• Title/Summary/Keyword: 교합면 두께

Search Result 99, Processing Time 0.028 seconds

INTRA-ALVEOLAR TRANSPLANTATION OF COMPLETELY CROWN-ROOT FRACTURED TOOTH WITH DEMINERALIZED FREEZED DRIED BONE GRAFT (치은연 하방으로 파절된 치아의 탈회냉동건조골을 이용한 Intra-alveolar transplantation)

  • Lim, Hyoung-Soo;Kim, Dong-Phil;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.344-350
    • /
    • 2000
  • Incidence of crown-root fracture due to traumatic injury, have been reported 3% in the permanent dentiton, 2% in the deciduous dentition. There are two treatment methods for crown-root fractured teeth with pulp exposure, when the fracture line was located under the alveolar crest. One way is the extrusion by orthodontic force the other way is intra-alveolar transplantation which occlusally repositioning of apical fragment in the alveolar socket. Since intra-alveolar transplantation has introduced in 1970s, it was practiced as alternative to orthodontic extrusion. As the result, this method may thoughted that had a good prognosis. As a result of trauma, completely crown-root fracture was occured in the maxillary right central incisor in this case. We couldn't reposition the deepest fracture line above the alveolar crest by the conventional surgical extrusion, because apical fragment was too short. Thus, after extraction of apical fragment, we repositioned it to the socket following demineralized freezed dried bone graft, which possible to support the apical fragment. At the 15-month recall examination, the root still showed normal mobility and there was not observed any in flammatory or replacement root resorption in the periapical radiograph.

  • PDF

A STUDY ON THE MICROLEAKAGE OF PIT AND FISSURE SEALANTS WITH DIFFERENT FILLING AMOUNT (치면열구전색재의 충전량에 따른 미세누출의 비교연구)

  • Park, Soo-Jin;Jung, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.238-244
    • /
    • 2003
  • With the purpose of evaluating the effect of ailing amount of pit and assure sealants on the microleakage, 6 groups of specimens with different filling amount, filling materials and surface pretreatment were investigated. Sixty permanent third molars were divided into three groups. The occlusal surface of each tooth was divided into two parts; the filing width of one part was below 1mm (group1, 3, 5), and in the other part more than 2mm (group 2, 4, 6) Group 1 and 2: Helioseal F was applied directly to etched enamel; Group 3 and 4: Helioseal F was applied to etched and scotchbond Multi-purpose plus pre-treated enamel; Group 5 and 6: Tetric Flow was applied. After 500 times thermocycling and dye infiltration, we evaulated the microleakage. The results were as follows; 1. The mean microleakage score at each width were increased in the following order;group 5<3<1, and group 6<4<2. 2. In comparing the groups with same material and surface pretreatment but with different filling width (group 1 versus 2, 3 versus 4, 5 versus 6), the microleakage scores were significantly different. 3 The microleage was affected by filling amount of pit and assure sealants than Oiling materials and dentin bonding agent pretreatment.

  • PDF

Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture (변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향)

  • Yun, Mi-Jung;Yoon, Min-Chul;Eom, Tae-Gwan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing.

Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study (네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석)

  • Jeon, Sang-Je;Park, Jeong-Kil;Kim, Hyeon-Cheol;Woo, Sung-Gwan;Kim, Kwang-Hoon;Son, Kwon;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.359-370
    • /
    • 2006
  • The objective of this study was to investigate the effect of excessive occlusal loading on stress distribution on four type of cervical lesion, using a three dimensional finite element analysis (3D FEA). The extracted maxillary second premolar was scanned serially with Micro-CT. The 3D images were processed by 3D-DOCTOR. ANSYS was used to mesh and analyze 3D FE model. Four different lesion configurations representative of the various types observed clinically for teeth were studied. A static point load of 500N was applied to the buccal and lingual cusp (Load A and B). The principal stresses in lesion apex, and vertical sectioned margin of cervical wall were analyzed. The results were as follows 1. The patterns of stress distribution were similar but the magnitude was different in four types of lesion 2. The peak stress was observed at mesial corner and also stresses concentrated at lesion apex. 3. The compressive stress under load A and the tensile stress under load B were dominant stress. 4. Under the load, lesion can be increased and harmful to tooth structure unless restored.

Is there any determinant for successful distraction osteogenesis of the mandible in hemifacial microsomia patients? (반안면왜소증 환자의 하악골 신장술시 치료결과의 차이에 기여하는 인자)

  • Baek Seung-Hak
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.7 no.2
    • /
    • pp.77-91
    • /
    • 2004
  • 본 연구의 목적은 반안면왜소증 환자의 하악골 신장술시 초기 치아골격 특성들 중에서 치료결과의 차이에 기여하는 인자를 찾는 것이다. 치료전의 치아골격 특성, 골신장술의 효과와 그 유지상태를 관찰하기 위하여 골신장술 직전(T0), 직후(T1), 추적 2년후(T2)에 측모와 정모 두부방사선 계측사진을 촬영하여 전후방, 수직치아, 비대칭 항목들을 계측하였다. T2 시기의 계측 결과에 따라서 환자들을 1군(양호군, 10명)과 2군(불량군, 9명)으로 분류하였다. 두 군에서 각 시기와 T0-T1, T1-T2 동안의 변화량의 차이를 Mann-Whitney U test, Wilcoxon signed independent t-test, rank test, ANOVA test를 사용하여 분석하였다. pruzansky type이 골신 장술의 성공과 실패 여부와 관계가 깊게 나타났다. T0 시기에 2군은 1군에 비하여 하악골이 후방위치되었고, 하악지 고경(ramus height)이 짧았고, 하악각(gonial angle)이 컸으며, 이환측 하악지가 내측경사되었고, 이환측으로의 이부변위(chin point deviation)가 크게 나타났다. 1군에서 골신장술의 주요한 효과는 하악지 고경의 증가, 하악골의 전방위치, 하악각의 증가, articular angle의 감소에 따른 하약골의 반시계방향 회전, 이환측의 하악지 경사의 증가, 교합면경사와 이부변위의 개선으로 나타났다. 그러나 2군에서는 골신장술을 시행했을 때 1군에 비하여 하악골이 시계방향으로 회전되었고 하악지 고경의 증가량이 작게 나타났다. T2 시기에 2군에서는 하악골의 반시계방향 회전이 나타났고, 하악지 성장이 일어나지 않았으나, 1군은 반대의 경향을 보였다. 이러한 인자들이 골신장술 결과의 차이에 기여하는 것으로 생각된다.

  • PDF

Comparative study in marginal fit of a pressed ceramic and feldspathic porcelain fused to metal restoration (열-가압을 이용한 금속 도재관과 전통적인 금속 도재관의 변연 적합도 비교 연구)

  • Kim, Yoon-Young;Park, Won-Hee;Yoo, Dong-Yeob;Lee, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.273-279
    • /
    • 2010
  • Purpose: The purpose of this in vitro study was to compare the marginal adaptation of a ceramic-pressed-to-metal restoration with traditional metal-ceramic restoration. Materials and methods: Duplicating the prepared resin tooth, 20 metal dies were fabricated. Twenty metal copings of 2 groups which were metal ceramic restoration and pressed to metal restoration were fabricated. The marginal opening of each coping was measured with Microscope (BX 60M-36E $41D^{(R)}$: Olympus, Japan). After porcelain build-up, the marginal opening of metal ceramic restoration and pressed to metal restoration ($PoM^{(R)}$: Ivoclar vivadent., Liechtenstein) were also evaluated in the same method. The measurements were analyzed using Wilcoxon Signed Ranks test and Mann-Whitney U test. Results: Within the limits of this study, the results were as follows. 1. Metal-ceramic restorations in coping state ($64.93{\pm}12.48\;{\mu}m$) in compared with Metal ceramic restorations after porcelain build-up ($63.43{\pm}12.86\;{\mu}m$) had no significant difference in marginal adaptation. 2. Pressed-metal-ceramic restorations in coping state ($50.00{\pm}12.28\;{\mu}m$) in compared with Pressed metal ceramic restorations after porcelain build-up ($56.72{\pm}13.80\;{\mu}m$) had no significant difference in marginal adaptation. 3. Metal-ceramic restorations in compared Pressed-metal-ceramic restorations had no significant difference in marginal adaptation. Conclusion: Pressed-metal-ceramic restorations have the advantage of being technically less change through using of the lost-wax technique and this allows for the convenience of a full-contour ceramic wax-up as opposed to the more technique-sensitive layering method. Pressed-metal-ceramic restorations may be considered in clinic on the basis of the result of this study and the advantage of this system.

Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph (성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교)

  • Jang, Min-Guk;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.312-323
    • /
    • 2011
  • Objective: This study compared the bone thickness of the palate between lateral cephalogram and 3D model measurements. Methods: The subjects consisted of 30 adults (15 men,15 women) with a normal skeletal pattern and occlusion. The CT images were transformed to a 3D model, and were compared with the cephalometric image. Descriptive statistics for each variable were calculated. Results: In the 3D CT model, the mid-palatal area was the thickest part. It became thinner as the palate tapered laterally. In the male group, the thinnest portion was positioned 6 mm away from the mid-palate, while in the female group the thinnest portion was 8mm away from the mid-palate. Correlation analysis between the lateral cephalometric and 3D CT model revealed a significant correlation except in the mid palatal area and the area 2 mm lateral to the mid-palate in men, whereas there was a significant relationship in every area in the women. In both men and women, the highest correlation appeared in the area 8 mm lateral to the mid palate. Conclusions: Using regression analysis, an actual prediction of the bone thickness between the measured bone thickness of the lateral cephalometric radiograph and 3D model was made. This will provide useful information for mini-implant length selection when inserting into the palate.

QUANTITATIVE COMPARISON OF PERMEABILITY IN THE ADHESIVE INTERFACE OF FOUR ADHESIVE SYSTEMS (열순환 후 상아질 접착 계면의 수분 투과성 변화에 대한 정량적 분석)

  • Chang, Ju-Hea;Yi, Kee-Wook;Kim, Hae-Young;Lee, In-Bog;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • The purpose of this study was to perform quantitative comparisons of water permeable zones in both the adhesive and the hybrid layer before and after thermo cycling in order to assess the integrity of the bonding interface. Twenty eight flat dentin surfaces were bonded with a light-cured composite resin using one of four commercial adhesives [OptiBond FL (OP), AdheSE (AD), Clearfil SE Bond (CL). and Xeno III (XE)]. These were sectioned into halves and subsequently cut to yield 2-mm thick specimens; one specimen for control and the other subjected to thermocycling for 10,000 cycles. After specimens were immersed in ammoniacal silver nitrate for 24 h and exposed to a photo developing solution for 8 h, the bonded interface was analyzed by scanning electron microscopy (SEM) and wavelength dispersive spectrometry (WDS) at five locations per specimen. Immediately after bonding. the adhesive layer of OP showed the lowest silver uptake, followed by CL, AD. and XE in ascending order (p < 0.0001); the hybrid layer of CL had the lowest silver content among the groups (p = 0.0039). After thermocycling, none of the adhesives manifested a significant increase of silver in either the adhesive or the hybrid layer. SEM demonstrated the characteristic silver penetrated patterns within the interface. It was observed that integrity of bonding was well maintained in OP and CL throughout the thermocycling process. Adhesive-tooth interfaces are vulnerable to hydrolytic degradation and its permeability varies in different adhesive systems, which may be clinically related to the restoration longevity.

AN EXPERIMENTAL STUDY ON THE MICROTENSILE BONDING STRENGTH OF DENTIN TREATED BY $CARISOLV^{TM}$ ($Carisolv^{TM}$ 에 의한 우식제거후 Microtensile Bonding Strength에 관한 연구)

  • Baik, Byeong-Ju;Kwon, Byoung-Woo;Kim, Jae-Gon;Cheon, Cheol-Wan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.389-396
    • /
    • 2002
  • The purpose of this study was to compare the microtensile bonding strength of chemomechanically excavated dentin($Carisolv^{TM}$) to conventional caries removal(bur). The following adhesive systems were used; AB: All-Bond 2(3M, USA), PB: Prime & Bond 2.1(Dentsply, DE), AQ: AQ Bond(sun medical, Japan). 42 human molars with occlusal caries were assigned to 6 groups. Sequential caries removal was controlled with laser fluorescence. Each group was devided as follows; group A, B, C were $Carisolv^{TM}$ applied, group D,E,F were bur used. In group A and D, AB was used as a dentin adhesive. group B,E and group C,F was AQ and AQ was used each. The cavity was filled with composite resin(Z-100). The specimens were sectioned vertically into multiple serial 0.7 mm thick slabs. And then those slabs were sectioned into rectangular parts under 0.7 mm width. Finally 0.7-1.0 mm a right hexahedron shape stick become. Microtensile bonding test was carried out with testing apparatus at cross-head speed of $0.5\;mm/min^{-1}$ and fractured surfaces were observed with scanning electron microscope(JSM-6400, Jeol, Japan). The obtained results were summarized as follows ; 1. In the group of caries removal with $Carisolv^{TM}$, micro-tensile bonding strength decreased to $75.8{\sim}80$ percent of bur used group. 2. In the group of caries removal with $Carisolv^{TM}$, decreased degree of micro-tensile bonding strength is not so different in 3 kinds of dentin adhesives(p<0.05). 3. In the group of caries removal with $Carisolv^{TM}$, microtensile bonding strength of AB, PB, AQ was 32.6MPa(2.4), 30.1Mpa (1.8), 21.2Mpa(1.9). 4. In the group of caries removal with Bur and $Carisolv^{TM}$, microtensile bonding strength of AQ was significantly lower than that of AB and PB(p<0.01).

  • PDF

The Effect of Fuctional Lateral Shift of Mandible on the Growth of Mandible in Growing Rats (백서 하악골의 기능적 측방편위가 하악골 성장에 미치는영향)

  • PARK, Kwan-Sik;KYUNG, Hee Moon;SUNG, Jae Hyun
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.105-117
    • /
    • 1997
  • This investigation examined the effect of lateral shift of mandible from functional occlusal interference on the growth of mandible and the growth pattern of mandible shown after the removal of occlusal interference. The followings were performed with the results below : the changes in mandible and condylar cartilage were studied in the experimental group with upper right, lower left incisors cut for 2 and 4 weeks- an 4-week-old rats and the experimental group which had cut for 4 weeks and suspended for 2 weeks. 1. In the 2-week experimental group, the left mandibular length, condylar length, mandibular height and condylar area seemed smaller than those on the right and the normal group ; the right mandibular length and condylar area were smaller than the normal group. 2. In the 4-week experimental group, left condylar area was smaller than the right, but due to the quick changes in adaptability of left mandible, right and left mandibular lengths were similar. compared with the normal group, however, mandibular length and condylar area still remained small. 3. In the 6-week experimental group, the left and the right appeared similar with the mandibular length remaining still shorter than the normal group. 4. In the sagittal plane, the proliferation of the cartilage layers of the left condylar cartilage of the 2-week group appeared to have general repression compared with the right and the normal group. The right side also showed repressed growth compared with the normal group. In the 4 and 6-week groups, however, it was similar to the normal group. 5. In condylar cartilage volume, no significant difference was noted in the comparisions of left and right of the experimental group, nor in the comparison of the same sides of experimental wand normal groups. Based on the above, in case of contralateral incisal cutting in rats, it was observed that the growth of mandible and condyle of the cutting side was repressed, at the same time, the quick adaptability led to similar changes of growth in left and right mandibles. But judging from the similar phenomena throughout the whole experimental period in the changes of condylar cartilage volume in the experimental, right and left, and normal groups, the general overall growth of condylar cartilage was found unrepressed. It was also recognized that the growth of condylar cartilage can take in various directions.

  • PDF