• Title/Summary/Keyword: 구멍

Search Result 1,231, Processing Time 0.03 seconds

Detection of Fatigue Damage in Aluminum Thin Plates with Rivet Holes by Acoustic Emission (리벳 구멍을 가진 알루미늄 박판구조의 피로손상 탐지를 위한 음향방출의 활용)

  • Kim, Jung-Chan;Kim, Sung-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.246-253
    • /
    • 2003
  • The initiation and growth of short fatigue cracks in the simulated aircraft structure with a series of rivet holes was detected by acoustic emission (AE). The location and the size of short tracks were determined by AE source location techniques and the measurement with traveling microscope. AE events increased intermittently with the initiation and growth of short cracks to form a stepwise increment curve of cumulative AE events. For the precise determination of AE source locations, a region-of-interest (ROI) was set around the rivet holes based on the plastic zone size in fracture mechanics. Since the signal-to-noise ratio (SNR) was very low at this early stage of fatigue cracks, the accuracy of source location was also enhanced by the wavelet transform do-noising. In practice, the majority of AE signals detected within the ROI appeared to be noise from various origins. The results showed that the effort of structural geometry and SNR should be closely taken into consideration for the accurate evaluation of fatigue damage in the structure.

Analysis of the Effect on the Process Parameters for the Thin Ceramic Plate in the Ceramic Injection Molding (판상제품의 세라믹 사출 시 공정변수 영향 분석)

  • Kim, Jinho;Hong, Seokmoo;Hwang, Jihoon;Lee, Jongchan;Kim, Naksoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2587-2593
    • /
    • 2014
  • Ceramic Injection Molding (CIM) is one of wide used processes in industry field and the applications are gradually being expanded to parts of medical and electric devices. In this study, the CIM process were analyzed with FEM and process parameters were studied and analyzed the effect on product quality. The shape of simple flat plate was compared to the shapes with the hole, with the round corner portion or with the side wall portion. If there are holes then the hole around the uneven density distribution and the defects such as weld lines could be occurred. The Large radius of the corners of the product give good formability and fluidity. Not only the shape parameters of product but also the process parameters during CIM are studied. The simulation results showed that the process parameters of temperature, initial fractions and velocity are important design parameters to improve the quality of products.

Enzymatic Hydrolysis of Pre-treated Ulva pertusa with Alkaline Peroxide (구멍갈파래의 알칼리 과산화수소 전처리 및 효소 가수분해 특성)

  • Yoon, Byung-Tae;Kim, Young-Wun;Chung, Keun-Wo;Kim, Jin-Seog
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.336-339
    • /
    • 2011
  • Algae is an abundant and potential fermentation substrate. The enzymatic hydrolysis of algae was investigated by pre-treating an alkaline hydrogen peroxide with commercial cellulase and viscozyme. Algae used in this study was the Ulva pertusa. The evaluated response was the yield of released glucose after the enzymatic hydrolysis. Alkaline hydrogen peroxide containing mixtures of 1 wt% hydrogen peroxide and 1~1.75 wt% sodium hydroxide was also used. The results show that the highest glucose conversion was obtained for Ulva pertusa using 5 wt% hydrogen peroxide at $60^{\circ}C$ for 3 h. The required amount of enzymes after the pre-treatment with alkaline hydrogen peroxide were reduced by far compared to that of untreated Ulva pertusa. Also, the amount of glucose that is released during the enzymatic hydrolysis was increased.

Safety Evaluation of Carbon Fiber/Epoxy Composite Link Using Micromechanics of Failure Criterion (미시역학적 파손 기준을 이용한 탄소섬유/에폭시 복합재 링크의 안전성 평가)

  • Jae Ho Cha;Sung Ho Yoon
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.154-161
    • /
    • 2023
  • This study explored the feasibility of replacing a metal link with a carbon fiber/epoxy composite link and assessed its capacity to withstand a given load condition using failure criteria. The micromechanics of failure (MMF) criterion was employed to predict the failure mode of the composite material, and mechanical tests were conducted to obtain reference strength parameters for MMF. The findings revealed that the stress distribution was concentrated near the hole, and weaknesses were found around the hole and at the end of the link under bending conditions. Based on the failure index, matrix tensile failure was predicted at the end of the link, and fiber compression failure occurred near the hole. The methods and results obtained from this study can provide valuable guidelines for assessing the safety of composite materials under specific load conditions when replacing metal parts with carbon fiber/epoxy composites to achieve weight reduction.

Composite Behavior of Perfobond Rib Shear Connector for Steel-concrete Decks (강-콘크리트 합성 바닥판용 전단연결재의 합성 거동 연구)

  • Kim, Hyeong-Yeol;Koo, Hyun-Bon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1A
    • /
    • pp.91-97
    • /
    • 2006
  • This paper presents the results of push-out test conducted for the perfobond rib shear connectors welded onto steel-concrete composite deck. Push-out test specimen consists of profiled steel sheeting, perfobond rib, reinforcement, and concrete. To provide longitudinal shear resistance between the profiled sheeting and the concrete, perfobond rib with a number of holes was used. The parameters considered in the design of perfobond rib were the spacing and location of holes, and effect of reinforcing bars placed in the holes. To validate the effectiveness of the proposed system, twelve specimens were fabricated and tested. Although the scope of test was limited in nature, the results of test have shown that the perfobond ribs can be effectively used for shear connection in the steel-concrete composite decks.

Studies on the Storage Stability of Traditional Andong sikhe using Lactobacillus delbreuckii (Lactobacillus delbreuckii를 이용한 전통안동식혜의 저장 안정성)

  • Choi, Cheong;Son, Gyu-Mok;Woo, He-Sob
    • Journal of the Korean Society of Food Culture
    • /
    • v.7 no.4
    • /
    • pp.329-338
    • /
    • 1992
  • This study was attempted aimed to prepare of Andong sikhe by pure culture inoculation and to improve storage stability by the addition of stabilizers to the product. Lactobacillus delbreuckii was selected for pure culture inoculation in the fermentation. The effect of stabilizers on the sedimentation, sensory evaluation and viscosity of Sikhe were investigated during the fermentation of traditional Andong Sikhe stored at $4^{\circ}C$ Morphological characteristics of Sikhe were determined by scanning electromicrograpy. Among the stabilizers added to the traditional Andong sikhe Na-alginate was found to be best stabilizers. When the product was evaluated by the sensory panel, the addition of stabilizers up to 0.1% level actually increased the acceptability of the product, while the concentration of more than 0.2% stabilizers affected the acceptability of the negatively. Sikhe added Na-carboxymethyl cellulose and Na-alginate showed highest viscosity on the 2nd day of fermentation, while homogenized Andong sikhe with Carrageenan showed the highest peak in viscosity on the first day of fermentation. Lactic acid bacterial count reached to $3.2{\times}10^8/ml$ after 20 days of storage. The surface and cross section of rice was observed by scanning electron microscope. As the fermentation proceeded holes on the surface increased, and nearly empty cell wall remained at the later stage of fermentation. Use of pure cultured inoculum of L. delbreuckii supported the rapid build up of the lactic acid bacteria and consequently the whole process of the fermentation was shortened. The acceptability and product quality were improved by use of L. delbreuckii inoculum.

  • PDF

Anchor Hole Augmentation with Bone Cement in Arthroscopic Rotator Cuff Repair (관절경적 회전근 개 봉합술에서 골 시멘트를 이용한 봉합 나사 구멍 보강술)

  • Lee, Ho-Min;Tae, Suk-Kee;Park, Jeong-Min
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.237-243
    • /
    • 2010
  • Purpose: In arthroscopic rotator cuff repair, the crucial step is secure fixation of Anchor to bone. However, osteoporosis of the tuberosity is frequently encountered in old patients, and can cause insecure fixation of anchors. The Aim of our study was to introduce a technique for anchor hole augmentation with bone cement when fixation failure of an anchor occurs, and to investigate the outcome. Materials and methods: Among 223 rotator cuff repairs performed between 2005 and 2009, anchor hole augmentation with polymethylmethacrylate was performed in 15 cases (all females; mean age of 65 years: range 49~77). Bone cement was injected into the anchor hole in a thick fluid state and the procedure was repeated to make a pot-like cement mantle. The anchor was inserted into the cement mantle while the cement hardened. The outcome was investigated, on average, at 16 months (6~32). Results: Radiographs showed cystic changes of the tuberosity. On follow-up radiographs and MRI, a change in the cement mantle was not noted. The final average UCLA score was 31 (28~35); 6 had excellent, 8 good and 1 fair results (p=0.008). Age-sex matched Constants score was 90 (74~98) (p=0.008). Conclusion: Anchor hole augmentation with bone cement is useful when fixation failure of an anchor is encountered due to bone atrophy. Anchor hole augmentation with bone cement does not negatively influence the outcome.

Experimental Investigation on the Behaviour of CFRP Laminated Composites under Impact and Compression After Impact (CAI) (충격시 CFRP 복합재 판의 거동과 충격후 압축강도에 관한 실험적 연구)

  • Lee, J;Kong, C;Soutis C.
    • Composites Research
    • /
    • v.16 no.4
    • /
    • pp.66-73
    • /
    • 2003
  • The importance of understanding the response of structural composites to impact and CAI cannot be overstated to develop analytical models for impact damage and CAI strength predictions. This paper presents experimental findings observed from quasi-static lateral load tests, low velocity impact tests. CAI strength and open hole compressive strength tests using 3 mm thick composite plates($[45/-45/0/90]_{3s}$- IM7/8552). The conclusion is drawn that damage areas for both quasi-static lateral load and impact tests are similar and the curves of several drop weight impacts with varying energy levels(between 5.4 J and 18.7 J) follow the static curve well. In addition, at a given energy the peak force is in good agreement between the static and impact cases. It is identified that the failure behaviour of the specimens from the CAI strength tests was very similar to that observed in laminated plates with open holes under compression loading. The residual strengths art: in good agreement with the measured open hole compressive strengths. considering the impact damage site area, an equivalent hole. The experimental findings suggest that simple analytical models for the prediction of impact damage area and CAI strength can be developed on the basis of the failure mechanism observed from the experimental tests.

Coded Aperture Gamma Camera for Thyroid Imaging: Monte Carlo Simulation (갑상선 영상 획득을 위한 부호화 구경 감마카메라: 몬테칼로 시뮬레이션 연구)

  • Beak, Cheol-Ha;Lee, Seung-Jae;Chung, Yong-Hyun
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.247-255
    • /
    • 2008
  • A coded aperture camera has been developed to improve the signal-to-noise ratio (SNR) while keeping the spatial resolution of a pinhole gamma camera. The purpose of this study was to optimize a coded aperture camera and to evaluate its possibility for thyroid imaging by Monte Carlo simulation. A clinical gamma camera, a pinhole collimator with 1.0 mm hole diameter, and a $79{\times}79$ modified uniformly redundant array (MURA) mask were designed using GATE (Geant4 Application for Tomographic Emission). The penetration ratio, spatial resolution, integral uniformity and signal-to-noise ratio (SNR) were simulated and evaluated as a function of the mask thickness. The spatial resolution of the coded aperture camera was consistent with the various mask thickness, SNR showed a maximum value at 1.2 mm mask thickness and integral uniformity was improved by increasing mask thickness. Compare to the pinhole gamma camera, the coded aperture camera showed improved SNR by a factor of 30 while keeping almost the same spatial resolution. In this simulation study, the results indicated that high spatial resolution and ultra-high SNR of the thyroid imaging are feasible using a coded aperture camera.

  • PDF

Effect of Microsparged Aeration on Oxygen Transfer Rate and Cell Viability in Mammalian Cell Culture Bioreactor (동물 세포 반응기에서의 초미세 통기법이 산소 전달 속도와 세포 생존율에 미치는 영향)

  • 김정모;장건희;최춘순;김정회
    • Microbiology and Biotechnology Letters
    • /
    • v.29 no.4
    • /
    • pp.240-247
    • /
    • 2001
  • The effect of microsparged aeration in mammalian cell bioreactor on the oxygen transfer rate and cell viability was studied. The microspargers with differ- ent micron-sized pores were used to supply oxygen to the medium. The oxygen transfer coefficients (k$_{L}$a) measured in the bioreactor were markedly increased, which is due to the increase of the contacting area between air bubbles and liquid medium when the pore size of microsparger decreases. When the impellers of two different types (square-pitch marine impeller and $45^{\circ}$ pitched flat blade impeller) were used for agitation, the k$_{L}$a values were slightly higher with the marine impeller than with the blade impeller. The detrimental effect of direct gas sparging with microsparger on mammalian cells was investigated in bubble columns with various air flow rates and different pore sized microspargers. The first-order cell death rate constant ($k_{d}$ /7) was shown to be directly proportional to the air flow rate and inversely proportional to the pore size. During the cultivation of hybridoma cells using microsparger with the pore size of $0.57\mu$m in the mammalian cell culture bioreactor, the continuous sparging caused the cell death and suppressed the cell growth. However, cells grew normally and cell viability was maintained above 90% in the logarithmic phase when the air was intermittently sparked in order to maintain the dissolved oxygen level above 20%.

  • PDF