• Title/Summary/Keyword: 공기 분포

Search Result 813, Processing Time 0.029 seconds

Visualization of Water Distribution in Cathode Side of a Direct Methanol Fuel Cell Using Neutron Radiography (중성자 라디오그래피 방법을 이용한 직접 메탄올 연료전지 공기극의 내부 물 분포 가시화)

  • Je, Jun-Ho;Doh, Sung-Woo;Kim, Tae-Joo;Kim, Jong-Rok;Xie, Xiaofeng;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.10
    • /
    • pp.965-970
    • /
    • 2012
  • In this study, the water distribution in the cathode side of a direct methanol fuel cell (DMFC) is visualized using a neutron imaging technique at the Neutron Radiography Facility (NRF), KAERI. It is difficult to quantify the water content in the cathode side because of $CO_2$ gas. A compared open circuit voltage (OCV) image, relative $CO_2$, and water distribution can be visualized by the neutron imaging technique. This means that the neutron imaging technique is useful for the optimization of the flow field design and the establishment of water management, and, in turn, for the improvement of the cell performance.

Characteristics of Surface Backscattering Signal in the Coastal Bay (내만에서의 해수면 후방산란신호 특성)

  • 최지웅;나정열;조운현
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.46-53
    • /
    • 2000
  • In coastal bay waters, bubbles are generated by relatively heavy ship-traffic, breaking waves due to man-made structures and biological activities. Therefore, the bubble-generating mechanism as well as the bubble density distribution in the bay are quite different from the open ocean where breaking waves are major contributor for bubble density distribution. High frequency surface-backscattered signals were obtained in the coastal bay waters and they were analyzed to compare with those from the open waters in terms of the sea-surface backscattering strength at various grazing angles, the reverberation characteristics in the sub-surface layer and spectral spreading of the scattered signals. The results show that, the surface scattered signals have an irregular distribution of amplitude in time and the width of the spectral spreading is wider than that of the open sea with rough surface. Furthermore, the amplitude distribution of the reverberation signals is not following the Rayleigh distribution, that is eon to be a typical pattern for the open ocean. The results of our analysis imply that the bubble size and the bubble density in the bay are quite different from those observed in the open waters.

  • PDF

Microbial Distribution as an Environmental Factor for the Conservation of Cultural Properties in the War Memorial in Korea (전쟁기념관내 문화재 보존을 위한 환경요인으로서의 미생물의 분포)

  • Choi, Yoon Jeong;Lim, Sun Ki;Min, Kyung Hee
    • Journal of Conservation Science
    • /
    • v.7 no.1
    • /
    • pp.31-41
    • /
    • 1998
  • Two isolation methods using the open plate and air sampler were applied to examine microbial distribution as an environmental factor for conservation of cultural properties in the War Memorial in Korea. The numbers of fungi were the abundant in the air of entrance and inside of the exhibition room where visitors were crowded, compared with inside of repository rooms. Fungal and bacterial distributions in the exhibition room during exhibition period were higher than during nonexhibition period, These results are due to the inflow of air current carrying microoganisms to the exibition rooms from outside with visitors. Fungi isolated from the War Memorial were identified as 19 species and one thermophilic fungus, Neurospora crassa. The majority of the isolated fungi are seemed to cause damage to cellulose materials in the Memorial.

  • PDF

Numerical Study of the Characteristics of Internal Flow Including an Air Core in a Cylindrical Tank (공기기둥이 형성된 원통 용기의 내부유동 특성에 관한 수치해석 연구)

  • Park, Il-Seouk;Son, Jong-Hyeon;Sohn, Chang-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • An air core is generated during draining through an axisymmetrically placed circular orifice after rotating a cylindrical tank filled with a liquid. If an air core is generated, the draining flow rate decreases and the draining time increases. In this study, the process of the formation of the air core and internal flow characteristics in a cylindrical tank are studied by numerical methods. Several methods are used in the analysis, and the results are compared with experimental results to obtain the appropriate scheme. Axial, radial, and swirl velocity profiles on a variety of heights are shown graphically, and the internal flow structure is analyzed from the velocity profiles, the vector plot, and the stream function distribution.

Stability Analysis of Concrete Plugs Installed in Pilot Tunnels for the Storage of Compressed Air (압축공기 저장용 파일롯 터널에 설치된 콘크리트 플러그의 안정성 해석)

  • Lee, Youn-Kyou;Song, Won-Kyoung;Park, Chul-Whan;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.20 no.6
    • /
    • pp.446-454
    • /
    • 2010
  • CAES-G/T (Compressed Air Energy Storage - Gas Turbine) power generation is a likely option for the buffer facility stabilizing the fluctuation of the renewable powers, such as wind and solar powers. Considering the geological conditions, the underground CAES facility is most probable if the CAES-G/T generation is planed in Korea. In this kind of facility, a concrete plug is installed to seal the compressed air in the container, so that the selection of the shape and dimension of concrete plug could be a critical design factor. The stability evaluation of two types of plug was carried out by investigating the distribution of the factor of safety in the plugs and the distribution of contact pressure over the contact surface. The analysis result shows that the taper-shaped plug is more structurally stable than the wedge-shaped plug for the given geological condition. Possible separation of the rock-concrete interface around the spring line of the wedge-shaped plug is anticipated, which means the possible leakage of compressed air through the side wall and also means the poor mobilization of frictional resistance on that area.

Mixed Convection in an Asymmetrically Heated Vertical Parallel-Plate of Finite Length Duct Flow (비대칭적으로 가열된 유한 수직덕트내 유동의 혼합대류에 관한 연구)

  • ;B.F. Armaly
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1774-1780
    • /
    • 1991
  • 본 연구에서는 유한 길이를 갖는 수직 덕트내 공기 유동의 속도 분포를 LDV를 사용하여 측정하며 유동 특성에 미치는 가열정도, 덕트간격 및 입구소도등의 영향을 보고하고자 한다. 또한 속도분포, 온도분포 및 열전달에 미치는 부력의 영향을 수치 적으로 예측하여 그 타당성을 검증하고자 한다.

CD-ROM드라이브의 내부 소음원 탐지를 위한 전달특성 연구

  • 이동욱;차성운
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.99-99
    • /
    • 2004
  • CD-ROM에서 생성되는 소음은 구조소음과 공력소음의 분포비율을 생각해 볼 때 하드디스크 등의 경우와는 다소 다른 특성이 있는데, 구조적으로 차폐나 디스크의 크기 및 회전속도 등의 차이로 인해 공력소음의 비중이 매우 커진 점을 들 수 있다. 공기역학적으로 생성되는 소음은 구조소음의 경우와는 다르게 에너지 분포가 주기성을 찾아보기 어려우며 널은 주파수 대역에 고루 분포하는 특징이 있다.(중략)

  • PDF

A Study on the Uniform Mixing of Ammonia-Air with the Change of Ammonia Supply Device Shape in a De-NOx System (탈질설비에서 암모니아 혼합기의 형상에 따른 암모니아-공기 균일 혼합에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.20-26
    • /
    • 2019
  • Selective catalytic reduction(SCR) method is widely used among various methods for reducing nitrogen oxides in combustion devices of coal power plant. In the present study, the computational fluid dynamic analysis was accomplished to derive the optimal shape of ammonia-dilution air mixing device in a ammonia injection grid. The distribution characteristics of flow and $NH_3$ concentration had been elucidated for the reference shape of ammonia mixing device(Case 1). In the mixing device of Case 1, it could be seen that $NH_3$ distribution was shifted to the wall opposite to the inlet of the ammonia injection pipe. For the improvement of $NH_3$ distribution, the case(Case 2) with closing one upper injection hole and 4 side injection holes, the case(Case 3) with installing horizontal plate at the upper of ammonia injection pipe, the case(Case 4) with installing horizontal plate and horizontal arc plate at he upper of ammonia injection pipe were investigated by analyzing flow and $NH_3$ concentration distributions. From the present study, it was found that the % RMS of $NH_3$ for Case 4 was 4.92%, which was the smallest value among four cases, and the range of $R_{NH3}$ also has the optimally uniform distribution, -10.82~8.34%.

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

Characteristics of Indoor PM2.5 and the effect of air purifier and ventilation system on Indoor PM2.5 in the Knowledge Industrial Center office during the atmospheric PM2.5 warning (초미세먼지 주의보 시 지식산업센터 사무실의 실내 초미세먼지 농도 특성과 공기청정기와 환기장치의 영향)

  • Ji, Jun-Ho;Joo, Sang-Woo
    • Particle and aerosol research
    • /
    • v.16 no.3
    • /
    • pp.65-72
    • /
    • 2020
  • In this study, the indoor fine dust concentration in an office of the Korea Knowledge Industry Center was measured for about 80 hours when the concentration of atmospheric PM2.5 was very high. The effect of the operation of the air cleaner and the forced ventilation system on the indoor PM2.5 was investigated, and the particle size distribution of the indoor and outdoor particles was analyzed. When forced ventilator and air purifiers were partially used, the indoor PM2.5 concentrations were maintained between 27.7 ㎍/㎥ and 32.9 ㎍/㎥ when the atmospheric PM2.5 was 127.7 ㎍/㎥ to 141.6 ㎍/㎥ during working hours. It is more effective to operate the air purifier without operating the forced ventilation system when the concentration of the PM2.5 is high since the PM2.5 penetrating the installed filter is continuously introduced indoor from the outside.