• Title/Summary/Keyword: 교량 건설

Search Result 717, Processing Time 0.028 seconds

The Influence of the Aspect Ratio on the Natural Frequency of the Specially Orthotropic Laminated Plates (특별직교이방성 적층판의 고유진동수에 대한 형상비의 영향)

  • Han, Bong Koo;Kim, Duck Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.219-225
    • /
    • 2011
  • Advanced composite structures are too difficult for such design engineers for construction and some simple but accurate enough methods are necessary. The simply supported laminated plates are analyzed by the specially orthotropic laminates theory. This method, however, may be too difficult for some practising engineers. In this paper, the result of analysis for such plate by means of the beam theory with unit width is reported. The plate aspect ratio considered is from 1 : 1 to 1 : 5. Most of the bridge and building slabs on girders have large aspect ratios. For such cases further simplification is possible by neglecting the effect of the longitudinal moment terms($M_x$) on the relevant partial differential equations of equilibrium. In this paper. the influence of the aspect ratio on the natural frequency of the specially orthotropic laminated plates is studied and it is concluded that the method used is sufficiently accurate for engineering purposes. The result of this paper can be used for simply supported laminated plates analysis.

A Study on Repair Method of Concrete Structures using the Solution of Removing Chloride (염분제거용 약액을 이용한 콘크리트 구조물의 보수공법에 관한 연구)

  • Kim, Woonhak;Hwang, Sungwoon;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.562-569
    • /
    • 2017
  • Reinforced concrete is used for bridges and large structures that are constructed with social overhead capital because they are economically and semi-permanently integrated with reinforcing bar and concrete. However, when the chloride ion in the concrete destroys the passive film of the reinforcing bar by the marine exposure environment and the snow remover used in the winter season, and the reinforcing bar is corroded by various chemical and physical actions, the durability is deteriorated in a short period, and the life span is shortened. In this study, a repair method to recover the durability of the initial structure by effectively removing chloride ion from the damage caused by salting of the above mentioned reinforced concrete was conducted.

Study on Crack Monitoring System in Steel Structure (강부재의 균열 모니터링에 관한 연구)

  • Lee, Jae-Sun;Chang, Kyong-Ho;Hwang, Jee-Hoon;Park, Hyun-Chan;Jeon, Jun-Tai;Kim, You-Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.2
    • /
    • pp.159-167
    • /
    • 2011
  • Steel structure construction is currently increasing on account of the many merits of steel structures. Due to numerous environmental factors, many cracks and extensive corrosion occur in steel structures, which cause the deterioration of the performance and life cycle of such structures. Maintenance of steel structures is thus strongly demanded, for safety control. The inspection methods that are currently being used, however, are very limited and can detect only local defects in steel structures. They also take much time to use and incur high maintenance costs. Moreover, such methods cannot be applied to huge steel structures, which men find unapproachable. They also require much time due to the need for periodic checks, and may lead to cost loss. Therefore, the development of a monitoring system that can detect defects in whole structures and can reduce the repair and strengthening costs at an early stage is very much needed. In this study, the generation and propagation of cracks were monitored via the electric-potential-drop method (EPDM).

Studies on Debris Flows by Heavy Rainfall in Osaek Area in July 2006 (2006년 7월 집중호우로 인한 오색천 유역의 토석류 발생과 그 특성)

  • YANG, Heakun;PARK, Kyeong
    • Journal of The Geomorphological Association of Korea
    • /
    • v.15 no.2
    • /
    • pp.25-35
    • /
    • 2008
  • Typhoon Ewiniar and Bilis followed by heavy rainfall in July 2006 triggered massive slope failures and debris flows along the Osaek valley within Seoraksan National Park. Since national road 44 is constructed along the fault-line, the susceptibility of hazard in the area is very high. Debris flows in Osaekcheon are mobilized from landslides near the ridgelines and peaks when heavy rainfall elevates pore pressure and adds weight to the hillslopes, causing failure. Stream flows falling onto the existing colluvium or channel-margin deposits also trigger debris flows. Steep slopes constructed along the road and thin regolith in the slope is the main reason for the landslide in the upper stream. In middle reaches of stream, under-fit drainage utilities and narrow bridges cause the overflow, this then triggers debris flow. Overflowing and erosion in the channel margin deposits is main reasons for the debris flow. The intensities and frequencies of heavy rainfall are certain to increase, so early warning and management system for the landslide-related hazard is urgently needed.

Accuracy Analysis for Velocity Measurement of Microwave Water Surface Current Meter Considering Yaw Angle and Illuminated Area (편각과 측정영역을 고려한 전자파표면유속계의 유속 측정 정확도 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Kyungdong;Kim, Seojun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.100-100
    • /
    • 2016
  • 전자파표면유속계는 대표적인 비접촉식 계측기기로 최근 유량조사를 위해 활발하게 활용되고 있다. 국내에서 사용되고 있는 전자파표면유속계는 평수기 저유속에서도 측정이 가능하고 편각 측정이 가능하도록 개발되어 한 측정 지점에서 다 지점의 유속이 측정이 가능해 평수기 홍수기에 비교적 적은 인원으로 빠른 시간에 유량측정이 가능하다. 하지만 국내의 경우 전자파표면유속계가 과연 얼마만큼의 정확한 유속을 측정하는지에 대한 분석이 다소 부족한 실정으로 특히, 실제 하천에서 정확한 분석은 수행되지 않은 상태에서 유량 측정에 사용되고 있다. 전자파표면유속계를 실제 하천에서 사용할 경우 발생 할 수 있는 오차의 요인으로는 교량과 같이 높은 지점에서 측정을 수행할 경우 측정영역(Footprint or Illuminated area)에 따른 오차가 발생할 수 있는 가능성이 있고, 동일 측정 지점에 대해 수직각과 편각에 변화에 따른 유속 측정 오차가 발생할 수 있다. 이에 본 연구에서는 국내에서 개발된 Mutronics사의 전자파표면유속계(MWSCM; Microwave Water Surface Current Meter)에 레이저포인터를 부착하여 표면유속 약 0.5m/s ~ 1m/s의 자연 하천과 매우 유사한 실제 소하천 규모의 한국건설기술연구원 안동실험센터 직선하천에서 수직각(Tilt angle) 및 편각(Yaw angle)을 변화시켜가며 유속를 측정하였다. 그리고 측정된 결과를 활용하여 수직각과 편각의 변화에 따른 전자파표면유속계의 측정영역을 검토하였고, 동일한 측정 지점에 micro-ADV를 이용해 측정된 연직유속분포를 외삽하여 산정된 표면유속과 비교하여 전자파표면유속계의 측정 정확도를 분석하였다. 분석결과, 수직각(Tilt angle) 15도 이하에서는 유속 측정의 정확도가 떨어지는 것으로 나타났고, 편각(Yaw angle)이 커질수록 측정영역이 커지게 되어 변동 계수가 증가하는 것으로 나타났다. 그리고 전자파표면유속계의 측정 오차는 측정영역에 민감하게 반응하는 것으로 나타나 실제 전자파표면유속계를 이용한 유량측정 시 측정영역을 고려한 측정이 수행되어야 할 것으로 판단된다.

  • PDF

Structural Performance Analysis of New Type CFTA Girder Bridge (신형식 CFTA 거더 교량의 구조성능평가)

  • Lee, Ji-O;Jeong, Min-Chul;Park, Kyung-Hoon;Kong, Jung-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • In this research, static load test is performed to verify the arch effect and structural performance of CFTA(Concrete-Filled and Tied steel tubular Arch) girder, and FE(Finite Element) analysis is performed to investigate validity of the test result. CFTA girder is designed to maximize the benefit of each material, such as steel plate, filled concrete and PS tendon. Static load test is performed based on the frame-analysis result of 12m sample miniature model. The result of static load test is that structural performance and safety of CFTA girder are confirmed and there is different deflection mode with other structural form result from arch effect. FE analysis with ABAQUS is also performed to show the validity of the truck collision safety and static load test.

A Study on the Characteristics of Each Type of LED Digital Landscape Lighting in Expressway Tunnel (고속도로 터널 내 LED Digital 경관조명 디자인의 유형별 특징 비교 연구)

  • Hwang, Ye-Jin
    • Journal of Digital Convergence
    • /
    • v.19 no.12
    • /
    • pp.457-462
    • /
    • 2021
  • As South Korea is a mountainous topography, installation of tunnel is essential for construction of expressway in straight lines. According to "2019 Road Bridge and Tunnel Status Report", there are 2,682 tunnels in Korea with total length of 2,077km. Tunnels take up 1.9% of total road length and the number of tunnel increased by 94% with 1,300 newly constructed tunnels over the 10 years. According to domestic and foreign researches, a long tunnel over 1km in expressway has dark lightings and monotonous wall design which decrease driver's concentration and make the driver feel bored. This leads to feeling fatigue and drowsiness more easily. In response, Korea Expressway Corporation installed design lighting that increases attentiveness on 10 tunnels with total length over 3km by 2020. To reduce the risks of accident that may happen inside the tunnel, this study conducted a comparative analysis on characteristics of each type of LED landscape lighting installed inside the expressway tunnel. The study aimed on providing the basic material for effective installation of LED landscape lighting for securing driving stability, reducing fatigue, and lowering the risk of drowsiness.

Performance analysis for reduction facility of nonpoint source pollutant (비점오염원 저감장치의 성능분석)

  • Lee, Jong-Seok;Kim, Chi-Gon
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.3
    • /
    • pp.207-217
    • /
    • 2019
  • This study aims at development and application of a facility that is capable of reducing pollution in water quality by reducing nonpoint source pollutants (NPSP). NPSP originated from the initial rainfall caused not only large catchment of urban area pass a river but also small watershed pass a stream. For this purpose, the performance tests carried out with the field models from the facility based on the preceding study. And the tests induced reduction efficiency of biochemical oxygen demand (BOD), chemical oxygen demand (COD), total nitrogen (T-N) and suspended solid (SS), respectively. The average reduction efficiency obtained by time interval, and the result showed an excellent reduction performance. As a result, the facility satisfied reduction efficiency of NPSP of the proposed standard by the National Institute of Environmental Research, and thus it can be used in practical applications.

LoRa LPWAN Sensor Network for Real-Time Monitoring and It's Control Method (실시간 모니터링을 위한 LoRa LPWAN 기반의 센서네트워크 시스템과 그 제어방법)

  • Kim, Jong-Hoon;Park, Won-Joo;Park, Jin-Oh;Park, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.359-366
    • /
    • 2018
  • Social infrastructure facilities that have been under construction since the country's high-growth period are undergoing rapid aging, and safety assessments of large structures such as bridge tunnels, which can be directly linked to large-scale casualties in the event of an accident, are necessary. Wireless smart sensor networks that improve SHM(Structural Health Monitoring) based on existing wire sensors are difficult to construct economical and efficient system due to short signal reach. The LPWAN, Low Power Wide Area Network, is becoming popular with the Internet of Things and it is possible to construct economical and efficient SHM by applying it to structural health monitoring. This study examines the applicability of LoRa LPWAN to structural health monitoring and proposes a channel usage pre-planning based LoRa network operation method that can efficiently utilize bandwidth while resolving conflicts between channels caused by using license - exempt communication band.

Computational Model for Hydrodynamic Pressure on Radial Gates during Earthquakes (레디얼 게이트에 작용하는 지진 동수압 계산 모형)

  • Phan, Hoang Nam;Lee, Jeeho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.5
    • /
    • pp.323-331
    • /
    • 2019
  • In this study, a computational model approach for the modeling of hydrodynamic pressures acting on radial gates during strong earthquakes is proposed. The use of the dynamic layering method with the Arbitrary Lagrangian Eulerian (ALE) algorithm and the SIMPLE method for simulating free reservoir surface flow in addition to moving boundary interfaces between the fluid domain and a structure due to earthquake excitation are suggested. The verification and validation of the proposed approach are realized by comparisons performed using the renowned formulation derived by the experimental results for vertical and inclined dam surfaces subjected to earthquake excitation. A parameter study for the truncated lengths of the two-dimensional fluid domain demonstrates that twice the water level leads to efficient and converged computational results. Finally, numerical simulations for large radial gates with different curvatures subjected to two strong earthquakes are successfully performed using the suggested computational model.