• Title/Summary/Keyword: 교정인자

Search Result 239, Processing Time 0.026 seconds

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Literature Analysis of Radiotherapy in Uterine Cervix Cancer for the Processing of the Patterns of Care Study in Korea (한국에서 자궁경부알 방사선치료의 Patterns of Care Study 진행을 위한 문헌 비교 연구)

  • Choi Doo Ho;Kim Eun Seog;Kim Yong Ho;Kim Jin Hee;Yang Dae Sik;Kang Seung Hee;Wu Hong Gyun;Kim Il Han
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.61-70
    • /
    • 2005
  • Purpose: Uterine cervix cancer is one of the most prevalent women cancer in Korea. We analysed published papers in Korea with comparing Patterns of Care Study (PCS) articles of United States and Japan for the purpose of developing and processing Korean PCS. Materials and Methods: We searched PCS related foreign-produced papers in the PCS homepage (212 articles and abstracts) and from the Pub Med to find Structure and Process of the PCS. To compare their study with Korean papers, we used the internet site 'Korean Pub Med' to search 99 articles regarding uterine cervix cancer and radiation therapy. We analysed Korean paper by comparing them with selected PCS papers regarding Structure, Process and Outcome and compared their items between the period of before 1980's and 1990's. Results: Evaluable papers were 28 from United States, 10 from the Japan and 73 from the Korea which treated cervix PCS items. PCS papers for United States and Japan commonly stratified into $3\~4$ categories on the bases of the scales characteristics of the facilities, numbers of the patients, doctors, Researchers restricted eligible patients strictly. For the process of the study, they analysed factors regarding pretreatment staging in chronological order, treatment related factors, factors in addition to FIGO staging and treatment machine. Papers in United States dealt with racial characteristics, socioeconomic characteristics of the patients, tumor size (6), and bilaterality of parametrial or pelvic side wail invasion (5), whereas papers from Japan treated of the tumor markers. The common trend in the process of staging work-up was decreased use of lymphangiogram, barium enema and increased use of CT and MRI over the times. The recent subject from the Korean papers dealt with concurrent chemoradiotherapy (9 papers), treatment duration (4), tumor markers (B) and unconventional fractionation. Conclusion: By comparing papers among 3 nations, we collected items for Korean uterine cervix cancer PCS. By consensus meeting and close communication, survey items for cervix cancer PCS were developed to measure structure, process and outcome of the radiation treatment of the cervix cancer. Subsequent future research will focus on the use of brachytherapy and its impact on outcome including complications. These finding and future PCS studies will direct the development of educational programs aimed at correcting identified deficits in care.

A Trend for Atroventricular Valve Regurgitation after a Modified Fontan Operation (변형 폰탄 수술 시행 이후에 방실 판막 폐쇄부전의 변화 양상)

  • Lim, Hong-Gook;Lee, Chang-Ha;Seo, Hong-Joo;Kim, Woong-Han;Hwang, Seong-Wook;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.305-312
    • /
    • 2008
  • Background: Anatomic and functional abnormalities of the systemic atrioventricular (AV) valve are common in single ventricle. pathologies and continue to be associated with poor early and late outcomes in surgically palliated single. ventricle patients. We aggressively performed valvuloplasty for atrioventricular valve regurgitation (AVVR) during the course toward a Fontan operation. Material and Method: Between January 1995 and December 2004, 209 patients underwent a Fontan operation in our institution. We retrospectively evaluated the prevalence of AVVR and the influence of AV valve repair on outcome, and we analyzed the progression of AVVR after the Fontan operation for 168 patients where echocardiographic follow up results for more than 6 months after the Fontan operation were available. During the course toward a Fontan operation, 25 patients underwent 30 procedures for AVVR. These procedures. were. carried out during placement of a bidirectional cavopulmonary shunt (BCPS) for nine patients, between the time of placement of a BCPS and the Fontan operation for four patients, and during the Fontan operation for 17 patients. Five patients underwent procedures for AVVR twice. Result: The late mortality rate after the Fontan operation was 4.2% (n=7), with a median follow-up duration of 52 months (range, $6{\sim}123$ months). Seven patients (4%) had unfavorable outcomes such as significant (moderate or severe) AVVR in six patients, and significant AV valve stenosis in one patient was determined at the last follow up after the Fontan operation. Among the seven patients, four patients underwent AV valve repair after the Fontan operation, and one patient underwent subsequent AV valve replacement. Progression to AVVR of equal to or greater than grade 2 was noted in 30 patients (18%) at the last follow up after the Fontan operation, including 12 patients that underwent previous AV valve procedures. Initial grading of AVVR, a previous AV valve operation, and specific AV valve morphology such as a common AV valve or mitral atresia were significant risk factors for the progression of AVVR after the Fontan operation. Conclusion: In our surgical series, a small percentage of patients showed unfavorable outcomes. related to AVVR during the course toward a Fontan operation. However, a closer follow-up is required to evaluate the progression of the AVVR after a Fontan operation, especially for patients showing poor AV valve function at the first presentation and specific AV valve morphology.

Analysis of the Perception of Hospice and Narcotic Analgesics by Family Caregivers of Terminal Cancer Patient (말기 암 환자 보호자의 호스피스와 마약성 진통제에 대한 인식도 분석)

  • Kwak, Kyung-Sook;Chun, Sung-Ho;Ha, Jung-Ok;Lee, Kyung-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.9 no.2
    • /
    • pp.106-111
    • /
    • 2006
  • Purpose: In terminal cancer patients, pain control with narcotic analgesics and supportive care by hospice are very useful treatment modality. However, many patients and their caregivers are poorly compliant in using narcotic analgesics for fear of addiction and tolerance. And also many patients and family caregivers are reluctant to accept hospice, presuming that hospice means patient's condition is no longer reversible and progressively deteriorating. The purpose of this study was to evaluate and analyze the perception of using narcotic analgesics and hospice by family caregivers of terminal cancer patients who play a critical role in health care in Korean culture. Methods: A total of 54 terminal ranter patient's family caregivers participated in this study. Questionnaire consisted of 15 questions about narcotic analgesics and hospice. Results: The study revealed following results. 1) family caregivers who are not aware of hospice are more than half (56.7%). 2) 81.8% of family caregivers agreed that hospice care is beneficial to terminal cancer patients. 3) 85.1% of family caregivers were under financial burden. 4) 83.2% of patient complained pain in 24 hours. 3) while 88.5% of family caregivers believed that narcotic analgesics can control pair, 79.1% and 79.6% of them also believed that use of narcotic analgesics would result in addiction and tolerance, respectively. Conclusion: There still exist barriers to family caregivers in using narcotic analgesics for pain control. And also, terminal cancer patient's family caregivers have poor information about hospice. Therefore, educational intervention about narcotic analgesics by pharmacist and doctors are needed for proper pain control for terminal ranter patients. In addition, more precise information about hospice care should be provided for terminal cancer patients and their family caregivers.

  • PDF

Analysis of Output Constancy Checks Using Process Control Techniques in Linear Accelerators (선형가속기의 출력 특성에 대한 공정능력과 공정가능성을 이용한 통계적 분석)

  • Oh, Se An;Yea, Ji Woon;Kim, Sang Won;Lee, Rena;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.185-192
    • /
    • 2014
  • The purpose of this study is to evaluate the results for the quality assurance through a statistical analysis on the output characteristics of linear accelerators belonging to Yeungnam University Medical Center by using the Shewhart-type chart, Exponentially weighted moving average chart (EWMA) chart, and process capability indices $C_p$ and $C_{pk}$. To achieve this, we used the output values measured using respective treatment devices (21EX, 21EX-S, and Novalis Tx) by medical physicists every month from September, 2012 to April, 2014. The output characteristics of treatment devices followed the IAEA TRS-398 guidelines, and the measurements included photon beams of 6 MV, 10 MV, and 15 MV and electron beams of 4 MeV, 6 MeV, 9 MeV, 12 MeV, 16MeV, and 20 MeV. The statistical analysis was done for the output characteristics measured, and was corrected every month. The width of control limit of weighting factors and measurement values were calculated as ${\lambda}=0.10$ and L=2.703, respectively; and the process capability indices $C_p$ and $C_{pk}$ were greater than or equal to 1 for all energies of the linear accelerators (21EX, 21EX-S, and Novalis Tx). Measured values of output doses with drastic and minor changes were found through the Shewhart-type chart and EWMA chart, respectively. The process capability indices $C_p$ and $C_{pk}$ of the treatment devices in our institution were, respectively, 2.384 and 2.136 for 21EX, 1.917 and 1.682 for 21EX-S, and 2.895 and 2.473 for Novalis Tx, proving that Novalis Tx has the most stable and accurate output characteristics.

24 Hour Esophageal PH Monitoring in Preterm Infants (미숙아에서의 24시간 식도 PH 검사)

  • Park, Jeung-Hyun;Park, Beom-Soo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.133-141
    • /
    • 2001
  • Purpose: Gastroesophageal reflux (GER) has been found to be the causative factors of apnea, stridor, feeding intolerance, poor weight gain, and sudden infants death syndrome (SIDS) in infants. GER is a well-described in infants and children, but only scant mention of the premature infants with GER can be found in the literature. Methods: Esophageal pH was measured during 24 hour in 21 healthy preterm infants, using a silicone microelectrode with an external reference electrode connected to a portable recorder. The mean age of the patients was $29{\pm}8$ days, mean gestational age was $30^{+5}{\pm}2^{+0}$ weeks, mean birth weight was $1,468{\pm}329$ g, mean postconceptional age was $34^{+6}{\pm}1^{+4}$ weeks and mean weight was $1,750{\pm}329$ g. We evaluated the following reflux parameters; number of acid reflux, number of long acid reflux, longest acid reflux minutes, and reflux index. Results: Pathologic GER was detected in 12 (57%) subjects and most interesting parameters are reflux index and number of episodes with a pH<4 during 24 hour (high correlation with postprandial reflux index). Reflux was not correlated to gestational age, birth weight, age, postconceptional age, weight, sex and medication of the theophylline. Conclusion: Gastroesophageal reflux is common in preterm infants, but it is usually not apparent, even with severe reflux.

  • PDF

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

Suitability of Measuring a Kidney Depth with Assessment of Glomerular Filtration Rateusing 99mTc-DTPA in the Ectopic Kidney and Pediatric Patients (99mTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성)

  • Choi, Jae Min;Lee, Young Hee;Shim, Dong Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2014
  • A glomerular filtration rate (GFR) study is a test that uses radioactive materials or tracers (radiopharmaceuticals) and a computer to see how well the kidneys are working. Asan Medical Center analyzed and compared data between kidney depth, acquired from kidney donors' CT image and acquired from Gates method's GFR value that are calculated by Tonnesen equation. This study was able to confirm that kidney depth measured from CT image was higher than the Gates Method's GFR value, which was calculated by Tonnessen equation; the direct relationship among pathologic results is confirmed. Particularly, kidney donor whose kidney was at the pelvic area had direct relationship with other clinical results. During the GFR test, it is necessary to confirm the location of kidney has no change with reference of CT image. If kidney depth is manually corrected using CT image when we measures GFR of deformed or horse-shoe kidney, it would be possible to acquire the compatible value which is equivalent to clinical result. There would be a possible issue of appropriateness that whether the applied GFR using CT image's kidney depth has clinical validity. In case of a pediatric patient, the GFR derived from Tonnesen was quiet underestimated while manual method and Gordon stay in normal range. Which results may be correct among them? There have been many reports about kidney depth, to be an accurate index of GFR in children. As one of the study performers, we should contemplate what the best option for pediatric patients would be.

  • PDF

The Role of Initial Relative Renal Function in Unilateral Hydronephrosis (일측 폐색성 및 역류성 수신증에서 술전 상대적 신기능의 의미)

  • Han Sang-Won;Kang Seon-Jung;Kwon Min-Jung;Kim Dae-Joong;Choi Seung-Kang;Lee Tack
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.203-208
    • /
    • 1999
  • Purpose: The information on the change of the relative renal function after operation is essential to set the initial treatment plan in unilateral hydronephrosis. So we analyzed the preoperative and postoperative relative renal function, and observed the functional changes by operation and reliability of the various factors in those changes. Materials and Methods: A retrospective trial was done of 81 patients, 35 ureteropelvic junction(UPJ) obstruction and 46 vesicoureteral reflux(VUR), among 393 patients undergoing operations at our institution from March. 1992 to February. 1997. The patients who had infravesical abnormalities, abnormal contralateral kidney and insufficient research data were excluded. We determined the relative renal functions using DTPA and MAG3 scan in UPJ obstruction and DMSA scan in VUR. The mean observation period after operation was 2.01(0.25-4) years. Results: A. UPJ Obstruction 1. The relative renal function was improved significantly after operation(P=0.0007). 2. The kidneys which have preoperative functions between 20% and 40% improved significantly in relative renal function comparing to the kidneys of the other functions(P=0.0046). B. VUR 1. The renal functions didn't improve significantly after operation(P>0.05). 2. There was no significant factor affecting the prognosis in renal functions. Conclusions: 1. The kidneys with UPJ Obstruction show the difference in functional improvement after operation according to the degree of the preoperative renal function, but more investigations about the exact value are needed. 2. In VUR there was no difference between preoperative and postoperative functions, the theoretical basis on objectives of the operation could be the symptoms or factors except the operation.

  • PDF

Simple and Effective Surgical Repair with Vascular Graft Strip for Ischemic MR (인조혈관대를 이용한 허혈성 승모판막 폐쇄부전의 수술적 치료)

  • 민호기;이승훈;이주현;성기익;박계현;전태국;박표원;이영탁
    • Journal of Chest Surgery
    • /
    • v.36 no.9
    • /
    • pp.646-650
    • /
    • 2003
  • Many surgical techniques for ischemic mitral regurgitation (IMR) have been used with their excellent results and advantages. Here, we report our simple posterior annuloplasty techniques using vascular graft strip with their early results. Material and Method: Twenty two patients (13 male) underwent the operations for IMR (excluding the papillary muscle rupture) from December 2001 to January 2003. Preoperative risk factors were low ejection fraction (<35%, n=9), hypertension (n=13), diabetes (n=9), and renal failure (Cr>2.5, n=4). The wide dissection beneath the both vena cavae and interatrial groove after bicaval cannulation enabled the easy exposure of mitral valve even in the small left atrium. After eight or nine interrupted sutures in posterior annulus for anchoring the 6 mm width vascular graft strip, symmetric (n=8) or asymmetric (n=14) annuloplasty were done. Combined surgeries were CABG (n=21), Dor procedures (n=3), tricuspid valve annuloplasty (n=1), Maze operation (n=1), and aorto-right subclavian artery bypass (n=1). Result: Except for one surgical mortality, all the patients were doing well and the mean grade of regurgitation was decreased from 2.95 to 0.88, however the ejection fraction had not changed significantly just before discharge. Post-operative valve function evaluated before discharge revealed no residual regurgitation in 8 (including 1 patient with mild stenosis due to over reduction), minimal in 11, mild in 2, and mild to moderate regurgitation in 1. One patient who had ischemic cardiomyopathy and renal failure died of the arrhythmia during the hemodialysis. Conclusion: These observations suggest that the annuloplasty with vascular graft strip could be a safe and cost effective techniques for ischemic mitral regurgitation. However, the long term evaluation for the mitral valve function should be defined for the final conclusion.