method (반발경도법을 이용한 LNG 저장탱크 콘크리트의 압축강도 추정식 개발)

  • Kim, Jung-Hoon;Kim, Young-Gu;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.26-32
    • /
    • 2017
  • Outer tank concretes of LNG storage tank are composed of prestressed concrete structures that act as a protective wall. The danger such as the collapse of structures will exist if concrete structures is not secured due to the deterioration. Concrete compressive strength directly related to the safety of structures can be predicted by using estimation equation of compressive strength through rebound hardness test and ultrasonic wave velocity method. But, there is no the estimation equation of LNG storage tank for a relation between NDT data and real strength. In this study, to obtain more accurate real strengths for LNG storage tank, core specimens were sampled from walls of pilot LNG storage tank. The rebound hardness test of general NDT for concrete structures was carried out at each 3 positions for the four areas. The compressive strength estimation equation of LNG storage tank was developed by using the data for rebound hardness test of pilot LNG storage tank and compressive strength test of sampled concrete cores.

Study on building room fire development stages (건축물 실내화재의 단계에 대한 연구)

  • Cha, Jong-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.169-172
    • /
    • 2008
  • The purpose of this paper is to summarize characteristics of fire growth stages, combustion proceeding, human behavior factors against fire, fire active protections, fire alarms in order to perform public safety and protection, personnel property protection, with identification of economic analysis aspects based on respective stages classified as fire generation- fire growth- flashover- fire extinction, which is differ from previous studies that based on distinct concepts such as fire stages, escapes, building construction, fire sensing.

  • PDF

Analysis of Civil Defense Shelters and Measures (민방위 대피소의 실태분석 및 대책방안)

  • Kim, Tae-Hwan
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.31-31
    • /
    • 2011
  • 1990년 이후 공산체계인 구소련과 동구권이 몰락하고 세계적으로 탈냉전의 변화와 우리의 민주정부 수립 후 햇빛정책 등에도 불구하고 북한은 적화통일을 포기하지 않고 작년 11월에 연평도에 포격을 가하여 민간인과, 군이 2명이 사망하는 사건이 발생 하였다. 또한 북한의 공격은 과거의 포탄공격뿐만 아니라 미사일이나 화생방과 같은 생화학물질 탑재 가능한 공격이 예상된다. 이에 대비 정부에서는 고정시설의 화생방 방호는 일단유사시에 국민의 생명과 재산을 보호하는데 필수요소로서 집단보호개념에 도입하고 있으며, 현재 각 중요 대피시설 및 지자체의 기존 대피시설을 개인방호, 탐지, 제독, 운용절차를 포함한 실태파악 및 재래식 탄을 포함한 통합적인 조치를 마련하고 있다. 작년 2010년 11월 연평도에서의 북한 포격이후 우리는 서해5도나 접경지역 주민과 그리고 근접거리의 서울시민들이 안전하게 포격으로부터 피난 할 수 있는 민방위대피소에 대한 문제점이 대두되고 대책방안을 요구하고 있다. 소방방재청 기준에 따르면 직격(直擊) 핵폭탄을 제외한 화생방, 재래식 무기 공격에 견딜 수 있는 시설은 '1등급 대피시설'인데 서울에는 한 곳도 없다. 고층건물의 지하 2층 이하나 지하철, 터널 같은 2등급 대피시설도 폭격은 견딜 수 있지만 화생방 공격에는 취약하다. 지하상가 등 건축물의 지하층, 지하차도나 보도는 그보다 더 취약한 3등급이며 단독 주택의 지하층처럼 방호 효과가 떨어지는 곳이 4등급이다. 2등급으로 분류된 대피소의 경우 분류만 되어 있을 뿐 장기간 대피시 시민들이 사용 할 수 있는 거주공간이 아닌 임시 대피로서의 역할만 하고 있다. 본 연구에서는 민방위 기본법에 따라 지하에 $3.3m^2$ 당 4명 이상이 대피할 수 있는 규모의 공간을 갖추기만 하면 대피시설로 볼 수 있는 현 문제점과 1등급에서 4등급으로 나뉘어져있는 민방위 대피소와 대피소가 있지만 피난공간으로서의 역할과 구조적으로 안전한가에 대한 국내외 실태 분석을 통하여 분석한 결과 우리는 서해5도 대피시설의 반 이상이 무용지물이고 접경지 또한 피난시에 피난장으로서의 대피소가 난방이나, 구급품과 식구 시설 등이 구비가 되어 있지 않고 대피시설로 지정한곳이 간판이나 안내시설이 없다. 외국의 경우 스위스는 연방정부의 관리책임으로 전쟁이나 핵 확산에 따른 화생방 업무 전담팀을 두고 있으며, 방독면은 개인 방호물자로서 전국민 100% 보유하고, 각가정이나 건축, 시설물의 경우 화생방 표준 대피시설 설치관련 규정 마련 시행하고 있다. 대피시설은 화생방 방호가 가능한 지휘부용 대피시설과 일반 주민대피용 시설을 구분하여 설치운영하고 있으며, 전국에 650만개를 설치하고 있다. 결론은 대피시설이 북한 공경시 피난시설로의 활용방안을 모색 등급구분에 따른 현실적용 수정과 기존 대피소 보강과 재선별이 필요하고, 신축시 설계 표준설계안 그리고 기존의 대피소에 대한 보수, 보강방법 가이드라인과 장기간 거주에 대한 설비구축 등과 국민 대홍보등을 제안하였다.

  • PDF