• Title/Summary/Keyword: 구강건조

Search Result 191, Processing Time 0.032 seconds

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS (수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가)

  • Lee, Eun-Hye;Choi, Hang-Moon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.188-197
    • /
    • 2010
  • The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts. Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany) The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of $10{\times}10$ pixel and compared in mm Al equivalent at five points. Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken. We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area. The following results were obtained. 1. Each post system showed various radiopacity. 2. There was change of discriminability between each post and simulated specimens regardless of examiner. Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.

Influence of Parotid from Various Dose Rate in Intensity Modulated Radiation Therapy Planning for Head and Neck Cancer (두경부암 세기변조방사선치료 계획 시 선량율 변화가 이하선에 미치는 영향)

  • Hong, Joo-Wan;Jeong, Yun-Ju;Won, Hui-Su;Chang, Nam-Jun;Choi, Ji-Hun;Seok, Jin-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2010
  • Purpose: There are various beam parameter in intensity modulated radiation therapy (IMRT). The aim of this study is to investigate how various dose rate affect the parotid in treatment plan of IMRT. Materials and Methods: The study was performed on 10 nasopharyngeal carcinoma patients who have undergone IMRT. CT images were scanned 3 mm of thickness in the same condition and the treatment plan was performed by Eclipse (Ver.7.1, Varian, Palo Alto, USA). The parameters for planning used 6 MV energy and 8 beams under the same dose volume constraint. The variation of dose rates were used 300, 400, 500 MU/min. The mean dose of both parotid was accessed from the calculated planning among the 10 patients. The mean dose of parotid was verificated by 2D diode array (Mapcheck from Sun Nuclear Corporation, Melbourne, Florida). Also, Total monitor unit (MU) and beam-on time was analysed. Results: According to the dose rate, the mean dose of parotid was increased by 0.8%, 2.0% each, when dose rate was changed from 300 MU/min to 400, 500 MU/min, moreover Total MU was increased by 5.4% and 10.6% each. There was also a dose upward trend in the dose measurement of parotid by 2D diode array. However, beam - on time difference of 1~2 minutes was no signigicant in the dose rate increases. Conclusion: From this study, when the dose rates increase, there was a signigicant increase of Total MU and the parotid dose accordingly, however the shortened treatment time was not significant. Hence, it is considered that there is a significant decrease of late side effect in parotid radiation therapy, if the precise dose rate in IMRT is used.

  • PDF

The Optimal Radiation Dose in Localized Head and Neck Diffuse Large Cell Lymphoma (국한성 두경부 대세포성(Diffuse Large Cell) 림프종의 적정 방사선 조사선량)

  • Koom Woong Sub;Suh Chang Ok;Kim Yong Bae;Shim Su Jung;Pyo Hongryull;Roh Jae Kyung;Chung Hyun Cheol;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.303-308
    • /
    • 2002
  • Purpose : To determine the optimal radiation dose in a localized non-Hodgkin's lymphoma of the head and neck in the treatment setting for combined chemoradiotherapy. Materials an Methods :Fifty-three patients with stage I and II diffuse large ceil non-Hodgkin's lymphoma of the head and neck, who were treated with combined chemoradiotherapy between 1985 and 1998 were retrospectively reviewed. The median age was 49 years, and the male-to-female ratio was approximately 1.6. Twenty-seven patients had stage 1 disease and 26 had stage II. Twenty-three patients had bulky tumors $(\geq5\;cm)$ and 30 had non-bulky tumors (<5 cm). The primary tumors arose mainly from an extranodal organ $(70\%)$, most cases involving Waldeyer's ring $(90\%)$. All patients except one were initially treated with $3\~6$ cycles of chemotherapy, which was followed by radiotherapy. Radiation was delivered either to the primary tumor area alone $(9\%)$ or to the primary tumor area plus the bilateral neck nodes $(91\%)$ with a minimum dose of 30 Gy $(range\;30\~60\;Gy)$. The failure patterns according to the radiation field were analyzed, and the relationship between the dose and the in-field recurrence was evaluated. Results : The 10-year overall survival and the 10-year disease free survival rates were similar at $75\%\;and\;76\%$, respectively. A complete response (CR) after chemotherapy was achieved in 44 patients $(83\%)$. Subsequent radiotherapy showed a CR in all patients. Twelve patients $(23\%)$ had a relapse of the lymphoma after the initial treatment. Two of these patients had a recurrence inside the radiation field. No clear dose response relationship was observed and no significant prognostic factors for the in-field recurrences were identified because of the small number of in-field recurrences. However, for patients with tumors <5 cm in diameter, there were no in-field recurrences after a radiation dose 30 Gy. The 2 in-field recurrences encountered occurred in patients with a tumor $\geq5\;cm$. Conclusion .A dose of 30 Gy is sufficient for local control in patients with a non-bulky (<5 cm), localized, diffuse large cell non-Hodgkin's lymphoma when combined with chemotherapy. An additional boost dose in the primary site is recommended for patients with bulky tumors $(\geq5\;cm)$.

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.

Clinicostatistical Analysis for 53 Cases which were performed Microlaryngeal Surgery under Suspension Laryngoscope (Suspension Laryngoscope 하에 후두미세 수술을 시행한 53명에 대한 임상통계학적 고찰)

  • 전하동;최인환;추광철;김선곤
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1979.05a
    • /
    • pp.6.3-7
    • /
    • 1979
  • During last two. decades, microlaryngeal surgery opened now era in the laryngeal surgery. In 1960, using Lynch's suspension laryngoscope, Seal co et al performed the first successful microsurgery in the treatment of polyp and other laryngeal diseases. In 1968, Kleinsasser reported a new technique of microlaryngeal surgery with a self retaining laryngoscope. Authors studied the statistic analysis of 53 cases (75 times) of the suspension laryngoscopic microsurgery at E.N.T. department of Han Yang University Hospital from May 1972 to April 1979 an reported this result. 1) sex distribution was male 1.3 : female 1. 2) age distribution was 3rd decade 14 cases (26.4%), 2nd decade 10 cases (18.7%) and 5th decade 9 cases (17%) in order. 3) chief compliant was hoarseness 48 cases (90.6%), dyspnea 16 cases (30.5%) and sore throat 8 cases (15.1%) in order. 4) diagnostic impression was polyp 18 cases (34%), nodule 12 cases (22.6%), papilloma 9 cases (17%), tumor 7 cases (13.2%), intubation granuloma 3 cases (5.7%) in order and other kinds were laryngeal stenosis with decannulation difficulty, laryngeal paralysis and hematoma. 5) histopathologic result of 48 cases was polyp 17 cases (35.4%), papilloma 11 cases (23%), nodule 9 cases (18.9%), malignancy 3 cases (6.3%), chronic inflammation 2 cases (4.2%) in order and others were hyperkeratosis, mucous retension cyst, nodule associated abscess, granuloma, hematoma and unconfirmed case. 6) in involved site, both sides 15 cases (60%), Lt.side 5 cases (19%), Rt side 3 cases (12%), anterior commissure 3 cases (12%) on the nodule and polyp (26 cases) and whole laryngeal involvement 7 cases (63.6%), one side cord involement 3 cases (23.7%), extralaryngeal involvement 1 cases (9.1%) on the papilloma (11 cases).

  • PDF

Application of Noninvasive Positive Pressure Ventilation in Patients with Respiratory Failure (호흡부전 환자에서 비침습적 양압환기법의 적용)

  • Seol, Young Mi;Park, Young Eun;Kim, Seo Rin;Lee, Jae Hyung;Lee, Su Jin;Kim, Ki Uk;Cho, Jin Hoon;Park, Hye Kyung;Kim, Yun Seong;Lee, Min Ki;Park, Soon Kew;Kim, Young Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.26-33
    • /
    • 2006
  • Background: Noninvasive positive pressure ventilation(NPPV) has been increasingly used over the past decade in the management of acute or chronic respiratory failure and weaning of mechanical ventilation. We performed this clinical study to evaluate the usefulness of NPPV in patients who developed acute respiratory failure or post-extubation respiratory failure. Methods: We analysed thirty four patients(sixteen males and eighteen females, mean ages 58 years) who applied NPPV(BIPAP S/T, Respironics co., USA) for respiratory failure or weaning difficulty at medical intensive care unit(MICU), emergency room and general ward of a tertiary hospital. We evaluated the underlying causes of respiratory failure, duration of treatment, the degree of adaptation, complication and predictive parameters of successful outcome. Results: The overall success rate of NPPV was seventy-one percent. The duration of NPPV applying time, baseline blood pressure, pulse rate, respiration rate, $PaO_2$, $PaCO_2$, $SaO_2$ were not different between success group and failure group. But, the baseline pH was higher in the success group. Predictors of success were higher baseline pH, patients with underlying disease of COPD, improvement of vital sign and arterial blood gas value after NPPV application. The success rate in patients with post-extubation respiratory failure was eighty percent. There were no serious complication on applying NPPV except minor complications such as facial skin erythema, abdominal distension & dry mouth. Conclusion: NPPV may be effective treatment in patients with acute respiratory failure or post-extubation respiratory failure in selected cases.

ABRASION AND CHEMICAL DEGRADATION OF LIGHT-CURED COMPOSITE RESIN FOR UPDATED RESIN DEVELOPMENT (차세대 레진개발을 위한 광중합형 복합레진의 마모와 화학적 분해)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Yook, Geun-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.685-695
    • /
    • 2004
  • The aim of this study was to evaluate the resistance to degradation and to compare the wear resistance characteristics of four composite resins in an alkaline solution. The resistance to degradation was evaluated on the basis of mass loss(%), degradation depth(${\mu}m$), Si loss(ppm) and wear depth. The brands studied were Heliomolar flow, Filtek supreme, Point4, Tetric flow. The results were as follows: 1. The sequence of the mass loss was in descending order by Heliomolar flow, Filtek supreme, Point4, Tetric flow. There was significant differences among the materials except Heliomolar flow and Filtek supreme. 2. The sequence of the degree of degradation layer depth was in descending order by Filtek supreme, Heliomolar flow, Tetric flow, Point4. There were significant differences among the materials except Heliomolar flow and Tetric flow. 3. The sequence of Si loss was in descending order by Filtek supreme, Heliomolar flow, Point4, Tetric flow. There were significant differences among the materials except Point 4 and Tetric flow. 4. The sequence of maximum wear depth was in descending order by Heliomolar flow, Point4, Fillet supreme, Tetric flow and there was increasing wear depth on soaking in 0.1N NaOH solution. 5. When observed with SEM, destruction of bonding between matrix and filler was observed and when observed with CLSM, the depth of degradation layer of specimen surface was observed. There results indicate that wear and hydrolytic degradation could be considered to be evaluation factors of composite resins.

  • PDF

The Effect of Temporary Cement Cleaning Methods on the Retentive Strength of Cementation Type Implant Prostheses (임시 시멘트 제거방법이 시멘트 유지형 임플란트 보철물의 유지력에 미치는 영향)

  • Shin, Hwang-Kyu;Song, Young-Gyun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.125-140
    • /
    • 2011
  • The remnant of temporary cement on the intaglio surface of cast restoration may have a negative effect on the retentive strength of permanent cement. This study was to evaluate the effect of temporary cement cleaning methods on the retentive strength of cementation type implant prostheses. Prefabricated implant abutments - height 5.5mm, diameter 4.5mm, 6 degree axial wall taper with chamfer margins were used. Forty copings-abutment specimens were divided into four groups(each n=10) according to the cleaning methods for temporary cement(Temp-$Bond^{(R)}$) as follows : no temporary cementation(the control group), orange solvent, ultrasonic cleaning, air borne-particle abrasion. After the application of temporary cement and the separation, the cleaning procedure was performed according to the protocol of each group. The specimens were cemented with $Premier^{(R)}$ Implant $Cement^{TM}$. After the permanent cementation, the specimens were subjected to thermocycling and pulled out from the specimens with a universal testing machine at a cross-head speed of 0.5mm/min. After the retentive strength test, all the specimens were cleaned using ultrasonic cleaning, abraded with air borne-particles, and steam-cleaned. Likewise, the specimens were temporarily cemented(Temp-$Bond^{(R)}$ NE), cleaned according to the protocol of each group, cemented with $Premier^{(R)}$ Implant $Cement^{TM}$ and subjected to thermocycling and measurement of their retentive strength. The mean of group with orange solvent were significantly lower than those of other groups(p<0.05). There was no significance between group with ultrasonic cleaning and group with air borne-particle abrasion. Group with ultrasonic cleaning and group with air-particle abrasion were no significance at control group. There was no significance between group cemented with Temp-$Bond^{(R)}$ and group cemented with Temp-$Bond^{(R)}$ NE. Within the limitation of this study, it can be concluded that the temporary cement cleaning method with only orange solvent may have a negative effect on the retentive strength of permanent cement. Ultrasonic cleaning and air borne-particle abrasion methods are recommended for the temporary cement cleaning method on cementation type implant prostheses.

Preliminary Results of Phase I/II Study of Simultaneous Modulated Accelerated (SMART) for Nasopharyngeal Carcinoma (비인강암의 치료에서 동시차등조사가속치료를 적용한 제1상/2상 연구의 예비적 결과)

  • Park Jin-Hong;Back Geum-Mun;Yi Byong-Yong;Choi Eun-Kyung;Ahn Seung-Do;Shin Seong-Soo;Kim Jung-Hun;Kim Sang-Yoon;Lee Bong-Jae;Nam Soon-Yuhl;Choi Seung-Ho;Kim Seung-Bae;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.1-10
    • /
    • 2006
  • Puroose: To present preliminary results of intensity-modulated radiotherapy (IMRT) using the simultaneous modulated accelerated radiation therapy (SMART) boost technique in patients with nasopharyngeal carcinoma (NPC). Materials and Methods: Twenty patients who underwent IMRT for non-metastatic NPC at the Asan Medical Center between September 2001 and December 2003 were prospectively evaluated. IMRT was delivered using the 'step and shoot' SMART technique at prescribed doses of 72 Gy (2.4 Gy/day) to the gross tumor volume (GTV), 60 Gy (2 Gy/day) to the clinical target volume (CTV) and metastatic nodal station, and 46 Gy (2 Gy/day) to the clinically negative neck region. Eighteen patients also received concurrent chemotherapy using cisplatin once per week. Results: The median follow-up period was 27 months. Nineteen patients completed the treatment without interruption; the remaining patient interrupted treatment for 2 weeks owing to severe pharyngitis and malnutrition. Five patients (25%) had RTOG grade 3 mucositis, whereas nine (45%) had grade 3 pharyngitis. Seven patients (35%) lost more than 10% of their pretreatment weight, whereas 11 (55%) required intravenous fluids and/or tube feeding. There was no grade 3 or 4 chronic xerostomia. All patients showed complete response. Two patients had distant metastases and loco-regional recurrence, respectively. Conclusion: IMRT using the SMART boost technique allows parotid sparing, as shown clinically and by dosimetry, and may also be more effective biologically. A larger population of patients and a longer follow-up period are needed to evaluate ultimate tumor control and late toxicity.