• Title/Summary/Keyword: 교정 메커니즘

Search Result 8, Processing Time 0.025 seconds

Performance Verification of Deploy/Stow-type Calibration Mechanism with Dual-function of Launch Locking and Fail-Safe (단일장치로 발사환경구속 및 결함안전기능이 가능한 전개수납형 교정 메커니즘의 기능검증)

  • Lee, Myeong-Jae;Kim, Tae-Gyu;Jo, Mun-Shin;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.895-903
    • /
    • 2016
  • Spaceborne imaging sensors require periodic calibrations using an on-board calibration device for an image quality of observation satellites. The on-board calibration device consists of a blackbody to provide uniform radiance temperatures and calibration mechanism with a function of stow and deploy to target the blackbody during the calibration. Among these devices, the calibration mechanism is required to implement a fail-safe function to prevent blocking of the main optical path when the mechanism stops at a certain position during on-orbit calibration. In addition, structural safety of the mechanical driving part of the mechanism within the launch environment must be guaranteed. In this study, we proposed a deploy/stow-type calibration mechanism that provides launch-lock and fail-safe function. The effectiveness of the functionality of the proposed mechanism was validated through functional test using engineering model.

Detection and Correction of Erroneous Positioning Data With Moving Window Mechanism (이동 윈도우 메커니즘을 이용한 위치데이터 오류 검출 및 교정)

  • On, Kyoung-woon;Song, Ha Yoon;Kim, Hyunuk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1273-1276
    • /
    • 2012
  • 오늘날 모바일 스마트 기기의 발전은 위치기반의 새로운 기술을 이끌었다. 현재 위치 데이터를 사용하는 많은 응용프로그램들이 소개되었고, 또한 널리 사용되고 있다. 하지만 아직 이러한 위치 데이터들은 환경적인 요소 등으로 인해 오류가 많다. 본 논문에서는 연속적인 위치 데이터들 사이에서 오류를 찾아내는 알고리즘을 제안할 것이다. 이동 윈도우에서의 이동 평균과 이동 표준편차가 이동 유의구간을 구성할 것이고, 이 이동 유의 구간은 오류 데이터들을 찾아내는 데에 사용될 것이다. 또한 오류 데이터를 교정하는 방식도 제안할 것이다. 이러한 일련의 과정을 본 논문에서는 알고리즘으로 나타낸 후 실험을 통해 입증할 것이다. 이러한 방식의 접근이 다른 위치기반 응용프로그램이나 인간 이동 연구에 도움이 될 것이라 생각한다.

Effect of Parameters for Real-time Measurement of Nano Aerosols (나노 에어로졸의 실시간 측정에 영향을 미치는 인자)

  • 지준호;노형수;오상경
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2004.11a
    • /
    • pp.117-118
    • /
    • 2004
  • 에어로졸의 측정은 다양한 변수에 영향을 받는다. 입자가 공기 중에 떠 있으므로 입자 주위의 유체온도와 압력에 영향을 받을 뿐 아니라 측정 대상인 입자의 크기, 농도, 하전 상태에 따라서 제약을 받는다. 특히, 에어로졸의 발생이나 측정은 복잡한 메커니즘으로 이루어지기 때문에 장비의 성능을 평가하거나 교정하는 과정은 쉽지 않고, 적당한 지침이나 문헌 또한 부족한 실정이다. 고농도, 고하전인 극한 조건에서 나노 에어로졸 입자를 측정하는 경우에는 측정 장비가 신뢰성 있는 결과를 제공할 수 있도록, 측정 대상인 나노 입자의 하전량, 형상, 크기 분포를 미리 예측하여 SMPS의 운전조건을 적절하게 결정할 수 있도록 미리 확인해야 한다

  • PDF

Implementation on the Portable Blood Gas Analyzer and Performance Estimation (휴대형 혈액가스분석 시스템의 구현 및 성능평가)

  • Jeong, Do-Un;Jeon, Gye-Rok;Bae, Jin-Woo;Kim, Gil-Jung;Sim, Yoon-Bo
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.34-43
    • /
    • 2003
  • In this study, we implemented the measurement of pH, $pO_2$, $pCO_2$ of the arterial blood on a portable blood gas analysis system. This system is consist of two parts of hardware and software. The hardware part is divided into a fluidic mechanism and an electronic circuit unit. The system program is composed of operating, washing, correcting, and measuring routines. Both of 1-point and 2-point calibration schemes were used to enhance the accuracy of the measurement. In order to evaluate the performance of the developed system, we measured and performed statistical analysis on the characteristics of the sensing electrode response. As a result, coefficient variation was within 1.12, and maximum error was within 1.298%. We confirmed development possibility of portable blood gas analyzer.

Development of a Braille Translation and Document Summarization System for the Visually Impaired Education (시각장애인 교육용 점자 번역 및 문서요약 시스템 개발)

  • Hee-Jin Kim;Bo-Yeong Park;Eun-Ju Park;Ji-Hae Jeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.11a
    • /
    • pp.969-970
    • /
    • 2023
  • 본 연구는 기존의 점자 교육 및 번역 서비스의 한계를 극복하기 위해 16가지의 다양한 번역 메커니즘과 문서 요약 기능을 제공하여 시각장애인의 학습자료의 접근성을 향상한다. 점역사의 번역 작업을 자동화하여 정확하고 빠른 점역 및 교정을 지원한다. 음성파일을 제공하여 시각장애인의 학습 시간을 단축할 수 있다. E-yes 는 시각장애인의 학습 효율을 높이고 학습자료 접근성 개선을 목적으로 한다.

Touch-Trigger Probe Error Compensation in a Machining Center (공작기계용 접촉식 측정 프로브의 프로빙 오차 보상에 관한 연구)

  • Lee, Chan-Ho;Lee, Eung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.661-667
    • /
    • 2011
  • Kinematic contact trigger probes are widely used for feature inspection and measurement on coordinate measurement machines (CMMs) and computer numerically controlled (CNC) machine tools. Recently, the probing accuracy has become one of the most important factors in the improvement of product quality, as the accuracy of such machining centers and measuring machines is increasing. Although high-accuracy probes using strain gauge can achieve this requirement, in this paper we study the universal economic kinematic contact probe to prove its probing mechanism and errors, and to try to make the best use of its performance. Stylus-ball-radius and center-alignment errors are proved, and the probing error mechanism on the 3D measuring coordinate is analyzed using numerical expressions. Macro algorithms are developed for the compensation of these errors, and actual tests and verifications are performed with a kinematic contact trigger probe and reference sphere on a CNC machine tool.

Factors influencing the axes of anterior teeth during SWA on masse sliding retraction with orthodontic mini-implant anchorage: a finite element study (교정용 미니 임플랜트 고정원과 SWA on masse sliding retraction 시 전치부 치축 조절 요인에 관한 유한요소해석)

  • Jeong, Hye-Sim;Moon, Yoon-Shik;Cho, Young-Soo;Lim, Seung-Min;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.339-348
    • /
    • 2006
  • Objective: With development of the skeletal anchorage system, orthodontic mini-implant (OMI) assisted on masse sliding retraction has become part of general orthodontic treatment. But compared to the emphasis on successful anchorage preparation, the control of anterior teeth axis has not been emphasized enough. Methods: A 3-D finite element Base model of maxillary dental arch and a Lingual tipping model with lingually inclined anterior teeth were constructed. To evaluate factors influencing the axis of anterior teeth when OMI was used as anchorage, models were simulated with 2 mm or 5 mm retraction hooks and/or by the addition of 4 mm of compensating curve (CC) on the main archwire. The stress distribution on the roots and a 25000 times enlarged axis graph were evaluated. Results: Intrusive component of retraction force directed postero-superiorly from the 2 mm height hook did not reduce the lingual tipping of anterior teeth. When hook height was increased to 5 mm, lateral incisor showed crown-labial and root-lingual torque and uncontrolled tipping of the canine was increased.4 mm of CC added to the main archwire also induced crown-labial and root-lingual torque of the lateral incisor but uncontrolled tipping of the canine was decreased. Lingual tipping model showed very similar results compared with the Base model. Conclusion: The results of this study showed that height of the hook and compensating curve on the main archwire can influence the axis of anterior teeth. These data can be used as guidelines for clinical application.

A Study on Various Sizes and Volumes of the Palate among the Korean Population in Mixed Dentition (한국 인구집단에서 부정교합 환아의 구개의 크기 및 용적에 관한 연구)

  • Jimyung, Choi;Jisun, Shin;Miran, Han;Junhaeng, Lee;Jongsoo, Kim;Jongbin, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.329-339
    • /
    • 2022
  • The purpose of this study was to compare the palatal dimensions (volume, width, length, and height) in different malocclusions (Class I, II, and III) in mixed dentition using a three-dimensional digital scanner. The study was performed on 30 selected casts from 1400 casts that were taken at the Department of Pediatric Dentistry at Dankook University. Casts consisted of Class I, II, and III malocclusion groups in Hellman's dental age IIIA. The mean age was 8 years and 6 months ± 11 months. Each cast was scanned by three-dimensional digital scanner, Medit T710 (Medit, Seoul, Korea), and shaped into the three-dimensional image and calculated palatal dimensions using the Plan T program (SMD solution, Seoul, Korea). The values were statistically compared and evaluated by Kruskal-Wallis followed by the Mann-Whitney test. According to our results, subjects with Class II malocclusion showed lower palatal width and longer palatal length compared to those with Class I and Class III. For palatal height, Class III malocclusion subjects in mixed dentition exhibited a larger number than Class II and Class I. Lastly, for palatal volume, compared to other malocclusions, Class III showed higher results; however, there were no significant differences. The form of the palate differs in types of malocclusions and understanding of these differences is important in clinical significance. Based on this study, the understanding of the relationship between the shape of the palate and the skeletal pattern provides useful information about orthodontic treatment plans, early diagnosis of malocclusion, and morphological integration mechanisms. Orthopedic treatment in the maxilla should be performed during early and intermediate mixed dentition to enhance treatment efficiency.