• Title/Summary/Keyword: 광 산란

Search Result 353, Processing Time 0.031 seconds

Analysis of structural properties of epitaxial BST thin films prepared by pulsed laser deposition (펄스형 레이저 증착법으로 제조된 에피탁시 BST 박막의 구조 분석)

  • 김상섭;제정호
    • Journal of the Korean Vacuum Society
    • /
    • v.7 no.4
    • /
    • pp.355-360
    • /
    • 1998
  • Epitaxial $Ba_{0.5}Sr_{0.5}TiO_3$thin films of two different thickness (~250 $\AA$ and ~1340 $\AA$) on MgO(001) prepared by a pulsed laser deposition method were studied by synchroton x-ray scattering measurements. The film initially grew on MgO(001) with a cube-on-cube relationship, maintaining it during further growth. As the film grew, the surface of the film became rough significantly, but the interface between the film and the substrate seemed to have changed little. In the early stage, the film was highly strained in a tetragonal structure with the longer axis parallel to the surface normal direction. As the growth proceeded further, it was mostly relaxed to a cubic structure with the lattice parameter of the bulk value and the mosaic distribution improved significantly in both in-plane and out-of-plane directions.

  • PDF

Infrared Imaging and a New Interpretation on the Reverse Contrast Images in GaAs Wafer (GaAs 웨이퍼의 적외선 영상기법 및 콘트라스트 반전 영상에 대한 새로운 해석)

  • Kang, Seong-jun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2085-2092
    • /
    • 2016
  • One of the most important properties of the IC substrate is that it should be uniform over large areas. Among the various physical approaches of wafer defect characterization, special attention is to be payed to the infrared techniques of inspection. In particular, a high spatial resolution, near infrared absorption method has been adopted to directly observe defects in semi-insulating GaAs. This technique, which relies on the mapping of infrared transmission, is both rapid and non-destructive. This method demonstrates in a direct way that the infrared images of GaAs crystals arise from defect absorption process. A new interpretation is presented for the observed reversal of contrast in the infrared absorption of nonuniformly distributed deep centers, related to EL2, in semi-insulating GaAs. The low temperature photoquenching experiment has demonstrated in a direct way that the contrast inverse images of GaAs wafers arise from both absorption and scattering mechanisms rather than charge re-distribution or local variation of bandgap.

Melting Behavior of Uni-Axially Deformed Polyethylenes Containing Comonomers as Studied by in-situ Small and Wide Angle X-ray Scattering (실시간 소각 밑 광각 X-선 산란을 이용한 일축 변형된 공단량체 함유 폴리에틸렌의 용융 거동)

  • Cho, Tai-Yon;Jeon, Hye-Jin;Ryu, Seok-Gn;Song, Hyun-Hoon
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.183-188
    • /
    • 2009
  • Structural rearrangements of uni-axially deformed polyethylenes containing 1-octene comonomer and HDPE upon heating were investigated by time-resolved small and wide angle X-ray scattering techniques. During heating, structural changes including crystal transformation and lamellar rearrangement noted were very different depending on the comonomer contents. At low comonomer content below 2 wt%, inverse martensitic transformation of crystal lattice from monoclinic to orthorhombic cell and the rearrangement of broken lamellar units into more ordered and perfect lamellar stacks were noted with the temperature increase. At high contents above 9.5 wt%, however, polyethylene copolymers showed neither the crystal transformation nor lamellar rearrangement that can be attributed to low crystallinity and high content of branch units.

An experimental study on the habitat characteristics of largemouth bass (생태교란어종 큰입배스의 서식 특성에 관한 실험적 연구)

  • Son, Minwoo;Byun, Jisun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.spc2
    • /
    • pp.845-853
    • /
    • 2019
  • The aim of this study is to investigate the factors affecting the habitat characteristics of largemouth bass (Micropterus salmoides), which is one of exotic fishes in Korea. Based on field observation, the laboratory experiments were performed in order to investigate the relationship between water temperature and the habitat characteristics of largemouth bass. It was found that largemouth bass preferred a relatively high water temperature in winter and a low temperature in summer. When the small largemouth bass coexisted with large largemouth bass, the separation of habitats depending on the size of each largemouth bass are observed. In the separated habitat areas, it is also observed that the largemouth bass preferred vicinity of the obstacle such as boulder. From the experiments for preference between water temperature and obstacle, it was observed that a primary consideration in habitat selection was obstacles. It was also observed that when light device was turned on, largemouth bass formed a new habitat.

Comparison of Scattered Light of ex vivo Mouse Neutrophils by Different Wavelength Laser Irradiation (2개의 레이저 파장에 따른 마우스 호중구의 산란광 비교 연구)

  • Park, Jae-Sung;Son, Min-Ji;Hwang, Chang-Soon;Lee, Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.365-378
    • /
    • 2022
  • Complete blood cell count(CBC) is a technique that counts leukocytes for each type of blood cell being analyzed. The principle is that laser is incident to ex vivo flowing leukocytes in a microcapillary tube and scattered light occurs by laser and leukocytes. By collecting the scattered light, we can count the types of cells because different cells generate different light-scattering patterns. However, the technique has an intrinsic limitation, scattering pattern is shown in a wide range region in the resulting, which makes it difficult to accurate analyze and use fluorescent dyes. To overcome this limitation, a new design of CBC with a dual laser, which irradiates with orthogonal angles for collecting quad-scattering information was proposed. Before development, the scattering difference depending on wavelength must be investigated to only catch up to the scattered signal by angles. Some studies, which focused on simple particles, have been conducted to theoretically and experimentally investigate different scatterings by wavelength. In this study, we propose an optical system for measuring scattered light and investigate a complex particle. As a result, the green laser made strong scattering signals in both the forward and side direction: 10% and 30%, respectively.

Fabrication of Scattering Layer for Light Extraction Efficiency of OLEDs (RIE 공정을 이용한 유기발광다이오드의 광 산란층 제작)

  • Bae, Eun Jeong;Jang, Eun Bi;Choi, Geun Su;Seo, Ga Eun;Jang, Seung Mi;Park, Young Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.1
    • /
    • pp.95-102
    • /
    • 2022
  • Since the organic light-emitting diodes (OLEDs) have been widely investigated as next-generation displays, it has been successfully commercialized as a flexible and rollable display. However, there is still wide room and demand to improve the device characteristics such as power efficiency and lifetime. To solve this issue, there has been a wide research effort, and among them, the internal and the external light extraction techniques have been attracted in this research field by its fascinating characteristic of material independence. In this study, a micro-nano composite structured external light extraction layer was demonstrated. A reactive ion etching (RIE) process was performed on the surfaces of hexagonally packed hemisphere micro-lens array (MLA) and randomly distributed sphere diffusing films to form micro-nano composite structures. Random nanostructures of different sizes were fabricated by controlling the processing time of the O2 / CHF3 plasma. The fabricated device using a micro-nano composite external light extraction layer showed 1.38X improved external quantum efficiency compared to the reference device. The results prove that the external light extraction efficiency is improved by applying the micro-nano composite structure on conventional MLA fabricated through a simple process.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Growth and Opto-electric Characterization of ZnSe Thin Film by Chemical Bath Deposition (CBD(Chemical Bath Deposition)방법에 의한 ZnSe 박막성장과 광전기적 특성)

  • Hong, K.J.;You, S.H.
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.62-70
    • /
    • 2001
  • The ZnSe sample grown by chemical bath deposition (CBD) method were annealed in Ar gas at $45^{\circ}C$. Using extrapolation method of X-ray diffraction pattern, it was found to have zinc blend structure whose lattice parameter $a_o$ was $5.6687\;{\AA}$. From Hall effect, the mobility was likely to be decreased by impurity scattering at temperature range from 10 K to 150 K and by lattice scattering at temperature range from 150 K to 293 K. The band gap given by the transmission edge changed from $2.700{\underline{5}}\;eV$ at 293 K to $2.873{\underline{9}}\;eV$ at 10 K. Comparing photocurrent peak position with transmission edge, we could find that photocurrent peaks due to excition electrons from valence band, ${\Gamma}_8$ and ${\Gamma}_7$ and to conduction band ${\Gamma}_6$ were observed at photocurrent spectrum. From the photocurrent spectra by illumination of polarized light on the ZnSe thin film, we have found that values of spin orbit coupling splitting ${\Delta}so$ is $0.098{\underline{1}}\;eV$. From the PL spectra at 10K, the peaks corresponding to free bound excitons and D-A pair and a broad emission band due to SA is identified. The binding energy of the free excitons are determined to be $0.061{\underline{2}}\;eV$ and the dissipation energy of the donor -bound exciton and acceptor-bound exciton to be $0.017{\underline{2}}\;eV$, $0.031{\underline{0}}\;eV$, respectively.

  • PDF

Development and Adult Life Span of Aphidoletes aphidimyza (Rondani) (Diptera: Cecidomyiidae) Fed on the Melon Aphid, Aphis gossypii Glover or the Green Peach Aphid, Myzus persicae($S\"{u}lzer$) (Homoptera: Aphididae) (목화진딧물(Aphis gossypii)과 복숭아혹진딧물(Myzus persicae) (Homoptera: Aphididae)을 먹이로 한 진디혹파리[Aphidoletes aphidimyza (Rondani)] (Diptera: Cecidomyiidae)의 발육 및 성충수명)

  • Kim Tae-Heung;Kim Ji-Soo
    • Korean journal of applied entomology
    • /
    • v.43 no.4 s.137
    • /
    • pp.297-304
    • /
    • 2004
  • The development of Aphidoletes aphidimyza, an aphidophagous gall midge, was studied at various constant temperatures ranging from 15 to $35^{\circ}C$, with $65{\pm}5\%$ RH, and a photo-period of 16L:8D. When A. aphidimyra was fed either on Aphis gossypii or Myzus persicae, it took 43.9 and 44.5 days, respectively, to develop from egg to pupa at $15^{\circ}C$, whereas at $25^{\circ}C$, 14.3 and 15.8 days. The developmental zero was 10.7 and $10.0^{\circ}C$, respectively, while the effective accumuative temperatures were 210.8 and 245.5 day-degrees. The nonlinear shape of temperature-dependent development, shown by A. aphidimyza when fed on either species of the aphids, was well described by the modified Sharpe and DeMichele model. When distribution model of completion time of development for each growth stage was expressed as physiological age and fitted to the Weibull fuction, the completion time of development gradually shortened from egg to larva, and to pupa. In addition, the coefficient of determination $r^2$ ranged between 0.86-0.93 and 0.85-0.94, respectively providing a good approximation of cumulative developmental rates. The life span of adult was 8.7 and 9.2 days at $15^{\circ}C$, and 3.1 and 2.7 days at $30^{\circ}C$, respectively. Egg incubation period was relatively short at $35^{\circ}C$ but hatchability was less than $50\%$ and the mortality of the larva at $35^{\circ}C$ reached $100\%$. At $30^{\circ}C$, the time of development lengthened and the adult longevity was short suggesting ill effect of high temperatures. Even though the life span of adults at $15^{\circ}C$ was relatively long, none moved freely in the rearing cage and no oviposition occurred. Accordingly, in case A. aphidimyza is adopted to suppress phytophagus aphid populations, it could be applicable to cropping systems with ambient temperatures above $20^{\circ}C$ and below $30^{\circ}C$. Within this range, A. aphidimyza adults was observed to be active and oviposit fully.

Study on the LOWTRAN7 Simulation of the Atmospheric Radiative Transfer Using CAGEX Data. (CAGEX 관측자료를 이용한 LOWTRAN7의 대기 복사전달 모의에 대한 조사)

  • 장광미;권태영;박경윤
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.99-120
    • /
    • 1997
  • Solar radiation is scattered and absorbed atmospheric compositions in the atmosphere before it reaches the surface and, then after reflected at the surface, until it reaches the satellite sensor. Therefore, consideration of the radiative transfer through the atmosphere is essential for the quantitave analysis of the satellite sensed data, specially at shortwave region. This study examined a feasibility of using radiative transfer code for estimating the atmospheric effects on satellite remote sensing data. To do this, the flux simulated by LOWTRAN7 is compared with CAGEX data in shortwave region. The CAGEX (CERES/ARM/GEWEX Experiment) data provides a dataset of (1) atmospheric soundings, aerosol optical depth and albedo, (2) ARM(Aerosol Radiation Measurement) radiation flux measured by pyrgeometers, pyrheliometer and shadow pyranometer and (3) broadband shortwave flux simulated by Fu-Liou's radiative transfer code. To simulate aerosol effect using the radiative transfer model, the aerosol optical characteristics were extracted from observed aerosol column optical depth, Spinhirne's experimental vertical distribution of scattering coefficient and D'Almeida's statistical atmospheric aerosols radiative characteristics. Simulation of LOWTRAN7 are performed on 31 sample of completely clear days. LOWTRAN's result and CAGEX data are compared on upward, downward direct, downward diffuse solar flux at the surface and upward solar flux at the top of the atmosphere(TOA). The standard errors in LOWTRAN7 simulation of the above components are within 5% except for the downward diffuse solar flux at the surface(6.9%). The results show that a large part of error in LOWTRAN7 flux simulation appeared in the diffuse component due to scattering mainly by atmispheric aerosol. For improving the accuracy of radiative transfer simulation by model, there is a need to provide better information about the radiative charateristrics of atmospheric aerosols.