• Title/Summary/Keyword: 교정값

Search Result 514, Processing Time 0.027 seconds

Analysis of Correlation of Visual Function Findings (시기능 검사값의 상관관계 분석)

  • Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.381-389
    • /
    • 2005
  • To Analysis of Correlation of Visual Function Findings, by assessing convergence and accommodation, 92 selected objects without any ocular diseases by apperatuses of visual chart(Shinnippon CT30) and phoropter(Shinnippon VT10) at a shan distance(40 cm) were tested upon MEM retinoscopy(Welch Allyn, USA), BELL retinoscopy(Welch Allyn, USA), binocular accommodative facility (${\pm}2.00$ D nipper, Bernell Co., USA), vergence facility(prism nipper, Bernell Co., USA). The results showed as follows. MEM retinoscopy(accommodative lag) showed the same result of a right eye and left eye. Bell retinoscopy(accommodative lag) showed higher correlations between right and left eye than MEM. The lower accommodative lag meant the higher accommodative facility. The binocular accommodative facility(polaroid) was higher than binocular accommodative facility(red-green). Correlations of accommodative facility between right and left eye were higher, and as the higher monocular accommodative facility also meant the higher binocular accommodative facility, monocular and binocular accommodative facilities were relative to vergence facility, These findings can be used as a clinical guide by curing patients' visual function.

  • PDF

Shear bond strength between gold alloy and orthodontic metal bracket using light emitting diode curing light (Light emitting diode를 이용한 광중합 시 금합금과 교정용 금속 브라켓의 전단접착강도)

  • Jung, Min-Ho;Chung, Shin-Hye;Shon, Won-Jun
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • Objective: The need to bond orthodontic brackets onto various alloys has increased because of the increasing demand for adult orthodontic treatment. This study tried to evaluate the shear bond strength between gold alloy and metal bracket using light emitting diode (LED) light curing after metal primer and silicoating surface conditioning. Methods: Half of the type III gold alloy plates were treated with sandblasting with aluminum oxide and metal primer containing 4-META. the other half were treated with silica and silane. Metal brackets were bonded with Transbond XT light curing adhesive on these plates and shear bond strength were evaluated 1 hour, 6 hours, and 24 hours later. The differences of shear bond strength between groups were evaluated with two-way ANOVA. Results: The results showed higher bond strength in the silicoating group and a tendency of bond strength increase over time. Conclusions: When using LED curing lights for metal bracket bonding to alloy surfaces, long curing time and silicoating can produce a reliable bonding strength.

A new protocol of the sliding mechanics with Micro-Implant Anchorage(M.I.A.) (Micro-Implant Anchorage(MIA)를 이용한 Sliding mechancis)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.30 no.6 s.83
    • /
    • pp.677-685
    • /
    • 2000
  • Anchorage plays an important role in orthodontic treatment. Because of limited anchorage Potential and acceptance problems of intra- or extraoral anchorage aids, endosseous implants have been suggested and used. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period for osseointegration. Titanium miniscrews and microscrews were introduced as orthodontic anchorage due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and their ability to be placed in any area of the alveolar bone. In this study, a skeletal Class II Patient was treated with sliding mechanics using M.I.A.(micro-implant anchorage). The maxillary micro-implants provide anchorage for retraction of the upper anterior teeth. The mandibular micro-implants induced uprighting and intrusion of the lower molars. The upward and forward movement of the chin followed. This resulted in an increase of the SNB angle, and a decrease of the ANB angle. The micro-implants remained firm and stable throughout treatment. This new approach to the treatment of skeletal Class II malocclusion has the following characteristics . Independent of Patient cooperation. . Shorter treatment time due to the simultaneous retraction of the six anterior teeth . Early change of facial Profile motivating greater cooperation from patients These results indicate that the M.I.A. can be used as anchorage for orthodontic treatment. The use of M.I.A. with sliding mechanics in the treatment of skeletal Class II malocclusion increases the treatment simplicity and efficiency.

  • PDF

The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current (전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.149-154
    • /
    • 1991
  • We have designed and applied the calibrationmethod of $\^$90/Sr Ophthalmic Applicaton by measuring the electron currents. We considered the number of electrons which is emitted from the source, the area of the source, and the electron stopping power in the water, and those data were used for calculation. Film was used for evaluating the accurate source area. Average electron stopping power was obtained by analyzing ${\beta}$-ray energy spectrum. We compared between the result from our method and that from the TLD measurements. The calibration result from our method shows 63.3 ${\pm}$5.1 cGy/sec, while 50.7${\pm}$7.3 cGy/sec from TLD measurement. But the supplier's specification tells 46.89.4cGy/sec.

  • PDF

Design of Simple Direct Comparison Measurement System from 10 MHz to 1 GHz for Thermistor Mounts Calibration (서미스터 마운트 교정을 위한 10 MHz에서 1 GHz 주파수 대역의 단순 직접 비교 측정시스템 설계)

  • Cha, Yun-Bae;Jang, Young-Guen;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.405-412
    • /
    • 2020
  • The thermistor mount is used for precise RF power measurement because the calibration factor is constant according to the change of power. The calibration factor of the standard mount can be measured with an uncertainty less than 0.5 % from the 10 MHz to 1 GHz by direct comparison with the transfer standard using the DC substitution method. Recently, as the supply of precision power meter based on DC substitution method allows simple and fast measurement, a simple direct comparison measurement system with the same level uncertainty was designed and the minimum required specifications of components through analysis of mismatch error was proposed. The uncertainty was evaluated for system validation, and the results show that uncertainties have been well maintained within 0.5 % in the measurement frequencies.

Effect of Fluoride Recharging on Fluoride Release and Surface Properties of Orthodontic Bracket Adhesives (불소 적용 후 교정용 브라켓 접착제 종류에 따른 불소 재흡수성과 표면 변화에 관한 연구)

  • Byeon, Seon Mi
    • Journal of dental hygiene science
    • /
    • v.18 no.4
    • /
    • pp.218-226
    • /
    • 2018
  • The aim of this study was to compare fluoride release and surface changes according to different orthodontic bracket adhesives the application of fluoride products. We used non-fluoridated composite resin Transbond fluoridated composite resins Blugloo and LightBond, resin-modified glass ionomer Rely $X^{TM}$ Luting 2, and conventional glass ionomer Fuji $I^{(R)}$. Fluoride release of five orthodontic bracket adhesives and fluoride release ability after application of three fluoride products (1.23% acidulated phosphate fluoride gel, Tooth Mousse $Plus^{(R)}$, Fluor Protector, and a toothbrush with sodium fluoride-containing toothpaste) were measured using a fluoride electrode that was connected to an ion analyzer. After 4 weeks of fluoride application, the surface roughness and surface morphology were examined using a surface roughness tester and field emission scanning electron microscopy. The amounts of fluoride release were observed not only on application of Tooth Mousse $Plus^{(R)}$ and Fluor Protector on resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$, but also during tooth brushing using fluoride-containing toothpaste. After application of Tooth Mousse $Plus^{(R)}$, except Transbond XT, the surface roughness increased, and all orthodontic adhesives showed a partial drop of micro-particle filler. On application of 1.23% acidulated phosphate fluoride gel on all orthodontic bracket adhesives, their surface roughness increased. To bond the orthodontic bracket, resin-modified glass ionomer Rely $X^{TM}$ Luting 2 and Fuji $I^{(R)}$ adhesives are highly recommended if the amount of fluoride release is considered to confer a preventative effect on dental caries, and among the fluoride products, Tooth Mousse $Plus^{(R)}$ and Fluor Protector are better than 1.23% acidulated phosphate fluoride gel, and these are expected to prevent dental caries even during tooth brushing with fluoride-containing toothpaste.

Exercise Posture Calibration System using Pressure and Acceleration Sensors (압력 및 가속도 센서를 활용한 운동 자세 교정 시스템 )

  • Won-Ki Cho;Ye-Ram Park;Sang-Hyeon Park;Young-Min Song;Boong-Joo Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.781-790
    • /
    • 2024
  • As modern people's interest in exercise and health increases, the demand for exercise-related information and devices is increasing, and exercising in the wrong posture can lead to body imbalance and injury. Therefore, in this study, the purpose of this study is to correct the posture for health promotion and injury prevention through the correct exercise posture of users. It was developed using Arduino Uno R3, a pressure sensor, and an acceleration sensor as the main memory device of the system. The pressure sensor was used to determine the squat posture, and the acceleration sensor was used to determine three types of gait: normal step, nasolabial step, and saddle step. Data is transmitted to a smartphone through a Bluetooth module and displayed on an app to guide the user in the correct exercise posture. The gait was determined based on the 20˚ angle at which the foot was opened, and the correct squat posture was compared with the ratio of the pressure sensor values of the forefoot and hindfoot based on the data of the skilled person. Therefore, based on an experiment with about 90% accuracy when determining gait and 95% accuracy based on a 7:3 ratio of pressure sensor values in squat posture, a system was established to guide users to exercise in the correct posture by checking in real time through a smartphone application and correcting exercise in the wrong posture.

KFDA TLD Dose Quality Audit and Measurement Uncertainty (식품의약품안전청의 치료방사선 선량보증과 측정불확도)

  • Jeong, Hee-Kyo;Lee, Hyun-Ku;Kim, Gwe-Ya;Yang, Hyun-Kyu;Lim, Chun-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.153-156
    • /
    • 2004
  • Korea Food and Drug Administration(KFDA) has peformed the calibration of therapy level dosimeters for Co-60 radiation since 1979. The reference standard ionization chamber has been calibrated at BIPM in France. The uncertainty on the KFDA calibration coefficients is 0.9 %(k=2) for air kerma and absorbed dose to water. Since 1999 a national quality audit program for ensuring dosimetry accuracy in Korea radiotherapy centers has been performed by the KFDA. The uncertainty associated with the determination of the absorbed dose to water from the TLD readings for high energy x-ray is 1.6 %(k=1). The correction factors for energy, non-linearity dose response, and TLD holder are used in the dose determination. Agreement between the user stated dose and KFDA measured dose within ${\pm}$ 5 % is considered acceptable. KFDA TLD postal dose quality audit program was peformed for 71 beam qualities of 53 domestic radiotherapy centers in 2003. The results for quality assurance showed that 63 out of 71 beam qualifies (89 %) satisfied the acceptance limit. The second audit was carried out for the centers outside the limit and ail of them have been corrected.

  • PDF

Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses (흡수선량 측정 시 동종 원통형 이온함에서 이온함 간 변화)

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Kim, Hyeog-Ju;Lim, Chun-Il;Shin, Dong-Oh;Choi, Jin-Ho
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.120-125
    • /
    • 2010
  • For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor ${\kappa}_{Q,Q_0}$ of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same ${\kappa}_{Q,Q_0}$ to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.

Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber (평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구)

  • Rah, Jeong-Eun;Shin, Dong-Oh;Park, So-Hyun;Jeong, Ho-Jin;Hwang, Ui-Jung;Ahn, Sung-Hwan;Lim, Young-Kyung;Kim, Dong-Wook;Yoon, Myong-Geun;Shin, Dong-Ho;Lee, Se-Byeong;Suh, Tae-Suk;Park, Sung-Yong
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, $Z_{ret}=0.6R_{50}-0.1$ in water phantom. The $D_W$ of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the $D_W$ of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.

  • PDF