• Title/Summary/Keyword: 공진형 센서

Search Result 89, Processing Time 0.027 seconds

Development of Adaptive Signal Pattern Recognition Program and Application to Classification of Defects in Weld Zone by AE Method (적응형 신호 형상 인식 프로그램 개발과 AE법에 의한 용접부 결함 분류에 관한 적용 연구)

  • Lee, K.Y.;Lim, J.M.;Kim, J.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.34-45
    • /
    • 1996
  • The signal pattern recognition program which can perform signal acquisition and processing, the extraction and selection of features, the classifier design and the evaluation, is developed and applied to the classification of artificial defects in the weld zone of Austenitic STS304. The neural network classifier is compared with the linear discriminant function classifier and the empirical Bayesian classifier. The signal through a broadband sensor is compared with that through a resonance type sensor. In recognition rate, the neural network classifier is best, and the signal through a broadband sensor is better.

  • PDF

공진반사광 바이오센서를 이용한 심근경색 마커 감지 기술

  • Heo, Cheol;Kim, Bong-Gyu;Kim, Wan-Jung;Hong, Jong-Cheol;A, Chil-Seong;Kim, Sang-Hyeop;Seong, Geon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.127-127
    • /
    • 2014
  • 인체 내 소량의 생체성분(혈액, 소변 등)을 감지하는 바이오센서 기술은 질병 진단뿐만 아니라 예방 및 관리로 의료서비스 확대, 개인 맞춤형 진료 및 의료비 감소 효과를 가져올 수 있는 기술이다. 광바이오센서는 광학적인 측정방법을 이용하여 다양한 생화학물질들의 상호 반응을 검출해 낼 수 있는 바이오센서로 현재 활발하게 연구가 진행되고 있다. 광 바이오센서는 생체성분 내에 존재하는 전하를 가진 많은 이온들 및 Salt 농도 등에 영향을 받지 않기 때문에 나노 와이어를 이용한 FET (field-effect transistor)형 바이오센서에 비해 많은 장점을 가지고 있다. 일반적으로 광 바이오센서는 형광물질, 인광물질, 발색물질, 방사선 물질 등의 발광물질을 인식물질에 표지하여 인식물질과 분석물질과의 반응유무를 표지된 발광물질의 광학 신호를 감지하여 분석물질을 검출해내는 표지식 광 바이오센서 기술이 상용화되고 있다. 그러나 이러한 분석 방법은 민감도는 우수하지만 분석 시간이 매우 느리고, 고가의 분석 장비 및 복잡한 제조 공정 등의 단점들을 가지고 있다. 이러한 단점들을 극복하기 위하여 생화학 반응 유무를 표지물질 없이 광학적 방식으로 직접 측정할 수 있는 비표지식 광 바이오센서 기술이 최근 들어 많이 연구되고 있다. 본 논문에서는 광파장 이하의 주기를 가진 주기적 공진 격자 표면에서 일어나는 바이오 항원-항체 반응에 대한 공진 반사 파장을 측정하여 생체성분 내에 존재하는 바이오 항원을 고감도로 검출할 수 있는 비표지식 공진반사광 바이오센서 기술을 소개하고자 한다. 공진반사광 바이오센서를 이용하여 human serum내에 존재하는 심근경색 마커인 troponin I (cTnI), creatine kinase MB (CK-MB), myoglobin (MYO)을 0.1 ng/mL 이하의 농도까지 고감도로 측정할 수 있었다.

  • PDF

공진형 구조를 이용한 기기

  • 이상훈;이상욱;김용권
    • 전기의세계
    • /
    • v.42 no.10
    • /
    • pp.32-36
    • /
    • 1993
  • 기계적 공진을 이용하여 센서나 액츄에이터등을 만드는 연구가 MEMS분야에서 활발히 진행되어 오고 있고 그 응용범위가 확대되고 있다. 최근의 반도체 가공기술로 인해 구조물을 작고 정밀하게 만들 수 있고, 조립이 필요없어 높은 신뢰도와 공진형 구조를 이용한 기기를 만들 수 있게 되었다. 또 구조물이 작은 관계로 큰 기계적 공진 주파수를 얻을 수 있기 때문에 큰 선택도를 얻을 수 있어 앞으로 이 분야의 응용 가능성의 폭이 넓다고 할 수 있다.

  • PDF

Highly Sensitive Integrated Photonic Temperature Sensor Exploiting a Polymeric Microring Resonator (폴리머 마이크로링 공진기를 이용한 고감도 집적광학형 온도센서)

  • Lee, Hak-Soon;Kim, Gun-Duk;Lee, Sang-Shin
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.3
    • /
    • pp.224-228
    • /
    • 2008
  • A highly sensitive integrated photonic temperature sensor was proposed and developed incorporating a polymeric microring resonator. The change in the ambient temperature was estimated by observing the shift in the resonant wavelength of the resonator induced via the thermooptic effect. For the purpose of enhancing its sensitivity, the sensor was built by implementing a polymeric resonator exhibiting a high thermooptic coefficient on a silicon substrate with a small coefficient of thermal expansion. For the range of from $20^{\circ}C$ to $30^{\circ}C$ near the room temperature, the fabricated sensor yielded a sensitivity of as high as 165 ${\pm}/^{\circ}C$ and a resolution of better than $0.1^{\circ}C$. And its performance was found to be hardly affected by the variation in the refractive index of the target analyte, which was applied to the surface of the sensor. It is hence expected that the sensor could be integrated with other refractormetric optical sensors, thereby compensating for the fatal error caused by the change in the ambient temperature.

Resonance Fiber Bragg Grating Sensor system based on Fourier Domain Mode-locking Laser (분광 영역 모드록킹 레이저를 이용한 공진형 광섬유 격자 센서)

  • Choi, Byeong Kwon;Jeon, Min Yong
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.211-216
    • /
    • 2012
  • We report a resonance fiber Bragg sensor interrogation based on a Fourier domain mode-locking (FDML) laser. The FDML laser is constructed based on a conventional ring laser cavity configuration with fiber Fabry-Perot tunable filter (FFP-TF). There are two sensor parts which are composed with two FBGs inside the laser cavity. Each sensor part provides a separate laser cavity for the FDML laser. The resonance frequencies of the laser cavities are 46.687 kHz and 44.340 kHz, respectively. We applied a static and a dynamic strain on the FBG sensor system. The slope coefficients of the measured relative wavelength shift and relative time interval from the static strain are found to be $0.61pm/{\mu}{\epsilon}$ and $0.8ns/{\mu}{\epsilon}$, respectively.

Fabrication and Characteristics Comparison of Piezoresistive Four Beam Silicon Accelerometer Based on Beam Location (빔 위치변화에 따른 4빔 압저항형 실리콘 가속도 센서의 제조 및 특성비교)

  • Shin, Hyun-Ok;Son, Seung-Hyun;Choi, Sie-Young
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.7
    • /
    • pp.26-33
    • /
    • 1999
  • In order to examine the effect of beam location n the performance of bridge type piozoresistive silicon accelerometer, three sensors having different location of beams were simulated by FEN(finite element method) and fabricated by RIE(reactive ion etching) and KOH etching method using SDB(silicon direct bonding) wafer, Results of the FEM simulation present that the 1st resonace frequency and Z axis sensitivity of each sensor are identical but the 2nd, and the 3rd resonace frequency and X, Y axis sensitivity are different. Even though the 1st resonance frequency and Z axis sensitivity measured from fabricated sensors do not perfectly coincide with each other, all 3 type sensors present 180 ~ 220N/G of Z sensitivity at 5 V supply voltage and 1.3 ~ 1.7kHz of the 1st resonance frequency and about 2% of lateral sensitivity.

  • PDF

Design of Microstrip Defected Ground Structure-based Sensor with Enhanced-Sensitivity for Permittivity Measurement (유전율 측정을 위한 고감도 마이크로스트립 결함 접지 구조 기반 센서 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.1
    • /
    • pp.69-76
    • /
    • 2019
  • In this paper, a design method for an enhanced-sensitivity microwave sensor based on microstrip defected ground structure was studied for the permittivity measurement of planar dielectric substrates. The proposed sensor was designed by modifying the ridge structure of an H-shaped aperture into the shape of a capacitor symbol. The sensitivity of the proposed sensor was compared with that of a conventional sensor based on a double-ring complementary split ring resonator(DR-CSRR). Two sensors were designed and fabricated on a 0.76-mm-thick RF-35 substrate so that the transmission coefficient would resonate at 1.5 GHz in the absence of the substrate under test. Five types of taconic substrates with a relative permittivity ranging from 2.17 to 10.2 were selected asthe substrate under test. Experiment results show that the sensitivity of the proposed sensor, which is measured by the shift in the resonant frequency of the transmission coefficient, is 1.31 to 1.62 times higher than that of the conventional DR-CSRR-based sensor.

Low vacuum characteristics of the capacitance diaphragm gauges and the resonance silicon gauges (용량형 격막식 게이지와 공진형 실리콘 게이지의 저진공 특성)

  • ;;;I. Arakawa
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.3
    • /
    • pp.151-156
    • /
    • 2003
  • Two capacitance diaphragm gauges(CDG) and two resonance silicon gauges(RSG) were calibrated using an ultrasonic interferometer as a national low vacuum standard in KRISS. The CDG has superior pressure resolution and is rugged as well as resistant to over-pressure because of all-metal inner components. Meanwhile, the RSG is a new type of MEMS sensor that has excellent calibration stability and is resistant to mechanical shocks. The calibration uncertainties were analyzed according to the ISO procedures. Results showed that the maximum difference of the expanded uncertainties was $9\times10^{-3}$Pa at the generated pressure of 100 Pa for the two different types. It is remarkable that the RSG can be used as a transfer standard at low vacuum since their accuracies were found to be within 0.5 %.

Electromechanical Modeling and Experimental Verification of Differential Vibrating Accelerometer (차분 진동형 가속도계 전기적 모델링 및 실험적 검증)

  • Lee, Jung-Shin;Rhim, Jae-Wook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.517-525
    • /
    • 2011
  • Differential Vibrating Accelerometer(DVA) is a small and accurate resonant device to sense the change in natural frequency in presence of acceleration input. Both mathematical modeling for the electromechanical dynamics and experimental investigation on the structural characteristics are necessary for effective designs of precision controller and high Q-factor structure. In this paper, electromechanical modeling of the resonator of DVA, electrode module, and pre-amplifier is presented. The presented method is experimentally verified by measuring the resonance frequency, effective mass, effective stiffness and Q-factor. The direct comparison of the calculated displacement and the actual pre-amplifier of DVA also indicates the effectiveness of this study.

Operation Frequency Dependence of Output of Orthogonal Fluxgate Sensor Fabricated with Ferrite Core (페라이트 코어를 이용하여 제작한 직교형 플럭스게이트 센서의 감도에 미치는 구동주파수의 영향)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.6
    • /
    • pp.200-203
    • /
    • 2012
  • In this study, we have investigated that the operation frequency dependences of the output properties of the orthogonal fluxgate sensor which was fabricated with a ferrite core. An orthogonal fluxgate sensor should be operated in as high as possible frequency to enhance its sensitivity in the case of small sized sensor, because sensitivity of the sensor is proportional to cross section area, winding number and operation frequency. In this study, we investigated the correspondence of the frequency dependence of output and the reactance (inductance and capacitance) of pickup coil and cable. Experimental results represented that we could obtain maximum output (= sensitivity) at optimal frequency which is near LC resonance frequency of the pickup coil and cable.