• Title/Summary/Keyword: 광학중심점

Search Result 77, Processing Time 0.027 seconds

The factors influencing the quantity of Phoria: I. A study of effects to the quantity of Phoria by the refractive error and the conformity to the optical center and the pupillary center (사위량에 영향을 미치는 요인: I. 굴절이상, 동공중심과 광학중심의 일치에 따른 연구)

  • Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.361-370
    • /
    • 2004
  • The purpose of this study was to evaluate the outcome and Factors that influence the quantity of Phoria in the low correction and perfect correction. Also the coincidence with the opticenter and the pupillary distance was a principal factor that influence the quantity of Phoria. Thereupon, this study is attributed to promote the perfect Phoria test. The subjects for this study were 120 persons(240 eye) in myopic refractive errors. ISP/WIN program was used for the data analysis. The collected data was analyzed by descriptive statistics and Spearman's correlation coefficient. The results of this study were as follows: 1. The prism pattern was difference between low correction and perfect correction in the Phoria test. The proportion of orthophoria was changed from 10.0% to 12.5%, exophoria was changed from 67.5% to 62.5%, and esophoria was changed from 22.0% to 32.5%, respectively. 2. The average of optical center distance and pupillary distance were 31.70mm and 31.49 mm, respectively. 3. Among the 120 myopic glasses wearers, the distance between optical centers was coincided with the pupillary distance in 37.5%, and discrepant in 62.5%. 4. For the patients who were coincided with the pupillary distance, the proportion of exophoria decreased 53.33%, esophoria increased 20.0%. 5. For the changing of the quantity of Phoria in the low correction, the degree of exophoria decreased 1.11 prism diopters in the perfect correction, esophoria increased 0.39 prism diopters.

  • PDF

A Study on the Slope Information Extraction for Wavefront Distortion Measurement of Adaptive Optics System (적응광학시스템의 파면왜곡측정을 위한 기울기정보 추출에 관한 연구)

  • 박승규;백성훈;서영석;김철중;김학수;최동혁
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.46-47
    • /
    • 2000
  • 본 논문에서는 적응광학시스템$^{(1)}$ 의 성능 향상에 필수적인 파면왜곡의 기울기 정보를 고속으로 측정하기 위한 중심점 추출 알고리즘을 제안하였다. 본 논문에서는 컴퓨터 내부의 영상처리전용보드와 CCD카메라를 이용하여 하트만 센싱 점 영상을 획득하였고, 획득한 하트만 센싱 점 영상에 대해 제안한 중심점 추출 알고리즘을 적용하여 서브픽셀 분해능으로 X축과 Y축의 기울기 정보를 고속으로 추출하였다. CCD센서에 촬상되는 하트만 센싱 점영상에서 각각의 점 영상은 중심점으로부터 대칭형으로 강도가 분포되어 있다고 가정할 수 있으나 전체 점영상의 각 점을 분석한 결과 비대칭적으로 예외적인 강도 분포를 갖는 점영상도 일부 발견되었다. 파면 왜곡이 없는 하트만 센싱 점영상으로부터 X, Y축 파면 왜곡 기울기 값을 추출한 결과 CCD 센서 픽셀의 기저 노이즈가 큰 불안정한 영역에서 기울기 값이 반복적으로 크게 추출되어 파면왜곡보정 시스템의 보정 성능을 떨어뜨리는 효과가 나타났다. (중략)

  • PDF

The Examination of Refractive Correction and Heterophoria and Monocular Pupillary Distance on Myopic Elementary School Children Wearing Glasses in Gwangju City (광주지역 근시안경 착용 초등학생의 굴절상태와 사위 및 단안PD에 대한 조사)

  • Hwang, Kwang-Ha;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.71-75
    • /
    • 2009
  • Purpose: This study was designed to investigate the condition of refractive correction and heterophoria and monocular pupillary distance on myopic elementary school children wearing glasses in Gwangju city. Methods: Subjective refraction and objective refraction were examined after investigating heterophoria and monocular pupillary distance on 145 (290eye) elementary school children wearing myopia-corrected glasses. Results: 1. Anisometropia > 2.00 D was present in 4 children (3%). 2. 9 anisometropia (47%) were present in 19 undercorrected visual acuity boy wearers. and 16 anisometropia (64%) were present in 25 undercorrected visual acuity girl wearers. 3. Among the 67 myopic glasses boy wearers, the distance between optical centers was coincided with the pupillary distance in 30% (Oculus Uterque), and discrepant in 70% (Oculus Uterque). Among the 78 myopic glasses girl wearers, the distance between optical centers was coincided with the pupillary distance in 23% (Oculus Uterque), and discrepant in 77% (Oculus Uterque). The mean optical center distance was longer than the pupillary distance on both boy and girl wearers 4. The result of measured heterophoria revealed 14% for orthophoria, 63% for exophoria, 23% for esophoria at far distance and 10% for orthophoria, 76% for exophoria, 14% for esophoria at near distance. Conclusions: Correct refractive test and monocular pupillary distance must be examined because incorrect refractive test and pupillary distance induce asthenopia and heterophoria.

  • PDF

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

A Study for the Horizontal Induced Phoria in Spectacles Wearers (안경 장용자의 수평 유발 사위에 관한 연구)

  • Sung, Duk Yong;Lee, Won Jin;Kang, Sung Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.2
    • /
    • pp.85-91
    • /
    • 1996
  • Among the 110 glasses wearers, the hyperopic glasses wearers were 18(16.36%) persons and myopic glasses wearers were 92(83.64%) persons. The distance for optical centers was coincided to the pupillary distance in 9(8.18%) persons and discrepant in 101(91.82%) persons. Ophthalmic dispensing Pupillary Distance resulted from testing by the trouble error range(Germany RAL-915), unadopt spectacles had been wearers 52(51.49%) persons. The 65(64.56%) persons and 36(35.64%) persons showed the induced esophoria and the induced exophria, respectively. The maximal induced esophoria was 3.69 prism diopters and maximal induced exophoria was 3.68 prism diopters.

  • PDF

Design of Lens and Prism used Lighthouse (대형등명기의 렌즈 및 프리즘 설계)

  • Lee, Chang-Mo;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.37-43
    • /
    • 2002
  • 원점(초점)에 놓인 광원(점광원)으로부터 방사된 ray들을 광축과 평행하게 진행하도록 그 진로의 방향을 바꾸어주는 것이 대형등명기의 광학부(중심렌즈부, 굴절링부, 절사프리즘부) 역할이다. 그래서 광학부에 대한 정밀한 설계가 이루어져야 하지만, 기존의 광학부 설계법은 어떤 설계 조건과 제작환경에 맞지 않는다. 따라서 본 논문에서는 Ray Tracing과 배광예측 프로그램인 Photopia 시뮬레이션을 통해 그 설계의 문제점을 찾고, 설계조건과 제작환경에 맞는 최적의 설계가 되도록 개선안을 제시하고 설계법을 도출하였다. 단, 초점에 위치한 광원은 모두 점광원으로 하였다.

  • PDF

A Study on the Improvement of Wavefront Sensing Accuracy for Shack-Hartmann Sensors (Shack-Hartmann 센서를 이용한 파면측정의 정확도 향상에 관한 연구)

  • Roh, Kyung-Wan;Uhm, Tae-Kyoung;Kim, Ji-Yeon;Park, Sang-Hoon;Youn, Sung-Kie;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.383-390
    • /
    • 2006
  • The SharkHartmann wavefront sensors are the most popular devices to measure wavefront in the field of adaptive optics. The Shack-Hartmann sensors measure the centroids of spot irradiance distribution formed by each corresponding micro-lens. The centroids are linearly proportional to the local mean slopes of the wavefront defined within the corresponding sub-aperture. The wavefront is then reconstructed from the evaluated local mean slopes. The uncertainty of the Shack-Hartmann sensor is caused by various factors including the detector noise, the limited size of the detector, the magnitude and profile of spot irradiance distribution, etc. This paper investigates the noise propagation in two major centroid evaluation algorithms through computer simulation; 1st order moments of the irradiance algorithms i.e. center of gravity algorithm, and correlation algorithm. First, the center of gravity algorithm is shown to have relatively large dependence on the magnitudes of noises and the shape & size of irradiance sidelobes, whose effects are also shown to be minimized by optimal thresholding. Second, the correlation algorithm is shown to be robust over those effects, while its measurement accuracy is vulnerable to the size variation of the reference spot. The investigation is finally confirmed by experimental measurements of defocus wavefront aberrations using a Shack-Hartmann sensor using those two algorithms.

기획특집 1: 군사용 전자광학 기술의 현재와 미래 -전자광학기술의 군사적 응용 및 전망

  • Hong, Seok-Min
    • The Optical Journal
    • /
    • s.130
    • /
    • pp.18-24
    • /
    • 2010
  • 군사용 전자광학장비는 1970년대 중반부터 국방과학연구소를 중심으로 관련 방산업체들이 협력하여 연구개발한 결과, 비교적 짧은 시간에 선진국 수준의 기술들이 확보되었다. 특히 생산된 전자광학장비는 군의 감시정찰 능력 증대에 활용되었고 대부분의 전술급 감시정찰 영상 장비나 사격통제용 영상센서들이 이제는 독자 개발, 생산되고 있다. 전자광학장비는 선진국에 비해 비용대비 투자 효과면에서 우위를 점하고 있기 때문에 국내 수요 뿐 아니라 세계시장을 겨냥한 수출을 적극적으로 추진해야 할 시점으로 보여지며 기술 확보를 위한 방산전문업체와 우수 중소기업의 참여 확대가 요구되고 있다.

  • PDF

Improvement of size measurement polystyrene spheres of diameters 3$\mu$m and 10$\mu$m by optical microscope with CCD camera (CCD 카메라가 장착된 광학현미경을 사용한 폴리스티렌구 (3 $\mu$m와 10 $\mu$m)의 평균지름측정)

  • 정기영;박병천;깅주식;송원영;오범환
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.362-367
    • /
    • 1998
  • Center Distance Finding (CDF) is a technique to find the sphere diameter by measuring the distance between two contacting spheres. The focal spots of the sphere clusters are formed in the back-focal plane by the transmission-mode optical microscope with the pseudothermal illumination source. Digital images taken by the CCD camera were processed by the software called Global Lab Image. The centers of the focal spots are found and the spot positions are expressed in terms of the CCD pixel elements, whose coordinate are calibrated by a heterodyne interferometer. The new CDF measurement system has been developed, which are more advantageous in time and convenience than the existing system, while the measurement uncertainly remains sufficient for its use as a magnification standard for optical microscopy. Two kinds of polystyrene spheres whose nominal diameters 3 and 10 $\mu\textrm{m}$ (NIST SRM 1962 and 1960) are measured with the uncertainly less than 1% at the confidence level of 99%, and the results are compared with the results of National Institute of Standards and Technology.

  • PDF