• Title/Summary/Keyword: 관망해석

Search Result 236, Processing Time 0.028 seconds

Development of Upland Irrigation Network Analysis System Using Object -Oriented Programming (OOP) (객체지향기법을 이용한 밭관개조직 관망해석 시스템 개발)

  • 이성학;정하우
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.69-74
    • /
    • 1999
  • Upland Irrigation Network Analysis System(UINAS) used Object-Oriented Programming (OOP). The results of using OOP is definition of objects and class hierarchy for UINAS, Objects of UINAS are consist of the Pipe , Sprinkler, Valve , Pump, Tee , Bend and Contractions. The classj hierarchy have cooperative design for FEM in analysing the irrigation network. Therefore UINAS have a flexiblility in additioning the network components.

  • PDF

Probability of Pipe Breakage for Pipe Network with Surge Tank regarding Unsteady Effect (부정류 효과를 고려한 조압수조가 있는 상수관망의 파괴확률)

  • Kwon, Hyuk-Jae;Lee, Cheol-Eung
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.10
    • /
    • pp.785-793
    • /
    • 2009
  • Numerical model which can simulate the surge tank for unsteady flow was developed in the present study. Furthermore, reliability model which can calculate the probability of pipe breakage regarding unsteady effect was developed. For the risk estimation of pipe breakage and functional estimation of surge tank, probability of pipe breakage for pipe network with surge tank was calculated regarding unsteady effect. From the results, it was found that unsteady flow significantly increase the probability of pipe breakage and surge tank considerably decrease probability of pipe breakage as damping out the pressure oscillations.

Analytical Evaluation of Interference and Ratio of River Water at Riverbank Filtration Pumping Wells (강변여과 취수정의 간섭효과와 하천수 비율에 대한 해석적 평가)

  • Park, Namsik
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.8
    • /
    • pp.685-691
    • /
    • 2014
  • River bank filtration techniques seek to improve river water quality via natural processes occurring when river water is induced to a river bank. When water is pumped from multiple wells, phenomenon known as well interference affect pumping rates. Pumping wells of a bank filtration facility are connected by pipelines. In theses cases well interference is caused not only by groundwater drawdown but also by pipe headloss which depend on flow rates. In this work a comprehensive analytical method which handles groundwater flow and pipe flow is used to evaluate interferences and ratios of river water in pumping wells. A realistic case was used as an example.

Application Methods of Smart Water Grid to Small Municipalities in Nepal (네팔 소도시 내 스마트워터그리드의 적용 방안)

  • Jang, Dong Woo;Choi, Gye Woon;Park, Hyo Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.2-2
    • /
    • 2019
  • 네팔의 경우 상하수도를 비롯한 기본적인 위생시설이 크게 미비하며 수도인 카트만두조차 수십 년 된 노후관로가 상수관으로 이용되고 있다. 또한, 하수처리 시설이 사실상 전무하며, 지하수를 주요 수원으로 활용하는 대다수 지역은 식수의 오염에 따른 수인성 전염병에 취약한 실정이다. 따라서 네팔에서는 깨끗한 물과 안정적인 수도공급, 하수처리 시설의 확보가 무엇보다 중요한 과제이며, 이에 스마트워터그리드 기술의 도입을 통한 수질개선, 안정적인 수도공급방안이 요구되고 있다. 본 연구에서는 국내에서 개발된 스마트워터그리드 기술을 네팔 소도시에 적용하기 위한 방법론을 제안하였다. 네팔 소도시의 수자원 및 상수도 시설을 답사하여 문제점을 파악하고, 시설 및 운영현황을 분석하였다. 현장조사 자료를 기반으로 스마트워터그리드 기술의 적용 방향과 단기 및 중장기 계획을 제시하였다. 또한, 네팔 소도시 중 하나인 Beni시를 시범지역으로 하여 과거 30년 동안 월 강수량 기반의 가뭄지수를 분석하고, EPANET을 통하여 상수관망해석을 실시였다. 연구 결과, 가뭄의 발생횟수가 점차 빈번해지는 것으로 나타났으며, 상수관망 해석 시 대부분의 수요절점 내 수압이 설계기준보다 낮은 것으로 모의되었고, 향후 관 노후화를 고려한 절점 수압의 확보와 수질개선 방안이 제시될 필요가 있는 것으로 나타났다.

  • PDF

Fuzzy Techniques to Establish Improvement Priorities of Water Pipes (상수관로 개량 우선순위 수립을 위한 퍼지 기법)

  • Park, Su-Wan;Kim, Tae-Young;Lim, Ki-Young;Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.11
    • /
    • pp.903-913
    • /
    • 2011
  • In this paper important factors in determining improvement priorities for water pipes were categorized into the effects of a pipe failure to entire pipe network and the characteristics of individual pipe. Subsequently, mathematical models that can quantify these factors were developed using the Fuzzy techniques. The effects of a pipe failure to entire pipe network and the characteristics of individual pipe that were estimated byFuzzy techniques were coined as Fuzzy Importance Index and Fuzzy Characteristic Index, respectively. The Fuzzy Characteristic Index was further categorized into Fuzzy Deterioration Index and Fuzzy Difficulty Index. Considerations were given to applying weights to specific factors in the developed model depending on the circumstances of model applications. To provide an example of the methodology an example pipe network, Net3, of the EPANET program was used. The Fuzzy Importance Index (FII) and Fuzzy Deterioration Index (FDI) were calculated for the Net3 network by considering the hydraulic effects of a pipe failure on the entire pipe network and the pipe deterioration as one of the individual pipe characteristics. Subsequently, the improvement priorities of the pipes in the Net3 pipe network were established based on the FII and FDI.

Optimal placement of isolation valves in water distribution networks based on segment analysis (단수구역 해석을 이용한 상수관망시스템 내 최적 밸브위치 결정)

  • Lim, Gabyul;Kang, Doosun
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.291-300
    • /
    • 2019
  • If pipes are damaged in a water distribution network (WDN), adjacent valves are closed to isolate the pipes for repair. Due to the closed valves, parts of WDN are isolated from water supply sources. The isolated area is divided into Intended Isolation Area (IIA) and Unintended Isolation Area (UIA). The IIA occurs by intention to isolate the damaged pipe, while UIA is unintentionally disconnected from the sources due to IIA. Thus, the extension of isolated area and suspended flows are mainly affected by number and location of installed valves in WDN. In this study, optimization models were developed to determine optimal valve locations in WDN. In a single-objective model, total water supply suspension is minimized, while a multi-objective model intends to simultaneously minimize the suspended flow and valve installation cost. Optimal valve placement results obtained from both models were compared and analyzed using a sample application network.

Detecting Multiple Leaks in Water Pipe Networks (상수관망 내 다중누수 탐지를 위한 모형 개발)

  • Choi, Jeongwook;Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.92-92
    • /
    • 2020
  • 최근 지진 발생 빈도와 규모가 증가함에 따라 지진재해에 취약한 지하구조물의 내진성능 향상 및 신속한 복구에 관한 연구가 활발히 진행되고 있다. 대표적인 지하구조물 중 하나인 상수관망은 음용수를 안전하고 원활하게 공급하는 사회기반시설물로써 대부분의 시설물이 지하에 매설되어 있어 지진재해에 매우 취약하다. 지진으로 인해 상수관망 내 누수 및 파손 등의 피해가 발생할 경우, 물 공급이 중단되어 경제적 손실과 사회 전반적인 불편이 우려되므로 피해 관로의 신속한 파악과 복구가 이루어져야 한다. 상수관로에 발생하는 피해는 크게 누수와 파손으로 구분할 수 있다. 관로가 파손된 경우 용수가 표층으로 새어나오기 때문에 탐지가 용이하지만, 누수의 경우 표층으로 드러나는 피해가 없어 탐지 및 수리가 어려운 단점이 있다. 이러한 누수가 장기간 방치될 경우, 해당 시스템의 유수율 감소로 인한 경제적인 손실과 더불어 공급수압의 저하, 그리고 오염물 침투의 위험이 존재한다. 이러한 피해를 막기 위해서는 신속히 누수 지점을 파악한 후, 피해 관로의 교체 혹은 보수가 이루어져야 한다. 현장에서 누수를 직접 탐지하는 방법은 정확도가 높은 반면, 많은 인력과 장비 그리고 비용이 소모되는 단점이 존재한다. 따라서 현장 누수탐지에 앞서 컴퓨터를 이용한 간접 누수탐지 기법이 지속적으로 개발될 필요가 있다. 본 연구에서는 현장 누수탐지의 탐지효율을 향상시키기 위해 수압, 유량 등의 관측 데이터와 수리해석 모의 및 최적화 기법을 활용한 컴퓨터 기반의 다중누수 탐지모형을 개발하였다. 개발 모형은 국내에서 운영 중인 소블럭 상수관망시스템에 적용하여 검증하고 탐지효율을 분석하였다. 컴퓨터 모의를 이용한 다중누수 탐지모형은 지진이나 홍수와 같은 대규모 재난 발생 후, 상수관망시스템의 신속한 복구 및 운영 정상화를 위한 도구로 활용될 수 있을 것으로 기대한다.

  • PDF

Determination Algorithm of Hydraulic Parameters in Water Distribution System (상수관망의 수리학적 지배인자 결정기법)

  • Park, Jae-Hong;Kim, Sang-Hyun;Han, Kun-Yeun
    • Water for future
    • /
    • v.29 no.6
    • /
    • pp.217-224
    • /
    • 1996
  • In this paper, the evaluation of diameter, global velocity, global roughness coefficients of the water distribution pipes are examined by using pressure and flowrate measurements in selected points of the network. The selected pipe network parameters are determined through reformulation of the continuity and energy equation. Additional energy equation is considered to analyze the coefficient matrix. The resulting nonlinear equations are solved by using Newton Raphson method. Three computer models with complex pipe system are used to demonstrate these procedures. The computed results of hydraulic parameters show good agreements with KYPIPE2 flow analysis model.

  • PDF

Development of a Combined Model for Flood Inundation Simulation (홍수범람모의를 위한 내외수 연계모형 개발)

  • Yu, Jae-Hong;Kim, Hyung-Jun;Cho, Yong-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.4 s.19
    • /
    • pp.1-8
    • /
    • 2005
  • In this study, a numerical model combined by a river model and an inland model developed to simulated a flood event. The river model describing an inundation in a river solves the two-dimensional Saint Venant equations with a finite difference method. The inland model based on the ILLUDAS describes the conveyance capacity of a storm sewer system. The combined model is applied to a real situation. The model simulates reasonably the real flood event occurred in a river and inland simultaneously.

Approaches for Earthquake-driven Multiple Leakage Detection in Water Distribution Networks (지진발생 후 상수관망 다중지점 누수관로 탐지기법의 개발)

  • Choi, Jeongwook;Jeong, Gimoon;Lim, Gabyul;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.401-401
    • /
    • 2019
  • 상수관망시스템은 정수처리 된 용수를 수요처에 공급하는 사회기반시설물이며, 주로 지하에 매설되는 시설물의 특성상 관로에 누수가 발생하였을 경우, 정확한 발생지점을 파악하기가 어렵다. 특히, 지진에 의해 시스템 내 다중지점에 누수가 발생할 경우, 장기간 경제적 손실과 사용자의 불편이 예상되므로 신속히 누수지점을 파악한 후, 피해 관로의 적절한 교체 혹은 보수가 이루어져야 한다. 본 연구에서는 지진으로 인해 상수관망에 발생한 다중 누수관로의 정확한 탐지를 위해 다양한 누수탐지 기법을 제안하고 모의결과를 비교, 분석하였다. 가상의 다중 누수 시나리오를 모의한 후, 시스템 내 설치된 수압계와 유량계의 누수발생 전, 후 모니터링 값을 이용하여 1) 최적화 알고리즘을 이용한 Calibration 기법, 2) 수리해석을 통한 누수지점 역추적 기법, 3) 인공신경망을 이용한 Pattern 학습법 등을 적용하였다. 동일한 다중 누수 시나리오를 각 누수탐지 기법에 적용함으로써 누수지점 산정 결과에 대한 정확도를 비교, 분석하였다. 본 연구는 최근 국내에서 발생빈도가 높아지고 있는 지진재해 발생에 대비하여 상수관망시스템의 지진피해 복구 연구를 위해 활용될 수 있을 것으로 기대한다.

  • PDF