• Title/Summary/Keyword: 구상 돌기

Search Result 21, Processing Time 0.018 seconds

Coronoid view: A New Radiograph for the Evaluation of the Coronoid Fractures (Coronoid view: 구상돌기 골절을 평가하는 새로운 방사선 촬영법)

  • Song, Joo-Hyoun;Lee, Joo-Yup;Yang, Sung-Cheol;Lee, Han-Yong;Kim, Jong-Ik
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.199-203
    • /
    • 2007
  • Purpose: It is very important to evaluate and fix coronoid process fractures because they are a critical element for a stable, effective elbow function. The lateral view of the elbow joint is used for a radiographic evaluation of the coronoid but an understanding of the fracture pattern is often difficult because of overlap of the radial head and obliquity of the fracture line. We developed the coronoid view, which is a new radiograph for an evaluation of the coronoid process fracture, and discuss its advantages for a postoperative follow-up. Materials and Methods: The coronoid view was designed for an evaluation of the anteromedial fragment of the coronoid process. After the patient sat on his side, the shoulder was abducted $45^{\circ}$ and the elbow was flexed $90^{\circ}$. The X-ray beam was shot perpendicular to the table. Since shoulder was abducted $45^{\circ}$ the fracture line of the coronoid process can be parallel to the X-ray beam, and the radial head can be cleared. Conclusion: The coronoid view can be a good alternative radiograph for an evaluation of a coronoid process fracture because the beam is parallel to the fracture line. The coronoid view can be particularly useful in postoperative patient follow-up where computed tomography is impractical due to metal implants and cost.

금속판을 이용한 구상돌기 골절의 치료

  • Sin, Dong-Ju;Byeon, Yeong-Su;Jo, Yeong-Ho;Park, Ho-Won;Yun, Hui-Min;Han, Jae-Hwi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.130-130
    • /
    • 2009
  • 불안정한 주관절이 동반된 전위된 구상돌기 골절들을 내측 접근법을 통한 금속판 고정으로 안정된 고정과 만족스러운 골유합을 얻을 수 있었다.

  • PDF

Plate Fixation for Fractures of the Coronoid Process of the Ulna (금속판을 이용한 구상돌기 골절의 치료)

  • Shin, Dong-Ju;Byun, Young-Soo;Cho, Young-Ho;Park, Ho-Won;Youn, Hee-Min;Han, Jae-Hui
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.177-184
    • /
    • 2008
  • Purpose: The purpose of this study was to evaluate the results of eight cases of coronoid process fractures that were fixed with a plate. Materials and Methods: Eight coronoid process fractures were treated by plating and these cases were reviewed retrospectively. Six patients were men and two were women. The average age was 41 years (range: 22-79) at the time of injury. According to Regan's classification, there were five type 2 and three type 3. According to O'Driscoll's classification, there were five anteromedial type and three base type. Open reduction and internal fixation with a plate were performed through a medial approach by splitting of the two heads of the flexor carpi ulnaris. The patients were follow-up for a mean of 15.8 months (range: 6-25). We evaluated the clinical outcomes with using the Mayo Elbow Performance Score. Results: The average active motion of the elbow joint was $120^{\circ}$. The average Mayo Elbow Performance Score was 86.9. There were 5 excellent results, 1 good result and 2 fair results. Summary: Plating through a medial approach of the elbow provided stable fixation and satisfactory union for treating displaced coronoid process fractures with the unstable elbow.

The Volar Plating of Fracture of the Coronoid Process - Report of Two Cases - (구상돌기 골절에서 내측 접근법을 통한 전방 금속판 고정술 - 2예 보고 -)

  • Jung, Gu-Hee;Cho, Chul-Hyun;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.260-265
    • /
    • 2010
  • Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

Relationship of Trochlear Medial Facet Osteophyte to Elbow Flexion in Elbow Joint without Trauma History (외상력이 없는 주관절에서 활차 내측 골극과 주관절 굴곡 제한과의 관계)

  • Kim, Byung Sung;Park, SungYong;Park, Kang Hee;Song, Hyun Seok;Kim, Hyung Tae;Yoon, Hong Kee;Nho, Jae Hwi
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.100-106
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the relationship between trochlear medial facet osteophyte (TMFO) and elbow flexion in the elbow joints without trauma history. Materials and Methods: Twenty five patients, who underwent computed tomography without elbow trauma history, were reviewed. Patients were checked for osteophyte or loose bodies in the coronoid and olecranon sides. The height and length of TMFO were measured. Results: The average elbow flexion contracture was $18.6^{\circ}$, and further flexion was $112.1^{\circ}$. The TMFO height and length was 2.2 mm and 4.7 mm, respectively. The average elbow further flexion was $105.1^{\circ}$ in the coronoid block group (n=14) and $119.1^{\circ}$ (p=0.011) in the coronoid free group (n=11). The relationship between further elbow flexion and TMFO was significant with a partial correlation coefficient of 0.687(p<0.000) in the TMFO length. Conclusion: Elbow joints with longer TMFO length decrease further flexion.

Improvement of the Elbow Function with Early Mobilization and Rigid Fixation of Coronoid Fracture by Tension Band Technique (압박 긴장대 방법을 이용한 구상 돌기 골절의 견고한 고정과 조기 운동을 통한 주관절 기능의 향상)

  • Rhyou, In-Hyeok;Suh, Bo-Gun;Kim, Hyung-Jin;Chung, Chae-Ik;Kim, Kyung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.159-166
    • /
    • 2009
  • Purpose: We wanted to evaluate the surgical results of early mobilization after rigid fixation of small coronoid fracture using the tension band technique Materials and Methods: Eight cases of coronoid fracture were fixed with the tension band technique and using K-wire and wire through the medial approach. All the cases were Regan-Morrey type 2. According to O'Driscoll, they were classified as 5 cases of the tip type (subtype 2) and 3 cases of the anteromedial type (1 case of subtype 2, and 2 case of subtype 3). The associated collateral ligament injuries (6 cases) and radial head/neck fractures (4 cases) were managed simultaneously. After immobilization for 5~7 days, active ROM exercise with a fitted hinge brace started and continued till postoperative 6 weeks. The patients were assessed for pain, ROM and functional disability using the Mayo elbow performance score (MEPS) at an average of 11 months (range: 6~28 months). The ulnar nerve symptoms were also investigated. Results: We observed solid union in all the coronoid fractures without hardware failure. An average of 2.2 wires (range: 2~4) were used. The mean extension was $3^{\circ}$(range: $0^{\circ}\sim25^{\circ}$), the mean flexion was $137^{\circ}$(range: $130^{\circ}\sim140^{\circ}$), the mean pronation was $69^{\circ}$(range: $45^{\circ}\sim90^{\circ}$) and the mean supination was $78^{\circ}$(range: $45^{\circ}\sim90^{\circ}$). The mean MEPS was 96 (range: 65~100). Ulnar nerve symptoms occurred at postoperative one day and persisted in one patient with the terrible triad of taking radial head excision and residual medial instability. Conclusion: The tension band technique uses easily obtained, economic K-wires and the wire was strong enough to permit early elbow ROM exercise and the technique might improve the elbow function. It was especially useful for fixation of multiple small fragments.