• Title/Summary/Keyword: 공명주파수

Search Result 259, Processing Time 0.02 seconds

High-intensity focused ultrasound beam path visualization using ultrasound imaging (초음파 영상을 이용한 고강도 집중 초음파 빔 시각화)

  • Song, Jae Hee;Chang, Jin Ho;Yoo, Yang Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.1
    • /
    • pp.16-23
    • /
    • 2020
  • In High-Intensity Focused Ultrasound (HIFU) treatment, effective localization of HIFU focus is important for developing a safe treatment plan. While Magnetic Resonance Imaging guided HIFU (MRIgHIFU) can visualize the ultrasound path during the treatment for localizing HIFU focus, it is challenging in ultrasound imaging guided HIFU (USIgHIFU). In the present study, a real-time ultrasound beam visualization technique capable of localizing HIFU focus is presented for USIgHIFU. In the proposed method, a short pulse, with the same center frequency of an imaging ultrasound transducer below the regulated acoustic intensity (i.e., Ispta < 720 mW/㎠), was transmitted through a HIFU transducer whereupon backscattered signals were received by the imaging transducer. To visualize the HIFU beam path, the backscattered signals underwent dynamic receive focusing and subsequent echo processing. From in vitro experiments with bovine serum albumin gel phantoms, the HIFU beam path was clearly depicted with low acoustic intensity (i.e., Ispta of 94.8 mW/㎠) and the HIFU focus was successfully localized before any damages were produced. This result indicates that the proposed ultrasound beam path visualization method can be used for localizing the HIFU focus in real time while minimizing unwanted tissue damage in USIgHIFU treatment.

음향공에 의한 LOX-RP1 고주파 음향-연소안정화에 관한 연구

  • 이길용;윤웅섭;조용호
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.5-5
    • /
    • 2000
  • 액체 추진 로켓 엔진의 고주파 연소 불안정 관련 이론은 대체로 연소기 내부의 음향 공명 모드와 분무 연소 과정의 상호 작용을 구동 메커니즘으로 전제하며 Rayleigh Criterion의 재해석에 기초하여 불안정성 평가를 위한 매개변수를 도입하고 연소 불안정성을 예측한다. 여기에는 음향장 분석 이론, 음향 불안정 이론, 연소응답 및 기화반응 이론 등이 포함된다. 본 연구에서는 LOX/RPl 추진제 조합의 액체 추진 로켓 엔진 연소기를 대상으로 다차원 순수 음향장 해석과 연소-음향장 분석을 통해 대상 엔진의 고주파 연소 불안정 특성을 예측하였다. 수동 제어 기기인 음향공 설치에 따른 연소기의 음향장 및 연소-음향장의 특성 변화를 고찰하고 위 결과를 종합하여 음향공의 연소 불안정 억제 성능 및 대상 엔진의 연소 불안정성을 평가하였다. 연소기 형상 및 음향공 설치에 따른 다차원 순수 음향장 해석은 상용코드인 ANSYS를 사용하여 수행하였다. 내부 유체는 압축성, 비점성 유체로 유체의 평균 유동은 무시하며 위치에 관계없이 균일한 물성치를 부여하였다. 정상상태 연소과정을 가정하고 평형 화학을 이용한 분석 결과로부터 연소 기체의 관련 물성치를 결정하였다. 연소기 길이 방향, 반경 방향, 원주 방향 격자점들의 음향 특성을 주파수 영역에 대해 해석하고 3차원 음향 모드 형상을 토대로 음향장을 분석하였다. 연소-음향장 해석은 음향 불안정 이론 중 n- $\tau$ 2 매개변수 기법을 사용하였다. 연료 액적의 분무 연소 과정을 1차원적으로 가정하고 정상상태의 평형 화학 계산 결과를 이용하여 엔진의 연소면을 1차원적으로 설정하였다. 상류 연소응답과 중립 안정 곡선을 토대로 대상 엔진의 연소 불안정 특성을 분석하였다.구 분석 결과 기술적 문제점으로는 배기 가스온도가 낮은데 따른 출구 부분의 Bearing, Sealing이 문제가 될 수 있다고 판단되며 배기 가스 자체에 대기 공기중에 함유되어 있던 습기가 얼어붙는(Icing화) 문제가 발생하기 때문에 배기가스의 Icing을 방지하기 위하여 압축기 끝단에서 공기를 추출하여 배기부분에 송출할 필요성이 있는 것으로 판단되었다. 출구가스의 기체 유동속도가 매우 빠르므로 (100-l10m.sec) 이를 완화하기 위한 디퓨저의 설계가 요구된다고 판단된다. 또 연소기 후방에 물을 주입하는 경우 열교환기 및 기타 부분품에 발생할 수 있는 부식 및 열교환 효율 저하도 간과할 수 없는 문제로 파악되었다. 이러한 기술적 문제가 적절히 해결되는 경우 비활성 가스 제너레이터는 민수용으로는 대형 빌딩, 산림, 유조선 등의 화재에 매우 적절히 사용되어 질 수 있을 뿐 아니라 군사적으로도 군사작전 중 및 공군 기지의 화재 그리고 지하벙커에 설치되어 있는 고급 첨단 군사 장비 등의 화재 뿐 아니라 대간첩작전 등에 효과적으로 활용될 수 있을 것으로 판단된다.가 작으며, 본 연소관에 충전된 RDX/AP계 추진제의 경우 추진제의 습기투과에 의한 추진제 물성 변화는 미미한 것으로 나타났다.의 향상으로, 음성개선에 효과적이라고 사료되었으며, 이 방법이 편측 성대마비 환자의 효과적인 음성개선의 치료방법의 하나로 응용될 수 있으리라 생각된다..7%), 혈액투석, 식도부분절제술 및 위루술·위회장문합술을 시행한 경우가 각 1례(2.9%)씩이었다. 13) 심각한 합병증은 9례(26.5%)에서 보였는데 그중 식도협착증이 6례(17.6%), 급성신부전증 1례(2.9%), 종격동기흉과 폐염이 병발한 경우와 폐염이 각 1례(2.9%)였다. 14)

  • PDF

A Comparison of the Implant Stability Among the Bone Density Groups: Prospective Study (골밀도와 임플란트 안정성 변화에 대한 전향적 연구)

  • Ko, Sok-Min;Park, Seong-Jae;Lee, In-Kyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.11-21
    • /
    • 2013
  • The purpose of this study was to get a proper time when implant was loaded and superstructure was fabricated by tracing a change of the implant stability in bone type for 1 year. We carried out RFA(resonance frequency analysis) of 67 implants in 36 patients at the time of surgery, 2, 6, 10, 14weeks, and 1year postoperatively for each implant, and analyzed data for different bone density. The ISQ value at the time of 10 & 14weeks postoperatively were significant(P<0.01) in subjective grouping, while that were not significant in objective grouping(P>0.05). The change pattern of ISQ value could be expressed $y=y_0+a{\times}\{1-\exp(-b{\times}x)\}$ for 1 year in this study, ISQ value at surgery might be used to estimate the time of superstructure fabrication consequentially.

A Study on Dynamic Pile-Soil-Structure Interactions (말뚝-지반-구조물의 동섬 상호작용 연구)

  • Lee, In-Mo;Lee, Gwan-Ho;Kim, Yong-Jin
    • Geotechnical Engineering
    • /
    • v.7 no.1
    • /
    • pp.41-52
    • /
    • 1991
  • A study of the effects of dynamic pile-soil-structure interactions on the response of super- structures, supported by group piles, are presented in this paper. The dynamic impedance functions of single pile generated by soil-pile interactions are obtained and compared among others using the methods proposed by Novak, Gazetas, and Kuhlemeyer, and using the equivalent cantilever method. Group pile effects are also considered by the following approaches : neglecting interaction effects : group efficiency ratio concept : static interaction approach . and dynamic interaction approach. The responses of a nuclear containment structure are obtained by using the elastic half-space analysis, based on the impedance functions mentioned above. Main conclusions drawn from this study are as follows : 1. The numerical results of the impedance functions calculated by each method were quite different : the Novak's was the smallest, and the Kuhlemeyer's the highest. Considering group effects, similar values in each approach were obtained for the stiffness : the difference was very big for the damping. 2. The top displacement of the structure was reduced by 20% or more by pile installations. However, the base shear force, the base moment, and the resonance frequency were increased by more than two times due to stiffening effect of the ground by pile installations. 3. Whether frequency dependant impedence functions or frequency independant functions were used, the responses of the structure were not so much affected by the choice of the impedance functions. 4. The reduction effect of the top displacement increased with the increase of the maximum ground acceleration.

  • PDF

MR Study of Wate Exchange and Cell Membrane Permeability in Rat Liver Cells Using a Tissue-Specific MR Contrast Agent (조직 특성 MR 조영제를 이용한 쥐의 간세포막의 물분자 교환 및 투과율의 MR 측정기법)

  • Yongmin Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.73-82
    • /
    • 1998
  • Purpose : A precise NMR technique for measuring the rate of water exchange and cell membrane permeability across the hepatocyte membrane using liver-specific MR contrast agent is described. Materials and Methods : The rat hepatocytes isolated by perfusion of the livers were used for the NMR measurements. All experiments were performed on an IBM field cycling relaxometer operating from 0.02MHz to 60 MHz proton Larmor frequency. spin-echo pulse sequence was empolyed to measure spin-lattice relaxation time, T1. The continuous distribution analysis of water proton T1 data from rat hepatocytes containing low concentrations of the liver specific contrast agent, Gd-EOB-DTPA, modeled by a general two compartment exchange model. Results : The mean residence time of water molecule inside the hepatocyte was approximately 250 msec. The lower limit for the permeability of the hepatocyte membrane was $(1.3{\pm}0.1){\;}{\times}{\;}10^{-3}cm/sec$. The CONTIN analysis, which seeks the natural distribution of relaxation times, reveals direct evidence of the effect of diffusive exchange. the diffusive water exchange is not small in the intracellular space in the case of hepatocytes. Conclusions : Gd-EOB-DTPA, when combined with continuous distribution analysis, provides a robust method to study water exchange and membrane permeability in hepatocytes. Water exchange in hepatocyte is much slower thatn that in red blood cells. Therefore, tissue-specific contrast agent may be used as a functional agent to give physiological information such as cell membrane permeability.

  • PDF

A 3 year prospective study of survival rate of narrow diameter implants (좁은 직경 임플란트 3년간의 생존율에 관한 후향적 연구)

  • Lee, Sung-Jo;Jung, Sae-Young;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.32-38
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of narrow diameter implant less than 3.6 mm by initial stability and radiographic measurements. Materials and Methods: In total, 24 patients who received 38 narrow diameter implants (${\leq}3.6mm$ in diameter, ${\geq}7mm$ in length) were enrolled in this retrospective study. The cumulative survival rate was calculated and various factors were investigated according to the implant platform diameter, body diameter, length, position, concomitant use of guided bone regeneration in implant placement and final prosthesis type. Initial stability was investigated with implant stability quotient (ISQ) value. The mesial and distal marginal bone level (MBL) change was calculated with radiography. Results: The overall survival rate was 92.11%. Mean ISQ value and MBL change of survival implants was 66.26 and $0.14{\pm}0.31mm$, respectively. None of the implants with platform diameters larger than the body diameter failed. Conclusion: In conclusion, the findings of present study suggest that narrow diameter implant could be predictable treatment in narrow alveolar ridge.

Effects of Magnetic Resonance Imaging on the Human Body : Analysis of differences according to Dental Implant Material (자기공명영상이 인체에 미치는 영향 : 치아임플란트 재료에 따른 차이 분석)

  • Choe, Dea-yeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.481-489
    • /
    • 2018
  • In MRI examination, when irradiating the human body with RF Pulse to acquire images, the portion of the irradiated RF Pulse energy is absorded into the human body, and this will affect the temperature of the human body. If a metal is inserted into the human body even if the same RF Pulse energy is applied, the SAR value increases and the body temperature changes due to the increase in the electromagnetic wave conductivity of the metal. So we measure and compared with the change in the SAR and temperature in the implant material of the dental implant in Brain MRI examinations. Experiments were performed on a human head model using a 64MHz and 128 MHz RF Pulse frequency generated by a 3.0 Tesla MRI apparatus. And then changed material of dental implants to Titanium and $Al_2O_3$. Using the XFDTD program, the changes in SAR and body temperature around the head were examined. When with Titanium the SAR value and temperature of Brain increased, but with $Al_2O_3$ showed lower SAR and temperature as compared with Titanium. The dental implants were low in SAR and temperature of the head in $Al_2O_3$, which are electrical insulators with low electrical conductivity, compared to Titanium, which is an electrical conductor. It is necessary to study the biologic effect of patient with brain MRI when titanium dental implant material is inserted in the future. Because the maximum value of SAR is much higher than the limit when dental implant material is Titanium. In addition, it is necessary to use an implant of $Al_2O_3$ material to reduce the SAR value and temperature of the Brain in Brain MRI examination.

The influence of implant diameter, length and design changes on implant stability quotient (ISQ) value in artificial bone (임플란트의 직경, 길이 및 디자인변화가 임플란트 안정성지수(ISQ)에 미치는 영향)

  • Lee, Jeong-Yol;Lee, Won-Chang;Kim, Min-Soo;Kim, Jong-Eun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.292-298
    • /
    • 2012
  • Purpose: The purpose of this study is to ascertain the stability of the implant by comparing the effects of the change of implant diameter, length and design on implant stability quotient. Materials and methods: To remove the variable due to the difference of bone quality, the uniform density (0.48 g/$cm^3$) Polyuretane foam blocks (Sawbones$^{(R)}$, Pacific Research Laboratories Inc, Vashon, Washington) were used. Implants (Implantium$^{(R)}$, Dentium, Seoul, Korea) were placed with varying diameters (${\phi}3.8$, ${\phi}4.3$ and ${\phi}4.8$) and length (8 mm, 10 mm and 12 mm), to assess the effect on implant stability index (ISQ). Also the influence of the design of the submerged and the non-submerged (SimplelineII$^{(R)}$, Dentium, Seoul, Korea) on ISQ was evaluated. To exclude the influence of insertion torque, a total of 60 implants (n = 10) were placed with same torque to 35 N. Using Osstell$^{TM}$ mentor (Integration Diagnostic AB, Sweden) ISQ values were recorded after measuring the resonant frequency, one-way ANOVA and Tukey HSD test results were analyzed. (${\alpha}$=0.05). Results: 1. The change of the diameter of the implant did not affect the ISQ (P>.05), but the increase of implant length increased the ISQ(P<.001). 2. The change in implant design were correlated with the ISQ, and the ISQ of submerged design was significantly higher than that of the non-submerged design(P<.05). Conclusion: In order to increase implant stability, the longer implant is better to be selected, and on the same length of implant, submerged design is thought to be able to get a higher ISQ than the non-submerged.

The Photovoltaic Effect of Iodine-Doped Metal Free Phthalocyanine/ZnO System (Ⅰ) (요오드가 도핑된 무금속 프탈로시아닌/산화아연계의 광기전력 효과(Ⅰ))

  • Heur, Soun-Ok;Kim, Young-Soon;Park, Yoon-Chang
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.3
    • /
    • pp.163-175
    • /
    • 1995
  • Metal free phthalocyanine($H_2Pc$) partially doped with iodine, $H_2Pc(I)x$, has been made to improve photosensitizing efficiency of ZnO/$H_2Pc$. The content of iodine dopant level(x) for $H_2Pc(I)x$ upon $H_2Pc$ polymorphs was characterized as ${\chi}-H_2Pc(I)_{0.92}$ and ${\beta}-H_2Pc(I)_{0.96}$ by elemental analysis. Characterization of iodine-oxidized $H_2Pc$ were investigated by TGA (thermogravimetric analysis), UV-Vis, FT-IR, Raman and ESR (electron spin resonance) spectrum, and the adsorption properties of $H_2Pc(I)x$ on ZnO were characterized by means of Raman and ESR studies. TGA for $H_2Pc(I)x$ showed a complete loss of iodine at approximately 265$^{\circ}C$ and the Raman spectrum of $H_2Pc(I)x$ and ZnO/$H_2Pc(I)x$ at 514.5 nm showed characteristic $I_3^-$ patterns in the frequency region 90∼550 $cm^{-1}$. ZnO/$H_2Pc(I)x$ exhibited a very intense and narrow ESR signal at $g=2.0025{\pm}0.0005$ compared to $H_2Pc$/ZnO. Iodine doped ZnO/$H_2Pc(I)x$ showed a better photosensitivity compared to iodine undoped ZnO/$H_2Pc$. That is, the surface photovoltage of ${\chi}-H_2Pc(I)_{0.92}$/ZnO was approximately 31 times greater than that of ZnO/${\chi}-H_2Pc$ and ZnO/${\beta}-H_2Pc(I)_{0.96}$ was 5 times more efficient than ZnO/${\beta}-H_2Pc$ at 670 nm. And the dependence of photosensitizing effect upon $H_2Pc$ polymorphs was exhibited that the surface photovoltage of ZnO/${\chi}-H_2Pc(I)_{0.92}$ was approximately 5 times greater than ZnO/${\beta}-H_2Pc(I)_{0.96}$ at 670 nm. Therefore Iodine doping of H_2Pc$ resulted in increase in photoconductivity of $H_2Pc$ and photovoltaic effect of ZnO/$H_2Pc$ in the visible region.

  • PDF