• Title/Summary/Keyword: 구조모드

Search Result 2,710, Processing Time 0.034 seconds

Wideband horn antenna including circular-polarizer and straight-type mode-converter for Ka-band (Ka-대역 원형 편파기와 직선구조 모드 변환기를 포함한 광대역 혼 안테나)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.299-304
    • /
    • 2011
  • In this paper, the circular polarized horn antenna composed of circular polarizer and impedance transformer is designed, and fabricated. For the circular polarizer, two types of the polarizer are designed and the electrical performance of them is compared; rectangular waveguide polarizer with $45^{\circ}$-inclined dielectric slab and oval shaped one. Straight type mode converter has a stepped impedance structure and plays a role of converting waveguide TE mode into coaxial TEM mode, and the proposed antenna is designed to directly connect with active components using the feed-through in the input port of the mode converter. Fabricated antenna has the wideband performance, VSWR<1.5 and Axial ratio < 1.0dB, ranging from 30.085 to 30.885 GHz, and the antenna gain is 6.7~7.0 dBi.

Seismic Fragility Analysis of Multi-Modes Structures Considering Modal Contribution Factor (모드기여도를 고려한 복수모드구조물의 지진취약도분석)

  • 조양희;조성국
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.15-22
    • /
    • 2002
  • In the course of seismic probabilistic risk assessment(SPRA), seismic fragility analysis(SFA) is utilized as a tool to evaluate the actual seismic capacity of structures. This paper introduces a methodology of SFA and its evaluation procedures, especially focusing on the basic fragility variables. A new definition of the response spectrum shape factor as one of the most critical basic variables is suggested. The new factor is expressed as a term of linear algebraic sum using the modal contribution factor. The efficiency of new response spectrum shape factor is evaluated and validated to use in practice through the case study of the nuclear power plant structures. The case study results show that the proposed method can be effectively applicable to multi-mode structures with composite modal damping.

Effects of Reinforced Fibers on Energy Absorption Characteristics under Quasi-static Compressive Loading of Composite Circular Tubes (강화섬유에 따른 준정적 하중하에서 복합소재 원형튜브의 에너지 흡수특성 평가 연구)

  • Kim, Jung-Seok;Yoon, Huk-Jin;Lee, Ho-Sun;Choi, Kyung-Hoon
    • Composites Research
    • /
    • v.22 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • In this study, the energy absorption capabilities and failure modes of four different kinds of circular tubes made of carbon, Kevlar and carbon-Kevlar hybrid composites with epoxy resin have been evaluated. In order to achieve these goals, these tubes were fabricated with unidirectional prepregs and compressive tests were conducted for the tubes under 10mm/min loading speed. From the test results, carbon/epoxy tubes were collapsed by brittle fracturing mode and showed the best energy absorption capabilities, while Kevlar/epoxy tubes were crushed by local buckling mode and worst. The hybrid [$90_C/0_K$] tubes were failed in a local bucking mode and showed good post crushing integrity, whereas [$90_K/0_C$] tubes were failed in a lamina bending mode and bad post crushing integrity.

Estimation of Sound Pressure from Vibration Signals on a Flat Plate and Experiment (진동 신호를 이용한 평판의 음압 분포 예측)

  • Kim, Kwan-Ju;Choi, Sung-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.340-345
    • /
    • 2000
  • 진동하는 구조물의 음향 방사 예측에는 키르히호프-헬름홀쯔 적분 방정식에 근본을 둔 경계 요소 해석이 널리 사용된다. 이 경계 요소 해석은 익히 알고 있듯이 구조물의 동적 거동이 정량적으로 표현될 수 있는 경우는 매우 높은 정확도의 예측 결과를 제공한다. 그러나 실제 현상에서 접할 수 있는 복잡한 구조물의 음향 방사 예측에는 많은 변수들로 인해 예측의 정확도가 감소됨은 확실하다. 다른 방법으로는 실험을 통한 임의의 음장 예측 방법인 근음장 음향 홀로그래피(nearfield acoustical holography) 방법을 들 수 있다. 이 방법은 실제로 발생되는 음향 방사로부터 마이크로폰을 이용하여 홀로그램면의 음압 또는 속도를 측정하고 키르히호프-헬름홀쯔 적분 방정식에 적용하여 임의의 홀로그램면에 투사(mapping)시켜 음장을 예측하는 방법이다. 근음장 음향 홀로그래피는 탁월한 정확성을 갖고 있으나, 측정의 복잡성과 홀로그램면을 형성하기 위한 많은 이산점(절점)의 필요성 등의 단점을 갖고 있다. 본 논문에서는 또 다른 음장 예측 방법인 실험의 장점과 유한 요소 해석의 장정을 복합시킨 모드 확장 방법(modal expansion method)을 사용하여 단순 구조물인 평판의 진동에 의한 음장을 예측해 보았다. 모드 확장 방법은 구조물의 동적 거동은 모드의 선형 조합으로 표현될 수 있다는 것에 그 원리를 둔다. 본 논문은 단순 평판을 대상으로 유한 요소 해석으로 구한 모드 정보와 실험에 의해 얻은 입의 가진 주파수에 대한 진동 표면의 속도 분포를 조합하여 속도 경계 조건을 구성, 경계 요소 해석으로 음장 예측을 수행하였으며 모드 확장 방법을 사용함에 있어 고려해야할 몇 가지 사항에 대해 다루었다.

  • PDF

Investigation on Friction Noise in Beam Structure Under Mode-Coupling by Using Analytical Finite-Element Squeal Model (스퀼 융합모델을 이용한 모드연성에 의한 빔 구조 마찰 소음 연구)

  • Kang, Jaeyoung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.545-550
    • /
    • 2014
  • This study provided the analytical finite element method estimating the friction-induced noise on the complex beam structure. The frictional contact model was theoretically constructed and applied to the analytical finite element squeal model. The numerical results showed that the beam structure was excited by the mode-coupling instability of the specific system modes. Also, the direction of friction was shown to influence on the dynamic instability of the modes. Besides, the unstable modal frequencies estimated from the numerical calculation were validated by the experiment of the actual beam structure.

Surface Plasmon Modes Confined in the Gap Between Metal Nanowire and Dielectric Slab (유전체 판과 금속 나노선 사이에 구속된 표면 플라즈몬 모드)

  • Hahn, Chol-Oong;Oh, Cha-Hwan;Song, Seok-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.6
    • /
    • pp.269-275
    • /
    • 2011
  • We propose a metal-dielectric hybrid waveguide structure consisting of a single metal nanowire placed on a flat dielectric slab. Mode size and propagation loss of the surface-plasmons confined in the metal-dielectric gap are compared with those of the complementary structure with a dielectric nanowire on a metal surface. In the case of the nanowire's diameter much smaller than the wavelength the two structures reveal quite different characteristics; the dielectric nanowire-on-metal has longer propagation distance, but only the metal nanowire-on-dielectric exhibits a mode size two fold smaller than the diffraction limit. The proposed hybrid structure may therefore be more suitable for realization of nanocavity lasers.

Engineering Evaluation of Seismic Sity Coefficient in the Korean Bridge Code (국내 도로교시방서 내지설계편의 지반계수에 대한 공학적 영향평가)

  • 조양희;조인범
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.123-134
    • /
    • 1998
  • 본 연구에서는 지반상태가 교량의 지진응답에 미치는 영향을 분석하기 위해 다양한 지반모델 상의 교량모델에 대한 지진해석을 수행하고 그 결과를 비교.분석하였다 이를 위해서 기존의 교량시방서에서 분류된 네가지의 서로다른 지반종류를 대상으로 보다 세분된 지반모델 상에 위치하는 대표적인 교량에 대한 지진해석을 수행함으러써 첫째로는 각 지반 종류 상호간의 지진응답 차이의 정도를 시방서 값과 비교.분석하였으며 둘째로는 동일 지반으로 분류되는 상이한 두 지반간의 응답차이의 정도를 확인하였다 해석을 위해서는 시방서에서 제시된 두가지 방법 즉 단일모드 스펙트럼해석법과 다중모드 스펙트럼해석법을 사용하였으며 이들 결과를 별도로 작성된 인공시간이력을 입력으로 하는 시간이력해석법을 사용한 결과와 비교.분석하였다 시간이력해석법에서는 진동수에 무관한 지반임피던스함수를 이용하는 시간영역해석법을 사용하였다 해석결과 시방서에서 제시한 단일모드 및 다중모드 스펙트럼해석방법은 일반적으로 안전측의 지반-구조물 상호작용 해석결과를 주는 것으로 확인되었다 그러나 유연성이 큰 지반 상의 구조물에대한 지진해석을 위한 해석모델 작성시에는 지반의 유연성이 반드시 고려되어야 하며 특히 낙교방지를 위한 변위는 지반의 유연성을 고려한 정밀해석법에 의한 계산이 필수적으로 요구됨을 확인하였다.

  • PDF

Compact and Low Insertion Loss Dual-Mode Resonator and Its Applications for Switchable Filters (낮은 삽입손실을 갖는 소형 이중모드 공진기와 스위치 기능을 가진 여파기로의 응용)

  • 성영제;김보연;이건준;김영식
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.301-310
    • /
    • 2004
  • In this paper, a compact dual-mode filter structure without coupling gaps is proposed. The novel design is achieved by embedding a pair of equal crossed slots and spur-lines. Without coupling gaps between feed lines and patch resonator, the new filter can provide low insertion loss. It is found that this design has wide coupling range for dual-mode operation. It means that these characteristics of the proposed filter can reduce uncertainty in fabrication. By using two PIN diodes mounted inside a pair of spur-lines, the proposed structure works as a switchable filter. Also, it has a size reduction of about 34.7 %, compared with conventional dual-mode filters.

A Method for Vibration and Sensitivity Analysis of Structure Systems with Non-linear Characteristics (비선형 특성을 가진 구조시스템의 진동과 감도해석 방법)

  • Moon, Byung-Young;Kim, Sa-Soo;Iwatsubo, Takuzo
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.4 s.35
    • /
    • pp.10-18
    • /
    • 1999
  • 본 논문에서는 대형구조물의 해석에 있어서 부분구조합성법과 섭동법을 이용하여 복잡한 비선형시스템의 해석방법을 제안하였다. 해석방법은 전체시스템을 먼저 몇 개의 분계로 분할한다. 각 분계의 운동방정식에 비선형항이 존재하여도 전체시스템의 지배적 진동모드는 선형모드라는 가정하에 이 시스템의 각 분계를 모드좌표로 변환한다. 이때, 비선형항은 근사적으로 변환한다. 그리고 섭동법을 이용하여 각 분계의 모드좌표방정식은 섭동좌수별로 정식화되어 순차적으로 구해진다. 비선형의 감도는 비선형계수로 정의되고, 그에 상응하는 강성에 의해 구해진다. 제안된 해석방법으로 비선형회전체, 비선형 베어링-페데스탈로 구성된 대형시계구조물의 진동을 해석하였다. 해석방법의 유효성을 평가하기 위해 응답의 정도와 계산소요시간을 유한요소법의 결과와 비교 분석하였다.

  • PDF

The Effect of Higher Vibration Modes on the Design Seismic Load (고차진동모드의 영향을 고려한 층지진하중)

  • 이동근;신용우
    • Computational Structural Engineering
    • /
    • v.3 no.4
    • /
    • pp.123-132
    • /
    • 1990
  • In current practice of earthquake resistant design the equivalent lateral force procedure is widely used because of its simplicity and convenience. But the equivalent lateral force procedure is derived based on the assumptions that the dynamic behavior of the structure is governed primarily by the fundamental vibration mode and the effect of higher modes is included in an approximate manner. Therefore the prediction of dynamic responses of structures using the equivalent lateral force procedure is not reliable when the effect of higher vibration modes on the dynamic behavior is significant. In this study, design seismic load which can reflect the effect of higher vibration modes is proposed from the point of view of proper assessment of story shears which have the major influence on the design moment of beams and columns. To evaluate the effect of higher modes, differences between the story force based on the equivalent lateral force procedure specified in current earthquake resistance building code and the one based on modal analysis using design spectrum analysis are examined. From these results an improved design seismic load for the equivalent lateral force procedure which can reflect the effect of higher vibration modes are proposed.

  • PDF