Abstract

Purpose: To report the clinical results of two cases of coronoid process fractures that were treated with volar plating through a medial approach. Materials and Methods: Two fractures of the coronoid process that needed to be fixed were managed with open reduction and internal fixation through a medial approach using 2.4 mm locking compression plates (Compact Hand set$^{(R)}$, Synthes, Switzerland). The patients were followed up for 14 months and 17 months and were evaluated using the Mayo Elbow Performance Score (MEPS). Results: The MEPS was 95 for Case 1 and 100 for Case 2. Active elbow joint motions were $5^{\circ}-120^{\circ}$ (Case 1) and $0^{\circ}-130^{\circ}$ (Case 2). Supination and pronation fully recovered. Conclusion: Satisfactory results can be obtained in cases of coronoid process fractures because volar plating through a medial approach allows sound fixation and early mobilization of the elbow joint.

목적: 척골 구상돌기 골절에 대해 내측 접근법을 통한 전방 금속판 고정술이 시행된 2예의 임상적 결과를 보고하고자 한다. 대상 및 방법: 수술적 치료가 필요한 척골 구상돌기 골절 2예에서 척 수근 굴근 양 두 사이로 접근하는 내측 접근법을 통해 2.4 mm 잠김 압박 금속판 (Compact Hand set$^{(R)}$, Synthes, Switzerland)을 이용한 전방 금속판 고정술이 시행되었다. 추시 기간은 각각 14개월, 17개월이었으며, Mayo Elbow Performance Score로 임상적 결과를 판정하였다. 결과: Mayo Elbow Performance Score는 각각 95점 (증례 1), 100점 (증례 2)이었다. 능동적 주관절 운동 범위는 $5^{\circ}{\sim}120^{\circ}$, $0^{\circ}{\sim}130^{\circ}$이었고, 회내 및 회외 영역은 모두 회복되었다. 결론: 내측 접근법을 통한 전방 금속판 고정술은 척골 구상돌기 골절에서 견고한 고정 및 조기 관절운동을 가능하게 하여 우수한 치료 결과를 얻을 수 있었다.

Keywords

References

  1. Adams JE, Hoskin TL, Morrey BF, Steinmann SP: Management and outcome of 103 acute fractures of the coronoid process of the ulna. J Bone Joint Surg Br, 91: 632-635, 2009. https://doi.org/10.1302/0301-620X.91B5.21755
  2. Giannoudis PV, Tzioupis C, Moed BR: Two-level reconstruction of comminuted posterior-wall fractures of the acetabulum. J Bone Joint Surg Br, 89: 503-509, 2007. https://doi.org/10.1302/0301-620X.89B4.18380
  3. Jeon IH, Min WK, Oh CW, et al.: Operative treatment of type III coronoid process fractures. J Korean Fracture Soc, 17: 338-344, 2004.
  4. Morrey BF, An KN, Chao EYS: Functional evaluation of the elbow. In Morrey BF ed. The elbow and its disorders. 3rd ed, Philadelphia, WB Saunders: 74-83, 2000.
  5. O’Driscoll SW, Jupiter JB, King GJ, Hotchkiss RN, Morrey BF: The unstable elbow. Instr Course Lect, 50: 89-102, 2001.
  6. Regan W, Morrey B: Fractures of the coronoid process of the ulna. J Bone Joint Surg Am, 71: 1348-1354, 1989.
  7. Ring D, Doornberg JN: Fracture of the anteromedial facet of the coronoid process. Surgical technique. J Bone Joint Surg Am, 89 Suppl 2 Pt.2: 267-283, 2007. https://doi.org/10.2106/JBJS.G.00059
  8. Ring D, Jupiter JB: Fracture-dislocation of the elbow. J Bone Joint Surg Am, 80: 566-580, 1998. https://doi.org/10.1302/0301-620X.80B4.9165
  9. Sanchez-Sotelo J, O’Driscoll SW, Morrey BF: Medial oblique compression fracture of the coronoid process of the ulna. J Shoulder Elbow Surg, 14: 60-64, 2005. https://doi.org/10.1016/j.jse.2004.04.012
  10. Shin DJ, Byun YS, Cho YH, Park HW, Youn MH, Han JH: Plate fixation for fractures of the coronoid process of the ulna. J Korean Shoulder Elbow Soc, 11: 177-184, 2008. https://doi.org/10.5397/CiSE.2008.11.2.177