• Title/Summary/Keyword: 관 삽입

Search Result 261, Processing Time 0.03 seconds

Fabrication of Ionization Chamber to Measure the Burnup of Spent Fuel (사용후핵연료 연소도 측정을 위한 이온 챔버 제작)

  • Park, Se-Hwan;Eom, Sung-Ho;Shin, Hee-Sung;Lim, Hye-In;Ha, Jang-Ho;Kim, Han-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.21-25
    • /
    • 2010
  • Burnup of spent fuel should be determined accurately for the safety control of spent fuel. Especially, it is necessary to measure the burnup profile along the nuclear fuel axis. In the present work, an ionization chamber was designed and fabricated to measure the gamma ray profile inside the guide tube of spent fuel. The ionization chamber was composed of three parts; induction part, gas-inlet part, and sensor part. The sensor part had two electrodes; cathode and anode. A guide electrode was considered in the ionization chamber design to make the ionization chamber to be inserted easily into the guide tube. Pure gas (argon and xenon) was inserted into the ionization chamber, and the leakage current and saturation curve were measured to determine the operation characteristics of the ionization chamber. The gamma ray radiation was also measured in relatively high dose environment. The gamma ray profile of the spent fuel will be measured with the ionization chamber.

A Comparative Study of Stenting versus Surgical Bypass in Gastric Outlet Obstruction Caused by Gastric Cancer (위암 날문부 폐쇄 환자에게 시행한 치료의 비교고찰: 위-공장 우회술과 금속성 자가팽창성 스텐트 삽입술)

  • Jo, Seung-Jin;Yoon, Ki-Young;Choi, Kyung-Hyun;Park, Moo-In;Park, Seun-Ja;Ko, Ji-Ho;Lee, Sang-Ho
    • Journal of Gastric Cancer
    • /
    • v.7 no.2
    • /
    • pp.82-87
    • /
    • 2007
  • Purpose: In gastric cancer patients with gastric outlet obstruction, there are several complications such as malnutrition and vomiting. Palliative enteral stenting is a less invasive procedure as compared with a gastrojejunostomy. The aim of this study was to determine whether there was a significant difference between patients that undergone palliative enteral slanting and patients that had received a bypass gastrojejunostomy. Materials and Methods: One hundred patients underwent palliative entering stenting and 3f patients were subjected to a surgical bypass gastrojejunostomy. We reviewed the medical records of the patients with gastric outlet obstruction secondary to far advanced gastric cancer that were diagnosed using a gastrofibroscope, UGI and abdominal CT, and were admitted to our institution between January 2000 and August 2006. The outcome of stent placement for gastric outlet obstruction was compared with palliative gastrojejunostomy during the same period. We excluded patients with recurrent gastric cancer and double cancer from this study. Results: There were significant differences between the group of patients that underwent slanting and the group of patients that received a gastrojejunostomy regarding the age of patients ($67{\pm}12$ vs. $57{\pm}9$, P<0.001) but not between the sex of the patients (M : F, 2 : 1 vs. 2 :1, P=0.637). The most common complication of stenting was tumor ingrowth (16/100, 16%) and the second most common complication was stent migration (14/100). Failure of the procedure occurred in only three patients. Twenty-three patients underwent re-slanting and one patient required open conversion with a gastrojejunostomy. The median time to the first meal was $4{\pm}2$ days in the stent group of patients and $6{\pm}2$ days in the gastrojejunostomy group of patients (P=0.001). The median postoperative hospital stays were 9 days in the stent group of patients and 15 days in the gastrojejunostomy group of patients (P=0.003). The mean survival periods were 11 months in the stent group of patients and 10 months in the gastrojejunostomy group of patients (P=0.937). Conclusion: There were no significant differences In the mean survival rates. An earlier first meal and a shorter hospitalization stay were found in the slanting group of patients compared to the bypass gastrojejunostomy group of patients. However, re-slanting was a concern due to tumor ingrowth and stent migration.

  • PDF

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Spray Visualization Using Laser Diagnostics (레이저를 이용한 분무 가시화)

  • 윤영빈
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.87-112
    • /
    • 2005
  • 분무를 정량적으로 측정하는 것은 노즐의 설계와 개발을 위해서 뿐만 아니라 연소 시스템 전반의 효율 및 불안정성의 제거, 공해 저감 등의 요구 조건을 만족하기 위해서 중요하다. 이를 위해 이전에는 분무장 내에 수집관을 삽입하는 기계적 패터네이터(Mechanical Patternator)와 같은 삽입식 측정 방식을 이용하여 왔으나, 최근에는 고속카메라, Malvern particle analyzer, PDPA, 광학 패터네이터(Optical Patternator)와 같은 분무장을 교란시키지 않으면서도 빠른 측정이 가능한 가시화 기술들이 적용되고 있다. 특히 광학 패터네이터는 레이저 평면광을 이용하여 분무를 측정하는 비삽입식 기술로 단시간 내에 분무장 내 액체 연료의 질량 및 액적 크기의 단면 분포를 동시에 얻어낼 수 있는 장점을 갖고 있다. 그러나 분무 액적들의 수밀도가 증가하는 경우에는 이들 액적에 의한 입사광 및 신호 감쇠, 다중산란 등에 의한 오차가 심하게 발생하여, 기존의 PDPA, PLIF 등의 광학 기법으로는 충분히 신뢰할 만한 결과를 얻기가 어렵게 된다. 이러한 분무를 정량적으로 측정하기 위해서는 입사광의 감쇠뿐만 아니라 분무장 내 액적들에 의한 신호의 감쇠 과정에 대한 고려가 필요하다. 주면 액적들의 영향을 최소한으로 줄이기 위해서는 레이저 평면광을 사용하는 광학 패터네이터와 달리 레이저 광선을 분무장에 조사하여 고압에서 나타날 수 있는 다중 산란에 의한 오차를 최소화할 수 있다. 이러한 이미지 처리 기법을 이용하는 광학 선형 패터네이터(Optical Line Patternator)를 이용하여 기존 레이저 계측기법으로 측정이 곤란하였던 고압 환경 하에서의 스월 동축형 인젝터의 분무 특성을 해석할 수가 있다. 2015(년도) 6,388, 2025(년도) 13,367, 2035(년도) 18,756, 2045(년도) 22,595, 시장점유율 증가로 인한 수출액 증가분 누적(억원) : 2015(년도) 3,411, 2025(년도) 8,847, 2035(년도) 14,433, 2045(년도) 18,005 또한 시나리오 비교평가를 실시하여 본 결과, 본 연구에서 정의한 순편익 누적(Cumulative Net Profit) 변수를 적용하면 현재 연구비 추세 대비 $30\%$ 까지 연구비를 증가 시키는 것이 효율적임을 알 수 있었다.성, 생산 용이성, 제품 디자인의 우수한 정도가 a=0.01 수준 하에서 유의적으로 추정되었다. 이들 변수들 중에서 품질경쟁력에 가장 큰 영향을 미치는 측정변수는 제품의 기본 성능, 수명(내구성), 신뢰성, 제품 디자인의 순서로 추정되었다. 이것은 한국 제조업이 아직 산업 디자인이 품질경쟁력에 크게 영향을 미치는 성숙단계에 이르지 못하였음을 의미한다. (2) 제품 디자인에게 영향을 끼치는 유의적인 변수는 연구개발력, 연구개발투자 수준, 혁신활동 수준(5S, TPM, 6Sigma 운동, QC 등)이며, 제품 디자인은 우선 품질경쟁력을 높여 간접적으로 고객만족과 고객 충성을 유발하는 것으로 추정되었다. 상기의 분석결과로부터, 본 연구는 다음과 같은 정책적 함의를 도출하였다. 첫째, 신상품 개발과 혁신을 위한 포괄적인 연구개발 프로젝트를 품질 경쟁력의 주요 결정요인(제품의 기본성능, 신뢰성, 수명(내구성) 및 제품 디자인)과 연계하여 추진해야 할 것이다. 둘째, 기업은 디자인 경영 마인드 제고와 디자인 전문인력 양성을, 대학은 디자인 현장 업무를 통하여 창의력 증진과 기획 및 마케팅 능력 교육을, 정부는 디자

  • PDF

Development of Modeling System for Assessing Essential Amino Acid Requirements Using Surgically Modified Rainbow Trout (외과적 수술에 의한 송어의 혈장 아미노산 농도 측정을 이용한 아미노산 요구량 설정 모델 개발에 관한 기초연구)

  • 배승철;옥임호;박건준;김강웅;최세민
    • Journal of Aquaculture
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • A new technique combining forced-feeding and dorsal aorta cannulation was developed to monitor concentration of nutritions in the blood circulation and their metabolites in rainbow trout. To study the effect of dorsal aorta cannulation on stress, 30 rainbow trout (523$\pm$5.4 g; Mean$\pm$SD) were divided into 6 groups of 5 individuals each. A group was anesthetized and blood samples were taken at 0, 3, 6, 12, 24 or 48 h after dorsal aorta cannulation. Hematocrit peaked at 6 h and returned to 0 values by 12 h after dorsal aorta cannulation. Plasma cortisol and glucose concentrations also peaked at 6 h and returned to 0 values by 48 h after dorsal aorta cannulation. Based on the plasma cortisol and glucose concentrations, the rainbow trout recovered from the operation of dorsal aorta cannulation within 48 h. To compare the patterns of plasma free amino acid concentrations after force-feeding in the fish with dorsal aorta cannulation, 5 dorsal aorta cannulated individuals (511$\pm$6.2 g) were kept in a cage. After 48 h starvation, they were anesthetized and blood samples were taken at 0, 4, 8, 12, 24, 36 or 48 h after forced-feeding. The concentration of all plasma free amino acids, except isoleucine, leucine, phenylalanine, and tryptophan, also peaked at 4 h and returned to 0 values by 24 h after feeding. The combined technique allows forced-feeding and repeated sampling of blood in rainbow trout with minimum stress.

Study on the Modeling Technique for Prediction about Pressure Drop of an Intravenous Lung Assist Device (혈관 내 폐 보조장치의 압력손실 예측을 위한 모델링기법에 관한 연구)

  • 김기범;권대규;정경락
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.293-299
    • /
    • 2003
  • In this paper, the correlation of Pressure drop about the Newtonian and non-Newtonian fluid was investigated experimentally for vibrating intravascular lung assist device (VIVLAD) and we determined correlation equation to make a prediction about Pressure drop for designing VIVLAD. Design conditions to predict the pressure drop of the modules were studied through an experimental modeling before inserting the artificial lung assist device into as venous. Experiments were performed by distilled water, glycerol/water mixed solution(40% glycerol) of Newtonian fluids. and the bovine blood of non-Newtonian fluids. These fluids were flowed outside and parallel of hollow fiber membranes. Also we measured pressure drop according to the number of the fiber membranes which ware inserted into the inside diameter of shell of 3 cm, and developed the prediction equations by curve fitting method based on correlation between the experimental pressure drop and the frontal area or the packing density of device. The result showed that the Pressure drop and the friction factor of the water/glycerol mixed solution were similar to that of bovine blood. It was showed that the water/glycerol mixed solution (40% glycerol) could be used for measuring the pressure drop and the friction factor instead of the bovine blood. Also, we could estimate the prediction equation of pressure drop and friction factor as the function of Packing density at the number of hollow fibers. We obtained the reliance of the prediction equations because the pressure drop and the friction factor measured from the experiments were similar to that from the prediction equation. These results may be used to further usefulness for the design of VIVLAD.

Relational Database SQL Test Auto-scoring System

  • Hur, Tai-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.127-133
    • /
    • 2019
  • SQL is the most common language in data processing. Therefore, most of the colleges offer SQL in their curriculum. In this research, an auto scoring SQL test is proposed for the efficient results of SQL education. The system was treated with algorithms instead of using expensive DBMS(Data Base Management System) for automatic scoring, and satisfactory results were produced. For this system, the test question bank was established out of 'personnel management' and 'academic management'. It provides users with different sets of test each time. Scoring was done by dividing tables into two sections. The one that does not change the table(select) and the other that actually changes the table(update, insert, delete). In the case of a search, the answer and response were executed at first and then the results were compared and processed, the user's answers are evaluated by comparing the table with the correct answer. Modification, insertion, and deletion of table actually changes the data table, so data was restored by using ROLLBACK command. This system was implemented and tested 772 times on the 88 students in Computer Information Division of our college. The results of the implementation show that the average scoring time for a test consisting of 10 questions is 0.052 seconds, and the performance of this system is distinguished considering that multiple responses cannot be processed at the same time by a human grader, we want to develop a problem system that takes into account the difficulty of the problem into account near future.

Guidelines for Determining Length of Tunneled Dialysis Catheter (터널식 투석관의 길이 결정 가이드라인)

  • Park, Ho-Sung;Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • A guideline for determining the optimal catheter length according to the patient's physique during tunnel-type dialysis catheter insertion used in renal failure patients is presented, and the maintenance of the function of the dialysis catheter is evaluated. From October 1, 2015 to February 31, 2016, a total of 110 (male : female = 73 : 37) patients who underwent tunnel-type dialysis catheterization performed at our hospital were treated without using guidelines. The group was divided into A group, and the group treated using the guideline into B group. Results were analyzed statistically using SPSS 20.0. As a result of the dialysis catheter insertion procedure according to the use of guidelines, the function maintenance rate of group A was 81.8%, and the function maintenance rate of group B was 96.3%. In the case of tunnel dialysis catheter procedure, the function maintenance effect was statistically significant in the group treated using the guideline compared to the group not using it (p<0.05). It can be said that it is more effective when information on the patient's underlying disease is reflected in addition to the use of guidelines.

Patent Ductus Arteriosus Occlusion with an $Amplatz^{(R)}$ Canine Duct Occluder in a Dog (개에서 $Amplatz^{(R)}$ Canine Duct Occluder를 이용한 동맥관개존증의 폐쇄 증례)

  • Kang, Min-Hee;Kim, Seung-Gon;Hahn, Tae-Yeon;Park, Hyun-Ah;Min, Sa-Hee;Park, Ji-Hwan;Kim, Tae-Woo;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.498-501
    • /
    • 2012
  • A 10-month-old intact male Maltese dog (body weight, 1.6 kg) presented with intermittent cough and abnormal heart sounds. The dog was diagnosed with a left-to-right patent ductus arteriosus (PDA) on the basis of the results of transthoracic echocardiography, color flow Doppler examination, and angiography. Transcatheter occlusion of the PDA was performed using the $Amplatz^{(R)}$ Canine Duct Occluder (ACDO) via the femoral artery. The device was placed under fluoroscopic guidance and successfully occluded the PDA. The continuous heart murmur disappeared immediately after the correction and no residual flow was detected. The dog was discharged the following day and regularly examined for complications and safety. This is the first report demonstrating the clinical application of ACDO for the transcatheter closure of PDA via the femoral artery in a small-breed dog in Korea.

Transcatheter Closure of Patent Ductus Arteriosus with a Amplatzer$^{(R)}$ Vascular Plug in Two Dogs (개에서 Amplatzer$^{(R)}$ vascular plug를 이용한 동맥관개존증의 폐쇄 2 증례)

  • Kang, Min-Hee;Kim, Jung-hyun;Moon, So-Jeung;Kim, Seung-gon;Yeo, Jung-Jin;Lee, Chang-Min;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.591-594
    • /
    • 2011
  • A 9-month-old, intact female Maltese dog and one-year-old, intact female beagle dog were presented with continuous heart murmur. These 2 dogs were diagnosed as patent ductus arteriosus (PDA) based on the two-dimensional echocardiography and angiography. Due to the large shunt size, commercially available ductal occlude device was used for transcatheter occlusion of PDA. After Amplatzer$^{(R)}$ vascular plug placement, cardiac murmur was abruptly disappeared in Maltese dog and mildly decreased in beagle dog. Complications and safety after the procedure were evaluated regularly in these 2 dogs. This is first clinical application of Amplatzer$^{(R)}$ vascular plug for transcatheter closure of PDA in two dogs in Korea.