This study aims to evaluate the feasibility of the disinfection of clinical ultrasound probes using the vapor fumigation method, which can quickly achieve high-level disinfection. Upon the inspection of the microbial contamination level of clinically used ultrasound probes, nine different types of bacteria were detected. The disinfection efficacy of 7.5% and 35% hydrogen peroxide (H2O2) was comparatively tested for the detected microbes. The 35% H2O2 demonstrated superior efficacy per disinfection duration. No significant change was observed in the rubber component of the ultrasound probes as a result of the 35% H2O2 disinfection treatment. The probes were contaminated with the microbes detected in the microbial contamination level inspection and subsequently disinfected using the novel medical disinfector that utilizes the vapor fumigation method. As a result, the disinfection using the novel device achieved 100% eradication of the microbes from the probes.This study demonstrates that the novel vapor fumigation method-based disinfector provides a faster and more powerful means of disinfection than the conventional disinfection methods. Therefore, the novel disinfector has the potential to be used as a convenient ultrasound probe disinfector in clinical settings.
Kim, Yun-Ki;Yoo, Hyun-Sang;Kim, Min-Cheol;Hwang, Hyun-Chul;Ryu, Sam-Gon;Lee, Hae-Wan
Korean Chemical Engineering Research
/
v.52
no.3
/
pp.360-365
/
2014
Vapor-phase hydrogen peroxide(VPHP) has been used as a sterilant in the field of medical and pharmaceutical application due to low corrosive than chlorine contained sterilant. In addition, it is well known that VPHP is effective for decontamination of chemical warfare agents by adding ammonia gas. In this study, the decontamination efficiency was confirmed about CEPS, DFP and dimethoate as simulants of HD, GD and VX using VPHP respectively. For this purpose, VPHP generated from self configured device was injected into decontamination chamber and maintained for reaction time. After the decontamination, the residues are analyzed by GC/MS and decontamination efficiency was calculated. Through by-product for each simulants, the similarities in reaction mechanism of chemical warfare agents were confirmed. CEPS was completely decontaminated at 30% relative humidity within 60 min. By adding ammonia gas, DFP and dimethoate were completely decontaminated within 30 and 150 min respectively.
Journal of the Korean Society of Propulsion Engineers
/
v.13
no.4
/
pp.16-21
/
2009
This paper introduces the methods of hydrogen peroxide storage test and storability of concentrated hydrogen peroxide is estimated. Using the method of simple concentration measuring, storability was evaluated. Experiment variables were the amount of stabilizer in hydrogen peroxide, storage temperature, and caps of vessels. The experiments were performed during 8 months to 24 months. High purity hydrogen peroxide had much better storability than hydrogen peroxide with much stabilizer. In addition, the case using paraffin film which did not react with hydrogen peroxide for covering showed better storability. The temperature is very important variable in hydrogen peroxide storage. So, when hydrogen peroxide was under $10^{\circ}C$ storability of hydrogen peroxide is much improved.
Yoon, Sung Nyo;Kim, Yun Ki;Jeung, Jeung Hoon;Yoo, Hyun Sang;Min, Kyung Yool;Kim, Min Cheol;Kim, Se Kye;Ryu, Sam Gon
Journal of the Korea Institute of Military Science and Technology
/
v.19
no.5
/
pp.669-674
/
2016
The purpose of this study is to demonstrate the suitability of hydrogen peroxide($H_2O_2$) vapor system for platform interior decontamination. Geobacillus stearothermophilus biological indicator(BI) strips and a field tent were used as a biological simulant and as a simulated platform, respectively. Decontamination was performed based on injection rates and tent sizes with exposure time 60 minutes. We standardized the conditions for the field tent decontamination : 8.0 g/min for $30m^3$($H_2O_2$ vapor concentration of 150~500 ppm, relative humidity of 50 %) and 12.0 g/min for $60m^3$($H_2O_2$ vapor concentration of 250~400 ppm, relative humidity of 55 %). Thus we suggest the system is one of the possible candidates for decontamination of platform interiors.
Kim, Sang Hoon;Jung, Kyoung Hwa;Kim, Se Kye;Chai, Young Gyu;Kim, Yun Ki;Hwang, Hyun Chul;Kim, Min Cheol;Park, Myung Kyu;Ryu, Sam Gon
Journal of the Korea Institute of Military Science and Technology
/
v.16
no.4
/
pp.560-565
/
2013
Biological decontamination means the removal of microorganisms from the inanimate object such as building or equipment. In this study, hydrogen peroxide vapor efficacy test using VHP 1000ED system(Steris LifeSciences) were conducted for G. stearothermophilus spore with agent materials(aluminum, stainless steel, poly-carbonate, viton, silicone, kapton and glass). Total recovered spores exposed to hydrogen peroxide vapor(1.0 g/min) during 7, 15, 30, 60 min were calculated. As a result, all agent materials were totally decontaminated within 60 min at 1.0 g/min concentration with 35% hydrogen peroxide vapor. Finally, we could confirmed that hydrogen peroxide vapor possess sporicidal capacity of G. stearothermophilus and found the optimum decontamination conditions with VHP1000ED system.
Jo, Jin-Oh;Mok, Young Sun;Kim, Seok Tae;Jeong, Woo Tae;Kang, Duk-Won;Rhee, Byong-Ho;Kim, Jin Kil
Applied Chemistry for Engineering
/
v.17
no.5
/
pp.552-556
/
2006
An advanced oxidation process catalyzed by iron ions in the presence of hydrogen peroxide, the so-called Fenton's reaction, has been applied to the treatment of steam generator chemical cleaning waste containing highly concentrated iron(III)- ethyl-enediaminetetraaceticacid (Fe(III)-EDTA) of 70000 mg/L. The experiments for the degradation of Fe(III)-EDTA were carried out not only with a simulated waste, but also with the real one. The effect of pH and the amount of hydrogen peroxide added to the waste on the degradation was examined, and the results were discussed in several aspects. The optimal pH to maximize the degradation efficiency was dependent on the amount of hydrogen peroxide added to the waste. i.e., when the amount of hydrogen peroxide was different, maximum degradation efficiency was obtained at different pH's. The optimal amount of hydrogen peroxide relative to that of Fe(III)-EDTA was found to be 24.7 mol ($H_{2}O_{2}$)/mol (Fe(III)-EDTA) at pH around 9.
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.3
no.1
/
pp.99-99
/
1993
혈액 및 생체시료 중 필수원소 혹은 독극성 원소의 극미량상분 정밀측정과 동위원소비율측정에 널리 사용되는 유도결합플라즈마 질량분석기(ICP-MS)의 기본원리를 소개하고 ICP-SM를 이용한 혈액중 낮은 ppb수준의 Cd, Hg 그리고 Pb의 정밀분석법을 소개한다. 혈액은 많은 양의 유기물을 포함하고 있으므로 digestion bomb에 질산과 과산화수소를 넣어 microwave oven에서 고온고압 상태로 분해시켜 많은 용액을 얻어 이 용액을 플라즈마에 주입시켜 분석한다. 그리고 수온은 tin(II) chloride 용액을 환원제로하여 생성시킨 수은원소증기를 membrane liquid-gas separator를 이용하여 뽑아내어 플라즈마에 주입시켜 낮은 ppt 수준의 검출한계를 얻는다. 또한 높은 정밀도와 정확도와 극미량 원소 측정에 사용되는 동위원소 회석법율 소개하고 실제 혈액분석에의 응용방법을 제시한다.
Proceedings of the Korean Institute of Information and Commucation Sciences Conference
/
2012.10a
/
pp.304-306
/
2012
In this Paper, we develop control system for disinfection of welfare Equipment. In this paper, the developed system including disinfection control circuit using Hydrogen peroxide steam, chamber control circuit for disinfection using low vacuum and washing system control circuit using micro bubble.
Kim, Yun Ki;Kim, Min Cheol;Yoon, Sung Nyo;Hwang, Hyun Chul;Ryu, Sam Gon
Journal of Environmental Health Sciences
/
v.39
no.3
/
pp.279-288
/
2013
Objectives: Effectiveness and conditions of vapor-phase hydrogen peroxide (VPHP) system on decontamination of Geobacillus stearothermophilus(GS) spores, Escherichia coli (E.coli) and Enterobacteria phage felix01 (felix01) were determined. Methods: The VPHP system was designed to vaporize 35% (w/w) solution of hydrogen peroxide, continuously to inject and withdraw VPHP. The system and VHP 1000ED (Steris) were operated such that dehumidification and conditioning were initiated without samples in the chamber. Then the samples were loaded into and removed. Coupons (glass, anodizing, silicon, viton) with GS spores ($1{\times}10^6$ colony forming unit/mL [CFU/mL]), E.coli ($1{\times}10^7$ CFU/mL) and felix01 ($1{\times}10^7$ plaque forming unit/mL[PFU/mL]), and Biological Indicator (BI) with GS spores ($1{\times}10^6$ CFU/mL) on stainless steel coupons were used. The tested samples were sonicated and vortexed, and then were plated for enumeration, followed by incubation at $55^{\circ}C$, 24 hr for GS spores, and at $37^{\circ}C$, 24 hr for E.coli and felix01. BI analysis in broth culture was only qualitative. Results: The efficacy of the VPHP system on decontamination was almost equivalent to that of VHP 1000ED. The conditions for complete decontamination with the VPHP system was as follows: concentration; 700~450 ppm, relative humidity; approximately 55%, and temperature; $34{\sim}32^{\circ}C$. When comparing the decontamination efficiency among different kinds of coupons, glass was the most effective, however, all kinds of coupons were decontaminated completely after 60 min exposure in both systems. Conclusion: The VPHP system can be recommended as an alternative system for traditional system using ethylene oxide, formaldehyde or chlorine dioxide.
Journal of the Korea Institute of Information and Communication Engineering
/
v.18
no.9
/
pp.2251-2258
/
2014
In this paper, an integrated control system for removable welfare equipment disinfection is implemented. The integrated control system consisted of a hydrogen peroxide vapor supply control circuit, a sterilization chamber control circuit using low vacuum, and a washing control circuit using microbubble. A Smart-phone based remote control and monitoring system is implemented to monitor the operating status and communication status for the integrated control system. An experiment is set up to evaluate the performance of the integrated control system. The experiment result confirms that signal and operation status can transmit and receive within the control circuit. The integrated control system shows good performance in terms of sensor interface, communication state and control. In future research, the proposed control system should deploy to an actual system for trial test to prove its performance.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.