• Title/Summary/Keyword: 광 케이블

Search Result 80, Processing Time 0.031 seconds

A Study on HVDC Underwater Cable Monitoring Technology Based on Distributed Fiber Optic Acoustic Sensors (분포형 광섬유 음향 센서 기반 HVDC 해저케이블 모니터링 기술 연구)

  • Youngkuk Choi;Hyoyoung Jung;Huioon Kim;Myoung Jin Kim;Hee-Woon Kang;Young Ho Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.199-206
    • /
    • 2023
  • This study presents a novel monitoring technique for underwater high-voltage direct current (HVDC) cables based on the Distributed Acoustic Sensor (DAS). The proposed technique utilizes vibration and acoustic signals generated on HVDC cables to monitor their condition and detect events such as earthquakes, shipments, tidal currents, and construction activities. To implement the monitoring system, a DAS based on phase-sensitive optical time-domain reflectometry (Φ-OTDR) system was designed, fabricated, and validated for performance. For the HVDC cable monitoring experiments, a testbed was constructed on land, mimicking the cable burial method and protective equipment used underwater. Defined various scenarios that could cause cable damage and conducted experiments accordingly. The developed DAS system achieved a maximum measurement distance of 50 km, a distance measurement interval of 2 m, and a measurement repetition rate of 1 kHz. Extensive experiments conducted on HVDC cables and protective facilities demonstrated the practical potential of the DAS system for monitoring underwater and underground areas.

Analysis of Hydrid Fiber Coaxial technology and Market (HFC 기술 및 시장 분석)

  • Yoo, H.K.;Kim, J.H.;Kang, B.Y.;Park, K.C.
    • Electronics and Telecommunications Trends
    • /
    • v.18 no.6 s.84
    • /
    • pp.34-40
    • /
    • 2003
  • 1998년 시작된 초고속 인터넷 서비스는 약 4년 만에 세계 1위의 보급률을 보이고 있을 정도로 우리 나라의 정보통신 인프라는 급속도로 성장하여 왔다. 최근 유무선 통합 및 통신과 방송이 융합되는 광대역 통합망(BcN) 환경에서 초고속 인터넷 서비스와 디지털방송 서비스를 제공하기 위한 초고속 인프라의 가입자망 형태는 동선 기반의 ADSL(Asymmetric Digital Subscriber Line)/VDSL(Very high-data rate Digital Subscriber Line) 및 광/동축 혼합망인 HFC, 광섬유 기반의 FTTH(Fiber To The Home) 등이 있다. 그 중에서 HFC는 그 동안 주로 케이블 TV 프로그램의 전송망으로 활용되어 오다가 최근 통신. 방송 융합 환경에서 초고속 인터넷 가입자망으로 부각되고 있다. 본 고에서는 HFC 망의 특성과 HFC 망의 핵심장비인 CMTS와 케이블모뎀의 시장 현황 및 전망에 대해서 알아보고, 광대역 통합망의 가입자망으로서의 HFC의 역할에 대해 논의하고자 한다.

A Novel optical access network architecture using passive optical network (WDM-PON 기반 유사 FTTH 광가입자망 기술)

  • Hong, Sang-Gi;Kim, Bo-Gyeom;Lee, Won-Hyeong;Park, Tae-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.53-55
    • /
    • 2005
  • 일반주택지역을 위한 초고속인터넷 제공방안은 xDSL과 HFC 기술방식이 적용되어 왔다. HFC는 전송속도의 기술적 한계를 가지며, xDSL은 기존 동선을 활용하는 솔루션으로 경제적인 장점을 가지지만 동선 선로품질에 따라 품질저하가 발생한다. 이에 UTP케이블이 기포설된 1등급 아파트에만 공급 가능하였던 100Mbit/s 패스트이더넷을 일반주택지역에 공급하기 위한 유사FTTH 시스템이 개발되어 현장에 운용 중이다. 광코어 절감 및 운용유지 측면을 고려하여 WDM-PON (Wavelength Division Multiplexing-Passive Optical Network, 파장분기 수동형광가입자망) 방식을 채택하였으며, 가입자 인근 전주까지 광케이블이 포설되어 ONU(Optical Network Unit)가 설치되며, ONU로부터 가입자 댁내 단말까지 가공형 UTP케이블을 통해 패스트이더넷을 공급하는 방식이다.

  • PDF

Design and Implementation of an Around View Monitoring System based on MOST Network (MOST 네트워크 기반 어라운드뷰 모니터링 시스템의 설계 및 구현)

  • Jang, Si-woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.511-514
    • /
    • 2014
  • 주차나 후진 시에 도움을 주기 위한 후방 카메라는 after-market을 통하여 많이 보급되어 있으나 좌우 측방과 전방의 차량 경계를 확인할 수 없어 많은 불편함이 있다. 차량의 주변을 한 눈에 감시할 수 있는 어라운드뷰 시스템은 자동차 벤더들에 의해 장착되고 있으나 이에 대한 체계적인 연구는 부족한 실정이다. 일본 닛산 자동차의 인피니티 차량에 적용된 AVM이 이에 적합한 제품이지만 아날로그 케이블을 사용하여 부가적인 케이블링 작업과 EMI에 대한 간섭에 따른 화질저하의 단점을 가진다. 본 논문에서 구현된 MOST150 네트워크 기반 어라운드뷰 시스템은 광 네트워크이므로 EMI/EMC 문제가 없으며 배선이 간단하다는 장점이 있으며, MOST150 네트워크가 구축된 환경에서는 plug-and-play 형태로 쉽게 장착할 수 있는 장점이 있다.

  • PDF

Crack Detection of Concrete Using Fiber Optic Cables (Fiber Optic Cable을 이용한 콘크리트 균열탐사)

  • Cho, Nam-So;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.157-163
    • /
    • 2007
  • Crack detection technique for concrete structures has been developed in this study. Experimental tests were carried out to detect a surface and internal crack, employing common fiber optic cables and OTDR(optical time domain reflectometry), an optical signal analyzer which is widely used to detect damages at fiber optic cables in the field of optical engineering. While initial concrete crack is ready to occur under cracking force, the occurrence and location of the crack are simultaneously detected to give the same damage to fiber optic cables which have been attached to and/or embedded into concrete in advance. It is obtained through successive tests that the principal factors for crack detection is the covering state of fiber optic cable, and total 4 tests including a preliminary test were conducted and the crack detection technique was verified. The practical usefulness would be expected at crack management and maintenance of concrete structures.

Design of Bridge Transport System with Equal Incremental Telescopic Motion (동일신축 텔레스코픽모션을 갖는 천정이동장치 설계)

  • Yoon, Kwang-Ho;Lee, Hyo-Jik;Lee, Jong-Kwang;Park, Byung-Suk;Kim, Ki-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.227-235
    • /
    • 2010
  • This paper introduces the design of a bridge transport system with a telescopic tube for positioning equipment to perform remote handling tasks in a radioactive facility. It consists of an extensible and retractable telescopic tube assembly for z-direction motion, a cabling system for management of power and signal cables, and a trolley system for transverse motion and accommodating servo drives. The working environment for the bridge transport system with the telescopic tube requires strict geometrical constraints, including a short height, short telescopic tube length when retracted, and a long stroke. These constraints were met by solving a nonlinear programming problem involving the optimal dimensions. This paper introduces a cabling system for effective management of cables with changeable lengths to accommodate telescopic motions and a selection guide for servo drives that are sufficient to drive the system.

Design and development of VSI Optical Adapter for high speed transmission of VLBI observation data (VLBI 관측데이터 초고속 전송을 위한 VSI 광변환 송수신 장치의 설계 및 개발)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Yeom, Jae-Hwan;Jung, Jin-Seung;Jung, Dong-Kyu;Oh, Chung-Sik;Ozeki, Kensuke;Onuki, Hirofumi;Harada, Keniichi
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.4
    • /
    • pp.261-269
    • /
    • 2013
  • This paper describes the design and development of VSI (VLBI standard interface) optical adapter for transmitting VLBI(Very long baseline interferometry) observation data with optical signal. VSI cable comprised of 80-line is being used for observed data transmission with maximum length of 5-meter between playbacks (Mark5B, VERA2000) and raw VLBI data buffer (RVDB), RVDB and VLBI correlation subsystem (VCS) in Daejeon correlator. It has a plan to conduct the data processing for 16-stations and introduce the 14 RVDB systems in near future. And data loss frequently occurred because of trouble of VSI cable MDR80 connector. By considering the data loss by connector error of VSI cable, RVDB system extension plan, effective space usage and long distance data transmission(e-VLBI), the VSI optical adapter was proposed and developed for effectively transmitting and receiving VLBI data through optical signal. In order to confirming the performance of developed VSI optical adapter, the experiments for data transmission was conducted between playback and RVDB system, and confirmed that data transmission was clearly done without any data loss.

초고속통신망 가입자장치 국내 개발현황

  • 심창섭
    • Information and Communications Magazine
    • /
    • v.16 no.6
    • /
    • pp.72-81
    • /
    • 1999
  • 현재 국내의 초고속통신망의 중심인 가입자망 구축은 통신사업자를 중심으로 시작단계에 있으며 갈수록 수요가 급증하고 있고 이에 따른 신규 서비스망의 구축이 요구되고있다. 또한 국내 제조업체들도 많은 역량을 투자하여 연구개발을 수행하고 있으며 새로운 서비스 충족을 위한 다양한 기능의 장비를 출시하고 있다. 초고속가입자망장비는 광 가입자망장비, xDSL 장비, 무선망 장비 및 케이블 망 장비 등이 있다. 본 논문에서는 이러한 가입자망 장비의 개발현황을 중심으로 다루고자 한다.

  • PDF

차세대 수동형 광가입자망 표준화 및 기술개발 동향

  • Yu, Hak;Kim, Geun-Yong;Kim, Seong-Chang;Lee, Dong-Su;Kim, Yeong-Seon
    • Information and Communications Magazine
    • /
    • v.31 no.8
    • /
    • pp.74-83
    • /
    • 2014
  • 수동형 광가입자망 (PON: Passive Optical Network) 기술은 가입자의 단말과 국사의 장비를 광섬유로 직접 연결하여 기존의 전화선 및 동축케이블을 이용한 xDSL 및 HFC등에 비해 전송속도가 빠르고 관리가 수월한 인터넷 서비스 제공이 가능한 기술이다. 본고에서는 ITU-T와 IEEE에서 진행중인 차세대 수동형 광가입자망 기술의 국제 표준화 동향에 대하여 알아보고, 관련 기술개발 현황 및 새롭게 부각되는 스마트 광 분배망 기술과 SDN (Software Defined Network) 기반 광가입자망 운용관리 등의 연구분야에 대하여 알아본다.

Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP (EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석)

  • Jung, Chae-Kyun;Jang, Tai-In;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.9
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.