• Title/Summary/Keyword: 구경 크기

Search Result 83, Processing Time 0.022 seconds

DISK OF Be STAR WITH EMISSION (Hα 방출선을 통한 Be 항성 원반)

  • Ahn, Dae-Gun;Bae, Jang-Ho;Lee, Sang-Gak;Shin, Young-Woo;Ko, Yeon-Gyung;Kang, Suk-Chul
    • Publications of The Korean Astronomical Society
    • /
    • v.22 no.4
    • /
    • pp.133-140
    • /
    • 2007
  • We have determined the disk size of Be stars by using $H{\alpha}$ emission. We observed spectra of Be stars with telescope in SNU, equipped with SB SGS (Santa Babara Self Guided Spectrograph) and CCD ST-8. The size of disk of Be stars was estimated with the Be star model of Grundstrom & Gies (2006). This study suggests that the medium resolution spectra taken with small telescope equipped with commercial spectrograph are useful to estimate the approximate size of the $H{\alpha}$ emitting disk around Be stars.

CHARACTERISTICS OF TRAO 14M RADIO TELESCOPE (1999) (대덕전파천문대 14m 전파망원경의 특성(1999))

  • ROH DUK-GYOO;JUNG JAE HOON
    • Publications of The Korean Astronomical Society
    • /
    • v.14 no.2
    • /
    • pp.123-128
    • /
    • 1999
  • The beam size and the antenna efficiency of TRAO 14m radio telescope were measured at 86.2, 98.0 and 115.2 GHz. The beam size was determined by deconvolving the azimuthal scanning data of the Venus. To test the accuracy of our deconvolution method, the beam size at 86.2 GHz was compared with that determined from the mapping data of SiO maser line and we found no difference between them. With above beam sizes, antenna efficiencies were calculated from the continuum measurements of Venus, Jupiter and Moon. The beam efficiencies at these frequencies are appeared to be 0.49, 0.45 and 0.41, respectively. On the other hand, we also suggest that an automatic focus setting can be adopted for TRAO radio telescope based on the gradual change of best focus with elevation.

  • PDF

Fabrication and Evaluation of High Frequency Ultrasound Receive Transducers for Intravascular Photoacoustic Imaging (혈관내 광음향 영상을 위한 고주파수 초음파 수신 변환기 제작 및 평가)

  • Lee, Jun-Su;Chang, Jin Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.300-308
    • /
    • 2014
  • Photoacoustic imaging is a useful tool for the diagnosis of atherosclerosis because it is capable of providing anatomical and pathological information at the same time. A photoacoustic signal detector is a pivotal element to achieve high spatial resolution, so that it should have broadband spectrum with a high center frequency. Since a photoacoustic imaging probe is directly inserted into blood vessel to diagnose atherosclerosis, the total size of the photoacoustic signal detector should be less than 1 mm. The main purpose of this paper is to demonstrate that PVDF can be used as an active material for the photoacoustic signal detector with a high frequency and broadband characteristic. The photoacoustic signal detector developed in this study was a single element ultrasound transducer with an aperture of $0.5{\times}0.5mm$ and the total size of 1 mm. In the design stage, the natural focal depth was adjusted for an effective focal area to cover the region of interest, i.e., 1~5 mm in depth. This was because geometrical focusing could not be used due to the small aperture. Through a pulse-echo test, it was ascertained that the developed photoacoustic signal detector has the -6 dB bandwidth ranging between 40.1 and 112.8 MHz and the center frequency of 76.83 MHz.

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

Development and Design of the Optical System of a Night Scope (Night Scope 광학계의 설계 및 개발)

  • Lee, Dong-Hee;Lim, Yang-Moo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 2004
  • We tried to design and manufacture a night scope which is used in the leisure sports field. The whole system consists of an IR light source part, an objective lens part, an intensifier tube part and an eye_piece lens part. We designed an objective lens part to the infinite object imaging optical-system with 80mm focal-length, 40mm effective-aperture and 14mm image-field-size of which the chromatic aberration is reduced by using materials of BK7 and FD4. The resolution of this system is about 25lines/mm at the 40% MTF value criterion. The eye_piece lens is adopted goods to be used commercially to save cost of production. The design technique which gets in this development will be utilized greatly in good developments of the dot, the sight and the day/night riflescope system at the hereafter.

  • PDF

Resonant Type Wireless Power Transfer Using an Optimized Antenna at 1m Distance (1m 거리에서 최적화된 안테나를 통한 공진방식 무선전력전송)

  • Kim, Young Hyun;Ryu, Daun;Park, Daekil;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.3
    • /
    • pp.246-251
    • /
    • 2016
  • This paper has optimized WPT (wireless power transfer) antenna, and compared EM (electromagnetic) simulation result with measurement for the magnetic resonant type standard of A4WP (alliance for wireless power) using 6.78MHz frequency and 1m distance. Power transmission distance is affected by various factors such as system shape, antenna size, and resonator coil pitch etc, which were confirmed by the EM simulation. By simulation an optimized WPT antenna was designed for a fixed distance, and the transmission loss ${\mid}S_{21}{\mid}$ has been calculated with changing distance. Measurement was carried for the fabricated antenna, and the measured transmission loss is 1.5dB with 70% efficiency at maximum 1.3m distance compared to the simulated loss of 1.6dB with 69% efficiency

Effects of Specimen Shape on Hydration Heat and Autogenous shrinkage at an early (시험체 형상에 따른 고강도 콘크리트의 수화열 및 자기수축 초기특성 분석)

  • Lee, Eui-Bae;Koo, Kyung-Mo;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.915-918
    • /
    • 2008
  • Hydration heat and autogenous shrinkage are generated essentially by the same hydration. Many researchers have studied the close relationship between hydration temperature and autogenous shrinkage but hardly any research has been undertaken to explain the specific numerical relation. In this study, early age properties of hydration heat and autogenous shrinkage of specimen whose section size was changed were analyzed, and relationship between hydration heat and autogenous shrinkage was investigated. In the results of the study, inner temperature and autogenous shrinkage increased as the section size increased. And rise and rise ratio of hydration temperature and autogenous shrinkage in hydration heating section and autogenous shrinking section are increased too. Temperature rise and autogenous shrinkage rise increased respectively, as hydration heating velocity and autogenous shrinking velocity increased. And autogenous shrinkage rise and autogenous shrinking velocity increased as hydration heating velocity increased.

  • PDF

Nonlinear Distortion Analysis of 2.4GHz Power Amplifier for IEEE 802.11g OFDM Wireless LAN (IEEE 802.11g OFDM 무선랜용 2.4GHz 전력증폭기의 비선형 왜곡분석)

  • Oh Chung Gyun;Choi Jae Hong;Koo Kyung Heon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.3 s.333
    • /
    • pp.39-44
    • /
    • 2005
  • The OFDM modulation and transmission block have been modeled in order to analyse the relationship between the 2.4GHz power amplifier distortion and output ACPR for the IEEE 802.11g wireless LAN. The nonlinear characteristic of the power amplifier has been modeled as AM-to-AM and AM-to-PM using the behavioral model, and the output spectrum is analysed with the phase distortion variation. Also, amplifier back-off value from P1dB to satisfy the required IEEE 802.11g standard spectrum mask s been simulated with modeled phase distortion, and the simulation data have been compared to the measured result by using the pre-distortion technique.

Experimental infection of Paragonimus iloktsuenensis to albino rats, dogs and cats (흰쥐, 개 및 고양이의 이락촌폐흡충 감염 실험)

  • 이순형;구경회
    • Parasites, Hosts and Diseases
    • /
    • v.27 no.3
    • /
    • pp.197-202
    • /
    • 1989
  • This study was performed to observe the susceptibility of dogs and cats as definitive hosts of Paragonimus ilektsuenensis. The metacercariae of this luke were obtained from Sesarma dehaani collected at a focus near the mouth of Sumjin river in November, 1986 and February, 1987. The larvae isolated from the crabs were introduced Per os into 7 albino rats, 2 dogs and 3 cats. The adults were recovered from the experimental animals, End they were morphologically observed and measured. The results were as follows: 1. The recovery rate of adult worms at 42 days after infection was 53.3% from three albino rats, 21.0% from a dog and 12.7% from two cats. Most of the worms were recovered from the worm capsules in the lungs. 2. The size of worms recovered from albino rats, a dog, and cats 42 days after infection aver-aged $6.3{\times}3.2mm,{\;}6.3{\times}3.0mm,{\;}or{\;}6.2{\times}3.5mm$, respectively. There were little differences in the morphology of worms by different experimental animals. 3. The size of eggs from a dog was $88.9{\times}49.3{\mu\textrm{m}}$, and that from cats was $84.3{\times}53.7{\mu\textrm{m}}$ on average. Dogs and cats were good definitive hosts of p. iloktsuenensis. This fact suggests that human infection by this luke may be possible if the metacercariae were ingested.

  • PDF

Characteristics of Glutinous Rice Fractions and Improvement of Yoogwa Processing by Microparticulation/Air-classification (찹쌀의 초미세분쇄/공기분급 특성과 유과제조공정 개선)

  • Park, Dong-June;Ku, Kyung-Hyung;Mok, Chul-Kyoon
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.1008-1012
    • /
    • 1995
  • Glutinous rice was microparticulated and air-classified at different air classifying wheel speeds (ACWS) of 20,000 rpm and 15,000 rpm in a Turboplex classifier. The starch was concentrated to a coarse fraction and the protein was shifted to a fine fraction. The degree of starch damage of the coarse fraction was comparable to that of traditionally soaked glutinous rice. Yoogwa(Korean cracker) made from the fractions of $ACWS\;15,000{\sim}20,000\;rpm$ and below ACWS 15,000 rpm was very comparable to that made by the traditional method in degree of puffing, hardness and internal structure. It was also confirmed by the sensory evaluation, indicating that the microparticulation/air classification technology could be applied to produce raw material of Yoogwa. The developed noble process could exclude the long soaking step in the traditional Yoogwa process and reduce the pretest time remarkably.

  • PDF