• Title/Summary/Keyword: 광학(optics)

Search Result 3,263, Processing Time 0.026 seconds

Study on 3 Dimensional Images Using LED by PLS with No Viewing Zone Forming Optics (LED를 PLS 배열로 사용한 시역 형성 광학계가 없는 3차원 영상의 시역에 대한 연구)

  • Choi, Kyu-Hwan;Kim, Sung-Kyu;Son, Jung-Young
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.2
    • /
    • pp.116-121
    • /
    • 2008
  • A two dimensional point light source array can replace both the viewing zone forming optics and the back light panel in the contact-type 3 dimensional imaging systems based on LC panels. This replacement can make the system structure of the 3 dimensional imaging systems no different from that of the conventional LCD and can reduce undesirable visual effects caused by the viewing zone forming optics. The problem with the point light source array is the visual quality deterioration of the system due to the non-ideal nature of the array.

The Problem and Solution Associated with Increasing Number of Ophthalmic Optics Student (안경광학과 입학정원의 증가에 따른 문제점과 해결방안)

  • Kim, Sang-Hyun;Lim, Yongmoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.9-17
    • /
    • 2010
  • Purpose: We have studied the problems associated with increased number of ophthalmic optics students and its effects on the supply and demand of optician. Methods: We collected data from Education Statistics, a white paper of Minister for Health, Welfare and Family Affairs, academyinfo web site and University (College) web site. Results: We forecasted an estimate for supply and demand of optician using the entrance number of ophthalmic optics. Conclusions: The numbers of produced optician are in excessive supply. The excessive supply of optician can contribute towards worsening working conditions and lower job satisfaction of an optician. Therefore this can result infrequent turn over of jobs within the same field and migration into the different field of areas. To solve these problems, we will need to act with the manpower policy of government by gathering the voices of the related optician agencies. Then expansion of job domain, improvement of quality level, the improvement of the working conditions for optician can be accomplished by the unification of university system and reduction of entrance numbers for department of ophthalmic optics.

Design and fabrication of a zoom optics having 20 magnification range for mid-IR(3.7-4.8$\mu$m) FLIR system (3.7-4.8$\mu$m 파장대역 FLIR 시스템을 위한 20:1 줌 렌즈 광학계 설계 및 제작)

  • 김현숙;김창우;홍석민
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.462-467
    • /
    • 1999
  • This paper describes the design and fabrication of mid-IR $(3.7-4.8{\mu}m)$ zoom optics which is used for FUR (Forward Looking Infra-Red) system with 320 $\times$ 240 focal plane arrays. The zoom optics has 20 magnification range and maximun 40$^{\circ}$$\times$30$^{\circ}$ of super wide field of view. The locus of zoom is almost linear, which gives easy access of mechanical and electro-mechanical design. The on-axis MTF of zoom optics has been measured and it shows diffraction limited optical performance. For example, it gives 0.692 at 24 cycles/mm at highest magnification, and 7.6 cycles/mradof resolving power is achieved with the operation of attached micro-scanning system.system.

  • PDF

Optical-reflectance Contrast of a CVD-grown Graphene Sheet on a Metal Substrate (금속 기판에 화학증기증착법으로 성장된 그래핀의 광학적 반사 대비율)

  • Lee, Chang-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.114-119
    • /
    • 2021
  • A large-area graphene sheet has been successfully grown on a copper-foil substrate by chemical vapor deposition (CVD) for industrial use. To screen out unsatisfactory graphene films as quickly as possible, noninvasive optical characterization in reflection geometry is necessary. Based on the optical conductivity of graphene, developed by the single-electron tight-binding method, we have investigated the optical-reflectance contrast. Depending on the four independent control parameters of layer number, chemical potential, hopping energy, and temperature, the optical-reflectance contrast can change dramatically enough to reveal the quality of the grown graphene sheet.

Design of Projection Optics System for FPD Exposure (FPD Exposure System 용 투영광학계 설계)

  • 배상신;정연욱;김용래;송청호;송준엽;김동훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1290-1294
    • /
    • 2004
  • Exposure System is used for printing a prescribed pattern on a printed board, a liquid crystal substrate or the like. In this paper we are trying to develop projection Optics Exposure System for manufacturing Color Filter of LCD Display. This paper explain the Projection Optics Design and Illumination Optics Design of Color Filter Exposure system.

  • PDF

Planar-optical interconnections by using a novel gradient-index substrate (물매-굴절률 기판을 이용한 평판광학적 광신호 연결)

  • 조무희;김영식;송석호
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.5
    • /
    • pp.431-437
    • /
    • 1997
  • A gradient-index (GRIN) substrate is proposed as a novel signal propagation medium of planar optics. The GRIN substrate provides planar-optics designers not only a 3-dimensional signal propagation space, but also an additional smart optical functioning component like as a diffraction-limited imaging lens. The novel and smart functioning of the GRIN substrate was confirmed by experiment on imaging of an input signal to multiple destinations.

  • PDF